Transcript
P R O D U C T C ATA L O G U E
A UTC Fire & Security Company
PAGE 1/120
www.kfp.co.uk
CONTENTS
ZOOM
PRINT
EXIT
KIDDE FIRE PROTECTION Kidde Fire Protection is a leading brand within Kidde Products. Kidde Products are part of UTC Fire & Security, which provides fire safety and security solutions to more than one million customers around the world. Headquartered in Connecticut, U.S., UTC Fire & Security is a business unit of United Technologies Corp., which provides high technology products and services to the building and aerospace industries worldwide. Kidde Fire Protection manufactures fire detection, and fire suppression systems in the UK providing product sales and customer support from our office in Thame, Oxfordshire. We do business in over one hundred countries throughout Europe, Africa, the Arbabian Gulf, Asia, South America and the Caribbean through an extensive network of over two hundred distributors. We also have local representation through Kidde sales offices around the world. Our Investor in People accreditation demonstrates that its high standards of quality are reflected not only in the excellence of its products, but also in the skills and motivation of people throughout the organisation. Many of our technical staff are acknowledged experts in their fields and are members of national and international standards committees such as NFPA, CEN and ISO. UTC Fire & Security maintains its position at the forefront of fire protection technology through continuous investment in research and development. Quality Management Systems which fully comply with the requirements of BS EN ISO 9001:2000 ensure that finished products will perform consistently and reliably. Sound practices at all Kidde Fire Protection manufacturing plants are designed to minimise environmental impact, by energy, raw materials and waste management. Kidde Fire Protection is a proud and active member of the Fire Industry Association (FIA).
2 2/120 PAGE
Tel: +44 (0)1844www.kfp.co.uk 265003
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
CONTENTS 2 4 6
Kidde Fire Protection United Technologies UTC Fire and Security CONTROL PANELS
10 16 22 25 26 29 31
Intelligent Addressable Fire Alarm Panels Vega Networking Systems Autroprime Custom Design Control Panels Conventional Fire Alarm Panels Extinguishing Control Systems FireBeta Status Indicators DETECTION AND ALARM
38 40 44 49 52 54 55 58 62 64 67 71 72 73 74 77 79
Detector types Discovery Intelligent Fire Detection XP95 Intelligent Fire Detection Intelligent Audio/Visual Signalling Standard Interfaces with Isolators Mini Interfaces Din-Rail Interfaces Orbis Conventional Fire Detection Mounting Accessories Test Equipment Conventional Audio/Visual Signalling Conventional Manual Call Points Door Release Equipment Sealed Lead Acid Batteries XP95 Intrinsically Safe Detectors Orbis IS Detector range Intrinsically Safe Audio/Visual Signalling ASPIRATING SMOKE DETECTION
84 86 88 98 103
Where to use High Sensitivty Smoke Detection How High Sensitivty Smoke Detection works SENATOR High Sensitivty Smoke Detection HART High Sensitivty Smoke Detection Sniffer Pipe ALARMLINE LINEAR HEAT DETECTION
108 110 112 114
Where to use Alarmline Linear Heat detection Alarmline Analogue Alarmline Digital Cable Alarmline Fixing Accessories
PAGE 3/120
www.kfp.co.uk
HOME
CONTENTS
ZOOM
PRINT
EXIT
3
UNITED TECHNOLOGIES United Technologies Corporation, based in Hartford, Connecticut, USA, is a diversified industrial company, with 225000 employees in more than 4000 locations worldwide, which serves the commercial building and aerospace industries. UTC’s business units comprise:
Sikorsky Military and commercial helicopters; fixed-wing aircraft; spare parts and maintenance, repair and overhaul services for helicopters and fixed-wing aircraft.
Carrier Heating, ventilation, air-conditioning and refrigeration systems; sustainable building solutions for residential, commercial, industrial and transportation applications. Hamilton Sundstrand Electrical power and distribution systems, flight control systems, pilot controls, propulsion systems, environmental control systems and fire protection products for aircraft and military ground vehicles. Otis Design, manufacture, installation, and service of elevators, escalators and moving walkways for commercial and residential buildings, multipurpose malls, educational institutions and urban transportation systems.
4 4/120 PAGE
Tel: +44 (0)1844www.kfp.co.uk 265003
Pratt & Whitney Engines for commercial and military aircraft and helicopters; regional, business and light jets. Land-based gas turbine and geothermal power solutions for industrial and utility markets.
UTC Fire & Security Electronic security and fire safety systems, software and services; design, integration, installation and servicing of access control, intruder alarm, video surveillance, and fire detection and suppression systems; monitoring, response and security personnel services. UTC Power Fuel cell systems for on-site power applications and transportation. 2008
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
PAGE 5/120
www.kfp.co.uk
HOME
CONTENTS
ZOOM
PRINT
EXIT
5
UTC FIRE & SECURITY A global leader in fire safety and security, UTC Fire & Security (UTCFS) delivers peace of mind to individuals and businesses throughout the world. In fire safety, UTCFS comprises a diverse portfolio of businesses, including residential and commercial portable fire extinguishers, detection & alarm, fire suppression, fire fighting equipment, specialty detection and combustion control.
Our brands include such well-known names as Angus Fire, Autronica, Chemetron, Det-tronics, Onity, Fenwal, Marioff, Red Hawk, Sicli, and many others. Some of the world’s most discriminating customers rely on UTCFS products, including the Eiffel Tower in Paris; and the historic Waldorf Astoria Hotel, 7 World Trade Center and Statue of Liberty in New York City; Westminster Abbey in London and the Beijing Olympic stadium in China.
In electronic security, our companies provide systems integration, installation and service of intruder alarms, access control system, digital video surveillance and recording devices. UTCFS companies serve a variety of customer segments including education, entertainment, financial services, government, healthcare, petrochemical oil and gas, telecommunications and utilities, marine and many others.
6 6/120 PAGE
Tel: +44 (0)1844www.kfp.co.uk 265003
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
PAGE 7/120
www.kfp.co.uk
HOME
CONTENTS
ZOOM
PRINT
EXIT
7
CONTROL PANELS
8 8/120 PAGE
Tel: +44 (0)1844www.kfp.co.uk 265003
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
A fire alarm control panel is the core part of any fire detection system, monitoring detection devices for alarm signals and activating the required sequence of events to ensure safe evacuation, notification to emergency services or operation of fire suppression equipment. Therefore it is important whichever system you select it provides the functionality, flexibility and reliability to ensure optimum performance. Kidde’s range of control panels are designed to meet the highest standards in fire protection. Conventional panels:
Intelligent Addressable control panels:
A simple and cost effective solution for small area applications which require minimal cause and effect, i.e. shops, clinics, schools etc.
Microprocessor based distributed intelligence enables systems to be tailored to the exact requirements of a wide range of system configurations.
Conventional panels operate using zonal principles where detection devices are allocated to a dedicated circuit which will cover a specific area identified as a detection zone.
Intelligent addressable control panels operate using detection loops distributed throughout the protected building. Each loop device is provided with a unique address enabling accurate location of a fire. Extinguishing control panels: Based around a conventional control panel it is provided with additional features and functionality to control the safe operation of fire suppression systems.
PAGE 9/120
www.kfp.co.uk
HOME
CONTENTS
ZOOM
PRINT
EXIT
9
INTELLIGENT ADDRESSABLE FIRE ALARM PANELS
VEGA INTELLIGENT ADDRESSABLE CONTROL PANEL
INTELLIGENT ADDRESSABLE Fire Alarm Panels Kidde Fire Protections range of addressable control panels represent the ultimate in detection and alarm technology. Microprocessor based distributed intelligence enables systems to be tailored to the exact requirements of a wide range of system configurations. Offering flexibility in design and operation, Kidde panels are ideal for installation in many applications: • • • • • • •
Hotels Office complexes Manufacturing sites Hospitals Schools Residential complexes Commercial complexes
1010/120 PAGE
Tel: +44 (0)1844www.kfp.co.uk 265003
Vega is an open protocol control panel which is compatible with Apollo XP95/Discovery and Hochiki ESP devices. The Vega panel is expandable from 1 to 16 loops in single loop increments. An 8 line 40 Character LCD allows ease of on site programmability, with clear information relating to fire and fault conditions. Zonal LED indications for fire and fault support the information provided on the LCD, with the panel available in 24, 56, 88 or 120 zone versions. Vega incorporates many control features through the keys provided on the front membrane – Silence Buzzer, Silence Alarms, Reset, Delay override, Evacuate and numeric keys 0-9. Three password protected access levels restrict operation and programming of the system to the relevant authorised personnel. A range of software features are provided to minimise the possibility of false alarms including day mode, programmable time delays and investigation timers which allow the user time to investigate the incident before a full alarm is raised. Monitored sounder outputs and volt free relay outputs are provided on the control panel, the number will vary depending on the number of loops. Vega supports an extensive range of options including printer facility, repeater panels, plug-in option cards and networking capabilities.
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
Engineer features: • • • • • • • •
Forward and reverse loop scan enables easy location of open or short circuit faults Autolearn allows new loop configurations to be recognised Panel test enables visual and audible indications to be tested Device test enables electronic testing of individual loop devices Output group test enables verification of output programming Alarm simulation test combines the device and output group test options, to check alarm cause and effects Device fault codes assist with fault finding from panel location Event log stores a maximum of 512 events
Relay outputs
Programmable volt free changeover relay contacts rated 1A @ 30V dc 1-4 Loop panel – 4 x Relay contacts 5-8 Loop panel – 8 x Relay contacts 9-12 Loop panel – 12 x Relay contacts 13-16 Loop panel – 16 x Relay contacts Optional 8 way relay card available for expansion
Repeater output
Optional repeater card available, RS485 communication
Power supply
110 – 270V ac mains input voltage sensing Temperature monitored battery charging 2.5 Amp, 4 Amp or 8 Amp power supplies available
Current consumption
1 loop control panel -
The Vega range is provided in a number of standard panel configurations, although the modular configuration of the Vega enables unique panel specifications to be created on request. Technical specification
4 Loop control panel No. of detection loops
1-16 Loops, Max current per loop 220mA
Display
8 x 40 Character LCD, backlit with adjustable viewing
Indications
14 Status indications defined by EN45 part 2 Zonal fire and fault indications, 24, 56, 88 and 120 zone options. 64 Plant LED indications (Optional)
8 Loop control panel 16 Loop control panel -
Sounder outputs
PAGE 11/120
Programmable sounder outputs rated 1 Amp @ 17 to 28.5 Volts dc 1-4 Loop panel – 4 x Sounder circuits 5-8 Loop panel – 8 x Sounder circuits 9-12 Loop panel – 12 Sounder circuits 13-16 Loop panel – 16 Sounder circuits Optional 8 way sounder card available for expansion
www.kfp.co.uk
Quiescent: Alarm: Quiescent : Alarm: Quiescent: Alarm: Quiescent: Alarm:
350mA 730mA 570mA 940mA 800mA 1100mA 1800mA 2400mA
Service port
RS232 DIN socket for connecting to PC
Physical dimensions
1-4 Loop panel: 500W x 400H x 155D 5-8 Loop panel: 500W x 550H x 225D 9-16 Loop panel: 1000W x 550H x 225D
Enclosure
Mild steel, surface mount, Semi gloss ash grey BS4800 00A01 IP rating: 30 20mm pre-formed knockouts top and bottom
HOME
CONTENTS
ZOOM
PRINT
EXIT
11
INTELLIGENT ADDRESSABLE FIRE ALARM PANELS
Standard panel part numbers:
Standard panel range
Vega panel part numbers are a sequence of numbers and letters which detail the panel configuration e.g.
Note: Add ‘A’ for Apollo or ‘E’ for Hochiki ESP in place of the * in the part number. V01/1/024/*/2
1 Loop Vega, 24 Zone, 2.5 Amp power supply
V01/1/024/*/2/P 1 Loop Vega, 24 Zone, 2.5 Amp power supply, Printer V01/1/024/*/4
V06/2/056/A/4/P
1 Loop Vega, 24 Zone, 4 Amp power supply
V01/1/024/*/4/P 1 Loop Vega, 24 Zone, 4 Amp power supply, Printer V02/1/024/*/2
2 Loop Vega, 24 Zone, 2.5 Amp power supply
V02/1/024/*/2/P 2 Loop Vega, 24 Zone, 2.5 Amp power supply, Printer Denotes the panel is fitted with a Thermal Event Printer
Denotes the number of loops i.e. V06 is a 6 loop Vega, V02 is a 2 loop Vega etc.
V02/1/024/*/4
V02/1/024/*/4/P 2 Loop Vega, 24 Zone, 4 Amp power supply, Printer V03/1/024/*/2
Denotes box size 1 = 400 x 500 x 155 2 = 550 x 500 x 155 3 = 550 x 500 x 225 4 = 550 x 1000 x 225
Denotes PSU size. 2 = 2.5A PSU 4 = 4A PSU 8 = 8A PSU
3 Loop Vega, 24 Zone, 2.5 Amp power supply
V03/1/024/*/2/P 3 Loop Vega, 24 Zone, 2.5 Amp power supply, Printer V03/1/024/*/4
3 Loop Vega, 24 Zone, 4 Amp power supply
V03/1/024/*/4/P 3 Loop Vega, 24 Zone, 4 Amp power supply, Printer V04/1/024/*/2
Denotes panel protocol A = Apollo XP95/Discovery E = Hochiki ESP
2 Loop Vega, 24 Zone, 4 Amp power supply
4 Loop Vega, 24 Zone, 2.5 Amp power supply
V04/1/024/*/2/P 4 Loop Vega, 24 Zone, 2.5 Amp power supply, Printer V04/1/024/*/4
4 Loop Vega, 24 Zone, 4 Amp power supply
V04/1/024/*/4/P 4 Loop Vega, 24 Zone, 4 Amp power supply, Printer Denotes number of Zone indications. 024 = 24 Zone indications 056 = 56 Zone indications 088 = 88 Zone indications 120 = 120 Zone indications
V04/2/056/*/4/P 4 Loop Vega, 56 Zone, 4 Amp power supply, Printer V05/3/056/*/4/P 5 Loop Vega, 56 Zone, 4 Amp power supply, Printer V06/3/056/*/4/P 6 Loop Vega, 56 Zone, 4 Amp power supply, Printer V07/3/056/*/4/P 7 Loop Vega, 56 Zone, 4 Amp power supply, Printer V08/3/056/*/4/P 8 Loop Vega, 56 Zone, 4 Amp power supply, Printer V12/4/088/*/8/P 12 Loop Vega, 88 Zone, 8 Amp power supply, Printer V16/4/120/*/8/P 16 Loop Vega, 120 Zone, 8 Amp power supply, Printer
1212/120 PAGE
Tel: +44 (0)1844www.kfp.co.uk 265003
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
VEGA LT
VEGA OPTION CARD MOTHERBOARD
Vega LT intelligent addressable fire alarm control panel provides the same system functionality as the standard Vega panel in a cost-effective package for smaller fire system configurations. Developed using the existing hardware and software platforms of the highly successful Vega range, Vega LT delivers high performance at a competitive price for users who require a one or two loop intelligent addressable panel.
Vega motherboards can be installed within the Vega control panel or located remotely in a Vega interface enclosure. Each motherboard allows up to 4 plug-in option cards to be connected to the Vega control panel. Up to 4 motherboards can be connected to a single Vega control panel providing slots for up to 16 plug-in option cards in total.
Features • Single loop panel – upgradeable to Two loops • Supports Apollo XP95/Discovery and Hochiki ESP protocols • 8 Line 40 Character display, back lit • 16 Zonal indications • Programmable Alarm and Relay outputs • Compatible with VR3000 repeater panel Technical specification No. of detection loops
1 loop, additional loop can be added
Display
8 x 40 Character LCD, backlit with adjustable viewing
Indications
Status indications defined by EN54 part 2, 16 x Zone indications
Sounder outputs
2 x Programmable sounder outputs rated 1 Amp @ 24 Volts dc nominal
Relay outputs
2 x Programmable volt free changeover relay contacts rated 1A @ 24V dc
Repeater output
Optional repeater card available, RS485 communication
Power supply
2.5 Amp @ 24V dc 110 – 270V ac mains input voltage sensing Temperature monitored battery charging
Current consumption
Quiescent: 350mA
Service port
RS232 DIN socket for connecting to PC
Alarm: 730mA
LT2000
Single loop control panel – Apollo protocol
LT2001
Single loop control panel – Hochiki protocol
PAGE 13/120
www.kfp.co.uk
44782-K091
Vega option card motherboard
VEGA 8 WAY RELAY OUTPUT CARD This card provides additional programmable volt free relay outputs on the Vega control panel. Volt free relay contacts can be used to either operate other equipment i.e. to close fire dampers etc or provide alarm signalling to other systems such as a BMS. Relay outputs are rated 1 Amp @ 30V dc and can be individually configured as normally open or normally closed in operation. 44782-K092
Vega 8 way relay output card
VEGA 8 WAY MONITORED OUTPUT CARD This card provides an additional 8 individually programmable monitored outputs which can be used for operating audible and visual devices, as well as solenoid devices. Each output is individually fused and rated 1 amp at 28 volts dc.
44782-K093
HOME
Vega 8 way monitored output card
CONTENTS
ZOOM
PRINT
EXIT
13
INTELLIGENT ADDRESSABLE FIRE ALARM PANELS
VEGA 16 WAY NON-MONITORED INPUT CARD
VEGA REPEATER PANELS
This card provides 16 individually programmable non-monitored inputs. These inputs provide the facility for monitoring the operation of switched contacts either from a relay or a keyswitch. Each input of the card requires a 0 volt to be either applied or removed for activation, this can be selected individually for each input using DIL switches on the PCB.
To complement the Vega control panels, a versatile range of repeaters are available which will allow remote indication and operation of the fire alarm system.
44782-K094
Vega 16 way non-monitored input card
Repeaters are provided with an 8 line 40 character LCD and with or without zonal indications. They can be configured as passive (without user controls) or Active (with user controls) a maximum of 64 repeaters can be connected to a single Vega control panel of which 15 can be active and 49 can be passive. Note: Controlling Vega panel must be fitted with repeater output card.
VEGA 16 WAY NON-MONITORED OUTPUT CARD This card provides 16 individually programmable open collector outputs. Commonly used for driving LED’s on a mimic panel, they can also be used to trigger the switching of relays. Each output of the card provides 0-volt signal on activation.
44782-K095
Vega 16 way non-monitored output card
Features: • 24, 56, 88 and 120 zone indication variants • Integral power supply • Alarm sounder output • Volt free changeover relay contacts for Fire and Fault conditions • Internal panel buzzer • Status indications • Active repeater controls: Silence, Reset, Delay Override, Silence Alarms, Evacuate, Scroll, Numeric keys, Cursor keys • Optional event printer Technical specification Display
VEGA 8 WAY MONITORED INTPUT CARD This card provides 8 individually programmable monitored inputs. The inputs can be used for monitoring zones of conventional detectors as well as any devices which provide a volt free switched output. 44782-K096
1414/120 PAGE
Vega 8 way monitored input card
Tel: +44 (0)1844www.kfp.co.uk 265003
8 x 40 Character LCD, backlit with adjustable viewing
Indications
14 Status indications defined by ENS4 part 2 Zonal fire and fault indications, 24, 56, 88 and 120 zone options.
Sounder outputs
1 x Sounder output rated 1 Amp @ 17 to 28.5 Volts dc
Relay outputs
Fire and Fault volt free changeover relay contacts rated 1A @ 30V dc
Power supply
2.5 Amp power supply 110v – 270v ac mains input, voltage sensing
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
VEGA REPEATER OUTPUT CARD
Current
LCD only repeater - Quiescent Alarm Zonal repeater Quiescent Alarm
Physical dimensions
LCD only repeater24 Zone repeater 56 Zone repeater 88 Zone repeater 120 Zone repeater -
Enclosure
90mA 120mA 120mA 170mA
550W x 280H x 140D 500W x 400H x 140D 500W x 550H x 140D 500W x 700H x 140D 500W x 850H x 155D
Mild steel, surface mount, Semi gloss ash grey BS4800 00A01 IP rating: 30 20mm pre-formed knockouts top and bottom
To enable the Vega repeaters to communicate with the Vega control panels a repeater output card is required. This card plugs into the Vega Master Basic Loop Controller and provides the RS485 communications to the repeater panels. 44782-K076
VEGA OPTIONAL ACCESSORIES VEGA INTERFACE BOXES Two interface boxes are available which can be used to house Vega motherboards and plug-in option cards. This allows the boards to be installed up to 1km from the Vega control panel. The interface boxes are provided in two sizes accommodating either 2 or 4 Vega motherboards. Dimensions:
VR3000
Repeater LCD Only
VR3000P Repeater LCD Only with printer VR3024
Repeater LCD 24 Zonal indications
VR3024P Repeater LCD 24 Zonal indications with printer VR3056
Repeater LCD 56 Zonal indications
VR3056P Repeater LCD 56 Zonal indications with printer VR3088
Repeater LCD 88 Zonal indications
Vega Repeater Output card
500W x 400H x 155D 500W x 550H x 225D
VN4155
Vega Interface box c/w space for 2 x Motherboards
VN5225
Vega Interface box c/w space for 4 x Motherboards
VEGA FLUSH MOUNTING BEZELS A range of flush mounting bezels are available to fit Vega control panels, repeaters and interface enclosures. The bezels allow the enclosures to be recessed into a wall providing an aesthetically pleasing installation for reception areas, foyers etc. Bezels are manufactured from mild steel, paint colour is semi gloss ash grey to match the enclosures.
VR3088P Repeater LCD 88 Zonal indications with printer
35100-K080
Flush mounting bezel to fit enclosure 500W x 400H
VR3120
35100-K098
Flush mounting bezel to fit enclosure 500W x 250H
35100-K099
Flush mounting bezel to fit enclosure 500W x 550H
Repeater LCD 120 Zonal indications
VR3120P Repeater LCD 120 Zonal indications with printer
PAGE 15/120
www.kfp.co.uk
HOME
CONTENTS
ZOOM
PRINT
EXIT
15
INTELLIGENT ADDRESSABLE FIRE ALARM PANELS
VEGA Networking Systems
VEGA CONFIGURATION SOFTWARE Viper is a software programme required for configuring the Vega control panel. A number of versions are available depending on the version of processor software installed in the Vega panel. All panels are despatched with a CD containing the current Viper software. It is recommended before using Viper to check with our technical department that you have the correct version to suit your control panel. This software is compatible with Windows versions up to Windows Xp. D28300-3xx
Viper software
D28320-1xx
Viper software for Vega CZN panels
Where a fire system or site installation demands the use of more than one Kidde Vega panel, a communication network link can provide the tailor made engineering solution for most applications, from a simple two panel system to a multi-panel networked site-wide installation. Kidde offers two types of network to compliment its Vega range: • •
Common Zone Networking (CZN) VegaNET
Note: xx would be replaced by the version number
VEGA COMMON ZONE NETWORKING (CZN) Common Zone Network (CZN) enables up to 32 Vega stand alone systems to be connected together providing site wide fire alarm monitoring for small, medium and large sized establishments or multi-building sites. CZN supports the full range of Vega control panels providing a flexible approach to system design that can address the many different alarm reporting, and evacuation strategies required for buildings of today. CZN integrated solution, provides the site fire team or designated personnel with instantaneous location of fire alarm incidents saving valuable search and response time. CZN concept is based upon a shared common zone principle, where the maximum number of geographical fire compartment zones does not exceed 120. The system configuration can be programmed to conform to two basic operating applications.
