Preview only show first 10 pages with watermark. For full document please download

View Our Nonstop Drip Emitters

   EMBED


Share

Transcript

Product Description NonStop® Bowsmith NonStop Series Emitters incorporate a series of flexible silicone orifices. The silicone is highly resistant to chlorine and most commonly used fertilizers. Each orifice retains its shape and performance for years. Bowsmith’s famed NonStop emitter family, is known worldwide for unmatched performance under the most challenging conditions. The “NonStop” design features the exclusive Continuous Flushing Action, which continually flushes the emitter of slime and small particles while the emitter is in operation. This means fewer clogs and lower maintenance requirements. Drip Emitters Product Description The Bowsmith NonStop emitter design, patented in 1974, is based on a simple unique principle found in no other emitter. This Pressure Cascade Principle permits the emitter to tolerate large amounts of suspended solids in irrigation water, without clogging and without the need for fine-mesh screens. How filter it works 1 Under normal conditions, there is a slight pres- sure differential across each orifice in the silicone diaphragm. How it works path is a series of orifices in the 1 The flow 2 As a particle encounters the orifice, there is asilicone diaphragm. 0 PSI 18 PSI 20 PSI 20 PSI Orifice Open Low pressure across diaphragm (Approximately 2 psi) momentary obstruction, causing the differential pressure across the orifice to increase greatly. This pushes the particle through thepressure expanding operation, the total difference between 2 Ininletnormal orifice. and outlet is divided equally across each of the orifices 18 PSI in the flow path. - For example: 20 psi inlet pressure, and 10 orifices in the flow path, the pressure drop across each orifice is 2 psi. 20 PSI Momentary Blockage High difference pressure (Up to line pressure) 3 The particle is then flushed through the orifice, If an obstruction should occur in any of the orifices, the flow which to its normal size. Normal 3instantly returns that are orifice will be momentarily restricted. As a result, pressure through conditions restored. The particle pressurethe drop across thatorifices orifice will increase, causing the continuesthe through remaining in the orifice enlarge until the obstruction diaphragm andtoout of the NonStop emitter.has passed. Obstruction pushed through Low difference pressure restored NonStop Drip Emitters Nominal Performance Flow, GPH (LPH) For over 40 years, millions of Bowsmith NonStop emitters have demonstrated that the unique NonStop Continuous 4.0 Self-Cleaning Action ( Pressure (15.1) Cascade Principle) really works, even under conditions that would quickly clog ordinary emitters. With only 30-mesh filtration (recommended minimum), Bowsmith NonStop emitters have operated successfully with water containing heavy 3.0concentrations of sand, silt, iron bacteria “slime”, calcium carbonates, even algae and moss. (11.4) 2.0 GPH Models* This means: • Trees & Plants will 2.0be Irrigated (7.6)Loss and Stress • Reduction in Plant 1.0 GPH Models* • Less Maintenance-Lower Labor Costs 1.0 • Lower Capital Investment in Filtration Equipment. (3.8) GPH Models* Bowsmith emitters are available in single and multi outlet models, and with flow rates of 0.6 gph, 1.0 gph, 2.00.6 gph, and 3.0 gph. 0 10 (0.69) 15 (1.03) 20 (1.38) Pressure, PSI (bars) Bowsmith, Inc. DE01-0700 “SL” Series • Manufacturer’s variation, C v : ≤ 0.05 25 30 (1.72) (2.07) *Nominal Flow at 20 PSI Toll-Free USA: P.O. Box 428 • Exeter, CA 93221 USA “ML” Series Notes • 30-mesh filtration and 15 PSI emitter operating pressure are the recommended minimums for a NonStop emitter system. 