Vision™ OPLC™ Economy model, PLC + 5,7” color display Technical Specifications Models V570-57-T20B, V570-57-T40B This guide provides specifications for Unitronics’ color touchscreen controllers V570-57-T20B and V570-57-T40B.
Technical Specifications Power Supply Input voltage Permissible range Max. current consumption
V200-18-E2B
V570-57-T20B
24VDC 20.4 VDC to 28.8VDC with less than 10% ripple V570-57-T20B V570-57-T40B 270mA@24V 320mA@24V
Battery Back-up Replaceable
7 years typical at 25°C, battery back-up for RTC and system data, including variable data. Yes, without opening the controller.
Graphic Display Screen LCD Type Illumination backlight Display resolution, pixels Viewing area Colors Touchscreen ‘Touch’ indication Screen brightness Keypad
V570-57-T20B V570-57-T40B TFT TFT White LED CCFL fluorescent lamp 320x240 (QVGA) 5.7” 256 Resistive, analog Via buzzer Via software (Store value to SI 9). Displays virtual keyboard when the application requires data entry.
Program Memory size Operand type Memory Bits Memory Integers Long Integers Double Word Memory Floats Timers Counters Data Tables HMI displays Program scan time
Application Logic – 2MB, Images – 6MB, Fonts – 1MB Quantity Symbol Value 8192 MB Bit (coil) 4096 MI 16-bit 512 ML 32-bit 256 DW 32-bit unsigned 64 MF 32-bit 384 T 32-bit 32 C 16-bit 120K dynamic data (recipe parameters, datalogs, etc.) 192K fixed data (read-only data, ingredient names, etc) Up to 1024 9 µsec per 1K of typical application
Removable Memory SD card File system User must format via Unitronics SD tools utility. See Note 1 Notes: 1. The SD memory card slot uses the PC-compatible FAT32 file system. User can store datalogs, Alarm history, Data Tables, backup Ladder, HMI, and OS, up to 2GB.
www.klinkmann.com
Vision™ OPLC™ Communication Serial ports RS232 Galvanic isolation Voltage limits Baud rate range Cable length RS485 Galvanic isolation Voltage limits Baud rate range Nodes Cable type Cable length CANbus port Nodes Power requirements Galvanic isolation Cable length/baud rate
2. See Note 2 Yes ±20VDC absolute maximum 300 to 115200 bps Up to 15m (50’) Yes −7 to +12VDC differential maximum 300 to 115200 bps Up to 32 Shielded twisted pair, in compliance with EIA RS485 1200m maximum (4000’) 1 CANopen Unitronics’ CANbus protocols 127 60 24VDC (±4%), 40mA max. per unit Yes, between CANbus and controller 25 m 1 Mbit/s 100 m 500 Kbit/s 250 m 250 Kbit/s 500 m 125 Kbit/s 500 m 100 Kbit/s 1000 m* 50 Kbit/s 1000 m* 20 Kbit/s * If you require cable lengths over 500 meters, contact technical support. User may install a single Ethernet port, or an RS232/RS485 port. Available by separate order.
Optional port Notes: 2. The standard for each port is set to either RS232/RS485 according to DIP switch settings. Refer to the Installation Guide.
I/Os Snap-in I/O modules Expansion modules
Exp. port isolation
Number of I/Os and types vary according to module. Supports up to 512 digital, high-speed, and analog I/Os. Plugs into rear port to create self-contained PLC with up to 43 I/Os. Local adapter (P.N. EX-A1), via I/O Expansion Port. Integrate up to 8 I/O Expansion Modules comprising up to 128 additional I/Os. Remote adapter (P.N. EX-RC1), via CANbus port. Connect up to 60 adapters; connect up to 8 I/O expansion modules to each adapter. Galvanic
Dimensions Size 197X146.6X68.5mm “ 7.75 ( X “ 5.77 X2.7”). See Note 3 Weight 750 gm (26.4 oz) Notes: 3. For exact dimensions, refer to the product’s Installation Guide.
Mounting Panel-mounting
Via brackets
Environment Inside cabinet Panel mounted Operational temperature Storage temperature Relative Humidity (RH)
IP20 / NEMA1 (case) IP65 / NEMA4X (front panel) 0 to 50ºC (32 to 122ºF) -20 to 60ºC (-4 to 140ºF) 5% to 95% (non-condensing)
www.klinkmann.com
I/O Expansion Modules Expand your system with local or remote I/O expansion modules1. Vision series support both local & remote I/O modules. M90/M912 support local modules only.