1616/120 PAGE
Tel: +44 (0)1844www.kfp.co.uk 265003
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
VEGA CZN NETWORK OPTION •
Master\Slave –
satellite panels display local information and transmit alarm data to master panels, which display site wide alarm information.
•
Multi-Master –
each satellite panel displays site wide alarm information.
Features • Up to 32 Vega panels form a site network • 120 site wide ‘Fire’ zones incorporating zone offset facility • 64 site wide ‘Plant’ indications • BGU override and co-incidence voting between panels • Comprehensive site wide cause and effect control • Isolate zones and common output groups from any panel on the network • RS422 Communications allow up to 1 Km between control panels
PAGE 17/120
www.kfp.co.uk
Vega panels can easily be upgraded on site to provide a CZN network by installation of the Vega CZN network option. This consists of a ‘527’ network card including latest software EPROM, mounting plate, cable harnesses and upgrade software EPROM’s for the panel Main Control Processor.
VN2105
Vega CZN network option – Vega
VN2108
Vega CZN network option – Vega LT
CZN EXAMPLE
HOME
CONTENTS
ZOOM
PRINT
EXIT
17
INTELLIGENT ADDRESSABLE FIRE ALARM PANELS
VEGANET DISPLAY SYSTEM
VegaNET Display System is a PC Windows™ based application designed primarily for the monitoring of fire alarm systems. VegaNET provides the user with a means to view the entire system enabling rapid recognition, identification of source and extent of each event, particularly during multiple alarm conditions. The presentation of alarm information is provided in a simple, standard text or graphical format, giving operators the right information on which to make appropriate decisions. VegaNET Display System is designed specifically for connecting to the Kidde range of fire detection panels providing full interrogation of sophisticated features. Powerful network cards located within each fire control panel enable up to 32 remote panels to be supervised. This provides the operator with an instantaneous overview of all systems with immediate access to detailed information as required. Alternatively, using network outstations incorporated within the system design, monitoring of third party equipment via discrete digital inputs can be achieved. VegaNET Display System provides central control and monitoring for remote sector nodes using full-duplex transfer of information, status and commands over a networked system. The system allows each alarm device or input to be allocated a priority, which ensures that the operator is presented with the most urgent high priority alarms, followed by those of lesser importance. Monitoring of non fire related events such as plant, security, and process are also catered for by the system. Features • Available as Text or Graphic versions • Prominent user controls with attractive appearance • Print graphical pages with automatic event logging • Multi-level password protection • Unlimited number of graphical pages • Language text translations • Up to 32 (Nodes) Vega panels or outstations per network • Up to 6 computers running VegaNET connected to network • Up to 6 network repeaters and geographic mimics • Can connect 6 networks together providing 192 node capability
1818/120 PAGE
Tel: +44 (0)1844www.kfp.co.uk 265003
VEGANET EXAMPLE
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
VEGANET IN ACTION
VEGANET DISPLAY SYSTEMS TERMINALS A complete package containing everything needed to provide a VegaNET text or graphic reporting terminal. This package includes: •
Overview page Showing location of building in alarm
Level 1 page Showing building floor level in alarm
• • •
Computer pre-installed with VegaNET Text or Graphics reporting software PC minimum specification: Intel Pentium 4, 3Ghz processor, 1GB 533Mhz DDR2SDRAM memory, 160Gb Hard Disk Drive, 17” Flat panel monitor, DVD +/-RW drive, USB keyboard and mouse, Serial and Parallel ports & PS2 adaptor, Windows XP operating system Text or Graphic reporting system application CD and run time module Deskjet printer Network Control Unit
Note: The specification of the PC and its ancillaries are subject to change without notification
Level 2 page Defining location of detector in alarm
VN3000
VegaNET Display system package – Text reporting
VN3001
VegaNET Display system package – Graphics reporting
VegaNET software can be purchased separately VN2000
VegaNET text reporting software
VN2101
VegaNET graphics reporting software
Text message window Provides device location user intervention details
Sector interrogate facility Enables user to control remote sector panels
PAGE 19/120
www.kfp.co.uk
HOME
CONTENTS
ZOOM
PRINT
EXIT
19
INTELLIGENT ADDRESSABLE FIRE ALARM PANELS
VEGANET NETWORK OPTION
VEGANET NETWORK REPEATER
Vega panels can easily be upgraded on site to provide a VegaNET network by installation of the VegaNET network option. This consists of a ‘527’ network card including latest software EPROM, mounting plate, cable harnesses and upgrade software EPROM’s for the panel main control processor.
Network repeaters provide simple, high priority alarm text messages for an entire VegaNet network of fire alarm panels or outstations. Up to 6 network repeaters can be connected to the VegaNet network system. The repeaters can be extended to support open collector outputs for LED mimic displays. The Network repeater can be configured with or without user controls and has an optional printer.
VN2104
VegaNET Network option – VEGA
VN2107
VegaNET Network option – VEGA LT
Technical specification Display
VEGANET NETWORK CONTROL UNIT For each PC running VegaNET software a Network Control Unit is required to interface the PC to the Vega panel network. Technical specification Power supply input
85-264Vac, 47-440Hz
Enclosure
Surface mount mild steel, Semi gloss ash grey
Dimensions
440W x 226H x 115D
VN2100
2020/120 PAGE
8 Line 40 Character LCD
Sounder circuits
4 x Common sounder circuits, rated 1 Amp @ 24V dc will activate on any alarm
Relay outputs
4 x Volt free changeover contacts, rated 1 Amp @ 24V dc will activate on any alarm
Power supply
2.5 Amp @ 24V dc 110 – 270V ac mains input voltage sensing Temperature monitored battery charging
Enclosure
Surface mount mild steel, Semi gloss ash grey, IP30
Dimensions
500W x 400H x 155D
VN2109
VegaNET Network repeater
VN2109P
VegaNET Network repeater with printer
VegaNET Network Control Unit
Tel: +44 (0)1844www.kfp.co.uk 265003
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
VEGANET RADIAL EXPANDER The Radial Expander has been designed to enable network communications to be spurred allowing site cabling to be reduced. This unit can also be used as a line booster to increase the communication cable distance between network cards by a further 1km. There is no limit to the quantity of Radial Expander units that can be accommodated within one system design. The Radial expander allows a single network input to be spurred into 4 network outputs. Power supply
2.5 Amp @ 24V dc 110 – 270V ac mains input voltage sensing Temperature monitored battery charging
Enclosure
Surface mount mild steel, Semi gloss ash grey, IP30
Dimensions
440W x 266H x 115D
VN2103
VegaNET Radial Expander
VEGANET NETWORK OUTSTATION It is possible to monitor third party equipment via discrete digital inputs across a VegaNET network. The network outstation is an interface enclosure containing a network card Vega Motherboard and either monitored or non-monitored input cards. Signals can be monitored via the input cards and transmitted across the VegaNET network. VegaNET network outstations are custom built on request.
PAGE 21/120
www.kfp.co.uk
HOME
CONTENTS
ZOOM
PRINT
EXIT
21
INTELLIGENT ADDRESSABLE FIRE ALARM PANELS
AUTROPRIME The Fire Alarm Control Panel supports 2 detection loops and most Autrosafe detectors, several types of I/O devices for monitored outputs, open collector outputs, galvanic isolated inputs and monitored inputs. All loop units can be mixed freely and connected at any point on the same detection loop. A maximum of 8 additional panels can be freely mixed and connected to the Fire Alarm Control Panel via the RS-485 panel bus, including Repeater Panels, Information Panels, Fire Brigade Panels and Mimic Drivers. The panel is menu operated on an 8-line display, with 40 characters per line. The Operator Panel, which is an integrated part of the Autroprime panel, can also be mounted separately outside the cabinet. Autroprime complies with C.E.N. EN 54 regulations, FM regulations (Factory Mutual).
Autroprime Interactive Fire Detection System is a stand-alone fire detection system for small-tomedium sized applications. Autroprime brings simplicity, quality, cost-effectiveness and extensive functionality in one integrated system. Plug and play Autroprime is provided to the user in a pre-configured state. In this state the panel is set to automatically recognise detectors and other loop units connected to the detection loops and the availability of routing equipment, etc. As such, the system is fully functional and ready-to-use after a few minutes, simply by turning the power ON. Further site-specific configuration can easily be performed if necessary. The system uses SelfVerify functionality to ensure that the system will work according to regulations every single day. Furthermore, the system will inform the user when detectors need maintenance, ensuring optimised life-cycle cost.
2222/120 PAGE
Tel: +44 (0)1844www.kfp.co.uk 265003
Features • SelfVerify ® function for automatic testing of detectors • Automatic setup • Automatic addressing of detectors • Two loops • USB for data transfer to/from memory stick • User-friendly display and operator controls • Back-lit operating buttons. Text display suitable for night-time operation • Surface mounting • Designed to meet EN 54 requirements and conforms to CE standards • Complies with environmental conditions of IEC-721-3-3 class 3k5
BS-200
Autroprime Fire Control Panel
BS-211
Autroprime Repeater Panel
BU-210
Autroprime Fire Brigade Panel
BV-210
Autroprime Information Panel
BUR-200
Autroprime Mimic Driver
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
AUTROPRIME LOOP INTERFACES
AUTROPRIME DETECTORS
BN-201
Monitoring input unit
BDH-200
Heat detector
BN-300
Fire Alarm input unit with self verify
BDH-300
Heat detector with self verify
BN-310
Relay output unit with self verify
BDH-500
Heat detector, Self verify, IP44D, environmentally sealed
BNA-320/02
Interface board for BN310
BD-501
Heat detector inc. base, Self verify, IP56
BN-320
I/O unit with self verify
BDH-500/EX
Heat detector, Self verify, IP44D for use in Ex areas, environmentally sealed
BN320/2
Door control unit with self verify
BHH-200
Optical smoke detector
BN-320/4
Monitoring and control unit with self verify
BHH-300
Optical smoke detector with Self verify
BN-320/5
Sprinkler control system with self verify
BHH-500
Optical smoke detector with Self verify, High risk version
BN-330
Interface for conventional detection loops with self verify
BHH-500/EX
Optical smoke detector with Self verify, Exi version
BN-500/EX
Input unit for Zone 0, 1 & 2 with self verify
BHH-220
Multisensor detector
BN-40A/3
Loop interface unit for Autrobeam 100 with self verify
BHH-320
Multisensor detector with self verify
BNA-320-01
Interface board for BN-40A/3
BHH-520
Multisensor detector with self verify, High risk version
BNB-300/32
Interface module
BHH-520/EX
Multisensor detector with self verify, Exi version
BW-200
Disable unit with push buttons
BHH-502/N
Multisensor detector with self verify, Ex zone 2 use only
BW-201
Disable unit with timer input
BU-200
Remote alarm control unit
BZ-500
Ex-barrier unit, Exia IIC
PAGE 23/120
www.kfp.co.uk
HOME
CONTENTS
ZOOM
PRINT
EXIT
23
INTELLIGENT ADDRESSABLE FIRE ALARM PANELS
AUTROPRIME MANUAL CALL POINTS
AUTROPRIME INSTALLATION ACCESSORIES
BF-300
Manual Call Point with self verify
BWA-101
Detector base with microswitch
BF-300M/N
Manual Call Point with self verify, Ex zone 2
WBW-100
Coupling unit for detector base
BF-500/EX
Manual Call Point with self verify, Exi version
WBW-101
Detector mounting plate for false ceiling
BF-501
Manual Call Point with self verify, IP66, without LED
BWP-145
Detector base with heat element
BF-501/EX
Manual Call Point with self verify, IP66, Exi version
BWP-100/20
Conduit box 4 x M20
BF-501/N
Manual Call Point, IP66, Ex zone 2
BWP-100/25
Conduit box 4 x M25
BF-502
Manual Call Point with self verify, IP66
BPW-143/150
Canal adaptor 150mm inc. socket
BF-502/EX
Manual Call Point with self verify, IP66, Exi version
BPW-143/300
Canal adaptor 300mm inc. socket
BF-502/N
Manual Call Point with self verify, IP66, Ex zone 2
BPW-143/550
Canal adaptor 550mm inc. socket
AUTROPRIME ADDRESSABLE AUDIO/VISUAL DEVICES BBR-130
Base sounder, Red, 90dBA
BBR-230
Sounder, Red, 100dBA
BBR-230/IP
Sounder, Red, IP65, 100dBA
BBQ-130
Base sounder with beacon, 90dBA
BBQ-230
Sounder/Beacon, Red, I00dBA
BBQ-230/IP
Sounder/Beacon, Red, IP65, 100dBA
2424/120 PAGE
Tel: +44 (0)1844www.kfp.co.uk 265003
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
Custom designed panels supplied on previous projects include:
CUSTOM DESIGN Control panels Meeting our customers requirements is imperative when it comes to fire alarm systems. For over 15 years Kidde have supplied custom design panels based around our standard range of equipment.
• • • • •
Special colour control panels Geographic LED mimics 19” Rack mount panels Floor standing enclosures incorporating fire and gas detection control systems Combined fire detection and multi –area suppression control panels
If you have a special requirement, then it will be necessary to contact your sales representative who will be more than happy to discuss your requirements with you.
3 x Custom built Vega control panels in a 2m high 19” rack type cabinet. Each panel has 16 detection loops, 120 detection zones, 4 x 8 way sounder cards, 4 x 8 way relay cards and event printer. Designed for a Power Station project.
PAGE 25/120
www.kfp.co.uk
HOME
CONTENTS
ZOOM
PRINT
EXIT
25
INTELLIGENT ADDRESSABLE FIRE ALARM PANELS
SIRIUS II CONVENTIONAL FIRE ALARM CONTROL PANEL
CONVENTIONAL Fire Alarm Panels Conventional Fire Alarm control panels provide cost effective fire engineering solutions for small area applications which require minimal cause and effect: Shops, Clinics, Schools, Telecommunications Conventional systems are wired as circuits or ‘zones’ with a zone being an area of maximum 2000m2, panels are supplied with a varying number of detection zones. Detection devices connected to the detection zone circuits operate on a simple two state basis, either ‘on’ or ‘off’ i.e. ‘Alarm’ or ‘No alarm’. The conventional control panel monitors the state of these devices, determines whether the device is in alarm and provides a general alarm signal to operate visual and audible warning devices to notify personnel within the building. The Kidde Sirius II conventional fire alarm control panel has been designed with simplicity of operation and attractive appearance in mind. Sirius II is compatible with a wide range of detectors making it ideal for retro-installations.
A cost effective fire alarm control panel approved to EN54 parts 2 and 4. The Sirius II is available in 2, 4 or 8 Zone options. User friendly operation allows the panel to be configured through the membrane keys. LED indications and an LCD provides clear information regarding the panel status. The Sirius II has a range of accessories including repeaters and option cards to provide flexibility in system design. Features: • • • • • • • • • • • • • • •
Integral zone detector removal with short and open circuit monitoring (no AEOL device) Code access (No keys to lose) Wide range of detectors supported i.e. Apollo, Hochiki and Nittan A wide range of warning devices supported e.g. electronic sounders, bells, beacons etc. Each zone supports up to 32 detectors and unlimited number of call points 2 x alarm circuits as standard, rated 1 A @ 28 V dc Fire and Fault relay outputs 1 x Monitored Fire Output with disable function rated 0.5 A @28 V dc* Integral 2.5A Switch Mode Power Supply incorporating intelligent battery monitoring One man walk test Zone disable function Programmable zone co-incidence Programmable sounder functions Real time clock /alarm counter RS485 Repeater network*
* not available on 2 zone variant
SE2000 Sirius II 2000 - 2 Zone panel SE4000 Sirius II 4000 - 4 Zone panel SE8000 Sirius II 8000 - 8 Zone panel
2626/120 PAGE
Tel: +44 (0)1844www.kfp.co.uk 265003
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
SIRIUS II REPEATER PANEL
SIRIUS II 8-WAY SOUNDER OUTPUT BOARD
Sirius II Repeater panel provides remote indication and controls for the Sirius II, 4 and 8 zone conventional fire alarm panels. Repeater panels can be configured as passive (indication only) or active (Indication and minimal controls), up to 7 active and 7 passive repeaters can be connected to a Sirius II control panel.
Sirius II 8-Way Sounder Output board provides the facility to expand the number of sounder circuits on a Sirius II control panel. The Sounder board is compatible with the 4 and 8 zone variants only. Each sounder circuit is rated at 250mA, and is provided with an LED indication to show operation.
Features:
• • • •
• • • • • • •
8 Zonal fire indications RS485 communication with control panel Common Fire and Fault relay outputs 18-28V dc supply Power Supply Monitor fault input Switched 0v Zonal outputs User controls – Silence/Resound Alarms, Panel Reset, Silence Buzzer, Delay Override, Panel access
8 monitored outputs RS485 Communications Up to seven boards connected to a single panel Fault relay output 44782-K173 Sirius II 8-Way Sounder Output board
SR8500 Sirius II Repeater panel
PAGE 27/120
www.kfp.co.uk
HOME
CONTENTS
ZOOM
PRINT
EXIT
27
INTELLIGENT ADDRESSABLE FIRE ALARM PANELS
SIRIUS II 8-WAY RELAY OUTPUT BOARD
SIRIUS II INPUT/OUTPUT BOARD
Sirius II 8-Way Relay Output board provides the facility to expand the number of relay outputs on a Sirius II control panel. The relay output board is compatible with the 4 and 8 zone variants only.
Sirius II Input/Output board provides eight monitored inputs and eight corresponding volt free relay outputs. The inputs can be used to monitor the status of other equipment within the site, on receiving a signal from the monitored circuit the corresponding output can be operated which can be used for signalling or operation of other equipment.
The relay outputs can be configured for various panel conditions:
The outputs can be set to operate in either of two modes, Mode 1 – On input circuit active, Mode 2 – On input circuit fault. LED’s are provided to indicate the status of the individual inputs and outputs.
Zonal Fire Zonal Fault – Non latching Zonal Fault – Latching Zone Disabled Panel outputs Clear processor fault
• • •
When configured for panel outputs the relays will be individually allocated to indicate the following status conditions: Output 1 - General Fire Output 2 - General Fault Output 3 – General Test Output 4 – General Disablement Output 5 – Silence Alarms Output 6 – System reset Output 7 – Evacuate Output 8 – Class change • • • •
RS485 Communications Fault relay output Output relays, rated 1A
44782-K175 Sirius II Input/Output board
8 Relay outputs, rated 1A RS485 Communications Up to 7 boards can be connected to a single panel Fault relay output 44782-K174 Sirius II 8-Way Relay Output board
2828/120 PAGE
Tel: +44 (0)1844www.kfp.co.uk 265003
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
EXTINGUISHING Control Systems The FireBeta XT, XT+ and ECU are the latest range of extinguishing control systems from Kidde. The range covers single area and multiarea extinguishing systems with the following: FireBeta XT Compliant to EN12094-1 provides three detection zones with single area extinguishing controls. FireBeta XT+ Is a modular system consisting of a detection module approved to EN54 parts 2 and 4 and up to 4 extinguishing modules compliant to EN12094-1. FireBeta XT+ ECU Is a single area extinguishing module compliant to EN12094-1 which can be connected to an already installed conventional or addressable fire alarm control panel providing the controls for an extinguishing system. Along with the range of FireBeta XT status indicators and the FireBeta XT Ancillary board they provide a wide selection of options for many different applications. All extinguishing control systems are suitable for use with the full range of Kidde engineered fire suppression systems incorporating 3M™ Novec™ 1230 Fire Protection Fluid, FM-200®, Argonite® inert gas and Carbon Dioxide.
FIREBETA XT 3+1
FireBeta XT 3+1 is a single area extinguishing control panel. Three detection zones and one extinguishant release area can be configured to activate from any single zone, any two zones from three or activation of all three zones. An LED display is provided to enable easy configuration, the display also provides visual indication of the time remaining until extinguishant release. The FireBeta XT provides monitored circuits for low pressure switch, release pressure switch, manual release, hold, and mode select features. Relay outputs are provided for transmitting alarms and fault, additional status relays can be provided using the ancillary output PCB. Mode select keyswitch and manual release controls are provided on the fascia panel. Up to seven ancillary output boards and seven status indicator units can be connected to the FireBeta using RS485 communications. The FireBeta XT can be easily configured for use with intrinsically safe detection and alarm devices. Technical specification Mains supply Power supply rating Battery capacity Sounder outputs Relay outputs Remote inputs Extinguishing output Dimensions
230V ac, 50Hz +10% - 15% (100 Watt maximum) 3 Amp total including battery charge 28v 2 x 12v 7ah SLA batteries 21 to 28V dc, 500mA electronic fuse – Detection sounders S1 & S2, 2nd stage sounder. 5 to 30V dc, 1 Amp maximum – Common fault, local fire, fire, 1st stage alarm, 2nd stage alarm and extract outputs. switched 0v inputs – Silence, Reset, Alarm and Fault 1 Amp maximum load for 5 minutes, voltage reversing dc 385W x 310H x 90D
23911-K069 FireBeta XT 3+1
PAGE 29/120
www.kfp.co.uk
HOME
CONTENTS
ZOOM
PRINT
EXIT
29
INTELLIGENT ADDRESSABLE FIRE ALARM PANELS
FIREBETA XT+
Technical specification Mains supply Power supply rating FireBeta XT+ is a range of multi area extinguishing control panels. The FireBeta XT+ consists of a detection module with 4 or 8 detection zones and up to 4 individual extinguishing release modules. The detection module provides all the controls and indications required for fire detection, including outputs for common fire, fault, and common sounder outputs. The detection module communicates with the extinguishing release modules using RS485 communications allowing the detection zones to be configured to activate individual release modules. Each extinguishing module is provided with an LCD giving clear information relating to status and enables easy configuration.
Battery capacity Sounder outputs Relay outputs Remote inputs Extinguishing output Dimensions
230V ac, 50Hz +10% - 15% (100 Watt maximum) 2 area units - 3 Amp total including battery charge 28v 3 & 4 area units – 4 Amp total including battery charge 28v 2 x 12v 12ah SLA batteries 21 to 28V dc, 500mA electronic fuse – Detection module sounders S1 & S2, Extinguishing module sounders 1st stage & 2nd stage alarm. 5 to 30VDC, 1 Amp maximum – Common fault, local fire, fire, 1st stage alarm, 2nd stage alarm, Released, Aborted and extract outputs. switched 0v inputs – Silence, Reset, Alarm and Fault 2 x outputs - 1 Amp load for 5 minutes or 3 Amps for 20 milliseconds 1 & 2 area units 385W x 520H x 110D 3 & 4 area units 385W x 700H x 110D
The extinguishing modules each provide monitored circuits for low pressure switch, release pressure switch, manual release, hold, and mode select features. Relay outputs are provided for transmitting alarms and fault, additional status relays can be provided using the ancillary output PCB. Two actuator outputs are provided on each extinguishant module which can be configured for common mode or main and reserve operation. A mode select keyswitch and manual release controls are provided on each release module. Up to seven ancillary output boards and seven status indicator units can be connected to the FireBeta using RS485 communications. The FireBeta XT+ can be easily configured for use with intrinsically safe detection and alarm devices.
