Preview only show first 10 pages with watermark. For full document please download

Vid-03p-manual

   EMBED


Share

Transcript

UTP (unshielded twisted pair) Passive Video Transceiver Installation Instructions General This manual is a guide to the installation and operation of the VID-03P model VIDIPAC UTP. Please read the entire manual before installing. Brief description VID-03P model is a single channel passive transceiver with screw-less Terminal block and built-in transient protection. VID-03P Passive Balun allows a single CCTV video signal to be transmitted via cost-effective Unshielded Twisted Pair (UTP) cable. Used in pair, the UTP CCTV passive balun can connect the CCTV security and surveillance equipments using standard structured cabling techniques for neater and more streamlined cabling instead of costly and bulky coaxial cable. VID-03P is small in size and can be fixed with outer housing of a camera. It also works in conjunction with other VIDIPAC passive transceivers and passive hubs. Features of VID-03P • PAL, NTSC, SECOM video compatible • Passive device, no power required • Transmission range: Colour signal up to 225m* working with passive transceivers • Screw-less Terminal block reduces wiring time • High crosstalk and noise immunity • Compact size and BNC-male with 13cm coaxial cable pigtail • One year warranty Technical specifications Model Vidipac VID-03P Bandwidth Video Cable Type Environmental DC-6MHz Insertion Loss 0.5dB CMMR Typical 60dB UTP Cable 75ohm Coaxial Cable 100ohm Coaxial Connector BNC-male with174mm overall coax pigtail UTP Connection Quick-Connect terminal block Specification* UTP 24AWG minimum, Cat-3 upwards, 225m* maximum PAL & 300m maximum NTSC for CAT-5 Resistance 100ohm±20% DC Loop Resistance 18ohm/100m Differential Capacitance 62pf/m Temperature Operating: -20° to 75° C Humidity 0~95% Anti-transient Ability 6000V 1.2μS×50μS Weight 25g Dimensions - overall of balun of balun Dimensions - overall Overall length Overall length Mechanical Drawing Mechanical Drawing 61.8mm (L) × 20mm (W) × 17.8mm (H) Length 61.8mm !Width 20mm ! Height 17.8mm 215mm approximately 215mm approximate Installation Caution • Unshielded Twisted Pair (UTP) wires must be used. Note: Shielded twisted pair wires cause impedance mismatch • Make sure there are no untwisted wires as it may result in distorted image and interference. • Each video signal must use the same twisted pair. • Make sure there are no extra branch (or star connection) of twisted pair as it results in ghost image. Always connect the transceivers with point-to-point Unshielded Twisted Pair wires. • Coaxial cable length between the video equipment and the passive UTP transceiver balun must not exceed 1.8m. Transceiver installation • Connect the VID-03P passive transceivers as close as possible through the coaxial cable to the video equipments (Camera, monitors, VCRs, DVRs, etc.) • VID-03P passive transceivers have ‘+’ and ‘-’ terminals. • Use a pair of Unshielded Twisted Pair (UTP) wires to connect the transceivers Connection Diagram • Make sure the ‘+’ of one transceiver is connected to the ‘+’ of another transceiver and vice versa for the ‘-’ terminal. Connection Diagram Transceiver performance table for UTP video within 225m Transceiver Receiver Distance Antiinference Up to 225m YES Power Floating Surge Supply within 225m Protection Transceiver performance table for UTP video VID-02P VID-03P VID-03P VID-Hub-04P Transceiver VID-Hub-08P Receiver Distance NO Antiinterference PowerNO Supply Floating YES Surge Protection NO NO YES VID-Hub-16P VID-03P VID-03P Troubleshooting VID-02P Up to 225m VID-03P Up to 225m VID--Hub• No Signal on the Monitor. Make sure VID-03P Up to 225m YES  Terminal are well04P connected VID-03P  Same pair of UTPVID--Hubwire is used Up to 225m • Twisted image. Make Sure 08P VID--Hub VID-03P  ‘+’ terminal is connected to ‘+’ and vice for ‘-’ Up versa to 225m 16P • The video image is somewhat red and a red bar moves downward. Make sure  BNC connector is well connected  Equipments are well grounded • The video is not stable and has ghost effect. Make sure Troubleshooting  There extra branch connection)Make from the twisted • are NonoSignal on (or thestarMonitor. surepair  A single length UTP wire is used ! Terminal are well connected • Noisy image. Make sure ! Same pair of UTP wire is used  There are no untwisted UTP wires to avoid interference • Attenuated image. Make sure • Twisted image. Make Sure  Coax length is less than 1.8m ! ‘+’ terminal is connected to ‘+’ and vice versa for ‘-’  UTP length is less than 225m • Distorted image. Make sure video is avoid somewhat and a red bar moves downward.  To•useThe UTP wires Cat3image upwards to impedancered mismatch. Make sure ! BNC connector is well connected ! Equipments are well grounded • The video is not stable and has ghost effect. Make sure With sales and support from over 22 Locations