1-(800) BOWSMITH 1-(800) 269-7648 (559) 592-9485; Fax: (559) 592-2314 www.bowsmith.com “SB” Series P.O. Box 428 • Exeter, CA 93221 USA Toll-Free USA: 1-(800) BOWSMITH 1-(800)-269-7648 P: (559) 592-9485 F: (559) 592-2314 www.bowsmith.com rev.121515 NonStop ® NONSTOP® Drip Emitters Drip Emitters Product Description Bowsmith’s famed NonStop Description emitter family, is known worldwide for unmatched performance Single barb outlet, “SB” challenging Series under the most conditions. 0.250" andThe 0.175" “NonStop” design features the exclusive barbs onContinuous opposite Flushing Action, which continually flushes thebe ends; either can emitter of slime and small particles while the used as inlet. emitter is in operation. This means fewer clogs and lower maintenance requirements. Single outlet, 1/2" “SL200” Series FPT inlet. barbed elbow outlet port. “M200” Series “ML200” Series SB-30 6124 3.0 GPH (11.4 LPH) (Yellow Insert) SL206 SL210 SL220 SL230 6034 6035 6036 6037 0.6 GPH 1.0 GPH 2.0 GPH 3.0 GPH 6 outlets open, 0.250" barb inlet. Includes full set of elbow/outlet caps and line plugs. M206 7063 How it works 6 outlets open, 1/2" FPT inlet. Includes full set of elbow/outlet caps and line plugs. ML206 6 outlets open, 1/2" Series “2000” Flow Distributor FPT inlet. Includes full set of elbow/outlet caps and line plugs. “Gripper” Series Model No. Stock No. Specifications Flow @ 20 PSI Bowsmith NonStop Series Emitters–Nominal incorporate a series of flexible silicone orifices. The silicone is SB-06 6120 to chlorine (Green Insert) 0.6 GPH LPH) highly resistant and( 2.3 most commonly used fertilizers. Each orifice retains its shape andInsert) SB-10 6121 (Blue performance for years.1.0 GPH ( 3.8 LPH) SB-20 6123 2.0 GPH ( 7.6 LPH) (Red Insert) Single outlet, barb inlet, gripper sleeve. Available factory installed on Bowsmith tubing. ( 2.3 LPH) ( 3.8 LPH) ( 7.6 LPH) ( 11.5 LPH) 0.6 GPH ( 2.3 LPH) (Green Port) (Blue Port) (Red Port) (Yellow Port) (Green Cap) 1 Under normal there a slight presM210 7064 conditions, 1.0 GPH ( 3.8isLPH) (Blue Cap) sure differential across each orifice in the silicone diaphragm. M220 7066 2.0 GPH ( 7.6 LPH) (Red Cap) 7068 0.6 GPH ( 2.3 LPH) (Green Cap) ML210 7069 encounters 1.0 GPH 3.8 LPH) 2 As a particle the (orifice, there(Blue is a Cap) momentary obstruction, causing the differential ML220 GPHto( increase 7.6 LPH) greatly. (Red Cap) pressure7071 across the 2.0 orifice This pushes the particle through the expanding orifice. 6075 1.0 GPH ( 3.8 LPH) (Blue Cap) FD-2010 @ 15-100 PSI 2.0 GPH ( 7.6 LPH) (Red Cap) @ 15-100 PSI 3 The particle is then flushed orifice, End) NSG-06 6050 0.6 GPH through ( 2.3 LPH)the(Green which instantly returns to its normal size. Normal pressure6051 conditions1.0 areGPH restored. The particle NSG-10 ( 3.8 LPH) (Blue End) continues through the remaining orifices in the NSG-20 6053and out2.0 (Red End) GPHNonStop ( 7.6 LPH) diaphragm of the emitter. FD-2020 6080 NSG-30 6056 3.0 GPH ( 11.5 LPH) (Yellow End) NonStop Drip Emitters Nominal Performance 4.0 (15.1) Notes Flow, GPH (LPH) NonStop Drip Emitters • 30-mesh filtration and 15 PSI emitter operating pressure are the Notes recommended miniManufacturer’s varia-mums for a NonStop Models* Cv: ≤ 0.05 2.0 GPH Models* 1.0 GPHtion, emitter system. 