23911-K087 FireBeta XT+ (4+1) - 4 detection zones, 1 extinguishing area 23911-K085 FireBeta XT+ (4+2) - 4 detection zones, 2 extinguishing areas 23911-K088 FireBeta XT+ (8+2) - 8 detection zones, 2 extinguishing areas 23911-K089 FireBeta XT+ (8+3) - 8 detection zones, 3 extinguishing areas 23911-K090 FireBeta XT+ (8+4) - 8 detection zones, 4 extinguishing areas
3030/120 PAGE
Tel: +44 (0)1844www.kfp.co.uk 265003
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
FIREBETA Status Indicators
FIREBETA XT ECU
FireBeta XT ECU is a single area extinguishant release module which can be connected to a conventional or addressable control panel to provide an extinguishing control system. The ECU is provided with two fully monitored inputs which can monitor outputs from a control panel used to trigger the extinguishing release module. ECU is provided with an integral 4 Amp PSU and space for 2 x 12v 7Ah SLA batteries. Relay outputs provided for common fire, fault, 1st and 2nd stage alarm. Sounder outputs provided for common, 1st and 2nd stage alarms. Dual extinguishing outputs are provided for main and reserve operation.
Technical specification Mains supply Power supply rating Battery capacity Sounder outputs Relay outputs Remote inputs Extinguishing output Dimensions
230V ac, 50Hz +10% - 15% (100 Watt maximum) 4 Amp total including battery charge 28v 2 x 12v 7ah SLA batteries 21 to 28V dc, 500mA electronic fuse - 1st stage & 2nd stage alarm. 5 to 30VDC, 1 Amp maximum – Fault, 1st stage alarm, 2nd stage alarm, Released, Aborted and Extract outputs. switched 0v inputs – Silence, Reset, Alarm and Fault 2 x outputs - 1 Amp load for 5 minutes or 3 Amps for 20 milliseconds 385W x 310H x 90D
To complement the FireBeta XT, XT+ and ECU control units, a range of System Status Indicators are available. Up to seven Status Indicators can be connected to each extinguishing area, through a serial bus connection. Status Indicators are fully supervised and fault conditions will be indicated on the associated control panel should any unit become disconnected. The status indicators are available with the following options: • • • • •
Indicator only Indicators and Auto/Manual keyswitch Indicators, Auto/Manual keyswitch and Manual Release pushbutton Flush Mounting options Weatherproof options
23911-K086 FireBeta XT ECU
PAGE 31/120
www.kfp.co.uk
HOME
CONTENTS
ZOOM
PRINT
EXIT
31
INTELLIGENT ADDRESSABLE FIRE ALARM PANELS
STATUS INDICATOR INDICATION ONLY
STATUS INDICATOR INDICATORS AND MODE KEYSWITCH
The indication only status indicator provides 6 LED’s for remote indication of the following functions:
As well as the 6 status LED’s and the 7 segment LED display this unit is provided with a Mode keyswitch which allows the user to select between Auto/Manual or Manually only extinguishing modes. In auto/manual mode extinguishing release can be activated by the automatic smoke detection or the manual operation of a release unit. Manual only mode will allow extinguishing release by manual operation of a release unit only.
• • • • • •
Auto/Manual mode Manual mode Hold activated Disabled Gas release imminent Gas released
The unit is available as either surface or flush mounting.
A seven segment LED display is also provided to show the time remaining until gas release. The unit is available as either surface or flush mounting.
23911-K073 Status Indicator - 6 LEDs & mode select key switch, surface mount 186W x 132H x 50D 23911-K074 Status Indicator - 6 LEDs & mode select key switch, flush mount 210W x 156H x 50D
STATUS INDICATOR INDICATORS, MODE KEYSWITCH AND MANUAL RELEASE As well as the indicators and the mode keyswitch this unit is provided with a Manual Release pushbutton which allows the user to manually activate the release of the extinguishing gas remotely. The manual pushbutton is two stage operation, a pull down plastic flap reveals the pushbutton. The unit is available as either surface or flush mounting.
23911-K071 Status Indicator - 6 LEDs, surface mount 186W x 132H x 50D 23911-K072 Status Indicator - 6 LEDs, flush mount 210W x 156H x 50D
3232/120 PAGE
Tel: +44 (0)1844www.kfp.co.uk 265003
23911-K075 Status Indicator - 6 LEDs, mode select key switch and manual release, surface mount 186W x 132H x 50D 23911-K076 Status Indicator - 6 LEDs, mode select key switch and manual release, flush mount 210W x 156H x 50D
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
STATUS INDICATOR 10 LEDs, MODE KEYSWITCH AND MANUAL RELEASE
FIREBETA XT ANCILLARY BOARD
This status indicator is only compatible with the FireBeta XT (3+1) extinguishing control panel. 4 additional LED’s are provided on the status indicator for indicating the alarm status of the three detection zones as well as a common fault indication.
Compatible with the FireBeta XT, XT+ and ECU control units the Ancillary Board fulfils the requirements to extend signals from the extinguishing system for additional plant control or other signaling applications, such as BMS system interface or house fire alarm systems.
23911-K077 Status Indicator - 10 LEDs, mode select key switch and manual release, surface mount 186W x 132H x 50D 23911-K078 Status Indicator - 10 LEDs, mode select key switch and manual release, flush mount 210W x 156H x 50D
WEATHERPROOF STATUS INDICATOR The range of status indicators are also available in an IP65 weatherproof enclosure. 23911-K079 Weatherproof Status Indicator - 6 LEDs, surface mount IP65 - 256W x 169H x 76D
Up to seven Ancillary Boards can be connected to the same serial bus as the status indicators providing distributed control and signalling at multiple locations if required. Each output of the Ancillary Board has an LED which indicates operation. The FireBeta XT Ancillary Board contains volt-free changeover contacts for signalling the following: • • • • • • • • • •
Zone 1 fire Zone 2 fire Zone 3 fire Manual only mode Disablement active Released Activated Manual release operated Extract fan operated Hold activated
Dimensions: 155W x 136H
23911-K080 Weatherproof Status Indicator - 6 LEDs & mode select key switch, surface mount IP65 - 256W x 169H x 76D 23911-K081 Weatherproof Status Indicator - 6 LEDs & mode select key switch and manual release, surface mount IP65 - 256W x 169H x 76D 23911-K082 Weatherproof Status Indicator - 10 LEDs & mode select key switch and manual release, surface mount IP65 - 256W x 169H x 76D
PAGE 33/120
www.kfp.co.uk
23911-K070 FiteBeta XT Ancillary board
HOME
CONTENTS
ZOOM
PRINT
EXIT
33
INTELLIGENT ADDRESSABLE FIRE ALARM PANELS
HOLD SWITCH
ABORT SWITCH
The Hold Switch is a non-latching push button that can be connected to the monitored Hold circuit on the extinguishing control panel. When the extinguishing system is in alarm and gas release is imminent the Hold switch can be pressed to stop the extinguishing release sequence. The release sequence will be delayed as long as the Hold switch remains pressed allowing all personnel to evacuate before extinguishing gas is released into the area. When the Hold switch is released the extinguishing sequence re-starts and the extinguishing gas will be released into the risk area.
The Abort switch is a latching push button that can be connected to the monitored hold circuit of the FireBeta XT, XT+ or ECU. When operated the switch will remain in the on position until physically released. The Abort button allows the operator to prevent the release of extinguishing gas in the event of accidental activation of the system. The system can be reset before the Abort button is physically released.
• • • •
Dimensions: 108W x 108H x 85D 35mm red, mushroom type push button, configured as a non latching switch with two sets of single pole single throw contacts rated 5A @ 30V dc The screw type terminals can accept conductors up to 4mm 2 The contacts house a 100 ohm alarm resistor which is introduced into the circuit when the switch is operated
53836-K179 Hold Switch
3434/120 PAGE
• • • •
Dimensions: 108W x 108H x 85D 35mm red, mushroom type push button, configured as a latching switch with two sets of single pole single throw contacts rated 5A @ 30 V dc The screw type terminals can accept conductors up to 4mm 2 The contacts house a 100 ohm alarm resistor which is introduced into the circuit when the switch is operated
53836-K180 Abort Switch
Tel: +44 (0)1844www.kfp.co.uk 265003
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
PAGE 35/120
www.kfp.co.uk
HOME
CONTENTS
ZOOM
PRINT
EXIT
35
DETECTION AND ALARM
3636/120 PAGE
Tel: +44 (0)1844www.kfp.co.uk 265003
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
Detection and Alarm devices can be separated into two main categories “Intelligent” and “Conventional”. Intelligent devices have unique addresses and are connected to control panels in a loop configuration. Intelligent detectors give advanced warning of a developing hazard and can pinpoint the individual device raising alarm. Intelligent audio/visual devices can be independently programmed and controlled allowing for extensive cause and effects such as phased evacuation.
The Kidde Discovery and XP95 ranges offer a wide selection of intelligent detectors, manual call points, interface modules and audio/visual devices compatible with the Vega Analogue Addressable control panel. Conventional devices are connected to a control panel as a zone in the case of detection devices, or as a circuit in the case of audio/ visual devices. Conventional systems do not have the capability of identifying individual
PAGE 37/120
www.kfp.co.uk
HOME
CONTENTS
devices but only identify the zone or a circuit as a whole therefore in an alarm condition the search area for a conventional detection zone can be large (up to 2000m2). The Kidde Orbis and Series 65 range of detectors are compatible with the Sirius II conventional control panel and also the FireBeta XT and XT+ range of extinguishing control panels.
ZOOM
PRINT
EXIT
37
DETECTION AND ALARM
Detector types
Ionisation Smoke Detectors detect smoke by using a small ionising radiation source. Ionisation detectors respond well to fast-burning (flaming) fires and are widely used for property protection.
Heat Detectors are available in two types: fixed temperature and rate-of-rise. Rate-of–rise detectors monitor for rapid increases in the temperature within the area, but also have a fixed temperature limit which will trigger an alarm if the rate of temperature rise has been too slow. Fixed temperature heat detectors are designed to alarm at a set temperature value. Heat detectors are more suitable in environments where conditions would lead to false alarms with smoke detectors, e.g. kitchens, boiler rooms etc. However a heat detector will respond only when a fire is well established and generating high heat output.
Optical Smoke Detectors detect smoke by using an LED light source and photodiode. Optical detectors respond particularly well to slow-burning, smouldering fires and are widely used for life protection
3838/120 PAGE
Tel: +44 (0)1844www.kfp.co.uk 265003
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
Multisensor Detectors are a combined optical and heat detector allowing flexibility in the detection of fires. Using the combined detection method a fire condition can be confirmed if both heat and smoke sensors operate. Multisensor detectors are general purpose detectors which respond well to a wide range of fires.
Beam Detectors consist of three main parts: The transmitter, which projects a beam of infra-red light; the receiver, which registers the light and produces an electrical signal; and the interface, which processes the signal and generates an alarm or fault. When a fire develops, smoke particles obstruct the infra red beam and once a preset threshold has been exceeded, the detector will go into alarm. Beam detectors are designed to protect large open spaces such as atria, warehouses, museums, and churches.
Flame Detectors are designed to detect either ultraviolet (UV) or infra red (IR) radiation emitted by a fire. A number of different types of flame detectors from UV, IR, UV/IR, dual, triple and multispectrum detectors are available for various different applications . Flame detectors are designed to protect areas where flaming fires may be expected such as aircraft hangars, power plants, oil refineries and paper manufacturing.
Carbon Monoxide (CO) Detectors detect poisonous carbon monoxide gas produced by combustion. The detector contains an electromechanical cell which reacts to the presence of CO in the air. The CO detector will not detect smoke or any other products of combustion. Carbon Monoxide detectors are particularly effective at detecting deep-seated smouldering fires.
PAGE 39/120
www.kfp.co.uk
HOME
CONTENTS
ZOOM
PRINT
EXIT
39
DETECTION AND ALARM – INTELLIGENT FIRE DETECTION
Intelligent Fire Detection There are two types of intelligent detection system those with ‘distributed intelligence’ and those with ‘centralised intelligence’. In systems with distributed intelligence the detectors incorporate processors, which can determine whether the alarm levels of smoke or heat exist and can initiate action accordingly. Detectors in systems with centralised intelligence monitor the air around them for smoke or heat and transmit the data to the control panel on interrogation. The processor in the panel compares the values with stored values and determines whether a pre-alarm or alarm should be signalled. The advantages of distributed intelligence are local adaptation to environment and reduction of traffic on the supply and data wires. The advantage of centralised intelligence is the ability to upgrade a system very quickly and easily by upgrading the control panel.
4040/120 PAGE
Tel: +44 (0)1844www.kfp.co.uk 265003
Discovery Intelligent Fire Detection Discovery is a range of high-specification, intelligent fire detectors developed to meet the requirements of sophisticated systems while providing engineers with an additional dimension in fire protection capability. Discovery has a ‘distributed intelligence system’ where decisions are made in the detector head as well as at the control panel. Drift compensation is also incorporated into the detector, allowing it to adapt to dirty or dusty environments reducing false alarms. Key features of Discovery include: •
Rejection of transient signals
•
Flashing LED option
•
Five response modes for ease of optimisation to changing environments
•
Drift compensation to ensure constant sensitivity
•
Four bytes of non-volatile memory for user data
•
Alarm flag for fast alarm reporting
•
Conventional alarm facility during control panel processor fault
•
360° visibility in alarm
•
Compatible with XP95 systems
•
Insect resistant
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
DISCOVERY IONISATION SMOKE DETECTOR The Discovery Ionisation Smoke Detector uses a low activity radioactive foil to irradiate the air in the smoke chamber causing a current flow. If smoke enters the chamber, the current flow is reduced leading to an alarm.
DISCOVERY HEAT DETECTOR • • •
Responds well to fast-burning, flaming fires Designed to operate in a variety of environments Remote test feature
• • •
Ideal in environments that are dirty or smokey under normal conditions Well suited for warehouses, loading bays and car parks Unaffected by wind or atmospheric pressure Remote test feature
23900-K144 Discovery Heat Detector
DISCOVERY OPTICAL SMOKE DETECTOR
DISCOVERY MULTISENSOR DETECTOR
• • • •
Responds well to slow-burning, smouldering fires Well suited for bedrooms and escape routes Unaffected by wind or atmospheric pressure Remote test feature
23900-K142 Discovery Optical Smoke Detector
PAGE 41/120
•
the detector.
23900-K141 Discovery Ionisation Smoke Detector
The Discovery Optical Smoke Detector works using the light scatter principle and is ideal for applications where slow-burning or smouldering fires are likely.
The Discovery Heat Detector, distinguishable by the low airflow resistant case, uses a single thermistor to sense the air temperature around
The Discovery Multisensor Detector comprises optical smoke and thermistor temperature sensors whose outputs are combined to give the final analogue value. As a result, the multisensor is useful over a wide range of applications and is highly immune to false alarms.
• • • • • • •
Ideal for a wide range of applications Highly immune to false alarms Well suited for environments such as hotel bedrooms Unaffected by wind or atmospheric pressure Well suited for sensitive environments Heat only, optical only modes Remote test feature
23900-K143 Discovery Multisensor Detector
www.kfp.co.uk
HOME
CONTENTS
ZOOM
PRINT
EXIT
41
DETECTION AND ALARM – INTELLIGENT FIRE DETECTION
DISCOVERY CARBON MONOXIDE DETECTOR
DISCOVERY/XP95 DEEP MOUNTING BASE
The Discovery Carbon Monoxide (CO) Detector is good at detecting deep-seated fires. Please note that CO detectors do not detect smoke particles or heat and are not universal replacements for smoke detectors.
• • • • •
Enhanced detection capability Early response to hot fires Ideal for smouldering fires Less susceptible to false alarms caused by steam than smoke alarms Five response modes
•
Enables surface wiring
•
XPERT Addressing
•
One way fit
•
Locking feature to prevent unauthorised removal
23900-K204 Discovery/XP95 Deep mounting base
23900-K147 Discovery Carbon Monoxide Detector
DISCOVERY/XP95 MOUNTING BASE C/W XPERT CARD
DISCOVERY/XP95 ISOLATING BASE
All detectors in the Discovery range fit the Intelligent Mounting Base. The Mounting Base is a low insertion force base with stainless steel contacts for the detector terminals. XPERT cards are supplied with all bases.
• • •
XPERT addressing One way fit Locking feature to prevent unauthorised removal
23900-H05 Discovery/XP95 mounting base c/w Xpert card
4242/120 PAGE
The Intelligent Deep Base is a mounting base for Discovery products which has an increased depth allowing for cables to be inserted into the side of the product.
Tel: +44 (0)1844www.kfp.co.uk 265003
The new Isolating Base senses and detects short circuit faults on Discovery/XP95 loops and spurs.
•
Up to 20 devices may be installed between isolating bases
23900-K203 Discovery/XP95 Isolating base
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
MINIDISC REMOTE INDICATOR
DISCOVERY MANUAL CALL POINT The Discovery Manual Call Point is compliant with EN54-11. The Call Point can be addressed at the commissioning stage by means of a seven-segment DIL switch. When operated, the manual call point interrupts the polling cycle for a fast response.
•
Flashing LED option
•
Plug and play terminal connections for fast wiring
•
Allows wiring continuity testing before fitting
•
Isolated version available
•
Reports an alarm in under 0.2 seconds
•
Resettable element
The MiniDisc Remote Indicator is a light-weight, compact indicator for use in fire Protection systems. The remote indicator can be wired to detectors which are not visible, i.e. in ceiling/ floor voids. This allows identification of the operated device.
• • •
Can be used across the entire Apollo range Small and discrete Anti-tamper screw to protect against unauthorized removal.
•
Simplifies and speeds up installation and commissioning Uses patented, proven technology Address remains the same, no matter how often detectors are replaced Flexibility to create any address
23900-K095 MiniDisc Remote Indicator
23900-K195 Discovery Manual Call Point (surface) 23900-K196 Discovery Manual Call Point with Isolator (surface)
BLANK XPERT CARD
DISCOVERY WEATHERPROOF MANUAL CALL POINT The Waterproof Manual Call Point has been designed for use outdoors and in places where moisture can occur. It is compliant with EN54-11 and can be used with the Discovery range.
•
Plug and play terminal connections for fast wiring
•
Allows wiring continuity testing before fitting
•
Resettable element
•
IP 67
23900-K197 Discovery Weatherproof Manual Call Point
PAGE 43/120
www.kfp.co.uk
A universal address card supplied with all Discovery/XP95 bases. Using a coding guide pips are removed to set the address of the inserted detector.
• • •
23900-H09 Blank XPERT card
HOME
CONTENTS
ZOOM
PRINT
EXIT
43
DETECTION AND ALARM – INTELLIGENT FIRE DETECTION
XP95 Intelligent Fire Detection
XP95 IONISATION SMOKE DETECTOR
The XP95 range of intelligent fire detectors is advanced in design, improved in performance and has unique features that benefit the installer and end user. The range features smoke detectors (ionisation and optical), standard and high temperature heat detectors and a multisensor. Beam detectors, flame detectors, manual call points, audio visual signalling devices, interface units and isolators complete the range. XP95 is a ‘central intelligence’ system where all the decisions are made by the control panel.
The XP95 Ionisation Smoke Detector uses a low activity radioactive foil to irradiate the air in the smoke chamber causing a current flow. If smoke enters the chamber, the current flow is reduced leading to an alarm.
•
Responds well to fast-burning, flaming fires
•
Designed to operate in a variety of environments
•
Minimal effects from temperature, humidity, atmospheric pressure
•
Well protected against electromagnetic interference over a wide frequency range
•
Responds well to slow-burning, smouldering fires
• •
Well suited for bedrooms and escape routes Unaffected by wind or atmospheric pressure
23900-K040 XP95 Ionisation Smoke Detector
Key features of XP95 include: •
Alarm Flag for fast alarm reporting
•
Alarm Address for fast location of alarm
•
XPERT card addressing
•
Electronics-free base
•
Easy installation
•
Elegant design
•
Insect resistant
XP95 OPTICAL SMOKE DETECTOR
The XP95 Optical Smoke Detector works using the light scatter principle and is ideal for applications where slow-burning or smouldering fires are likely. 23900-K041 XP95 Optical Smoke Detector
4444/120 PAGE
Tel: +44 (0)1844www.kfp.co.uk 265003
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
XP95 ISOLATOR
XP95 HEAT DETECTOR
The XP95 Heat Detector monitors temperature by using a single thermistor network which provides a count output proportional to the external air temperature. The XP95 range features two Heat Detectors, standard and high temperature. The standard heat detector is classified as an A2S device and will report an alarm at 55°C. The high temperature detector, classified as a CS device, will report an alarm at 90°C.
•
Ideal in environments that are dirty or smoky under normal conditions
•
Well suited for warehouses, loading bays and car parks
•
Unaffected by wind or atmospheric pressure
The XP95 Isolator is placed at intervals on the loop and ensures that, in the case of a short circuit, only the section between the isolators will be affected. When the short circuit is removed, the isolators automatically restore power and data to the isolated section.
•
Detects wiring short circuits using patented technology
•
Minimises disruption from short circuits
• •
Automatic de-isolation on short circuit removal Up to 20 devices may be installed between isolators
23900-K161 XP95 Isolator
23900-K042 XP95 Heat Detector Standard 23900-K050 XP95 Heat Detector High Temperature
XP95 ISOLATOR BASE
XP95 MULTISENSOR DETECTOR The XP95 Multisensor Detector contains an optical smoke sensor and a thermistor temperature sensor whose outputs are combined to give the final analogue value.
•
Sensitive to a wide range of fires
•
Well suited for environments such as hotel bedrooms
•
Unaffected by wind or atmospheric pressure
23900-H09 XP95 Isolator base
23900-K130 XP95 Multisensor Detector
PAGE 45/120
The XP95 Isolating base is unique and designed only to accept the XP95 Isolator.
www.kfp.co.uk
HOME
CONTENTS
ZOOM
PRINT
EXIT
45
DETECTION AND ALARM – INTELLIGENT FIRE DETECTION
DISCOVERY/XP95 ISOLATING BASE
DISCOVERY/XP95 MOUNTING BASE C/W XPERT CARD All detectors in the XP95 range fit the Intelligent Mounting Base. The Mounting Base is a low insertion force base with stainless steel contacts for the detector terminals. XPERT cards are supplied with all bases.