Digital Modules IO-DI8-TO8
IO-DI8-RO4
IO-DI8-RO8
EX90-DI8-RO83
IO-DI16
24VDC 8 Digital Inputs, pnp/npn, including one High-speed Counter 8 pnp Transistor Outputs
24VDC 8 Digital Inputs, pnp/npn, including one High-speed Counter 4 Relay Outputs
24VDC 8 Digital Inputs, pnp/npn, including one High-speed Counter 8 Relay Outputs
24VDC 8 Digital Inputs, pnp, including one High-speed Counter 8 Relay Outputs
24VDC 16 Digital Inputs, pnp/npn, including one High-speed Counter
IO-TO16
IO-RO8
IO-RO16
IO-DI8ACH
12/24VDC 16 pnp Transistor Outputs
24VDC (power supply) 8 Relay Outputs
24VDC (power supply) 16 Relay Outputs
110/220 VAC 8 AC Inputs
Analog, Temperature and Weight/Strain Measurements
XL Digital/Analog Modules
IO-AI4-AO2
IO-PT400
IO-PT4K
24VDC (power supply) 4 Analog Inputs, 12 bit, 0-10V, 0-20mA, 4-20mA, 2 Analog Outputs 12 bit+sign, ± 10V, 0-20mA, 4-20mA
4 PT100/NI100/NI120 Inputs Range PT100: -50°C...460°C (-58°F...860°F) Range NI100: -50°C...232°C (-58°F...449°F) Range NI120: -50°C...172°C (-58°F...341°F) 12 bit
4 PT1000/NI1000 Inputs Range PT1000: -50°C...460°C (-58°F...860°F) Range NI1000: -50°C...232°C (-58°F...449°F) 12 bit
IO-AO6X
IO-LC14
24VDC (power supply) 6 Isolated Analog Outputs, 0-10V, 0-20mA, 4-50mA, 12 bit
IO-D16A3-RO165 24VDC 16 Digital Inputs, pnp/npn, including two High-speed Counters 3 Analog Inputs 10 bit, 0-20mA, 4-20mA, 16 Relay Outputs
New!
IO-ATC8
IO-D16A3-TO165
8 Thermocouple/Analog Inputs, T/C J, K, T, B, E, N, R, S, 0.10 Resolution, 0-10V, 0-20mA, 4-20mA, 12/14 bit
24VDC 16 Digital Inputs pnp/npn, including one New! High-speed Counter 3 Analog Inputs 10 bit, 0-20mA, 4-20mA 15 pnp + 1 pnp/npn Transistor Outputs including 1 HSO
IO-LC34
12/24VDC (power supply) 1-3 Loadcell / Strain gauge Inputs Input voltage ranges: ±20mV, ±80mV Excitation: AC/DC 1 Digital pnp Input 2 Setpoint pnp Outputs
CE/UL
Not supported by all OPLCs™
Number of I/Os may vary according to module Except for M90-19-B1A 3 The EX90 is housed in an open casing. Only one EX90 can be connected per PLC, as a single expansion module; Expansion adapter not required 4 IO-LCx models are supported by the M91 & Vision series. Not supported by the M90 series. 5 XL expansion modules will be available in spring 2009. Not yet UL certified 6 EX-RC1 is supported by Vision series. Not supported by M91 series. Not yet UL certified. 1
I/O Expansion Module Adapters EX-A1
EX-RC16
Local I/O module adapter. Up to 8 modules may be connected to a single PLC1. Supports both 12/24 VDC.
Remote I/O module adapter, via CANbus. Multiple adapters may be connected to a single PLC, with up to 8 modules to each adapter1. Supports both 12/24 VDC.
2
* Additional 12VDC models are listed on Unitronics web site.
www.klinkmann.com
I/O Expansion Modules Snap-in I/O Modules Plug a Snap-in module directly into the back of a Vision PLC. Compatible with all V200 & V500 (V2XX, V5XX) Vision models. New! V200-18-E1B
V200-18-E2B
V200-18-E3XB
V200-18-E4XB
V200-18-E5B
V200-18-E6B1
16 isolated Digital Inputs (including 2 Shaft-encoder Inputs.
