Preview only show first 10 pages with watermark. For full document please download

Virtual Networking Of Offline Doors

   EMBED


Share

Transcript

Virtual networking of offline doors SALTO Virtual Network integration in IQ MultiAccess and IQ SystemControl Networking of several doors without the usual wiring effort – this vision becomes reality with SALTO Virtual Network (SVN). By means of offline door cylinders and door fittings in connection with IQ MultiAccess or IQ SystemControl complex access control systems can be established. In opposite to traditional offline solutions, where the door components must be regularly fed with the latest access authorizations, in this variant those data are on the data carrier. They will be updated regularly (at least once a day) at a central spot via a reader with write function which is online connected to the SALTO software. Information on disabled data carriers will be written onto each data carrier booking at the online reader and distributed to all doors the data carrier is presented to. Thereby a misusage of a found or stolen transponder can be prevented to the greatest possible extent. If a disabled transponder is presented to the online reader, it will automatically be blocked for the whole system. So any access to the object is prevented. If the disabled transponder is still in the building and presented to a door that already has got the barring information by another transponder, it will also be marked as invalid and has no access further doors. In return, events (bookings, battery state) of the doors will be written onto the data carrier and transferred from there to the SALTO software and IQMA / IQSC when the transponder is read the next time at the online reader. Data updates of every individual door within the daily routines via a programming device (PDA, laptop) does not apply, as the data are on the transponders and not in the door cylinders / fittings. Blacklists are distributed by the users´ transponders, door events will be retransferred to the access control software. As data have to be written onto the data carriers, at the moment this function is available with mifare transponders only (classic / DESFire EV1), LEGIC is in preparation. This option consists of the SALTO software, which is to be installed together with IQ MultiAccess / IQ SystemControl, inclusive an interface for data exchange between IQMA / IQSC and SALTO. The end user still works in IQMA / IQSC only and does not have to learn or operate any additional application. Features • Wireless networking of doors • Door components individually configurable • Authorizations are on data carrier • Invisible integration of SALTO-software in IQ MultiAcceess and IQ SystemControl. The user works with IQMA / IQSC user interface • Regularly update of authorizations at an online reader with write function • Blacklist: Automatic distribution of disabled data carriers to all door components via ident media • Onlinereader to be used as access control reader and / or for arming / disarming in addition to its update functionality. • Storage of users´ access events on identification media • Recordable data carriers, mifare classic and DESFire EV1, 1k recommended • Storage of battery status on identification media • (LEGIC in preparation) • Duration of validity freely programmable • Use of SALTO door cylinders / fittings Doors where wiring is not possible or wanted can be equipped with electronic door cylinders or fittings as an alternative. Besides a pure offline or online solution there is the possibility of a virtual network. Here the access authorizations are not stored at the door components but on the individual data carriers. They will be updated by regularly presenting at an online reader with write function and online connection. At this also information on invalid data carriers will be distributed to all doors a data carrier is read. IQ MultiAccess and IQ SystemControl support almost the complete SALTO-portfolio: Door cylinders: Euro profile half cylinders Configurator Cylinders and fittings are available in different types, lengths of profile cylinders (inside/outside), colours, surfaces and handle variants, which can be individually composed via a configuration tool. Euro profile standard cylinders The configurator is available for free download on the Honeywell homepage. Euro profile double cylinders The lengths of the locking cylinders are available in 5 mm steps starting from 30 mm inside / 30 mm outside. Door fittings: All components will be produced customer specific according to this information. Lead time is ca. 38 days. The SALTO software is running as a service in the background. Access authorizations at SVN doors will be defined via separate room/time zones in the personnel master file of IQMA / IQSC. A combination with access authorizations of wired doors is possible at any time. On the card only the data of SVN doors are stored. 2 With slim escutcheon (40 mm) With wide escutcheon (67 mm) with and without DIN-bore holes Connection of the SALTO components The online read/write station consists of a wall reader with write function (WRM9000) inclusive the corresponding control pcb for SVN and Ethernet connection (corresponding to CU50ENSVN without inputs and without outputs). Via this connection the reader communicates with the SALTO software and writes the authorizations according to the entries of IQMA / IQSC onto the transponders presented. Reader and control pcb are integrated in the so called UBOX9000. Additionally, a Wiegand interface to the reader will be provided by the adaptor pcb (CUADAP) which is included in the range of delivery. Using the Honeywell converter pcb (027901) the Wiegand output can be transformed to RS-485 format. Thus, the SALTO online reader can also be used as an access control reader at the ACS-8 module bus, at an IK3 evaluation unit or at an access control door module in parallel to its update functionality. If transponders are authorized accordingly, the IACP can be armed/disarmed by presenting the transponder twice to the online reader. Intruder access control system Access control system IQ SystemControl incl. SALTO software IQ MultiAccess incl. SALTO software IQSC IQMA Ethernet IK-3 EU or AC-DM BUS-2 ACSACS-8 Control via IQ SystemControl or connection to IQ MultiAccess Module bus RS-485 RS-485 Converter pcb 027901 Converter pcb 027901 Wiegand Wiegand 123-544 123-544 UBOX9000 with - Online reader - Control electronics with Ethernet connection - Adaptor pcb with Wiegand interface 91 - 62 - 91 90 - 60 - 90 Pers. no. Pers. no. Lindström, Kari-Anne Sunshine, Patricia Name w Name w w w 3 That´s how SVN works Who are you? Peter Miller May you enter me (room 102)? Yes What´s your time zone and your calender? Mo. - Fr. 07:00 - 16:30 h Info for you: Fred Fool has lost his card. Do not let him in when he presents his card. OK, the room is empty. I write the following information onto your card: Room 102, date 16. 