• • •
XPERT addressing One way fit Locking feature to prevent unauthorised removal
23900-H05 Discovery/XP95 Mounting base
•
Up to 20 devices may be installed between isolating bases
•
Gives a set of voltage free contacts controlled by the remote output of a detector
•
Draws negligible current
•
Capable of switching up to 30V at 1A
23900-K203 Discovery/XP95 Isolating base
DISCOVERY/XP95 DEEP MOUNTING BASE
INTELLIGENT LOW POWER RELAY BASE
The Intelligent Deep Base is a mounting base for Discovery products which has an increased depth allowing for cables to be inserted into the side of the product.
•
Enables surface wiring
23900-K204 Discovery/XP95 Deep mounting base
4646/120 PAGE
The Isolating Base senses and detects short circuit faults on Discovery/XP95 loops and spurs.
Tel: +44 (0)1844www.kfp.co.uk 265003
The Low Power Relay Base incorporates a low power relay to control field equipment such as automatic door closers.
23900-K196 Intelligent Low Power Relay Base
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
SERIES 90 TO XP95 BASE ADAPTOR The XP95 Base Adaptor is designed to allow XP95 detectors to be fitted to an existing Series 90 base. The adaptor eliminates the need to re-wire an existing Apollo intelligent system.
XP95 MANUAL CALL POINT •
Allows an existing range to be updated with ease
•
Eliminates the need for re-wiring
The XP95 Manual Call Point is compliant with EN54-11. The address of each call point is set at the commissioning stage by means of a seven-segment DIL switch. The device features plug and play terminal connections and a resettable element.
•
Plug and play terminal connections for fast wiring
• • •
Allows wiring continuity testing before fitting Reports an alarm in under 0.2 seconds Resettable element
23900-K192 Manual Call Point with Isolator (surface) 23900-K226 Series 90 to XP95 Base Adaptor
DUAL IR FLAME DETECTOR BLANK XPERT CARD
A universal address card supplied with all Discovery/XP95 bases. Using a coding guide pips are removed to set the address of the inserted detector.
• • • •
Simplifies and speeds up installation and commissioning Uses patented, proven technology Address remains the same, no matter how often detectors are replaced Flexibility to create any address
23900-H09 Blank XPERT card
The intelligent Dual Infra-Red (IR2) Flame Detector is designed for use in areas where flaming fires may be expected. The detector has two sensors which respond to different IR wavelengths to discriminate between flames and spurious sources of radiation. Applications include aircraft hangars, coal handling, paper manufacturing plants and woodworking environments.
• • • • • • •
Sensitive to flickering IR radiation Detects through films of oil, dust, water and ice Responds to flickering flames, including those invisible to the naked eye Compatible with XP95 and Discovery protocols Remote optical self test function 90o field of view Up to 40m coverage
23900-K092 XP95 Dual IR Fire detector 23900-K091 Flame detector mounting bracket 23900-K090 Flame detector weathershield
PAGE 47/120
www.kfp.co.uk
HOME
CONTENTS
ZOOM
PRINT
EXIT
47
DETECTION AND ALARM – INTELLIGENT AUDIO VISUAL SIGNALLING
OPTICAL BEAM DETECTOR The Optical Beam Detector is made up of three main parts: the transmitter, which projects a beam of infra-red light, the receiver, which registers the light and produces an electrical signal, and the interface, which processes the signal and generates an alarm or fault.
• • • • • •
Loop powered Compatible with Discovery and XP95 protocols Four selectable sensitivity levels Drift compensation Remote interface Simple wiring and alignment
23900-K087 XP95 Optical beam detector 23900-K088 Beam detector reflector
MINIDISC REMOTE INDICATOR The MiniDisc Remote Indicator is a light-weight, compact indicator for use in fire Protection systems. The remote indicator can be wired to detectors which are not visible, i.e. in ceiling/ floor voids. This allows identification of the operated device.
• • •
Can be used across the entire Apollo range Small and discrete Anti-tamper screw to protect against unauthorized removal.
23900-K095 MiniDisc Remote Indicator
4848/120 PAGE
Tel: +44 (0)1844www.kfp.co.uk 265003
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
Intelligent Audio/Visual Signalling
INTELLIGENT OPEN-AREA SOUNDER (SONOS) The Intelligent Open-Area Sounder has been designed for use in open areas and can be connected to any Discovery or XP95 system. Sound output of 100dB(A) at 90° +/- 3dB(A).
Kidde offers a wide range of Intelligent audio/visual signalling devices for use with Analogue addressable control panels to meet the requirements of the DDA.
•
Self-test fault monitoring
• • • • •
Choice of tones Synchronisation of alarm Weatherproof IP65 Comes with Isolating Base as standard Loop powered
23900-K222 Intelligent Open-Area Sounder, Red (Sonos)
The intelligent audio/visual signalling devices are compatible with both XP95 and Discovery protocols.
100dB (A) WEATHERPROOF LOOP POWERED SOUNDER
The 100dB (A) Weatherproof Sounder is designed for use in open areas and can be connected to any Discovery or XP95 system. The sounder comprises a backbox and sounder unit supplied together.
23900-K221
PAGE 49/120
www.kfp.co.uk
HOME
•
IP 66 (immune to the affects of wind and precipitation)
•
Output is 100dB (A) at 90°
•
Current consumption of 5.0mA
•
Can be synchronised
•
Loop powered
•
Wall mounted
100dB (A) Weatherproof Sounder Red
CONTENTS
ZOOM
PRINT
EXIT
49
DETECTION AND ALARM – INTELLIGENT AUDIO VISUAL SIGNALLING
LOOP-POWERED BEACON BASE
INTEGRATED LOOP POWERED SOUNDER BASE The Integrated Base Sounder comprises a loop powered sounder within an intelligent mounting base and is for use with Discovery or XP95 ranges. It is designed for use in enclosed areas.
•
Two tone ranges
•
Synchronisation of ‘alert’ and ‘evacuate’ tones
•
Unique acoustic self-test
•
Integrated base
The Beacon Base is a loop-powered beacon combined with a standard Intelligent Mounting Base. It is used to signal a fire alarm in enclosed areas. The beacon base can be used with either a detector fitted or with a cap as a stand-alone alarm device.
•
Beacon flash rate of once per second
•
Synchronisation of beacon flash
•
Unique beacon self-test
•
Loop powered
•
Isolator option
23900-K218 Loop-Powered Beacon base with Standard Flash
23900-K220 Integrated Loop powered sounder base
DISCOVERY OPEN-AREA SOUNDER BEACON
INTELLIGENT OPEN-AREA BEACON SONOS The Intelligent Open-Area Beacon has been developed for use in situations where there is a risk sounders may not be heard.
•
Self-test fault monitoring
•
Weatherproof IP65
•
Synchronisation of alarm
•
Comes with Isolating Base as standard
•
Loop powered
The Discovery Open-Area Sounder Beacon makes full use of the Discovery protocol and has been designed for use indoors and outdoors. When the fire system is being commissioned a Magnetic Wand can be used to adjust and test each sounder locally.
•
Loop powered
•
Tones can be used for other purposes in addition to warning of fire, ideal for schools
•
Soft start option, ideal for hospitals and nursing homes
Magnetic wand is an optional item, ordered seperately. 23900-K219
5050/120 PAGE
Intelligent Open-Area Beacon, Red Lense Sonos
Tel: +44 (0)1844www.kfp.co.uk 265003
23900-K217 Discovery Open-Area Sounder beacon Red Lens
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
XP95 SOUNDER BEACON BASE The sounder beacon base is a loop-powered sounder and beacon combined with a standard intelligent mounting base. It is used to signal a fire alarm in enclosed areas. The sounder beacon base can be used either with a detector fitted or with a cap for operation as a standalone alarm device.
• • • • • •
Two volume ranges 55-75dB(A) and 75-91dB(A) Beacon flash rate of once per second Synchronisation of ‘alert’ and ‘evacuate’ tones Synchronisation of beacon flash Unique acoustic and beacon self test Enables DDA compliance
23900-K216 XP95 Sounder Beacon Base
PAGE 51/120
www.kfp.co.uk
HOME
CONTENTS
ZOOM
PRINT
EXIT
51
DETECTION AND ALARM – INTERFACE MODULES
Interface Modules Kidde supply a range of addressable interface modules which are compatible with the Kidde Vega intelligent control panel. The interfaces provide various types of input, output and combined input and output units, which allow other equipment to be monitored and controlled by the Intelligent Fire System through the detection loop. Interface module range includes: • • •
Standard interfaces with isolators Mini interfaces DIN-Rail interface
Standard Interfaces with Isolators Standard Interfaces with Isolators are fitted with bi-directional short-circuit isolators so that they are unaffected by a single short circuit on either loop input or output. However, the Input/Output Unit and Output Unit with isolator are exceptions to this. The removal of loop power to these interfaces will cause a ‘set’ relay to ‘reset’.
Key features of Interfaces: • Easy to install • Well protected • Modular design • A neat solution
5252/120 PAGE
Tel: +44 (0)1844www.kfp.co.uk 265003
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
INPUT/OUTPUT UNIT WITH ISOLATOR The Input/Output unit with isolator provides a voltage free single pole, change-over relay output, a single monitored switch input and an unmonitored non-polarised opto-coupled input. Dimensions
150W x 90H x 48D
SOUNDER CONTROL UNIT WITH ISOLATOR • • • • •
It can report fault, switch open and switch closed levels Four status LEDs Loop powered Voltage free Capable of switching up to 30V at 1A
23900-K132 Input/Output Unit with Isolator
Dimensions
150W x 90H x 48D
• • •
Requires external PSU 9–32vdc Allows sounders to be operated continuously or pulsed, 1 second on 1 second off May be synchronized when in pulsed operation Three status LEDs Output rated 1A @ 30vdc
SWITCH MONITOR WITH ISOLATOR
• •
Two status LEDs Capable of switching up to 30V at 1A
150W x 90H x 48D
The Switch Monitor with Isolator is designed to monitor the state of one or more single pole, volt free contacts connected on a single pair of cables reporting the status to Apollo compatible analogue control equipment. Dimensions
23900-K133 Output Unit with Isolator
PAGE 53/120
Dimensions
• •
23900-K137 Sounder Control Unit with Isolator
OUTPUT UNIT WITH ISOLATOR
The Output Unit with Isolator provides two voltage free single pole, change-over relay outputs. It is a simplified version of the Input/ Output unit without circuitry for monitoring inputs.
The XP95 Sounder Control Unit with isolator is used to control the operation of a Zone of conventional sounders and report their status to the control panel.
•
Four input states - ’normal’, ’fault’, ’pre-alarm’ and ’alarm’
• •
Three status LEDs Loop powered
150W x 90H x 48D
23900-K134 Switch Monitor with Isolator
www.kfp.co.uk
HOME
CONTENTS
ZOOM
PRINT
EXIT
53
DETECTION AND ALARM – INTERFACE MODULES
Mini Interfaces
SWITCH MONITOR PLUS WITH ISOLATOR The Switch Monitor Plus with Isolator is designed to monitor the state of one or more single pole, volt free contacts connected on a single pair of cables reporting the status to Apollo compatible analogue control equipment. Dimensions
• • • • •
150W x 90H x 48D
D
Selectable alarm delay for monitoring flow switches Output for resetting a remote detector Four input states - ’normal’, ’fault’, ’pre-alarm’ and ’alarm’ Three status LEDs Loop powered
Mini Interfaces use very compact enclosures for installation into other equipment.
23900-K135 Switch Monitor Plus with Isolator
MINI SWITCH MONITOR ZONE MONITOR WITH ISOLATOR
The Zone Monitor with Isolator powers and controls the operation of a zone of up to 20 Apollo Series 65 or Orbis fire detectors from a Discovery or XP95 Loop. Dimensions
• •
Two status LEDs Loop powered
150W x 90H x 48D
The Mini Switch Monitor is designed to monitor the state of one or more single pole, volt free contacts connected on a single pair of cables reporting the status to Apollo compatible control analogue equipment. Designed to be fitted on a standard 35mm DIN-Rail or mounted within an enclosure, its compact size allows it to be installed where space is limited. Dimensions
23900-K136 Zone Monitor with Isolator
5454/120 PAGE
Tel: +44 (0)1844www.kfp.co.uk 265003
23900-K205
• • • • •
Loop powered Isolated as standard Interrupt/non interrupt in one unit ‘Pre-alarm’ status available Three, coloured LEDs, giving clear status indication
39W x 39H x 20D Mini Switch Monitor
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
DIN-Rail Interfaces
DIN-RAIL INPUT/OUTPUT UNIT
DIN-Rail Interfaces feature enclosures that clip to standard 35mm DIN-Rails or are screwed to the base of a larger enclosure. They enable fire system designers to determine the functions required and create multi-purpose interfaces for individual sites.
The DIN-Rail Input/Output Unit provides a voltage free single pole, change-over relay output, a single monitored switch input and an unmonitored non-polarised opto-coupled input. Dimensions
•
It can report fault, switch open and switch closed levels
•
Three status LEDs
•
Loop powered
•
Capable of switching up to 30V at 1A
•
Single status LED
• •
Loop powered Capable of switching up to 30V at 1A
110W x 107H x 20D
23900-K069 DIN-Rail Input/Output Unit
DIN-RAIL OUTPUT UNIT
The DIN-Rail Output Unit provides a voltagefree single pole, change-over relay output. It is a simplified version of the Input/Output unit without circuitry for monitoring inputs. Dimensions
110W x 107H x 20D
23900-K070 DIN-Rail output unit
PAGE 55/120
www.kfp.co.uk
HOME
CONTENTS
ZOOM
PRINT
EXIT
55
DETECTION AND ALARM – INTERFACE MODULES
DIN-RAIL SOUNDER CONTROL UNIT
DIN-RAIL ZONE MONITOR WITH ISOLATOR
The DIN-Rail Sounder Control Unit is used to control the operation of a zone of Conventional sounders and report their status to the control panel. Dimensions
110W x 107H x 20D
•
Requires external PSU 9 – 50 vdc
•
Allows sounders to be operated continuously or pulsed, 1 second on, 1 second off May be synchronized when in pulsed operation Two status LEDs
• •
Dimensions
23900-K074 DIN-Rail sounder control unit
5656/120 PAGE
Built in short cicuit isolator
• •
Two status LEDs Loop powered
110W x 107H x 20D
DIN-RAIL SWITCH MONITOR PLUS
The DIN-Rail Switch Monitor is designed to monitor the state of one or more single pole, volt free contacts connected on a single pair of cables and to report the status to Apollo compatible analogue control equipment.
23900-K071
•
23900-K073 DIN-Rail Zone Monitor with Isolator
DIN-RAIL SWITCH MONITOR
Dimensions
The Zone Monitor powers and controls the operation of a zone of up to 20 Apollo Series 65 or Orbis fire detectors from a Discovery or XP95 Loop.
•
Four input states – ‘normal’, ‘fault’, ‘pre-alarm’ and ‘alarm’
•
Two status LEDs
•
Loop powered
110W x 107H x 20D DIN-Rail switch monitor
Tel: +44 (0)1844www.kfp.co.uk 265003
The DIN-Rail Switch Monitor Plus is designed to monitor the state of one or more single pole, volt free contacts connected on a single pair of cables reporting the status to Apollo compatible analogue equipment.
•
Output for resetting a remote detector
•
Four input states – ‘normal’, ‘fault’, ‘pre-alarm’ and ‘alarm’
•
Selectable alarm delay for monitoring flow switches
•
Two status LEDs
Dimensions
•
Loop powered
110W x 107H x 20D
23900-K072 DIN-Rail Switch Monitor Plus
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
DIN-RAIL DUAL ISOLATOR The DIN-Rail Dual Isolator provides two independent Isolators which sense and isolate short circuits on Discovery or XP95 loops and spurs.
•
Polarity sensitive
•
Up to 20 detectors can be installed between isolators
•
Two status LEDs
•
Loop powered
23900-K075 DIN-Rail Dual Isolator
PAGE 57/120
www.kfp.co.uk
HOME
CONTENTS
ZOOM
PRINT
EXIT
57
DETECTION AND ALARM – CONVENTIONAL FIRE DETECTION
Conventional Fire Detection In conventional systems the detectors are wired as a circuit or zone. They signal fire conditions to the control panel by changing from a high to low impedance. The panel detects this impedance change by current monitoring and identifies the zone where the alarm has been raised. Compatible with the Kidde Sirius II and FireBeta XT and XT+ range of extinguishing control panels they are an ideal cost effective detection system for small area applications.
5858/120 PAGE
Tel: +44 (0)1844www.kfp.co.uk 265003
ORBIS Conventional Fire Detection Orbis is a range of conventional detectors which has been developed with sophisticated technology previously only found in intelligent detectors. Orbis is a range with modern styling and incorporates a mounting base wihich saves installation time. Key features of Orbis: •
Automatic drift compensation with DirtAlert® warning
•
Patented FasTest® which reduces the time taken to test detectors
•
SensAlert® uses a flashing LED to indicate that the sensor is not operating correctly
•
StartUp™ for fast commissioning
•
Attractive and compact design
•
Electrically compatible with Series 60 and Series 65
•
Wide voltage and operating temperature ranges
•
Algorithms for transient rejection
•
360° visibility of LEDs
•
Insect Resistant
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
ORBIS HEAT DETECTOR
ORBIS OPTICAL SMOKE DETECTOR The Orbis Optical Smoke Detector works using the well established light scatter principle, however, the sensing technology is radically different in design from previous optical detectors and significantly reduces false alarms.
• • • • • •
Responds well to slow-burning, smouldering fires Performs well in black and white smoke Extra confirmation of smoke before alarm signal is given Reduced incidence of false alarms Sensing chamber keeps out dust and other airborne contaminants Operates over a broad range of voltages at extremes of temperature
ORBIS MULTISENSOR DETECTOR
• • • • •
Responds well to fast-burning, flaming fires Reduced incidence of false alarms Increased reliability of detection Sensing chamber keeps out dust and other airborne contaminants Operates over a broad range of voltages at extremes of temperature
23900-K179 ORBIS Multisensor Detector
PAGE 59/120
• • • •
Can be used for applications where smoke detectors are unsuitable Ideal in environments that are dirty or smoky under normal conditions Reduced incidence of false alarms Increased reliability of detection
ORBIS HEAT DETECTOR
23900-K178 ORBIS Optical Smoke Detector
The Orbis Multisensor detector benefits from the same false alarm reduction technology as the optical detector. It is a thermally enhanced smoke detector and so will not give an alarm from heat alone.
The Orbis Heat Detector monitors temperature by using a single thermistor network which provides a voltage output proportional to the external air temperature. There are seven classes of heat detectors in the Orbis range designed to suit a wide variety of operating conditions.
23900-K180
Rate-of-Rise MAT 50 C A1R - Standard
23900-K181
Static MAT 50 C A2S - Standard
23900-K182
Rate-of-Rise MAT 65 C BR - Standard
23900-K183
Static MAT 65 C BS - Standard
23900-K184
Rate-of-Rise MAT 80 C CR - Standard
23900-K185
Static MAT 80 C CS - Standard
MAT (Maximum Application Temperature)
www.kfp.co.uk
HOME
CONTENTS
ZOOM
PRINT
EXIT
59
DETECTION AND ALARM – CONVENTIONAL FIRE DETECTION
TIMESAVER RELAY BASE
TIMESAVER BASE
The TimeSaver Base® is a completely new design that provides installers with an open working area with fixing holes shaped to allow a simple mounting procedure.
• • • • •
Grouped terminals to make wiring easy Two fixing centres LED alignment mark Cable stripping guide Detector locking mechanism
The TimeSaver Relay Base incorporates a single pole voltage free change-over contact for switching external equipment. When the detector changes to the alarm state, the relay is energised causing the contact to change state. The contact will remain in this condition until the detector is reset.
23900-K186 TimeSaver Base
• • • • • • •
Grouped terminals to make wiring easy Two fixing centres LED alignment mark Cable stripping guide Continuity link for voltage testing of zone wiring prior to commissioning Detector locking mechanism Capable of switching up to 30V at 1A
•
Enables surface wiring
23900-K188 TimeSaver Relay Base
TIMESAVER DIODE BASE TIMESAVER DEEP BASE The TimeSaver Diode Base has the same design as the standard TimeSaver Base® with the addition of a diode. It is used in systems which house active EOL monitoring for head removal.
• • • • • • •
Grouped terminals to make wiring easy Two fixing centres LED alignment mark Cable stripping guide Continuity link for voltage testing of zone wiring prior to commissioning Detector locking mechanism Other devices continue to work during unauthorised removal of detectors
23900-K225 TimeSaver Relay Base
23900-K187 TimeSaver Diode Base
6060/120 PAGE
The TimeSaver Deep Base is a mounting base for Orbis products which has an increased depth allowing for cables to be inserted into the side of the base.
Tel: +44 (0)1844www.kfp.co.uk 265003
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
SERIES 65 TO ORBIS BASE ADAPTOR
The Orbis Adaptor is designed to allow Orbis detectors to be fitted to an existing Series 60 or Series 65 base. The adaptor eliminates the need to rewire an existing Apollo conventional system.
•
Allows an existing range to be updated with ease
•
Eliminates the need for re-wiring
• • •
Can be used across the entire Apollo range Small and discrete Anti-tamper screw to protect against unauthorized removal.
23900-K224 Series 65 to Orbis Base Adaptor
MINIDISC REMOTE INDICATOR The MiniDisk Remote Indicator is a light-weight, compact indicator for use in fire Protection systems. The remote indicator can be wired to detectors which are not visible, i.e. in ceiling/ floor voids. This allows identification of the operated device.
23900-K095 MiniDisc Remote Indicator
PAGE 61/120
www.kfp.co.uk
HOME
CONTENTS
ZOOM
PRINT
EXIT
61
DETECTION AND ALARM – MOUNTING ACCESSORIES
Mounting Accessories
CONDUIT BOX
A range of mounting accessories to supplement the Apollo detection range. Accessories are compatible with all Apollo detector ranges.
The Conduit Box is a versatile accessory for surface mounting Apollo bases. The box has knockouts to accept PG16 or M20 cable glands and conduit or minitrunking. Selftapping screws are included to fit the detector base to the conduit box.
•
Easy to install
•
Aesthetically pleasing
•
Protects against water ingress
•
Improved performance
•
Available in polycarbonate or metal
23900-K126 Conduit Box
DECKHEAD MOUNTING BOXES
Deckhead Mounting Boxes are robust units which can be used with various Apollo bases to protect against the ingress of water or other contaminants through the rear of the base.
23900-K201 Polycarbonate Deckhead Mounting Box 23900-K202 Metal Deckhead Mounting Box (has access ports threaded to fit M20 components)
6262/120 PAGE
Tel: +44 (0)1844www.kfp.co.uk 265003
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
DUCT DETECTOR ENCLOSURE
CEILING TILE MOUNTING BOX The Ceiling Tile Mounting Box has been designed to make the installation of detectors and sounders quick and easy prior to the fitting of a false ceiling. Detector and sounder bases can be fitted, wired and, if necessary, tested and commissioned before the installation of the false ceiling.
• •
No need for separate backbox Can be used with tiles up to 25mm thick
•
Quick and easy installation
The duct detector enclosure is designed to allow intelligent or conventional smoke detectors to provide detection of smoke within heating and ventilation (HVAC) ducts in commercial and industrial premises.
