Vigilon By Honeywell - Sovereign Fire And Security

   EMBED


Share

Transcript

by Honeywell Vigilon The Vigilon analogue addressable fire detection and alarm system from Gent offers medium to large sized building owners the latest in system flexibility and control panel aesthetics. LPCB approved to EN 54: Parts 2 & 4, Vigilon 1-4 loop control panels can accommodate up to 200 devices on each loop, including repeat panels, interfaces, call points, sensors and sounders. Up to 31 panels may be connected in a secure network, whilst multi layer networks can be created using a domain bridge architecture. Vigilon’s backlit LCD display presents clear indication of Fire or Fault location and the control panel’s innovative 8 -line x 40 character display with push-button keypad is simple to use. Fire Plans can be tailored to precisely meet site requirements. Vigilon’s software allows network areas to be sectored to evacuate or alert status, or configured with pre-set delays. Repeat Panel Fully compatible with Gent’s innovative new S-Quad - a combined Multi-Sensor range with speech, sounder and strobe in one intelligent unit. Manual Call Point l l l l l Because all Vigilon devices connect onto the same 2-core loop, separate sounder or repeater panel wiring circuits are not required. Selection of sensors to suit each building’s use will reduce false alarms and Vigilon’s comprehensive range includes heat, dual angle optical / heat and CO multi sensors, beam and duct smoke detectors. Optical or heat combined sensor/sounder/ strobe can also be deployed to boost alarm sound levels without costly additional wiring. In the event of a Fire or Fault, Vigilon’s analogue addressable technology will provide an entire historic log of the system’s management information. Vigilon allows full integration with additional outstations such as Supervisor graphics terminals and Vigilon Voice alarm systems. To meet the requirements of BS5839 Part 1: 2002 the Vigilon is supplied with integral zonal indication, visible at access level 1. This comprises of 32 fire LED’s (secret till lit), which enables ‘at a glance’ overview indication, without the need for manual intervention by fire fighters. T-breaker Sprinkler Interface Units Max Loop Length 1000m Alarm Sounder Additional features l Spur Door Release or Plant Shutdown S-Quad Sensor Sounder Beam Transmitter Beam Receiver S-Quad Sounder Strobe Supervisor Loop 1 Manned Centre Link to Fire Station Via Node to Trend Building Management Network Loop 2 Loop 3 Loop 4 Secure 3500 Fibre Network (up to 64 panels) Node ACU Secure 3500 Copper Network (up to 31 Panels) Node Loop 2 Loop 3 Loop 4 Node Secure Fibre Optic Loop 2 Loop 3 Domain Loop 4 (Max 200 panels per system) MIC Loop 1 S-Quad Sensor Up to 200 Devices per Loop DAU A4 Mimic Panel S-Quad Sensor/Speech Strobe by Honeywell Vigilon Dimensions (mm) A B C Control Panel 408 539 151 Battery Box 382 309 112 Repeat Panel 338 403 101 A4 Mimic Display 330 276 73 A4 Mimic Control Panel 483 385 78 A4 Mimic PANELS Type Max No of Loops Loop Capacity Batteries Battery Standby Approx Weight Control Panel Repeat panel A4 Mimic 4 N/A N/A 200 N/A N/A 4 x 12V @ 12AH 1 x 12V @ 6AH 4 x 12V @ 6AH 24 hours standby + 24 hours standby + 24 hours standby + 30 minutes alarm 30 minutes alarm 30 minutes alarm upgradeable to 72 hours upgradeable to 72 hours updradeable to 72 hours 16.2 Kg 6.2 Kg Sensors Display 2.3 Kg Control Panel 10.4 Kg 0°C to 45°C Operating Temp Cable Entry Beam Sensors (pair) EN54 pt 2+4 Relevant Standard Top and rear knockins Top or rear knockins Rear LPCB approved to EN54: Parts 2&4 Approvals Repeat panel Electronic Alarm Sounder A2 Mimic panel Manual Call Point by Honeywell Waterside Road E-mail Hamilton Industrial Park gent_enquir [email protected] Leicester L E5 1T N Website United Kingdom Te l + 4 4 ( 0 ) 11 6 2 4 6 2 0 0 0 w w w.gent.co.uk Fax + 4 4 ( 0 ) 11 6 2 4 6 2 3 0 0 L i t e r a t u r e r e f : G E N 010