07. 2012,10:35 h. And I need new batteries. Door handles Door fittings are suitable for doors with a door thickness as of 30 mm. For the fittings there is a range of different handle variants. The standard handle is variant “U”. *Some layout variants are at extra charge. 4 Accessoires The UBOX9000 is a set consisting of: • A wall reader for updating the transponders • Control electronics with Ethernet connection • Adaptor board for Wiegand interface • Mounting frame for wall reader • Housing • .......... Zusatzfunktionen – ......... Platine für Online-Terminal zur Ausgabe von Wiegand Online read/write station – ......... Dadurch über Konverterplatine anschließbar an: – ......... IK3 AWE / ZK Türmodul – ......... oder ACS8 – ......... und als Leser / Schalteinrichtung nutzbar By help of this box, the online reader can be connected to the SALTO software via Ethernet. The Wiegand interface is used for a connection of this reader to the ACS-8 module bus, the IK3 evaluation unit or the access control door module in parallel. For the transformation from Wiegand to RS-485 the Honeywell converter pcb (item no. 027901) is required. Using the converter pcb for connection to: • IK3 evaluation unit / access control door module • or ACS-8 • and so to be used as a reader or switching device 5 Accessoires With installation only once the door data have to be entered in the SALTO software and distributed to the doors via a mobile programming. The programming device PPD800 helps the installer for initial setting up the doors. The end-user can use it for emergency openings (if required) and to read out the event data of the doors. Programming device The encoding device EC90EN works as a dongle and must be connected at least once per project. Here the transponders will be initialized with the SALTO segment on initial setup. Furthermore, transponders of the blacklist can be reactivated only via this device. Connection via Ethernet. The encoding device EC90USB does not provide a dongle function. It can be used in addition to EC90EN. Connection via USB. Encoding device Equipment variants of the door components* Door cylinders and fittings are available in the surfaces: • Brass polished • Brass antique • Brass matt finish • Stainless steel matt finish On BioCote® protected surfaces it has been shown that levels of microbes can be reduced by up to 99.9%. All BioCote® protected products are regularly validated and quality control tested to ISO 22196 where applicable, in an independent laboratory. The BioCote® brand is a guarantee of superior antimicrobial performance to protect product surfaces from deterioration. • Stainless steel polished • RAL white • RAL black A special, antimicrobial surface for use in hospitals, laboratories, catering or in the food industry provides BioCote®. “Antimicrobial” describes a substance with the possibility to resist the growth of microbes, e. g. bacteria and moulds. BioCote® antimicrobial protection is based on silver ion technology. This technology, in the form of an additive, is incorporated into products at the time of manufacture. Extensive testing has proven BioCote® will retain its antimicrobial properties, providing continuous antimicrobial protection for the lifetime of the product. 6 *Some layout variants are at extra charge. Bestelldaten Mandatory items for the first order: 0296xx IQ MultiAccess Basic package or 013596 IQ SystemControl 029650 Option SALTO SVN Includes the required SALTO software and the interface Salto – IQMA/IQSC. 029651 Number of SALTO readers This option is at extra charge but it will be discounted by 100% if the door cylinders / fittings are ordered at Honeywell. SA00220 SAM-Kit/Software Master key for initialization of transponders via the encoding device EC90EN. This corresponds to the security document of conventional locking systems. EC90EN Encoding of the transponders with the SALTO segment and allocation of the access authorizations. Works simultanuously as a dongle. Encoding device with Ethernet connection UBOX9000 Online reader station complete Updating of the transponders during daily routines. Distribution of the blacklist. Receiving of data from transponders and forwarding of the information to the AC-software. To be operated as an access control reader and/or for arming/ disarming at the same time using the converter pcb. 027901 Converter pcb For connection of the online reader to ACS-8 module bus (communication module in ACS-8 required), IK3 evaluation unit or access control door module. PPD800 Programming device For the installer at least one device is mandatory in order to initialize the doors. One device can be used to manage an arbitrary number of customers´ systems. Optional each customer can have his own programming device in order to do emergency openings or firmware updates or to read out data. The order numbers of the door components (cylinders, fittings) result of the many possible combinations to be determined using the configurator. Due to this they cannot all be listed here. 7 Honeywell Security Group Novar GmbH Johannes-Mauthe-Str. 14 · D-72458 Albstadt Phone: +49 (0) 74 31/ 801- 0 · Fax: 801-12 20 www.honeywell.com/security/de [email protected] P32831-22-0G0-00 11. 2012 · Subject to change without notice.  2012 Honeywell International Inc.