• • • •
Operates in air speeds of 0.5m/s to 20m/s Transparent cover to view detector LED Integral smoke test port Optional sampling tube lengths
The enclosure is supplied with either Discovery/ XP95 or Orbis detector bases (Detectors must be ordered separately), a sampling tube and exhaust tube. This allows the air from the duct to pass from the duct through the detector enclosure and back into the duct without contaminating the surrounding area.
23900-K199 Detector Ceiling Tile Mounting Box 23900-K200 Sounder Ceiling Tile Mounting Box
DIN-RAIL INTERFACE ENCLOSURES DIN-Rail Interface Enclosures are available in two sizes and can be used for housing intrinsically safe (IS) barriers or DIN-rail mounted interfaces. A multipurpose label that features a section for use with IS systems is supplied. For non-IS systems, the part referring to IS can simply be removed.
•
Allows multiple interfaces to be housed together
23900-H26
Duct Detector Enclosure including Discovery/XP95 mounting base and 360mm sample tube
TBA
Duct Detector Enclosure including Orbis mounting base and 360mm sample tube
23900-K168 Duct sample tube 762mm
23900-K227 DIN-Rail Interface Enclosure (4 units)
23900-K169 Duct sample tube 1524mm
23900-K228 DIN-Rail Interface Enclosure (10 units)
23900-K170 Duct sample tube 3048mm
PAGE 63/120
www.kfp.co.uk
HOME
CONTENTS
ZOOM
PRINT
EXIT
63
DETECTION AND ALARM – TEST EQUIPMENT
Test Equipment
FLAME DETECTOR MOUNTING BRACKET
The flame detector mounting bracket is an optional accessory for the XP95 Dual IR flame detector, part no. 23900-K092. The bracket is manufactured from stainless steel and is adjustable in two axis.
•
Allows flame detector to be moved to desired position
To keep a fire detection system in good working order, it should be subject to a routine maintenance program in accordance with locally applicable regulations. Over the course of a year every detector in the system should be functionally tested at least once, using recommended equipment. The Kidde range of test equipment enables the testing of both intelligent and conventional fire detection systems.
23900-K091 Flame Detector mounting bracket
6464/120 PAGE
Tel: +44 (0)1844www.kfp.co.uk 265003
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
XP95 TEST SET
DETECTOR EXTRACTION/INSERTION TOOL
A self contained portable test unit capable of providing a number of useful functions in relation to individual detectors, ancillary devices or complete circuits of analogue addressable devices in the XP95 range. The test set helps the engineer guarantee correct loop configuration before an active panel is installed.
The detector extraction/insertion tool allows removal or installation of detectors by using two rotating heads to grip and hold the detector. The detector can be safely removed or installed from floor level, removing the need for working at height. The product should be used with the telescopic or single extension poles.
• • •
User friendly LCD Speedy commissioning Reduces unnecessary site visits
NSANC50 XP95 test set, excluding printer and carry case
SMOKE DETECTOR TEST TOOL
Designed to give a thorough on-site check of series 60/65 conventional fire detectors. Each test set is supplied with a link head, mains adaptor and carrying case with shoulder strap.
The smoke detector test tool allows functional testing of smoke detectors. The tool consists of a large cup which is placed over the detector to be tested creating a chamber around the device, test smoke can then be sprayed into the chamber activating the detector.
Easy to use
• •
2 button select/accept options LCD for clear display
•
Suitable for use on angled ceilings
•
Lightweight
•
Test smoke not directed at detector preventing smoke saturation Clear cup allows visibility of detector LED Suitable for use on angled ceilings
• •
23900-K049 Smoke detector test tool (test gas not included)
23900-K010 Series 60/65 test set
PAGE 65/120
Universal design - suits most detectors
23900-K012 Detector extraction/insertion tool
SERIES 60/65 TEST SET
•
•
www.kfp.co.uk
HOME
CONTENTS
ZOOM
PRINT
EXIT
65
DETECTION AND ALARM – TEST EQUIPMENT
HEAT DETECTOR TEST TOOL
TELESCOPIC POLE
The heat detector test tool allows functional testing of heat detectors. The tool consists of a large cup which is placed over the detector to be tested creating a chamber around the device, the air in the chamber is then heated to the temperature required to activate the detector.
• • • •
Suitable for fixed temperature and rate of rise detectors Sets detectors into alarm within seconds Safe for use at low levels or height Suitable for use on angled ceilings
23900-K016 Heat detector test tool 240V
A telescopic extension pole for use with the detector extraction/insertion, smoke detector test and heat detector test tools. The pole extends from 1.26m to 4.5m enabling access to detectors fitted up to 6m high.
• • •
Toughened fibreglass Lightweight Allows access to detectors fitted up to 6m high
23900-K014 Telescopic extension pole 23900-K015 Carrying bag
SINGLE EXTENSION POLE
A 1.13m long pole for use with the detector extraction/insertion, smoke detector test and heat detector test tools.
• • •
Toughened fibreglass Lightweight Allows access to detectors fitted up to 2.5m high
23900-K013 Telescopic extension pole 23900-K015 Carrying bag
6666/120 PAGE
Tel: +44 (0)1844www.kfp.co.uk 265003
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
Conventional Audio/Visual Signalling Kidde offers a wide range of Audio/Visual signalling devices that can be connected to conventional sounder circuits on their Vega, Sirius II, FireBeta XT and FireBeta XT+ control panels. The Audio/Visual devices are separated into the following sections: • • • •
General purpose Bells Industrial Voice sounders
GENERAL PURPOSE SONOS ELECTRONIC SOUNDER A general purpose sounder certified to EN54. The sounder provides audibility up to 106 dB(A) at 1 metre with a choice of 32 switch selectable tones including all the major international standards. The sounder is constructed from flame retardant polycarbonate, with a deep base providing weatherproof protection to IP65.
• • • • • •
Simple ‘First Fix’ installation Synchronised alarm tones Volume control 20dB Quick connect and disconnect Weatherproof – IP65 Operating temperature -25oC to +70oC
• • •
Simple ‘First Fix’ installation Available with Red or Amber lens High efficiency LED beacon consumes less than 5mA Quick connect and disconnect Weatherproof – IP65 Operating temperature -25oC to +70oC
23906-H02 Sonos electronic sounder
GENERAL PURPOSE SONOS LED BEACON A general purpose low current LED beacon with a full faced, translucent case that provides a larger lens area and greater spread of light. The beacon is constructed from flame retardant polycarbonate, with a deep base providing weatherproof protection to IP65.
• • •
23906-K005 Sonos LED beacon – Red 23906-K004 Sonos LED beacon – Amber
PAGE 67/120
www.kfp.co.uk
HOME
CONTENTS
ZOOM
PRINT
EXIT
67
DETECTION AND ALARM – CONVENTIONAL AUDIO/VISUAL SIGNALLING
SONOS ELECTRONIC SOUNDER BEACON – RED
NEXUS INDUSTRIAL SOUNDER
A general purpose sounder beacon certified to ENS4 part 3. The sounder beacon provides audibility up to 106 dB(A) at 1 metre with a choice of 32 switch selectable tones including all the major international standards. The sounder uses a low current LED beacon with a full faced, translucent case that provides a larger lens area and greater spread of light. The sounder beacon is constructed from flame retardant polycarbonate, with a deep base providing weatherproof protection to IP65.
• • • • • • •
Simple ‘First Fix’ installation Sounder and Beacon can be controlled independently High efficiency LED beacon consumes less than 5mA Volume control 20dB Quick connect and disconnect Weatherproof – IP65 Operating temperature -25oC to +70oC
A high output, low current consumption ENS4 part 3 approved sounder suitable for industrial applications it provides audibility up to 110dB(A) at 1 metre. 64 switch selectable tones are available including all the major international standards The IP66 construction makes it suitable for almost any location.
• • • •
‘First fix’ wire to base technology Volume control 20dB Three Alarm stages Operating temperature -25oC to +70oC
23906-K006 Nexus Industrial Sounder, 110dB(A)
23905-K009 Sonos electronic sounder beacon – Red
NEXUS INDUSTRIAL SOUNDER BEACON MOTORISED BELL The motorised bell is designed for fire alarm applications and is approved to ENS4 part 3. Designed for ease of installation, it features a robust steel gong available in two sizes 6” or 8”. The motorised bell is available in weatherproof version. 23905-H02
Motorised bell 6”
23905-H03
Motorised bell 8”
• • • • •
Low current consumption – 20mA Universally recognisable sound Diode polarised 6” or 8” gong Operating temperature -10oC to +55oC
23905-K019 Weatherproof motorised bell 6” 23905-K020 Weatherproof motorised bell 8”
6868/120 PAGE
Tel: +44 (0)1844www.kfp.co.uk 265003
A combined sounder beacon device which utilises the high output, low current consumption sounder with a high efficiency red LED beacon suitable for industrial applications. The sounder provides audibility up to 110dB(A) at 1 metre with a choice of 64 switch selectable tones including all the major international standards. The IP66 construction makes it suitable for almost any location.
• • • • • •
First fix’ wire to base technology Volume control 20dB Three Alarm stages Low in-rush current Static/flashing beacon mode Operating temperature -25oC to +70oC
Approved to ENS4 part 3. 23906-K023 Nexus Industrial Sounder, Beacon, Red lens
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
FIRE ALARM INTERFACE CONTROL UNIT Designed to be used in conjunction with Sonos voice sounders the fire alarm interface control unit monitors the status of the sounder circuits on the fire alarm control panel, and relays the appropriate signal to the voice sounders. The interface control unit is constructed from flame retardant polycarbonate, with protection to IP65.
SONOS VOICE SOUNDER
• • • • •
Alert, evacuate, test and all clear messages for each stage of alarm No additional wiring Fully synchronised voice messages System status indicators Simple operation
Combines normal sounder signals with a clear, synchronised voice message to help reduce confusion and distress during an alarm. Provided with 3 pre-programmed messages as standard it can also transmit a further 4 messages when used with an interface control unit. The sounder is constructed from flame retardant polycarbonate, with a deep base providing weatherproof protection to IP65.
• • •
Automatic synchronisation 106dB(A) tone and 80dB(A) message output Easy retrofit to existing installations
• • •
Automatic synchronisation 106dB(A) tone and 80dB(A) message output Full faced, translucent case gives larger lens area for greater spread of light Easy retrofit to existing installations
53836-K265 Fire Alarm Interface control unit 23906-K009 Sonos voice sounder
GAS EXTINGUISHING INTERFACE CONTROL UNIT
SONOS VOICE SOUNDER BEACON
Designed to be used in conjunction with Sonos voice sounders and the Nexus voice sounder beacon (gas extinguishing). The gas extinguishing interface control unit monitors the status of 1st and 2nd stage sounder circuits on the extinguishing control panel, and relays the appropriate signal to the voice sounders. The interface control unit is constructed from flame retardant polycarbonate, with protection to IP65.
The voice sounder beacon provides all the features of the voice sounder combined with a red high efficiency LED beacon. Provided with 3 pre-programmed messages as standard it can also transmit a further 4 messages when used with an interface control unit. The sounder is constructed from flame retardant polycarbonate, with a deep base providing weatherproof protection to IP65.
• • • • •
Alert, gas release imminent, gas released and gas hold messages for each stage of alarm No additional wiring Fully synchronised voice messages System status indicators Simple operation
53836-K264 Gas extinguishing interface control unit
PAGE 69/120
www.kfp.co.uk
•
23906-K009 Sonos voice sounder beacon, red lens
HOME
CONTENTS
ZOOM
PRINT
EXIT
69
DETECTION AND ALARM – CONVENTIONAL AUDIO/VISUAL SIGNALLING
NEXUS INDUSTRIAL VOICE SOUNDER
NEXUS INDUSTRIAL VOICE SOUNDER BEACON – GAS EXTINGUISHING
Combines normal sounder signals with a clear, synchronised voice message to help reduce confusion and distress during an alarm. The sounder is provided with 4 pre-programmed fire alarm messages as standard, alternative messages can be selected from an extensive message library. A USB port is provided on the sounder allowing custom messages in WAV format to be downloaded from a PC. The sounder is constructed from flame retardant polycarbonate, with a deep base providing weatherproof protection to IP66.
• • • • •
Automatic synchronisation Choice of up to 7 messages via three volt free contacts 110dB(A) tone and 90dB(A) message output Download messages in-house via built-in USB port Easy retrofit to existing installations
23906-K010 Nexus industrial voice sounder
This device is used in conjunction with the Gas extinguishing Interface Control unit, the interface control unit monitors the 1st and 2nd stage sounder outputs and on action selects the message the sounder plays. Provided with 4 pre-programmed messages as standard, alternative messages can be selected from an extensive message library. The sounder is constructed from flame retardant polycarbonate, providing weatherproof protection to IP66.
• • • • •
Automatic synchronisation Choice of up to 7 messages via three volt free contacts 110dB(A) tone and 90dB(A) message output High efficiency LED beacon Easy retrofit to existing installations
23906-K023 Nexus industrial sounder beacon, Gas Extinguishing
NEXUS INDUSTRIAL VOICE SOUNDER BEACON – FIRE ALARM The Nexus Industrial voice sounder beacon provides all the features of the Nexus Industrial voice sounder combined with a red high efficiency LED beacon. Provided with 4 preprogrammed messages as standard, alternative messages can be selected from an extensive message library. The sounder is constructed from flame retardant polycarbonate, with a deep base providing weatherproof protection to IP66.
• • • • •
Automatic synchronisation Choice of up to 7 messages via three volt free contacts 110dB(A) tone and 90dB(A) message output High efficiency LED beacon Easy retrofit to existing installations
23906-K011 Nexus industrial voice sounder beacon, Fire Alarm
7070/120 PAGE
Tel: +44 (0)1844www.kfp.co.uk 265003
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
Conventional Manual call points Kidde offers a wide range of Manual Call Points that can be connected to their, Sirius II, FireBeta XT and FireBeta XT+ control panels. The range of call points includes: • • •
Standard Weatherproof Extinguishing release
STANDARD MANUAL CALL POINT
Red colour surface mount manual call point used for manually activating the alarm condition on a fire alarm system. The call point can be fitted with either a break glass element or flexible operating element. The call point comes fitted with a 470Ω alarm resistor, compatible with the Kidde conventional control panel range. 23908-H01
• • • •
Unique ‘plug & play’ installation concept Anti-Tamper facility Enhanced aesthetics Available with English/Arabic text
Manual Call Point, Red, surface mount
23908-K026 Manual Call Point, Red, surface mount, English/Arabic text
WEATHERPROOF MANUAL CALL POINT The Weatherproof Manual Call Point is an IP67 sealed version of the standard manual call point. The enhanced environmental protection allows the unit to be installed in many external environments where water and dirt are likely to be present.
23908-H02
• • • •
Unique ‘plug & play’ installation concept Anti-Tamper facility Enhanced aesthetics Available with English/Arabic text
Weatherproof Manual Call Point, Red
23908-K025 Weatherproof Manual Call Point, Red, English/Arabic text
PAGE 71/120
www.kfp.co.uk
HOME
CONTENTS
ZOOM
PRINT
EXIT
71
DETECTION AND ALARM – DOOR RELEASE AND BATTERIES
EXTINGUISHING RELEASE MANUAL CALL POINT For use with the Kidde FireBeta XT/XT+ extinguishing control panels the call point provides the facility to manual activate the extinguishing release sequence. The call point is yellow with identifying text ‘Extinguishing release’ and comes fitted with a 470Ω alarm resistor.
• • •
Unique ‘plug & play’ installation concept Anti-Tamper facility Enhanced aesthetics
Door release Equipment In many buildings emergency fire doors are held in the open position using electromagnetic devices until the fire alarm sounds. On an alarm condition the control panel will initiate the release of these electromagnetic devices allowing the doors to close limiting the spread of smoke and fire through the building. Applications include:
23908-H03 Extinguishing release manual call point
Hospitals Large office buildings Hotels
MCP ACCESSORIES
23908-H04
Replacement glass elements, English text, pack of 5
23908-K027 Replacement glass elements, English/Arabic text, pack of 5 23900-K215 Replacement flexible operating elements 23908-H05
7272/120 PAGE
Spare test keys, pack of 10
Tel: +44 (0)1844www.kfp.co.uk 265003
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
ELECTROMAGNETIC DOOR RELEASE UNIT
Surface mounting door release unit with a holding force of 40kg, a release button is provided for manual release of the electromagnetic device. The unit also requires a floor mounted bracket.
SEALED LEAD ACID BATTERIES
• • • • •
24 Vdc 75mA 40Kg holding force Manual release button Spring ejector Door plate supplied
23911-H12 Magnetic door release unit 23911-H02 Floor bracket for magnetic door release unit
A range of sealed lead acid batteries that can be used with the Kidde range of control panels, each Kidde panel would require 2 x 12v batteries. Kidde panels are designed with space to install back-up batteries, if battery space is insufficient for the calculated battery requirements a separate battery enclosure would be required. Battery calculations are the responsibility of the system designer based on the panel loadings and battery back-up requirements determined by the specification. Dimensions of batteries are shown in brackets (H x W x L). 23911-K001 3Ah SLA batteries (134 x 67 x 60.5)
Sealed Lead Acid Batteries
23911-H09
7Ah SLA batteries (151 x 65 x 94)
23911-H10
12Ah SLA batteries (151 x 98 x 95)
23911-H11
17Ah SLA batteries (181.5 x 77 x 167.5)
23911-K003 24Ah SLA batteries (166.5 x 176 x 112) 23911-K004 40Ah SLA batteries (197 x 165 x 170)
Kidde provide a range of rechargeable sealed lead acid batteries to provide back-up battery supplies for their range of control equipment.
PAGE 73/120
www.kfp.co.uk
HOME
CONTENTS
ZOOM
PRINT
EXIT
73
DETECTION AND ALARM – INTRINSICALLY SAFE DETECTORS
Intrinsically Safe Detectors
XP95 IS Intrinsically Safe Detectors
There are many places where an explosive mixture of air, gas or vapour is, or may be present either continuously, intermittently or as a result of an accident. These are defined as hazardous areas by BS EN 60079, the code of practice for installation and maintenance of electrical apparatus in potentially explosive atmospheres.
XP95 Intrinsically Safe (IS) detectors are a development of the well established intelligent XP95 range from Kidde. XP95 IS detectors feature all the benefits of the standard range, but are developed specifically for use in hazardous areas. The addresses of XP95 IS detectors are set by means of the patented XPERT card.
Hazardous areas are common in petroleum and chemical engineering plants and in factories processing and storing gases, solvents, paints and other volatile substances. Electrical equipment for use in these areas needs to be designed so that it cannot ignite an explosive mixture, not only in normal operation but also in fault conditions. There are a number of methods available to achieve this but one of the most common is intrinsic safety. Kidde offers both convential and intelligent smoke and heat detector ranges designed to be intrinsically safe, as they meet the requirements of the ATEX directive.
7474/120 PAGE
Tel: +44 (0)1844www.kfp.co.uk 265003
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
XP95 IS IONISATION SMOKE DETECTOR
The XP95 IS Ionisation Smoke Detector uses a low activity radioactive foil to detect fires by irradiating the air in the smoke chambers and causing a current flow. If smoke enters the chamber, the current flow is reduced leading to an alarm.
XP95 IS HEAT DETECTOR
• • •
Responds well to fast-burning, flaming fires Designed to operate in a variety of environments Minimal effects from temperature, humidity atmospheric pressure and wind
•
Ideal for environments that are dirty or smoky under normal conditions. Unaffected by wind or atmospheric pressure
XP95 IS MANUAL CALL POINT – STANDARD TYPE
XP95 IS OPTICAL SMOKE DETECTOR • • •
Responds well to slow-burning, smouldering fires Well suited for escape routes Unaffected by wind or atmospheric pressure
23900-K045 XP95 IS Optical Smoke Detector
PAGE 75/120
•
23900-K047 XP95 IS Heat Detector
23900-K046 XP95 IS Ionisation Smoke Detector
The XP95 IS Optical Smoke Detector works using the light scatter principle and is ideal for applications where slow-burning or smouldering fires are likely.
The XP95 IS Heat Detector operates by measuring temperature levels with a single thermistor network which gives a count output proportional to the external air temperature.
The XP95 IS Manual Call Point is based on the standard weatherproof model. It features an ‘interrupt’ facility to provide fast response to an alarm.
• •
Reports an alarm in under 0.2 seconds IP66 rated enclosure
23900-K048 XP95 IS Manual Call Point Standard without flap – Red
www.kfp.co.uk
HOME
CONTENTS
ZOOM
PRINT
EXIT
75
DETECTION AND ALARM – INTRINSICALLY SAFE DETECTORS
XP95 IS MOUNTING BASE
XP95 IS MANUAL CALL POINT – MEDC STYLE The MEDC style Manual Call Point is recommended for heavy duty applications. This model is made of glass-reinforced polyester.
• • •
Reports address in under 0.2 seconds IP66 rated enclosure Robust design
23900-K206 XP95 IS Manual Call Point MEDC Style – Break Glass – Red
The Xp95 IS Mounting Base has been designed to accept only IS products. This ensures that standard detectors cannot inadvertently be fitted into an intrinsically safe system. EXPERT cards are supplied with all bases.
• • •
XPERT addressing One way fit Only accepts IS detectors
23900-K138 XP95 IS Mounting Base
PROTOCOL TRANSLATOR AND GALVANIC BARRIER
The Protocol Translator and Galvanic Barrier are installed in the safe area ensuring integrity of communication between control equipment and field devices and safety within the limits of BASEEFA approvals.
• •
Loop powered Translates voltage levels from a loop driver to be compatible with IS requirements.
23900-K139 XP95 Protocol Translator (single channel) 23900-K140 XP95 Protocol Translator (dual channel) 23900-K082 Galvanic Barrier
7676/120 PAGE
Tel: +44 (0)1844www.kfp.co.uk 265003
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
ORBIS IS OPTICAL SMOKE DETECTOR
ORBIS IS Detector range Orbis IS is a range of conventional detectors which have been developed from the standard Orbis smoke and heat detectors Orbis IS is a range with modern styling and is electronically compatible with Apollo series 60 intrinsically safe conventional detectors.
The Orbis IS Optical smoke detector works using the light scatter principle and is ideal for applications where slow-burning or smouldering fires are likely.
• • • • •
Reduces false alarms Recommended for early warning of fire in most areas Improved sensitivity to black smoke Compensation for slow changes in sensitivity Algorithms for reliability of alarm
23900-K214 Orbis IS Optical Smoke Detector
Features include: • • • •
Timesaver base® Patented FasTest® enabling functional testing in four seconds DirtAlert® indicates limit of drift compensation Tolerates extreme operating conditions: -40oC to +70oC
ORBIS IS MULTISENSOR SMOKE DETECTOR
• False alarm reduction
The Orbis IS Multisensor Detector benefits from the same false alarm technology as the Optical Detector. It is a thermally enhanced smoke detector so will not give an alarm from heat alone.