16 Isolated Digital Inputs (including 2 Shaft-encoder Inputs)
18 isolated Digital Inputs (including 2 Shaft-encoder Inputs)
18 isolated Digital Inputs (including 2 Shaft-encoder Inputs)
18 isolated Digital Inputs (including 2 Shaft-encoder Inputs)
18 isolated Digital Inputs (including 2 Shaft-encoder Inputs)
3 Analog Inputs
2 Analog Inputs
3 Analog Inputs
4 isolated Transistor Outputs (including 2 High-speed Outputs)
4 isolated Thermocouple/PT100/ Analog Inputs
3 Analog Inputs
4 isolated Transistor Outputs (including 2 High-speed Outputs)
4 isolated Thermocouple/PT100/ Analog Inputs
10 isolated Relay Outputs
17 isolated Transistor Outputs (including 2 High-speed Outputs)
2 Thermocouple/ PT100/Analog Inputs
10 isolated Relay Outputs
2 isolated Transistor Outputs (including 2 High-speed Outputs)
17 isolated Transistor Outputs (including 2 High-speed Outputs)
15 isolated Relay Outputs
4 isolated Analog Outputs
2 Analog Outputs
2 isolated Transistor Outputs (including 2 High-speed Outputs) 15 isolated Relay Outputs
4 isolated Analog Outputs
2 isolated Analog Outputs 1
V200-18-E6B is not yet UL certified
Additional COM Module Use these modules to enhance Vision’s communication capabilities1 1 Ethernet port
1 RS232/RS485 port
1 isolated RS232/RS485 port
1 CANbus port
V100-17-ET22 (for V130 & V350 Series)
V100-17-RS42 (for V130 & V350 Series)
V100-17-RS4X2 (for V130 & V350 Series)
V100-17-CAN2 (for V130 & V350 Series)
V200-19-ET1 (for V200 & V500 series)
V200-19-RS4 (for V200 & V500 series)
V200-19-RS4-X (for V200 & V500 series) 1
V200/V500: 1 optional port, V130/V350: 1 optional port for serial or Ethernet & 1 optional port for CANbus 2 V100-17-ET2, V100-17-RS4, V100-17-RS4X & V200-17-CAN are not yet UL certified
www.klinkmann.com
Koulutuskurssit Unitronics miniPLC+display Vision logiikat, ml. langattomat liitynnät PERUSKURSSIT SYKSY 2010 (1 pv 24.9, 29.10, 26.11) Klinkmann Automaatio järjestää Unitronics miniPLC+display logiikoista yhden päivän peruskurssia, jonka aikana käydään läpi logiikkamallit, laajennusyksiköt sekä tietoliikenne ml. GSM/GPRS/3G mobiiliverkko, ethernet, web-server, sarjaliikenne ja modbus yhteydet. Kurssi sopii kaikille Unitronics logiikoista ja langattomasta automaatiosta kiinnostuneille. Yli 4-henkilön ryhmille järjestämme myös asiakaskohtaista koulutusta. Kurssin ohjelma Aamukahvi ja esittely 09.00 Unitronics tuoteperhe. 09.30 Unitronics Ladder PC-logiikkaohjelmisto. Ohjelmointi, harjoituksia ja sovelluksen lataus logiikkaan. Lounas 12.00 Sovellusharjoitukset jatkuvat. 13.00 Unitronics näyttöjen konfigurointi PC:llä, harjoitus. Tietoliikenneyhteydet - GSM/GPRS modeemi (Siemens MC35iT) - ethernet ja internet Kauko-ohjelmointi ja sovelluksen etäkonfigurointi mobiiliverkon avulla. 15.00 Kurssin päätös. 16.00 Kurssin tavoite Antaa perustiedot Unitronics miniPLC+display logiikoista: logiikka- ja näyttöohjelmointi sekä tietoliikenneyhteydet. Paikka Klinkmann toimitalo (Eniro 2010: karttasivu 51/80-DE Fonseenintie 3, 00370 Helsinki koulutustila 2.krs). Hinta € 300,- (alv 0%) sisältäen kurssin ja materiaalin sekä lounaan. € 450,- (alv 0%) sisältäen kurssin, materiaalin ja lounaan sekä Unitronics V130 (tuote n:o V13033R2) logiikan graafisella näytöllä ja Unitronics PC-ohjelmistot PLC/display konfigurointiin ja PC-yhteyksiin. Asiakaskohtainen koulutus erikseen sovittuina päivinä € 1000/pvä. TARJOUS (1 kpl/asiakas)! € 399,- (alv0%) sisältäen kurssin, materiaalin, lounaan sekä Unitronics V570 logiikan ja SNAP-in I/O (tuote n:o V570-57-T20B + V200-18-E2B) ja Unitronics PC-ohjelmistot PLC/display konfigurointiin ja PC-yhteyksiin Lisätiedot ja ilmoittautuminen E-mail:
[email protected] puh. 09-540 4940
2009 kevät
Jazz™ miniPLC + display with SMS-operations HMI
PLC
Up to 60 user-designed screens Multilingual: supports over 15 languages and 20 graphic symbols Scroll between pre-programmed recipes/menus
Ladder Logic programming ensures functional flexibility Functions include: interrupt, loops, math, store & compare functions Time-based control in 3 clicks High-speed counters Print utilities Full source upload
Communication SMS messaging via GSM (send, receive) Remote Access utilities PC access via MODBUS or OPC server MODBUS networking
www.klinkmann.com
Jazz™ Micro-OPLC™ Much more than a “smart relay”. Full function PLC & HMI, with up to 40 onboard I/Os, all in one device JZ10-11-R10 JZ10-11-T10
Article Number
JZ10-11-R16
JZ10-11-T17
JZ10-11-R31
JAZZ special offer 59€ package includes: - JZ10-11-R16 PLC+display - JZPRG PC programming software+cable
JZ10-11-T40 JZ10-11-PT15
I/O Inputs
6 Digital
6 Digital
6 Digital 2 Digital/Analog 2 Analog
6 Digital 2 Digital/Analog 2 Analog
16 Digital 2 Digital/Analog 2 Analog
16 Digital 2 Digital/Analog 2 Analog
3 Digital 3 Digital/Analog 3 PT1000/NI1000
Outputs
4 Relay
4 Transistor
6 Relay
7 Transistor
11 Relay
20 Transistor
5 Relay 1 Transistor
2 HSI
2 HSI
2 HSI
2 HSI
2 HSI
1 HSI & 1 HSO
Including High-speed I/Os
2 HSI
Program
Jazz™ Micro-OPLC™
Ladder Code Memory
24К (virtual)
Operand Capacity
256 coils, 256 registers, 64 timers
Operator Panel Type
STN LCD
Display Size
2 lines x 16 characters
Keypad Number of keys
16 keys, 10 of which are user-labeled
General Power Supply
24 VDC
Battery Back-up
10 years typical at 25°C, battery back-up for all memory sections and real-time clock (RTC)
Environment
IP65/NEMA4X (from panel, when mounted)
Clock (RTC)
Real-time clock functions (date and time)
Add-on modules1 & accessories Programming Kit
СОМ port kit2
Program Cloner module
Keypad slide kit
Programming Add-on port (isolated) + software CD Article No.: JZPRG
RS232/RS485 Add-on port (isolated) Article No.: JZ-RS4
Copy applications from PLC to PLC Article No.: MJ20-MEM1
Customize the Jazz keypad to your application Article No.: MJ20-JZ-SL1
1
CE/UL
2
In order to download applications and enable communications, install Jazz™ with an add-on module containing a COM port The RS232/RS485 add-on port is not yet UL certified
… Replace that “smart-relay” with a real PLC/HMI...
www.klinkmann.com
Helsinki tel. +358 9 540 4940
[email protected]
Yekaterinburg tel. +7 343 376 5393
[email protected]
Mineralnye Vody Санкт-Петербург tel. +7 87922 6 193752 34 тел. +7 812 327
[email protected] [email protected]
Samara Самaра tel.+7 +7846 846993 3424933 6655 тел.
[email protected] [email protected]
Кiev Rīga tel. +38 044 495 3340
[email protected] [email protected]
Riga tel. +371 6738 1617
[email protected]
Москва Vilnius тел. +7 495 641 1616 tel. +370 5 215 1646
[email protected] [email protected]
Київ Tallinn тел. +380 444 953 340 tel. +372 668 4500
[email protected] [email protected]
Vilnius Мinsk tel. +370 5 215 1646 tel. +375 17 200 0876
[email protected] [email protected]
St. Petersburg tel. +7 812 327 3752
[email protected]
Moscow tel. +7 495 641 1616
[email protected]