3.0 Nominal Performance (11.4) Flow, GPH (LPH) 4.0 (15.1) 3.0 (11.4) 2.0 (7.6) 2.0 GPH Models* 2.0 (7.6) 1.0 (3.8) 1.0 GPH Models* 0 10 (0.69) 1.0 (3.8) 0 10 (0.69) 15 (1.03) 20 (1.38) Pressure, PSI (bars) 15 (1.03) 20 (1.38) Bowsmith, Inc. Pressure, PSI (bars) P.O. Box 428 • Exeter, CA 93221 USA DE01-0700 P.O. Box 428 • Exeter, CA 93221 USA Toll-Free USA: 1-(800) BOWSMITH 1-(800)-269-7648 P: (559) 592-9485 F: (559) 592-2314 www.bowsmith.com 30-mesh filtration and • Manufacturer’s PSI emitter operat0.6 GPH15 Models* variation, C v : ≤ 0.05 ing pressure are the 25 30minirecommended (1.72) (2.07) mums for a NonStop 0.6 GPH Models* *Nominal Flow at 20 PSI emitter system. 25 30 (1.72) (2.07) Toll-Free USA: *Nominal Flow at 20 PSI 1-(800) BOWSMITH 1-(800) 269-7648 (559) 592-9485; Fax: (559) 592-2314 www.bowsmith.com rev.121515 NonStop® Drip Emitters SB Series • Single outlet. • 0.175" O.D. or 0.250" O.D. inlet/outlet barb connections on opposite ends. Either can be used as outlet. • Accessories: riser or feeder tubing for extending the emitter away from the water supply. See the illustration, below. Stock No 6120 6121 6123 6124 Connection / Extension Options Model No. SB-06 (Green Insert) SB-10 (Blue Insert) SB-20 (Red Insert) SB-30 (Yellow Insert) Nominal Flow* 0.6 GPH (2.3 LPH) 1.0 GPH (3.8 LPH) 2.0 GPH (7.6 LPH) 3.0 GPH (11.4 LPH) * Nominal Flow @ 20 PSI Feeder Tube 0.220" O.D. x 0.160" I.D. 0.175" barb “SB”Series Emitter 0.250" barb Supply Tubing 0.175" barb “SB”Series Emitter 0.250" barb M200 Series • Six open outlets. Each maintains its own flow path . • 0.250" barb inlet. • Includes full set (6 each) of elbow/outlet caps, and line plugs. • One-piece elbow/outlet cap fixes position of elbow to prevent it from coming loose in application. 0.175” barb for secure attachment of spreader tubing. Stock No Model No. Nominal Flow* 7063 M206 0.6 GPH (2.3 LPH) 1.0 GPH (3.8 LPH) 2.0 GPH (7.6 LPH) 7064 7066 each open outlet (Green Cap) M210 (Blue Cap) M220 (Red Cap) * Nominal Flow @ 20 PSI • The elbow is easily reversed to cap off any unused outlets. • Line plugs can be placed in the end of the spreader tubes to help keep bugs out, but still allow passage of water. NonStop Drip Emitters Flow, GPH (LPH) Nominal Performance 4.0 (15.1) 3.0 (11.4) 2.0 (7.6) 1.0 (3.8) 0 10 (0.69) Notes 2.0 GPH Models* 1.0 GPH Models* 15 (1.03) 20 (1.38) P.O. Box 428 • Exeter, CA 93221 USA Toll-Free USA: 1-(800) BOWSMITH 1-(800)-269-7648 P: (559) 592-9485 F: (559) 592-2314 www.bowsmith.com 0.6 GPH Models* 25 30 Pressure, PSI (1.72) (2.07) (bars) • Manufacturer’s variation, Cv:≤ 0.05 • 30-mesh filtration and 15 PSI emitter operating pressure are the recommended minimums for a NonStop emitter system. rev.080615 NonStop® Drip Emitters Series 2000 Flow Distributor • Two devices in one: drip emitter and pressure regulator. Stock No Model No. Nominal Flow* 6075 FD-2010 6080 FD-2020 1.0 GPH (3.8 LPH) 2.0 GPH (7.6 LPH) • Pressure regulator operates on supply pressure from 15 to 100 PSI. • Pressure regulator valve uses durable, accurate stainless steel spring. • Six open outlets. Each maintains its own flow path. 1 • /2" FPT inlet. • Includes full set (6 each) of elbow/outlet caps, and line plugs. • One-piece elbow/outlet cap fixes position of elbow to prevent it from coming loose in application. 0.175” barb for secure attachment of spreader tubing. • The elbow is easily reversed to cap off any unused outlets. (Blue Cap) (Red Cap) TYPICAL INSTALLATION FINISH GRADE FLOW DISTRIBUTOR BOWSMITH MODEL SERIES 2000 (1/2" FPT FIELD INSTALLED AFTER FLUSHING WATER SYSTEM) • Line plugs can be placed in the end of the spreader tubes to help keep bugs out, but still allow passage of water. 