• • • • •
Reduces false alarms Sensitive to fast burning, flaming fires Improved sensitivity to black smoke Compensation for slow changes in sensitivity Algorithms for reliability of alarm
23900-K213 Orbis IS Multisensor Smoke Detector
PAGE 77/120
www.kfp.co.uk
HOME
CONTENTS
ZOOM
PRINT
EXIT
77
DETECTION AND ALARM – INTRINSICALLY SAFE DETECTORS
ORBIS IS HEAT DETECTOR
ORBIS IS TIMESAVER BASE
The Orbis IS Heat Detector monitors temperature by using a single thermistor network which provides a voltage output proportional to the external air temperature. The Orbis IS range incorporates seven heat detector classes to suit a wide range of operating conditions.
• • • •
Can be used for applications where smoke detectors are unsuitable. Ideal for environments that are dirty or smoky under normal conditions Reduced incidences of false alarms Increased reliability of detection
• • • •
Grouped terminals to make wiring easy Two fixing centres LED alignment mark Detector locking mechanism
23900-K223 Orbis IS TimeSaver Base
ORBIS IS HEAT DETECTOR 23900-K207
Rate-of-Rise MAT 50 C A1R - Standard
23900-K208
Static MAT 50 C A2S - Standard
23900-K209
Rate-of-Rise MAT 65 C BR - Standard
23900-K210
Static MAT 65 C BS - Standard
23900-K211
Rate-of-Rise MAT 80 C CR - Standard
23900-K212
Static MAT 80 C CS - Standard
DUAL CHANNEL GALVANIC ISOLATOR
MAT (Maximum Application Temperature)
7878/120 PAGE
The IS TimeSaver® Base is a completely new design that provides installers with an open working area with fixing holes shaped to allow a simple mounting procedure.
Tel: +44 (0)1844www.kfp.co.uk 265003
The dual channel galvanic isolator is essential when connecting IS devices to the zone circuit of a conventional fire alarm panel. The Galvanic isolator provides protection between the safe area where the panel is located and the hazardous area where the detectors are located. One dual channel galvanic isolator will protect up to two conventional detection zones.
• •
Straightforward ‘clip-on’ DIN-rail mounting Simplified installation and maintenance using plug-in connectors
23911-K055 Dual Channel Galvanic Isolator
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
Intrinsically Safe Audio/Visual Signalling A range of intrinsically safe sounders, beacons and sounder beacon combination units compatible with the Kidde range of control panels for use in hazardous environments.
SYREX IS SOUNDER
A low current intrinsically safe sounder with audibility up to 100dB(A) at 1 metre and 49 switch selectable tones. The sounder is constructed from high impact ABS flame retardant material, weatherproof to IP65.
• • • • •
Rated for category 1 use ATEX approved Ex II 1G EExia IIC T4 Auto synchronised sound output Volume control
Important! The IS sounder must be used with a certified galvanic isolator or zener barrier.
23906-K007 Syrex IS sounder 100dB(A)
SYREX IS BEACON – RED
An intrinsically safe beacon containing 6 high intensity LEDs and a prismatic lens for effective visual warning in hazardous area applications. The beacon is constructed from high impact ABS flame retardant material, weatherproof to IP65.
• • •
Rated for category 1 use ATEX approved Ex II 1G EExia IIC T4
Important! The IS sounder must be used with a certified galvanic isolator or zener barrier. 23906-K008 Syrex IS beacon
PAGE 79/120
www.kfp.co.uk
HOME
CONTENTS
ZOOM
PRINT
EXIT
79
DETECTION AND ALARM – INTRINSICALLY SAFE DETECTORS
SYREX IS-SB SOUNDER BEACON – RED LENS A combination unit consisting of a sounder with audibility up to 100dB(A) at 1 metre, 49 switch selectable tones and high intensity LED beacon. The sounder beacon is constructed from high impact ABS flame retardant material, weatherproof to IP65.
• • • • • •
Rated for category 1 use ATEX approved Ex II 1G EExia IIC T4 Array of 6 high intensity LEDs Auto synchronised sound output Volume control
23905-K022 Syrex IS-SB Sounder beacon, 100dB(A), Red lens
SHUNT DIODE SAFETY BARRIER
The shunt diode safety barrier is required when intrinsically safe sounders or beacons are connected to the sounder circuits on the Kidde range of control panels. The barrier provides protection between the safe area where the panel is located and the hazardous area where the sounders or beacons are located.
• •
Straightforward ‘clip-on’ DIN-rail mounting Simplified installation and maintenance using plug-in connectors
TBA Shunt diode safety barrier
8080/120 PAGE
Tel: +44 (0)1844www.kfp.co.uk 265003
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
PAGE 81/120
www.kfp.co.uk
HOME
CONTENTS
ZOOM
PRINT
EXIT
81
ASPIRATING SMOKE DETECTION
8282/120 PAGE
Tel: +44 (0)1844www.kfp.co.uk 265003
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
Kidde High Sensitivity Smoke Detection systems (HSSD) are Aspirating Smoke Detection systems (ASD) designed to give very early indication of an incipient fire condition. This pre-emptive warning – before the transition into the flaming and heat stages – provides the time necessary to take corrective action and avoid the danger, damage and disruption to operations that a fire can cause. The Kidde HSSD equipment is simple to install, commission, operate and service. They have the highest levels of performance and reliability.
PAGE 83/120
Protecting assets worldwide
Protecting your investment
Developed in 1988, Kidde HSSD was the world’s first laser-based detector. They are in use worldwide, protecting valuable assets for institutions and companies as diverse as Windsor Castle, London Underground, BP and HSBC bank.
There are major benefits from a very early indication of incipient fire. The incident can be dealt with through local corrective measures such as powering down equipment or the use of hand extinguishers, avoiding unnecessary evacuation or suppressant release. Kidde HSSD systems can also be integrated into the main fire protection system, providing the first stage alert in an alarm organisation, with subsequent stages of alarm being set for suppressant release or evacuation.
www.kfp.co.uk
HOME
CONTENTS
ZOOM
PRINT
EXIT
83
ASPIRATING SMOKE DETECTION
Where to use High Sensitivity Smoke Detection 8484/120 PAGE
Tel: +44 (0)1844www.kfp.co.uk 265003
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
Kidde HSSD provides total protection in critical applications: • When downtime must be minimised • Where smoke is difficult to detect • In extreme environmental conditions • Where appearances are important • When extra time is necessary
Where appearances are important and preservation of priceless objects is a priority: • Modern offices • Heritage buildings • Cathedrals • Museums • Libraries
Where smoke is difficult to detect in areas with high ceilings or high air flow: • Atria • Warehouses • Cold storage • Indoor stadiums
PAGE 85/120
When downtime must be minimized with high cost equipment: • Clean rooms • Computer rooms • Telecommunications • Broadcast facilities
www.kfp.co.uk
HOME
CONTENTS
In extreme environments that pose a problem to point type smoke detection: • Power stations • Mines • Offshore
When extra time is necessary to effect safe and orderly evacuation: • Airports • Underground railway systems • Hospitals • Theatres • Cinemas
ZOOM
PRINT
EXIT
85
ASPIRATING SMOKE DETECTION
Stages of fire Most fires start with some form of overheating. In this incipient stage, fine particles are released as the combustion process begins. The particles released at the incipient stage of a fire may not be detected by point type smoke or heat detectors. In fact smouldering can continue for minutes, hours or even days before being detected by point type detectors. The incipient stage of smouldering fires provides the widest window of opportunity to detect and control the spread of fire.
How High Sensitivity Smoke Detection works
8686/120 PAGE
The HSSD unit will go through various alarm thresholds in these early stages, long before point type smoke detectors will respond to the fire. Point type smoke detectors are designed to detect smoke at a level which
Tel: +44 (0)1844www.kfp.co.uk 265003
E-mail:
[email protected] CONTENTS HOME
allows sufficient time for occupants to evacuate the area or building, although possibly not enough time to prevent damage to equipment. At this level there may also be an increased risk to anyone attempting to extinguish the fire. HSSD units can be programmed to be up to 1000 times more sensitive than point type smoke detectors. Alarm levels can be set as high as 0.0025% obscuration per metre for clean areas and lower sensitivity for less controlled environments. This increased sensitivity allows the HSSD unit to detect and report an incident at the earliest possible stage, providing the time needed to help minimise or prevent fire damage.
Web:ZOOM www.kfp.co.uk PRINT
EXIT
Aspirating detection The HSSD detector is mounted either inside or outside the area. It draws air from the protected area using an aspirating fan which is housed in the detection unit. The pipe network contains sampling holes at predetermined locations through which the air is drawn. HSSD detectors can protect areas up to 2000 square metres to BS5839, or between 500 to 750 square metres to BS6266, in high air flow conditions. The pipework is configured in various ways according to the application. Typically it will comprise of a pipe network with sampling points at intervals similar to point detection. It can also, for example, be arranged to monitor across air handling units or in ducts. FACTORY
ELECTRONIC DATA PROCESSING
PAGE 87/120
www.kfp.co.uk
HOME
CONTENTS
ZOOM
PRINT
EXIT
87
ASPIRATING SMOKE DETECTION
Senator High Sensitivity Smoke Detection embodies innovative features which depart from the accepted techniques for detectors operating at high sensitivity.
SENATOR High Sensitivity Smoke Detection
An extensive range of detection units and accessories make the Senator HSSD system one of the most flexible on the market. The most important feature of the Senator range of detectors is the patented ‘artificial intelligence’ known as ClassiFire-3D.
Senator 25 High sensitivity, small area detection unit Senator 100 High sensitivity, Medium area detection unit Senator 200 High sensitivity, large area detection unit Senator Ex Hazardous area detection unit
Classifire-3D Classifire-3D is a process which controls all aspects of the system, ensuring the maximum safe sensitivity regardless of ambient conditions. During an initial Fastlearn process, the detector samples the environment once each second and produces a histogram representing the ambient pollution level. The histogram fits a standard deviation curve, allowing statistical analysis of the data. Any normal curve can be divided into 3 equal width strips called a standard deviation with a known probability of a random event falling into each category. Classifire-3D uses this information to automatically set the correct sensitivity and alarm thresholds, determined by an acceptable frequency of false alarms.
Features • Wide range of detector types • High sensitivity provided by laser based forward light scatter for reliable early warning • Unique Classifire-3D perceptive artificial intelligence system • Laser Dust Discrimination (LDD) with a patented dust management and separator system • RS485 communications built into detector as standard for networking and remote communications • Addressable Protocol Interface card APICTM for connecting detector to Apollo protocol control panels • SenseNET network of 127 detectors • Command module available for central monitoring and display
After 24 hours ClassiFire-3D has sufficient data to set the alarm position at its best safe sensitivity. ClassiFire-3D continues to update the histogram for the entire lifetime of the detector.
8888/120 PAGE
Tel: +44 (0)1844www.kfp.co.uk 265003
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
SENATOR 25
SENATOR 100
Senator 25 High Sensitivity Smoke Detector provides cost effective, very early warning smoke detection in small area applications. A single sampling pipe of 50m maximum length can be connected to the detector unit.
Senator 100 High Sensitivity Smoke Detector provides cost effective, very early warning smoke detection in medium size applications. Two 50m sampling pipes or a single pipe of 100m maximum length can be connected to the detector unit.
Senator 25 is supplied in a docking station allowing easy first fix installation of sampling pipes and cables. Volt free change over relays provide the facility to interface the Senator 25 into the site fire alarm system. Programmable options such as alarm levels and delays, latching or non-latching alarms, high and low airflow levels are available when using a PC and the Senator Remote programming software. The Senator 25 is compatible with the SenseNET network and Command modules. Approved to EN54.20.
Senator 100 is supplied in a docking station allowing easy first fix installation of sampling pipes and cables. Volt free change over relays provide the facility to interface the Senator 100 into the site fire alarm system. Programmable options such as alarm levels and delays, latching or non-latching alarms, high and low airflow levels are available when using a PC and the Senator Remote programming software. The Senator 100 is compatible with the SenseNET network and Command modules. Approved to EN54.20.
Technical specification
Technical specification
Dimensions Weight Enclosure rating Operating temperature Operating humidity Voltage requirements Quiescent current Indications Relay outputs Inputs Sensitivity range
140W x 200H x 85D 1.85Kg IP50 -10 to 60oC 0 to 90% RH, non condensing 21.6 to 26.4V dc 250mA Fire, Fault and OK 2 x 500mA @ 30V dc – Alarm, Fault (energised) Additional relays available when using Relay/Input card RS485 for network connections APIC address terminals for addressable loop (Requires APIC addressable interface card) Min 25%, Max 0.02% ob/m
Dimensions Weight Enclosure rating Operating temperature Operating humidity Voltage requirements Quiescent current Indications Relay outputs Inputs Sensitivity range
300W x 220H x 90D 3.8Kg IP50 -10 to 60oC 0 to 90% RH, non condensing 21.6 to 26.4V dc 400mA Fire, Fault and OK 2 x 500mA @ 30V dc – Alarm, Fault (energised) Additional relays available when using Relay/Input card RS485 for network connections APIC address terminals for addressable loop (Requires APIC addressable interface card) Min 25%, Max 0.02% ob/m
30671-KID
SENATOR 25 including docking station
30672-KID
SENATOR 100 including docking station
30760-KID
SENATOR 25 including docking station and relay/input card
30764-KID
SENATOR 100 including docking station and relay/input card
PAGE 89/120
www.kfp.co.uk
HOME
CONTENTS
ZOOM
PRINT
EXIT
89
ASPIRATING SMOKE DETECTION
SENATOR 200
SENATOR 200 WITH COMMAND MODULE
The Senator 200 High Sensitivity Smoke Detector provides cost effective, very early warning smoke detection in large area applications. Four sampling pipes of 50m maximum length each or two sampling pipes of 100m maximum length each can be connected to the detector unit. LCD display and cursor controls are provided which allow programming of the unit without any additional programmers or PC. Volt free change over relays provide the facility to interface the Senator 200 into the site fire alarm system. Programmable options such as alarm levels and delays, latching or non-latching alarms, airflow normalisation, high and low airflow levels and automatic sensitivity setup are available in the programming options. The Senator 200 is available in a number of variants and is compatible with the SenseNET network. Approved to EN54.20.
This variant of the Senator 200 detector unit is provided with a built in command module, allowing it to provide single location display, control and interfacing options for up to 127 networked Senator detectors.
Technical specification Dimensions Weight Enclosure rating Operating temperature Operating humidity Voltage requirements Quiescent current Indications Relay outputs Inputs Sensitivity range 30621-KID
9090/120 PAGE
427W x 372H x 95D 5.2Kg IP50 -10 to 60oC 0 to 90% RH, non condensing 21.6 to 26.4V dc 300mA (Fan speed 1), 470mA (Fan speed 8), 750mA (Fan speed 16) LCD status display LEDs : Aux Alarm, Pre-Alarm, Fire Alarm, Fire 2, Fault, OK, 26 segment bargraph 5 x 500mA @ 30V dc – Fire 1, Fire 2, Pre-alarm, Aux alarm, Fault (energised) RS485 for network connections APIC address terminals for addressable loop (Requires APIC interface card) Min 25%, Max 0.02% ob/m
SENATOR 200 detector
Tel: +44 (0)1844www.kfp.co.uk 265003
A larger LCD display is provided to display more information relating to the SenseNET network. Approved to EN54.20. Technical specification Dimensions Weight Enclosure rating Operating temperature Operating humidity Voltage requirements Quiescent current Indications Relay outputs Inputs Sensitivity range
30620-KID
427W x 372H x 95D 5.3Kg IP50 -10 to 60oC 0 to 90% RH, non condensing 21.6 to 26.4V dc 750mA (Fan speed 1), 920mA (Fan speed 8), 1.5A (Fan speed 16) LCD status display LEDs : Aux Alarm, Pre-Alarm, Fire Alarm, Fire 2, Fault, OK, 26 segment bargraph 5 x 500mA @ 30V dc – Fire 1, Fire 2, Pre-alarm, Aux alarm, Fault (energised) RS485 for network connections APIC address terminals for addressable loop (Requires APIC interface card) Min 25%, Max 0.02% ob/m
SENATOR 200 detector with Command Module
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
SENATOR 200 STEEL ENCLOSURE
SENATOR 200 WITH MINIMUM DISPLAY
Identical to 30621-KID the rugged sheet steel enclosure provides added protection for the Senator 200 detector in harsh environments. Approved to EN54.20.
This is an economy version of the Senator 200 detector provided in a rugged sheet steel enclosure. The unit provides basic LED indications for alarm, fault and normal status. Programming is available through RS485 serial connection or Command Module. Approved to EN54.20
30706-KID
SENATOR 200 detector – steel enclosure
Technical specification Dimensions Weight Enclosure rating Operating temperature Operating humidity Voltage requirements Quiescent current Indications Relay outputs Inputs
SENATOR 200 WITH COMMAND MODULE STEEL ENCLOSURE
Sensitivity range
427W x 372H x 95D 5.3Kg IP50 -10 to 60oC 0 to 90% RH, non condensing 21.6 to 26.4V dc 450mA @ 24V dc at fan speed 8 LED indications “OK”, “Fault” and “Fire” 5 x 500mA @ 30V dc – Fire 1, Fire 2, Pre-alarm, Aux alarm, Fault (energised) RS485 for network connections APIC address terminals for addressable loop (Requires APIC addressable interface card) Min 25%, Max 0.02% ob/m
Identical to 30620-KID the rugged sheet steel enclosure provides added protection for the Senator 200 detector with Command Module in harsh environments. Approved to EN54.20.
30707-KID
PAGE 91/120
SENATOR 200 detector with Command Module – steel enclosure
www.kfp.co.uk
30710-KID
HOME
SENATOR 200 with minimum display
CONTENTS
ZOOM
PRINT
EXIT
91
ASPIRATING SMOKE DETECTION
SENATOR EX
SENATOR STAND ALONE COMMAND MODULE
Senator Ex is a reliable very high sensitivity smoke detector for use in Hazarduous areas. The detector is supplied in either a cast aluminium or stainless steel enclosure. Approvals: ATEX rated EEx d IIB +H2 T3, equipment group 2 (Zones 1, 2 and 3), group gases A and B + Hydrogen. An external particle filter is provided allowing ease of maintenance without declassifying the area. Upgradeable Fire and Fault relay outputs are available for interfacing to other fire alarm equipment.
Senator Command Module provides a single location display, control and interfacing option for systems of up to 127 detectors. The Command module allows global programming of all detector functions simultaneously.
Technical specification Dimensions Weight Enclosure rating Operating temperature Operating humidity Voltage requirements Quiescent current Indications Relay outputs Inputs Sensitivity range
400W x 200H x 165D inc. flame arrestors 8.5Kg IP65 -10 to 60oC 0 to 90% RH, non condensing 21.6 to 26.4V dc 1.1A @ 24V dc LED indications “OK”, “Fault” and “Fire” 2 x 500mA @ 30V dc – Fire, Fault (energised) RS485 for network connections APIC address terminals for addressable loop (Requires APIC addressable interface card) Min 25%, Max 0.0015% ob/m
An internal bargraph automatically displays the status of the detector with the highest alarm level. The Command Module is provided with an integral serial interface programmable for TAP text messages/Paging or BACnet BMS communications. Available with or without an internal power supply. Technical specification Dimensions Weight Enclosure rating Operating temperature Operating humidity Voltage requirements Quiescent current Indications Relay outputs Inputs
427W x 372H x 95D 6.2Kg (10.1Kg with batteries) IP50 -10 to 60oC 0 to 90% RH, non condensing without PSU - 21.6 to 26.4V dc with PSU – 230V input, mains fuse 3A 250mA @ 24V dc LCD status display LEDs : Aux Alarm, Pre-Alarm, Fire Alarm, Fire 2, Fault, OK, 26 segment bargraph 5 x 500mA @ 30V dc – Fire 1, Fire 2, Pre-alarm, Aux alarm, Fault (energised) RS485 for network connections APIC address terminals for addressable loop (Requires APIC addressable interface card)
30731-KID
SENATOR Ex
30623-KID
SENATOR Command Module with PSU
30732-KID
SENATOR Ex – stainless steel enclosure
30624-KID
SENATOR Command Module without PSU
9292/120 PAGE
Tel: +44 (0)1844www.kfp.co.uk 265003
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
SENATOR STAND ALONE COMMAND MODULE STEEL ENCLOSURE
SENATOR REMOTE DISPLAY UNIT (RDU)
Identical to 30623-KID and 30624-KID the rugged sheet steel enclosure provides added protection for the Senator Command Module in harsh environments.
The Senator remote display unit connects to the Senator range of detectors using the RS485 data bus and mimics the LED status indications of the detector. The RDU monitors the status of a single detector.
30708-KID
SENATOR Command Module with PSU – steel enclosure
30709-KID
SENATOR Command Module without PSU – steel enclosure
More than one RDU can be allocated to a single detector. The RDU can be mounted in either a single wall mounted enclosure or a 19” rack enclosure. Up to 8 RDUs can be mounted in a single 19” sub frame. An optional relay board is available for use with the RDU. Technical specification Dimensions Operating temperature Operating humidity Voltage requirements Quiescent current Indication
SENATOR 19” RACK MOUNT COMMAND MODULE Senator command module which is designed to be installed in a 19” rack type enclosure.
3U High -10 to 60oC 0 to 90% RH, non condensing Nominal 24V dc, range 18-30V dc 40mA LEDs : Aux Alarm, Pre-Alarm, Fire 1, Fire 2, Fault, OK, 26 segment bargraph
Technical specification Dimensions Operating temperature Operating humidity Voltage requirements Quiescent current 30814-KID
PAGE 93/120
3U High x 80mm deep -10 to 60oC 0 to 90% RH, non condensing Nominal 24Vdc, range 18-30V DC 40mA
SENATOR 19” Rack mount Command Module
www.kfp.co.uk
30802-KID
HOME
SENATOR Remote Display Unit (RDU)
CONTENTS
ZOOM
PRINT
EXIT
93
ASPIRATING SMOKE DETECTION
SENATOR REMOTE DISPLAY UNIT RELAY BOARD
SENATOR RDU ENCLOSURE
This is an optional relay board which can be used with the Senator RDU to provide Volt Free Changeover Contacts for signalling to other equipment. Five relays are provided for Fire 1, Fire 2, Pre-alarm, Aux Alarm and Fault (energised).
A low profile 150mm deep, 9U high enclosure with a glazed lockable outer door and space for installing up to 24 RDUs and relay cards. A suitable 24 Vdc power supply is required.
Technical specification Maximum switching voltage Maximum switching current
30803-KID
200 Volts dc 0.5 Amp
Example fitted with 24 RDUs
30824-KID
SENATOR RDU enclosure
30812-KID
Blank In-fill plates for spare slots
30813-KID
In-fill plate with RS232 port for PC interface
SENATOR Remote Display Unit Relay board
SENATOR RDU WALL MOUNTING ENCLOSURE Small steel enclosure for wall mounting a single Senator Remote Display Unit and optional relay board.
SENATOR RDU ENCLOSURE INCLUDING COMMAND MODULE Example fitted with 16 RDUs
A low profile 150mm deep, 9U high enclosure with a glazed lockable outer door containing a Senator Command Module and space for installing up to 16 RDUs and relay cards. A suitable 24 Vdc power supply is required.
Technical specification Dimensions 30817-KID
9494/120 PAGE
80W x 150H x 60D SENATOR RDU wall mounting enclosure
Tel: +44 (0)1844www.kfp.co.uk 265003
30823-KID
SENATOR RDU enclosure including Command Module
30812-KID
Blank In-fill plates for spare slots
30813-KID
In-fill plate with RS232 port for PC interface
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
SENATOR RELAY/INPUT CARD
RDU 19” SUB FRAME
A low profile 3U high sub rack with space for mounting up to 8 RDUs and relay cards. A suitable 24v power supply is required. The Senator Relay/Input card can be fitted into the Senator 25 and 100 detectors to provide an additional five relay outputs for signalling to other equipment. Three inputs are provided on the card that can be programmed for remote reset, isolate, classifire override or PSU fault monitoring.
30436-KID
30814-KID
RDU 19” sub frame
30812-KID
Blank In-fill plates for spare slots
SENATOR Relay/Input card
SENSENET CONTROL UNIT
The SenseNET control unit interfaces the SenseNET detector network with the PC serial port. The control unit comes complete with connecting cables, power supply and PC software. 30804-KID
APIC – APOLLO ADDRESSABLE INTERFACE CARD
SENSENET CONTACT MONITOR
The APIC – Apollo Addressable Interface card can be fitted internally to any Senator detector unit or Command Module and allows connection to the addressable loop of any Apollo protocol control panel. A single APIC may be used in Multi Address mode when installed inside a command module for signalling up to 127 detectors onto the addressable loop reducing costs on larger systems.
30430-KID
PAGE 95/120
SenseNET control unit
APIC – Apollo card
The SenseNET contact monitor allows monitoring of up to 7 clean contacts from other systems through the SenseNET network. Technical specification Maximum input voltage Maximum operating current Operating temperature Operating humidity 30805-KID
www.kfp.co.uk
HOME
18 – 30 Vdc 20mA -10 to +60oC 0 – 90% RH Non condensing
SenseNET Contact monitor
CONTENTS
ZOOM
PRINT
EXIT
95
ASPIRATING SMOKE DETECTION
SENSENET (RS485/RS232 CAT5 CONVERTER)
PS25 INTELLIGENT 2.5 AMP POWER SUPPLY – EN54-4 COMPLIANT
This unit allows the SenseNET network to connect to and send data across a CAT5 Local Area Network (LAN).
The PS25 power supply is designed to provide a versatile solution for powering aspirating smoke detectors. A high capacity 2.5 Amp power supply provides current for ‘day to day’ system operation while charging back-up batteries. The PS25 is capable of providing 24hr mains fail battery back-up using industry standard sealed lead acid batteries. A relay output is provided for remote monitoring of mains fail and battery faults.
30811-KID
SenseNET (RS485/RS232 CAT5 converter
PC INTERFACE This is the interface module only part of the SenseNET control unit, part no. 30804-KID No software or dongle included. 30816-KID
PC interface
Technical specification Enclosure Dimensions Weight Input voltage Max current consumption Operating temperature Operating humidity Output voltage Output current Battery capacity 30826-KID
Steel, neutral colour 383W x 408H x 97D 6Kg 200 to 250V AC 50/60Hz 0.9A @ 200V AC -5 to 40oC 0 to 90% RH 27V dc +/- 1% Maximum 2.5A 2 x 12V 17Ah
PS25 Power Supply
SENATOR BUS ISOLATOR
SENATOR SERIAL CABLE
Provides SenseNET network short circuit isolation for unprotected devices.
For use in conjunction with the Senator remote software. The serial cable provides connection between the Senator detector or command module and a PC.
30754-KID
9696/120 PAGE
30419-KID
Senator bus isolator
Tel: +44 (0)1844www.kfp.co.uk 265003
Senator serial cable
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
SENSENET SOFTWARE CD AND DONGLE
WIRE BURN TEST RIG
Software provides central indication and control for the SenseNET network.
The test rig is used to commission systems designed to meet the requirements of BS6266.
30250-KID Software CD and dongle 30051-KID
Wire burn test rig
SENATOR AIR HEATER BOX For use with Senator detectors, where the sampling points are installed in low temperature applications i.e. cold stores. The heater box warms the air before it reaches the detector unit. Technical specification Enclosure Sheet Steel Heating element Self regulating 230 VAC, 60/200 watts 30422-KID
Senator air heater box
Wire burn test wire
SMOKE PELLETS
This is used in conjunction with the Senator air heater box, part no. 30422-KID and allows monitoring of the heater element. The aspirator with thermostat is designed to replace the existing fan in the Senator 200. A volt free contact on the aspirator can be wired in series with the Senator 200 fault relay.
PAGE 97/120
10 x 0.1mm PVC coated wire (white) supplied on a 100m reel. This is used in conjunction with the wire burn test rig.
21888-K033
ASPIRATOR WITH THERMOSTAT
30425-KID
WIRE BURN TEST WIRE
PH standard smoke pellets ideal for testing large pipework systems to the requirements of BS5839 part-1. Each tube contains 6 x 13g pellets with a 40 sec burn time. 21888-K030
Aspirator with thermastat
www.kfp.co.uk
HOME
Smoke pellets
CONTENTS
ZOOM
PRINT
EXIT
97
ASPIRATING SMOKE DETECTION
HART High Sensitivity Smoke Detection
The HART High Sensitivity Smoke Detection (HSSD) system is optimised in terms of performance, capability, reliability and serviceability. Featuring simplicity in both system configuration and operation, HART has a clean, aesthetic design and is compact and lightweight. HART Mini Designed to provide area coverage up to 800m2. Top and bottom pipe entry options are available, and a single LED provides status indication. HART XL Designed to provide area coverage up to 2000m2, HART XL offers complete flexibility – just four sub units provide all the configuration options.
HART XL with optional display module and power supply
9898/120 PAGE
Individual particle counting HART HSSD operates on a laser-based particle counting principle. The smoke particles pass through a focussed laser beam with scattered light from individual particles being picked up by a photodiode sensor and converted to an electrical pulse. The pulse rate is electronically counted and measured against alert and alarm thresholds. Information regarding smoke levels and alarm thresholds can be presented on a Hart XL LCD. Alarm and fault signals can easily be transmitted to a Fire Alarm control panel or BMS through volt free relays. Since the sensing process takes place in the beam in the centre of the sampling chamber, the detection performance is unaffected by any build up of particulate on the walls of the chamber over time. For this reason air filtering is unnecessary, which is an important maintenance benefit.
Tel: +44 (0)1844www.kfp.co.uk 265003
E-mail:
[email protected] CONTENTS HOME
Features • Laser based particle counting • Elegant, compact, lightweight design • No particle filters required for electronic data processing applications • No recalibration during lifetime of detector • Complete flexibility – four basic sub units provide installation options • On site sensitivity selection 0.0025%/m to 1%/m • LaserNet networking options • Modular design for fast and easy servicing • Configurable for integral or remote display options • Attachable power supply and battery back up unit • Individual pre-alarm and alarm levels • Optical Self-Test (OST) which positively checks the condition of the detector • Range of worldwide product approvals
Benefits • High immunity smoke discrimination • Simple, low-cost maintenance • High reliability • High immunity to unwanted alarms • Long term stability • No recalibration required
Web:ZOOM www.kfp.co.uk PRINT
EXIT
HART MINI DETECTOR
HART XL DETECTOR
The HART mini High Sensitivity Smoke Detector provides cost effective, very early warning smoke detection in small areas up to 800m2. Single tri-colour LED provides indication of the detector status. Single pushbutton provides isolation and reset controls. The HART mini is supplied in two variants for top or bottom pipe entry to suit the installation. Volt free change over relays provide the facility to interface the HART mini into the site fire alarm system. Programmable options such as alarm levels and delays, latching or non-latching alarms, airflow normalisation, high and low airflow levels and automatic sensitivity setup are available when using a PC and the LaserNET programming software.
The HART XL High Sensitivity Smoke Detector provides very early warning smoke detection in areas up to 2000m2 in area. Single tri-colour LED provides indication of the detector status, no user controls are provided in the HART XL detector although an optional display module is available. Volt free change over relays provide the facility to interface the HART XL into the site fire alarm system. Programmable options such as alarm levels and delays, latching or nonlatching alarms, airflow normalisation, high and low airflow levels and automatic sensitivity setup are available when using a PC and the LaserNET programming software. The HART XL can be mounted either way up allowing top or bottom pipe entry and is provided with the necessary adaptors for fixing an exhaust pipe.
Technical specification
Technical specification
Enclosure Dimensions Weight Enclosure rating Operating temperature Operating humidity Voltage requirements Quiescent current Alarm current Indications Controls Relay outputs Inputs Sensitivity range Air inlet
Light grey polycarbonate with steel mounting plate 222W x 226H x 81D 2.2Kg IP31 (NEMA-1) 0 to 49oC 10 to 93% RH, non condensing at 40oC 18 to 30V dc (24V dc nominal) 230mA 246mA Tri-colour LED – Alarm, Pre-alarm, Fault, Isolated Push button – Reset, Isolate 3 x 2A @30V dc – Pre-alarm, Alarm, Fault (energised) Remote reset, RS485 network 0.0025 to 1.0% obscuration per metre ¾” threaded NPT (3/4” to 25mm adaptor supplied)
53836-K205K-00
HART Mini - bottom pipe entry
53836-K205K-01
HART Mini - top pipe entry
PAGE 99/120
Enclosure Dimensions Weight Enclosure rating Operating temperature Operating humidity Voltage requirements Quiescent current Alarm current Indications Controls Relay outputs Inputs Sensitivity range Air inlet Air exhaust
Light grey polycarbonate with steel mounting plate 320W x 228H x 108D 3.4Kg IP31 (NEMA-1) 0 to 52oC 10 to 93% RH, non condensing at 40oC 18 to 30V dc (24V DC nominal) 315mA 380mA Tri-colour LED – Alarm, Pre-alarm, Fault, Isolated, Optional Display Module Optional Display Module 6 x 2A @30V dc – Pre-alarm 1, Pre-alarm 2, Alarm 1, Alarm 2, Isolate, Fault (energised) RS485 network 0.0025 to 1.0% obscuration per metre ¾” threaded NPT (3/4” to 25mm adaptor supplied) 1” threaded NPT (1” to 25mm adaptor supplied)
53836-K183 HART XL detector
www.kfp.co.uk
HOME
CONTENTS
ZOOM
PRINT
EXIT
99
ASPIRATING SMOKE DETECTION
HART XL DISPLAY MODULE
HART XL SELF CONTAINED POWER SUPPLY
PS25 INTELLIGENT 2.5 AMP POWER SUPPLY
The HART XL Display module provides the display of status information and functional controls for the HART XL detector. The Display Module can be mounted within the detector unit or remotely up to 1km away. Clear information regarding the detector status and settings are provided on the Large LCD. Pushbutton controls are provided for basic operations with password restricted access. Language variants are available.
The HART XL self contained power supply can power a single detector, with or without a display. The PSU housing can fit 2 x 12v 2.0Ah batteries (Yuasa NP2-12) which will provide up to 4hrs standby power.
The PS25 power supply is designed to provide a versatile solution for powering aspirating smoke detectors. A high capacity 2.5 Amp power supply provides current for ‘day to day’ system operation while charging back-up batteries. The PS25 is capable of providing 24hr mains fail battery back-up using industry standard sealed lead acid batteries. A relay output is provided for remote monitoring of mains fail and battery faults
Technical specification
Technical specification
Technical specification
Enclosure Dimensions Weight Enclosure rating Operating temperature Operating humidity Voltage requirements Quiescent current Indications Controls Communications
Light grey polycarbonate with steel mounting plate 122W x 145H x 38D 0.5Kg IP31 (NEMA-1) 0 to 52oC 10 to 95% RH, non condensing at 40oC 18-36V dc - supplied from detector unit 30mA normal (100mA with backlight on) Large LCD Tri-colour LED – Alarm, Pre-alarm, Fault, Isolated 4 x Cursor keys, 1 x Enter key RS485
Enclosure Dimensions Weight Input voltage Max input current Operating temperature Operating humidity Output voltage Output current Fault relay Battery capacity
EN54-4 APPROVED
Light grey polycarbonate with steel backbox 317W x 114H x 105D 3.1Kg 90 to 260 V AC 50/60Hz 1A 0 to 52oC with no de-rating 10 to 95% RH, non condensing 28.75V dc Maximum 1A Normally closed contact 1 Amp @ 28V dc 2 x 12V 2.0Ah (Yuasa NP2-12)
Enclosure Dimensions Weight Input voltage Max current consumption Operating temperature Operating humidity Output voltage Output current Battery capacity
Steel, neutral colour 383W x 408H x 97D 6Kg 200 to 250V AC 50/60Hz 0.9A @ 200V AC -5 to 40oC 0 to 90% RH 27V dc +/- 1% Maximum 2.5A 2 x 12V 17Ah
53836-K185 HART XL Self Contained Power Supply 53836-K182
PAGE100 100/120
HART XL Display Module
Tel: +44 (0)1844www.kfp.co.uk 265003
23911-K051 12V 2.0AH Battery (2 required)
E-mail:
[email protected] CONTENTS HOME
30826-KID PS25 Power Supply
Web:ZOOM www.kfp.co.uk PRINT
EXIT
HART REMOTE INTERFACE CARD
HART XL APOLLO INTERFACE CARD
LASERNET PROGRAMMING SOFTWARE
The Remote interface card provides the facility to monitor and control the operation of the HART XL detector without the use of LaserNET programming software or Display Module. A monitored input allows the monitoring of external Reset, Silence and Isolate switches. The Remote interface plugs directly into the termination board within the HART XL detector
The HART XL Apollo interface card can be installed within the HART XL detector enabling it to interface to any Apollo protocol control panel providing Pre-alarm, Alarm and Fault levels. When interfaced to the Kidde Vega control panel additional monitoring functions are available.
All HART HSSD detectors are programmed using LaserNet software and the HART programming lead. Each HART Detector is shipped with a CD containing this software but the programming lead must be purchased separately. The software enables the user to monitor interrogate, configure and download system data.
Technical specification
Technical specification
Inputs Outputs
Quiescent current Max current Operating temperature Operating humidity
Monitored input 4-20mA output for smoke and airflow signals 0-12mA output for smoke and airflow signals Airflow fault relay – 2A @ 30V dc 50mA 90mA 0 to 52oC 10 to 95% RH, non condensing at 40oC
Connections Address Loop current Indications Operating temperature Operating humidity
Loop in +ve/-ve, Loop out +ve/-ve 8 way DIL switch 2mA Power on LED Loop comms OK LED 0 to 52oC 10 to 95% RH, non condensing at 40oC
36215-K228 HART CD 44782-K165 HART XL Remote Interface Card
PAGE101/120
44782-K167
www.kfp.co.uk
HART XL Apollo Interface Card
HOME
53800-H08
CONTENTS
ZOOM
HART Programming Lead
PRINT
EXIT
101
ASPIRATING SMOKE DETECTION
ASD detector range: potential market sectors Senator 25 Prison Cells Heritage Buildings Retail Outlet Ceiling Voids Atrium (10m) Atrium (10m+)
● ● ● ● ● ●
Telephone Exchange EDP Room Clean Room Small Comms Room Plant Room
● ● ● ●
Cabinets Trains Wind Generators
● ● ●
Cold Stores Wash Down Areas Factory WareHouse Under Mezzanine Area
● ● ●
Explosion Risk (Gas)
●
ASD Detector Range
Senator 100
●
Senator 200
Senator Ex
Hart XL ● ● ●
●
Hart Mini ● ●
Pipe Length (total) Qty Pipes
Senator 25
Senator 100
Senator 200
Senator Ex
50m
100m
250m
50m
1
2
4
1
10 10 10 0.03%-25%
20 20 20 0.03%-25%
20 40 100 0.03%-25%
10 10 10 0.03%-25%l
●
Hart XL
●
●
●
●
● ● ● ●
● ● ●
● ● ●
●
Qty Holes: Class A Qty Holes: Class B Qty Holes: Class C Sensitivity: obsc/m
● ●
RS485 Comms Addressable interface Card
● ❉
● ❉
● ❉
● ❉
● ❉
● ●
● ● ●
Firmware Upgradeable Configure with PC Configure without PC
●
●
● ❉
●
● ●
● ●
● ● ● ● ●
● ● ●
Fix ClassiFire ClassiFire Override Remote Reset
❉ ❉
❉ ❉
● ●
❉ ❉
❉
●
Outputs: Fire1 Outputs: Fire2 Outputs: Prelarm Outputs: Aux Outputs: Fault
● ❉ ❉ ❉ ●
● ❉ ❉ ❉ ●
● ● ● ● ●
● ❉ ❉ ❉ ●
● ● ● ● ●
●
● ● ● ● ●
● ● ● ● ● ●
●
❉ via optional card
PAGE102 102/120
Hart Mini
2x100 or 4x50m 80m (2x50m capable) 1+multiple 1+2 branches branches 40 40 40 40 100 100 0.025%-1% 0.025%-1%
Tel: +44 (0)1844www.kfp.co.uk 265003
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
● ● ●
AIR SAMPLING PIPE 25mm O.D. 3 METRE LENGTH
SnifferPipe SnifferPipe is a comprehensive range of high quality pipe, fittings and accessories for the Senator and HART aspirating smoke detection systems. SnifferPipe and fittings are manufactured from red Acrylonitrile Butadiene Styrene (ABS). The physical properties of ABS make the pipe and fittings ideal for aspirating pipework systems: • • • • •
21888-K016
EQUAL TEE
Air sampling pipe 25mm O.D. 3 metre length
STRAIGHT SOCKET
Robust construction to reduce mechanical damage Smooth bore to facilitate air flow to the detector Lightweight and easy to install High resistance to chemicals and weathering Suitable for use over a wide temperature range. - 40 to +80° C
The red colour and clear markings ensure the air sampling pipe network is easily identifiable from other services.
21888-K020
Equal Tee
END CAP
Straight Socket
21888-K021
90° ELBOW
21888-K017
21888-K018
End Cap
UNION SOCKET
90° Elbow
21888-K024
Union Socket
The SnifferPipe range is based on pipework with standard metric outside diameter of 25mm.
45° ELBOW
21888-K018
PAGE 103/120
www.kfp.co.uk
PIPE CLIP
45° Elbow
21888-K025
HOME
CONTENTS
ZOOM
Pipe Clip
PRINT
EXIT
103
ASPIRATING SMOKE DETECTION
PARTICLE SEPARATOR
FLUSH AIR SAMPLING POINT CAPILLARY KIT
The particle separator can assist with keeping the detector clean when installed in dirty and dusty environments. The unit is supplied with two 25mm union sockets to allow installation into the sampling pipe. Foam elements inside the detector can easily be replaced as necessary. 21888-K063
Particle Separator
21888-K064
Replacement Foam Elements for Particle Separator
21888-K066
The conical air sampling point capillary kit can be used where discrete detection is required. The capillary kit can be connected to sampling pipe which is installed in a ceiling void out of view with the conical sample point fixed through the ceiling to sample from the protected area. The capillary tube is supplied 2m in length but can be cut accordingly on site. A 25mm compression adaptor allows it to be used with standard pipework fittings i.e. Elbow, Equal Tee, or Socket.
PAGE104 104/120
Flush Air Sampling Point Capillary Kit
DISCRETE 10mm CAPILLARY SAMPLING POINT
CONICAL AIR SAMPLING POINT CAPILLARY KIT
21888-K065
The flush air sampling point capillary kit can be used where discrete detection is required. The capillary kit can be connected to sampling pipe which is installed in a ceiling void out of view with the flush sample point fixed through the ceiling to sample from the protected area. The capillary tube is supplied 2m in length but can be cut accordingly on site. A 25mm compression adaptor allows it to be used with standard pipework fittings i.e. Elbow, Equal Tee, or Socket
The discrete 10mm capillary sampling point can be used where discrete detection is required. The capillary sample point will fit on the end of the nylon capillary tube and can then be drilled with the correct sample hole size.
Conical Air Sampling Point Capillary Kit
Tel: +44 (0)1844www.kfp.co.uk 265003
SAMPLING TEST POINT The sampling test point can be used where access to the sampling points for testing is difficult or restricted. The test point can be installed at an accessible location to allow easy smoke testing of the system during its service. 21888-K067
Sampling test point
10mm NYLON CAPILLARY TUBE Provided in a 30 metre reel the nylon capillary tube allows customers to create their own capillary sample kits, where existing kits aren’t suitable. Colour: Natural 21888-K062
10mm Nylon Capillary tube
25mm/10mm COMPRESSION ADAPTOR The compression adaptor allows 10mm capillary tube to be connected into standard 25mm fittings i.e. Elbow, Equal Tee and Sockets.
21888-K068
Discrete 10mm Capillary Sampling Point
E-mail:
[email protected] CONTENTS HOME
TBA
25mm/10mm Compression adaptor
Web:ZOOM www.kfp.co.uk PRINT
EXIT
PIPE CUTTERS Ratchet action cutters for plastic pipe, can cut pipe up to 42mm in diameter.
21888-K028
Pipe Cutters
PIPE WARNING LABEL The pipe warning label is used to identify pipework as aspirating pipework to prevent damage to the system, supplied as a 100 label roll.
39155-H11
Pipe warning label
PIPE SAMPLING POINT LABEL The pipe sampling point label is used to identify the location of sampling points drilled into the sampling pipework.
36215-K326
PAGE 105/120
Pipe sampling point label
www.kfp.co.uk
HOME
CONTENTS
ZOOM
PRINT
EXIT
105
ALARMLINE LINEAR HEAT DETECTION
PAGE106 106/120
Tel: +44 (0)1844www.kfp.co.uk 265003
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
Kidde Linear Heat Detection (LHD) Systems are cable based systems that provide economical temperature monitoring at the precise point of risk. The system is reliable, flexible and has the ability to detect abnormal temperature variances before it develops into a fire situation. Kidde Fire Protection’s comprehensive LHD portfolio allows a vast range of both commercial and industrial fire and overheat risks to be protected, in ambient temperatures of – 40°C to + 200°C. Alarmline sensor cables may be installed within hazardous environments using approved I.S. barriers for simple apparatus. All Alarmline cables supplied in increments of 100m up to 1000m. Benefits • • • • •
PAGE 107/120
www.kfp.co.uk
Detection at point of risk. Continuous operation within the most adverse environmental conditions. Electrical and mechanical flexibility. Internationally proven “in service” experience. Integration with all types of central control systems.
HOME
CONTENTS
ZOOM
PRINT
EXIT
107
ALARMLINE LINEAR HEAT DETECTION
Where to use Alarmline Linear Heat Detection PAGE108 108/120
Tel: +44 (0)1844www.kfp.co.uk 265003
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
Cable Tunnels
Floating Roof Tanks
Conveyors
High power cable installations at power stations, airport terminals, railway stations and any installations requiring substantial power requirements can be protected by Alarmline sensor cables. Alarmline cable is suitable for use in harsh environments.