1/2” MPT ADAPTER FLEX PVC RISER Flow, GPH (LPH) LAT. TEE OR 90° ELL 2.5 (9.5) 2.0 (7.6) 1.5 (5.7) 1.0 (3.8) 0.5 (1.9) 0.0 Model FD-2020 Model FD-2010 0 25 (1.72) 50 (3.45) 75 (5.17) 100 (6.89) Pressure, PSI (bars) P.O. Box 428 • Exeter, CA 93221 USA Toll-Free USA: 1-(800) BOWSMITH 1-(800)-269-7648 P: (559) 592-9485 F: (559) 592-2314 www.bowsmith.com rev.080615 NonStop® Drip Emitters SL200 Series • Barbed elbow outlet port for connecting spreader tubing, if desired. • Industry standard 1⁄ 2" FPT connection in cap. • Silicone O-ring inside cap for leak-free connections. • Constructed of tough engineering grade plastic with UV inhibitors. Stock No 6034 6035 6036 6037 Model No. SL206 (Green Port) SL210 (Blue Port) SL220 (Red Port) SL230 (Yellow Port) FINISH GRADE LAT. TEE OR ELL 0.6 GPH (2.3 LPH) 1.0 GPH (3.8 LPH) 2.0 GPH (7.6 LPH) 3.0 GPH (11.4 LPH) * Nominal Flow @ 20 PSI Installation Examples DRIP EMITTER BOWSMITH MODEL SL200 (1⁄ 2" FPT FIELD INSTALLED AFTER FLUSHING WATER SYSTEM) Nominal Flow* WATER BASIN INSTALLED AROUND PLANT PIT ROOTBALL OF SHRUB, GROUND COVER OR TREE BOWSMITH NonStop SL200 SERIES EMITTER DISTRIBUTION TUBING (CUTAWAY SHOWS BARB CONNECTOR AFTER FIELD INSTALLATION) BOWSMITH “SFT-12” ASSEMBLY (1/2”) RE-BAR J-HOOK 1/2" MPT ADAPTER / FLEX PVC RISER (CUTAWAY SHOWS EMITTER IN PLACE) 1/2” SCH 40 UVR PVC LATERAL LINES INSTALLED ON FINISHED GRADE FINISH GRADE ON SLOPE ML200 Series • Six open outlets. Each maintains its own flow path . • 1/2" FPT inlet. • Includes full set (6 each) of elbow/outlet caps, and line plugs. • One-piece elbow/outlet cap fixes position of elbow to prevent it from coming loose in application. 0.175” barb for secure attachment of spreader tubing. Stock No 7068 7069 7071 Model No. Nominal Flow* ML206 0.6 GPH (2.3 LPH) 1.0 GPH (3.8 LPH) 2.0 GPH (7.6 LPH) each open outlet (Green Cap) ML210 (Blue Cap) ML220 (Red Cap) * Nominal Flow @ 20 PSI • The elbow is easily reversed to cap off any unused outlets. • Line plugs can be placed in the end of the spreader tubes to help keep bugs out, but still allow passage of water. NonStop Drip Emitters Flow, GPH (LPH) Nominal Performance 4.0 (15.1) 3.0 (11.4) 2.0 (7.6) 1.0 (3.8) 0 10 (0.69) Notes 2.0 GPH Models* 1.0 GPH Models* 15 (1.03) 20 (1.38) 0.6 GPH Models* 25 30 Pressure, PSI (1.72) (2.07) (bars) • Manufacturer’s variation, Cv: ≤0.05 • 30-mesh filtration and 15 PSI emitter operating pressure are the recommended minimums for a NonStop emitter system. P.O. Box 428 • Exeter, CA 93221 USA Toll-Free USA: 1-(800) BOWSMITH 1-(800)-269-7648 P: (559) 592-9485 F: (559) 592-2314 www.bowsmith.com rev.080615 NonStop® Drip Emitters Typical Installation Examples TYPICAL INSTALLATION WATER BASIN INSTALLED AROUND PLANT PIT ROOTBALL OF SHRUB, GROUND COVER OR TREE REFER TO PLANTING PLANS FOR PLANTING DETAILS BOWSMITH NonStop SL200 SERIES EMITTER BOWSMITH “SFT-12” ASSEMBLY (1/2”) RE-BAR J-HOOK 1/2” SCH 40 UVR PVC LATERAL LINES INSTALLED ON FINISHED GRADE FINISHED GRADE ON SLOPE BOWSMITH “SUPER FLEX” TUBE ASSEMBLY BOWSMITH “SL200” EMITTER NOTE: DRIP EMITTER SHALL BE PLACED TO DROP 8”-12” UPHILL FROM ROOTBALL. PVC LATERAL SUPPLY LINES SHALL RUN PARALLEL TO SLOPE WITH DRIP EMITTER LINES RUN PERPENDICULAR TO SLOPE AS SHOWN ABOVE. P.O. Box 428 • Exeter, CA 93221 USA Toll-Free USA: 1-(800) BOWSMITH 1-(800)-269-7648 P: (559) 592-9485 F: (559) 592-2314 www.bowsmith.com rev.080615