The petrochemical industry requires that tank fires caused by the ignition of combustible gases are extinguished in a short time frame. A rim seal Alarmline detection system provides a fast extinguishant response.
Overheating bearings on conveyor support rollers can be a common cause of conveyor belt fires. Alarmline systems can detect these overheat conditions. Additional protection can be provided above and below the conveyor belt against spillage and the transportation of ignited material.
Bulk Storage
Car Parks
Escalators
Alarmline “In rack“ protection at multiple levels ensures rapid fire detection. As part of a pre action sprinkler system, an advance warning of imminent sprinkler operation may avoid unnecessary water damage to stored goods.
The combustible materials used in the manufacture of modern passenger vehicles results in fires that burn more intensely and generate higher temperatures than ever before. That’s why early detection of fire conditions is essential in enclosed over and underground car parks. Alarmline installed at the ceiling achieves this by detecting significant rises in temperature not just at localised “hot spots” but over the entire length of cable.
Alarmline system provides for the total protection of escalators with coverage provided at all potential fire risk areas i.e. drive motors , return roller bearings dust collection trays and truss rollers. Alarmline can be used to give fire alarm indication and also to initiate a sprinkler system.
PAGE 109/120
www.kfp.co.uk
HOME
CONTENTS
ZOOM
PRINT
EXIT
109
ALARMLINE LINEAR HEAT DETECTION
ALARMLINE LHD4 CONTROLLER
ALARMLINE Analogue Alarmline Analogue cable senses temperature variations by continuously monitoring the resistance of the specially doped Negative Temperature Coefficient (NTC) polymeric insulation. A change in temperature produces a relative change in resistance which is monitored by a dedicated Alarmline controller. Suitable for Hazardous Area applications when used with approved Zener Barriers.
This unit is used to monitor alarmline analogue cable and actuate an alarm signal at a pre determined level. The integrating effect of Alarmline sensor cable enables it to detect either a hot spot or a lower level of temperature increase along its total length. Technical specification Enclosure Supply Voltage Quiescent Current Consumption Fire Alarm Current Consumption Fault Alarm Current Consumption Maximum length of detection cable
Series 4LHD with Fire and Fault Relays Quiescent Current Consumption 20 mA Fire Alarm Current Consumption 85 mA Fault Alarm Current Consumption 16 mA Indicators Fire Alarm Fault Alarm Operating Temperature Range
PAGE110 110/120
Tel: +44 (0)1844www.kfp.co.uk 265003
Polycarbonate, IP 54 rated, 130W X 178H X 99 D Colour RAL 7035, Weight 0.81Kg 8 to 30 Vdc 60 to 180 µA depending on alarm trip setting 15 to 70 mA preset by means of internal resistor 180 µA maximum 1000m
Front panel mounted continuous Red Front panel mounted flashing yellow LED -25°C to + 52°C
53836-K254
LHD4 Controller, conventional zone 2 wire connection
53836-K255
LHD4 Controller, fire and fault relay outputs (fault relay energised)
53836-K257
LHD4 fire and fault relay outputs (fault relay de-energised)
53836-K253
LHD4 Controller, conventional zone 2 wire connection (non CE)
53836-K256
LHD4 Controller, fire and fault relay outputs (fault relay energised) (No CE) FM approved
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
LWM1 ALARMLINE CONTROLLER (EN54 Pt5 approved)
ALARMLINE ANALOGUE CABLE (FM APPROVED)
The LWM1 controller monitors alarmline analogue sensor cable combining both fixed temperature (Max–alarm) and rate of rise temperature (Diff-alarm) detection.
Recommended for environments ranging from clean and dry to moderate dust and moisture. Not for external use or for installations where corrosive agents or damage to cable may occur.
The control unit reports temperature differences by the permanent supervision of the resistance of the sensor cable. The Max – alarm is triggered if the adjustable static alarm temperature of the sensor cable is reached or exceeded. The rate of rise alarm (Dif-alarm) is triggered by the adjustable integration of time and temperature change.
Ext. Dia. Weight
3.25mm 3.2 Kg (200m)
Typical installations Cable Trays Ceiling and Floor Voids
Electrical Switch Gear
Service Ducts
Tunnels
Technical specification Enclosure
Supply Voltage Quiescent Current Consumption Diff-alarm or Max-Alarm Current Consumption Fault alarm Current Consumption Operating Temperature Range
ABS IP 65 rated 200W x 120H x 80D Colour RAL 7035 Weight 0.55Kg 10 to 30 Vdc 25 mA 25 mA 15 mA -20°C to + 50°C
Approved to EN54 PART 5 when used with cable part numbers K82017, K82021 and K98166 (max 300m).
K82017
Alarmline, blue PVC outer sheath
ALARMLINE ANALOGUE CABLE (FM APPROVED) Recommended for hostile environments, Petrochemical, Cold Storage, and general external use. Can also be used in areas where more rigidity or discreet installations are required. Ext. Dia. Weight
4.25mm 4.3 Kg (200m)
Typical installations Floating Roof Tanks Cold Stores Car Parks Areas subject to chemical contamination. 53836-K248
PAGE 111/120
LWM1 Alarmline controller
K82021
www.kfp.co.uk
HOME
Paint Spray Booths
Silos and Driers
Alarmline black nylon outer sheath
CONTENTS
ZOOM
PRINT
EXIT
111
ALARMLINE LINEAR HEAT DETECTION
ALARMLINE ANALOGUE CABLE (FM APPROVED)
ALARMLINE Digital Cable
Recommended for areas which have a high risk of friction or mechanical damage. Ext. Dia. Weight
4.25mm 8.3 Kg (200m)
Typical installations Conveyors Travelators
Escalators
(ALL FM APPROVED) Elevators
Thatched Roofs
Alarmline Digital is a twin conductor switching cable with temperature sensitive insulation, protected by a special braid, PVC or high temperature, chemical resistant polymer outer sheath to meet specific application requirements. Alarmline Digital cable operates by melting of the internal insulation between the conductors, at a predetermined temperature. This results in a short circuit which provides a fire alarm signal. Fire and fault conditions are provided by continuously monitoring for a short circuit (Fire) or open circuit (Fault) state by the fire alarm panel.
K82078 Alarmline PVC and Bronze Braided outer sheath
ALARMLINE ANALOGUE CABLE (FM APPROVED)
Suitable for Hazardous Area applications when used with approved Zener Barriers or Galvanic Isolators. Recommended for areas where a high level of chemical and mechanical damage is likely. Ext. Dia. Weight
5.5mm 10 Kg (200m)
Typical installations Mines
Conductors Max conductor resistance Voltage rating Pulling force Bend radius
Tinned copper-covered steel 100 ohms per km at 20°C 110 Vdc 50N max 50mm minimum
Offshore Installations
K98166
PAGE112 112/120
Alarmline Nylon, Stainless Steel Braided Sensor
Tel: +44 (0)1844www.kfp.co.uk 265003
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
63-70°C ALARM (67°C NOMINAL)
79-95°C ALARM (67°C NOMINAL)
CABLE TYPE H8040 MAX AMBIENT TEMPERATURE 45°C Min operating temperature Diameter Weight
CABLE TYPE H8040N MAX AMBIENT TEMPERATURE 45°C
-40°C 3.7mm 16.8 Kg/Km
Min operating temperature Diameter Weight
Polythene braid outer covering red/green identification, suitable for internal use. In areas where corrosive agents are not present.
63-70°C ALARM (67°C NOMINAL)
101-108°C ALARM (105°C NOMINAL)
CABLE TYPE H8040N MAX AMBIENT TEMPERATURE 45°C
CABLE TYPE H8028 MAX AMBIENT TEMPERATURE 70°C
-40°C 3.35mm 15.85 Kg/Km
Min operating temperature Diameter Weight
Nylon outer sheath, suitable for external use or in areas where corrosive agents could be present. D5387-368
Black PVC covering suitable for internal and external applications. Excluding areas contaminated by chemical agents which could affect the PVC outer sheath.
177-189°C ALARM (183°C NOMINAL)
CABLE TYPE H8045 MAX AMBIENT TEMPERATURE 45°C
CABLE TYPE H8069 MAX AMBIENT TEMPERATURE 105°C
-40°C 3.1mm 16.8 Kg/Km
Min operating temperature Diameter Weight
Polythene braid outer sheath, red/black identification, suitable for internal use in areas where corrosive agents are not present. D5387-085
PAGE 113/120
-30°C 4.25mm 22.7 Kg/Km
D5387-105
79-95°C ALARM (67°C NOMINAL)
Min operating temperature Diameter Weight
Nylon outer sheath, suitable for external use and in areas where corrosive agents could be present. D5387-385
D5387-068
Min operating temperature Diameter Weight
-40°C 3.35mm 15.85 Kg/Km
-40°C 4.35mm 18.85 Kg/Km
Red PVC covering suitable for internal and external applications. Not suitable for areas with long exposure to direct sunlight. D5387-174
www.kfp.co.uk
HOME
CONTENTS
ZOOM
PRINT
EXIT
113
ALARMLINE LINEAR HEAT DETECTION
229-251°C ALARM (240°C NOMINAL)
EDGE CLIP
CABLE TYPE H9650 MAX AMBIENT TEMPERATURE 200°C
Min operating temperature Diameter Weight
-50°C 3.5mm 21.8 Kg/Km
Edge clips are used as a quick and easy way to install Alarmline cable, used on girders, steel sections, floating roof storage tank rim seals and foam dams, etc. Clips are generally installed at 1 metre spacing.
Fluropolymer covering suitable for external applications where high ambient temperatures are expected or where protection against chemical agents is required. Suitable for use in direct sunlight.
Material:
Heat treated spring steel with a multi layer zinc phosphate coating
B6782-003 Suitable for steel thickness 2–3mm B6782-024 Suitable for steel thickness 3–8mm
D5387-227
B6782-025 Suitable for steel thickness 8–14mm B6782-026 Suitable for steel thickness 14–20mm B6782-195 Suitable for steel thickness 3-8mm Stainless Steel version
ALARMLINE Fixing Accessories
Also shown in picture B6782-008 Neoprene Sleeve B6782-121 Cable Tie
Kidde offer a wide range of mounting accessories to enable ease of installation for Alarmline Analogue and Alarmline digital cables. The fixings available allow the Alarmline cables to be attached to walls, cable trays, girders, pipework etc. to suit the majority of applications.
PAGE114 114/120
Tel: +44 (0)1844www.kfp.co.uk 265003
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
NEOPRENE SLEEVE
T CLIP
40 mm split sleeve is used to protect Alarmline cables from being crushed or damaged when attached to fixing clips.The sleeve also acts as an insulator to prevent the transfer of heat through metal fixing clips. Fire resistant.
“T” Clip is used to fix all Alarmline cables (except K98166 Stainless Steel) to surfaces that are suitable for drilling i.e. wood and concrete. Recommended spacing 1 per metre.
B6782-008 Neoprene sleeve
Material:
CABLE TIE
Plastic
Upper Temperature Limit + 85°C Lower Temperature Limit - 50°C Material Degrades at + 120°C
B6782-004 T clip Also shown in picture
U.V. Stabilised cable tie 100mm long x 2.5 mm wide. Used to secure Alarmline cable to fixing clips where necessary.
B6782-121 Cable tie
B6782-121 Cable tie
V CLIP
PIPE CLIP Stainless Steel 304 Pipe clip is universal and will fit any diameter pipe (pipe strapping or cable tie required) Recommended spacing 1 per metre. B6782-005 Pipe clip
“V” Clip specifically designed to fit Admiralty standard cable tray at 1 metre spacing. Material: Spring Steel with spray coated finish. Clip comes complete with protective neoprene pad. Recommended spacing 1 per metre.
Also shown in picture B6782-008 Neoprene sleeve
B6782-023 V clip
B6782-121 Cable tie
B6782-121 Cable tie (Required if V clip is inverted)
PAGE 115/120
www.kfp.co.uk
HOME
CONTENTS
ZOOM
PRINT
EXIT
115
ALARMLINE LINEAR HEAT DETECTION
L BRACKET C/W STRAIN RELIEF BUSH
CHANNEL BRACKET Channel Bracket is designed to secure Alarmline cable onto horizontal metal surfaces where there is no return edge available to fix a bracket or clip. Mainly used on fixed Roof Storage Tanks. It is secured using a two part chemical anchoring system.
“L” Bracket designed to support Alarmline cable above risk area i.e. Top run of cable tray. Recommended spacing 1 per metre. Material Dimensions
Material
Stainless Steel 304 150 mm x 20 mm x 20 mm
Stainless Steel 304
B6782-142 Channel bracket Also shown in picture
B6782-154 L bracket c/w strain relief bush
B6782-008 Neoprene sleeve B6782-121 Cable tie
DISTANCE PIECE
CHANNEL BRACKET CHEMICAL ANCHORING SYSTEM
Distance Piece can be used with edge brackets to extend the positioning of Alarmline cable. Spacing 1 per metre.
Used for fixing Channel Brackets to Fixed Roof Tanks
Material Dimensions
380ml Cartridge containing two part chemical anchoring system, based on a polyester resin. Each cartridge is suitable for 25 applications in single continuous operation. Each cartridge is supplied with one self mixing nozzle. Additional nozzles are available.
Mild Steel Zinc Plated 200 mm x 20mm
This product has a 12 month shelf life. COSHH statement is available.
B6782-120 Distance piece Also shown in picture
B6782-144 Heavy Duty Applicator Gun
B6782-008 Neoprene Sleeve
A6782-201 Combined Resin and Hardener
B6782-121 Cable tie
B6782-143 Replacement Nozzle
PAGE116 116/120
Tel: +44 (0)1844www.kfp.co.uk 265003
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
L BRACKET
RETRACTABLE CABLES
“L” Bracket designed to fit with edge clip around floating roof storage tanks. The brackets are fixed to the foam dam using an edge clip. Spacing 1 per metre Used where the foam dam plate is vertical or has a 90 degree return edge.
Retractable cables are designed to provide electrical connection from tank roof to tank top on floating roof tanks, reducing the risk of cable being caught and snapped during the normal rising and falling movement of the tank roof.
Material
Number of cores Core Colours Core Size Core Insulation
Stainless Steel 304
B6782-194 L bracket
(Used with Cable Collector B6782-032)
Also shown in picture
Inner Sheath Outer Sheath Cable OD Coil OD Tails
Polyurethane Hytrel 10 mm 230 mm Nom. 1500 mm & 5000 mm
B6782-036 Retractable cable 10m
B6782-008 Neoprene Sleeve
B6782-037 Retractable cable 11m
B6782-121 Cable tie B6782-XXX 35100-K254 35100-K253 21176-K007
4 1 Blue 2 Brown 3 Black 4 Yellow 0.75 mm 2 Hytrel
Edge clip (xxx – denotes web thickness) M6 x 15mm Hex Bolt Stainless Steel M6 Full Nut Stainless Steel M6 Flat Washer Stainless Steel
B6782-038 Retractable cable 12m B6782-039 Retractable cable 13m B6782-040 Retractable cable 14m B6782-030 Retractable cable 15m B6782-041 Retractable cable 16m B6782-042 Retractable cable 17m B6782-043 Retractable cable 18m B6782-044 Retractable cable 19m B6782-045 Retractable cable 20m B6782-046 Retractable cable 21m B6782-047 Retractable cable 22m B6782-048 Retractable cable 23m B6782-049 Retractable cable 24m B6782-050 Retractable cable 25m B6782-170 Retractable cable 30m
PAGE 117/120
www.kfp.co.uk
HOME
CONTENTS
ZOOM
PRINT
EXIT
117
ALARMLINE LINEAR HEAT DETECTION
CABLE COLLECTOR
AUTOMATIC CABLE REELER
Designed to be fixed to a floating roof for collecting the retractable cables. The cable collector rises and falls with the movement of the roof, uncoiling the cable when the roof lowers, and collecting the cable when the roof rises. The collector is supplied with drainage holes.
The Kidde Automatic Reeler is an alternative system to using the retractable cable and cable collector. It is installed on the top rim of the tank body. The cable is connected to a junction box (part number B6782-190) located on the tank roof. The automatic cable reeler follows the movement of the roof, uncoiling the cable as the roof lowers, and winding the cable in when the roof rises. Maximum drop 25 metres
Material:
Stainless Steel 304
If the area that the equipment is installed in is classed as Hazardous, electrical connection must be via suitable safety barriers.
B6782-032 Cable collector B6782-000 Retractable Cable (select cable length) B6782-189 FLP Junction Box for Tank Top B6782-190 FLP Junction Box for Tank Roof
Materials: Box: Stainless steel 304 Internal spring: Carbon steel Internal devices: ABS/ Fibre glass
Cable: 4 conductors 1mm Flame retardant External coating: Santoprene Resistant to chemical agents Operating temperature: -40 to + 70°C Resistance: 19.5 ohm /km 2 Capacitance spec: 80nF/km Inductance spec: 0.9mH/km Insulation resistance: 100 Mohm/km
53836-K241 Automatic Cable Reeler with EX Polycarbonate Junction Box EX 112G EExe 11 PTB 01 ATEX 1014u 53836-K247 Automatic Cable Reeler with EX Stainless Steel Junction Box
PAGE118 118/120
Tel: +44 (0)1844www.kfp.co.uk 265003
E-mail:
[email protected] CONTENTS HOME
Web:ZOOM www.kfp.co.uk PRINT
EXIT
JUNCTION BOX TANK TOP
JUNCTION BOX TANK ROOF
EExe junction box to be mounted at the top of the floating roof storage tank. Allows electrical connection from site cabling to retractable cable.
EExe junction box to be mounted on the roof of the floating roof storage tank. Allows electrical connection between retractable cable and Alarmline detection cable..
Technical Data. • Increased safety EExe • Suitable for use in Zone 1, Zone 2, Zone 21 and Zone 22 • Ingress protection to IP66 • Size: 120W x 120H x 73.5D • 4 x 7mm dia fixing holes at 102mm sq CRS • Weight: 0.8kg • Operating temperature range: -60°c to +75°c • Temperature class and ambient: T6 40°c • Material: GRP, Natural black finish • Flame Retardant to IEC 92.1 Clause 2.38 • Supplied with Steel Earth Continuity Plate • Terminals 6 x 2.5mm. 1 x Earth 4mm • Cable glands Ex d IP66 1 x M25 Brass 1 x M20 Brass
Technical Data. • Increased safety EExe • Suitable for use in Zone 1, Zone 2, Zone 21 and Zone 22 • Ingress protection to IP66 • Size: 120W x 120H x 73.5D • 4 x 7mm dia fixing holes at 102mm sq CRS • Weight: 0.8kg • Operating temperature range: -60°c to +75°c • Temperature class and ambient: T6 40°c • Material: GRP, Natural black finish • Flame Retardant to IEC 92.1 Clause 2.38 • Terminals 4 x 2.5mm. 1 x Earth 4mm • Cable glands Ex d IP66 3 x M20 Brass
B6782-189 Junction Box Tank top
PAGE 119/120
B6782-190 Junction Box Tank Roof
www.kfp.co.uk
HOME
CONTENTS
ZOOM
PRINT
EXIT
119
Kidde Fire Protection Thame Park Road Thame Oxfordshire OX9 3RT United Kingdom
EUROPE
Tel: Fax: Email: Web:
Tel: Fax: Email: Web:
Kidde Denmark Industriholmen 17-19 DK-2650 Hvidovre DENMARK
+44 1844 265 003 +44 1844 265 156
[email protected] www.kfp.co.uk
+45 36 86 9600 +45 36 86 9611
[email protected] www.ginge-kerr.dk
Kidde Eesti A/S Laki 11B Tallinn ESTONIA Tel: Fax: Email: Web:
+372 651 7010 +372 651 7011
[email protected] www.kidde.ee
Kidde Finland Box 46 Tiilenpolttajankuja 6 SF 01720 Vantaa FINLAND Tel : Fax : Email : Web :
UFS Russia and CIS Lyusinovskaya str.36 Bld 1, 10 floor 115093 Moscow RUSSIA Tel: Fax: Email:
+7 495 937 1891 +7 495 937 1890
[email protected]
Kidde Australia Pty Ltd 314 Boundary Road Dingley, VIC 3172 AUSTRALIA
Kidde Resmat Parsch Rua Parsch 755 Distrito Industrial – 132800-000 Vinhedo-SP BRASIL
Tel: Fax: Email: Web:
+61 (3) 9518 5588 +61 (3) 9518 5577
[email protected] www.kidde.com.au
Shanghai Kidde Fire Protection Trading Co Ltd C, 2/F Sun Tong Infoport Plaza 55 Hau Hai Road (West) Shanghai 200030 CHINA
Tel: Fax: Email: Web:
Tel: Fax: Email: Web:
+46 08 615 9900 +46 08 615 9999
[email protected] www.kidde.se
Tel: Fax: Email: Web:
+358 96 158 701 +358 96 158 7285 janne.heikkila@kidde.fi www.kidde.fi
Tel: Fax: Email:
+55 19 2101 8456 +55 19 2101 8424
[email protected] www.kidde.com.br
MIDDLE EAST Kidde Limited Office 201, Bu Ameem Building 2 Karama Dubai PO Box 30791 UNITED ARAB EMIRATES
+86 21 616 11 800 +86 21 616 11 808
[email protected] www.utcfireandsecurity.com
Tel: Fax: Email:
Kidde China Room 304, 3/F Guardforce Centre 3 Hok Yuen Street East Hung Hom Kowloon HONG KONG
+00971 433 72498 +00971 433 75088
[email protected]
+852 2195 3688 +852 2370 8381
[email protected] [email protected]
Kidde India Limited EL 205, TTC Industrial Area Mahape, Navi Mumbai 400 710 – INDIA
+49 8217 48295 22 +49 8217 48295 10
[email protected] www.kidde.de
Tel : Fax: Email: Web:
Kidde Lietuva Lakunu Str 30 LT 09131 Vilnius LITHUANIA Tel : Fax : Email : Web :
SOUTH AMERICA
Kidde Sweden AB Box 90120 Virkesvagen 12 120 21 Stockholm SWEDEN
Kidde Brand-und Explosionsschutz GmbH Steinerne Furt 78 86167 Augsburg GERMANY Tel: Fax: Email: Web:
ASIA PACIFIC
+91 22 6780 3131 +91 22 2761 8444
[email protected] www.kiddeindia.com
Kidde Asia Pty Ltd 70 Bendemeer Road Luzerne #02-02 SINGAPORE 339940
+370 5 26 30040 +370 5 26 30031
[email protected] www.kidde.lt
Tel: Email: Web:
+65 642 47 970
[email protected] www.kiddeasia.com
“Kidde Fire Protection operates a continuous programme of product development. The right is therefore reserved to modify any specification without prior notice.”
A UTC Fire & Security Company
© Kidde Fire Protection 6586/1 04.09
PAGE 120/120
Designed and produced by Right Angle • www.rightangle.co.uk
www.kfp.co.uk
HOME
CONTENTS
ZOOM
PRINT
EXIT