Preview only show first 10 pages with watermark. For full document please download

Vislink - Phase Engenharia

   EMBED


Share

Transcript

PHASE | VISLINK: Sistemas de Transmissão via Redes de Celular e IP  IPLink Digital Video/Data Microwave Systems…………………..p. 2  IPLink-SM Split Mount Indoor/Outdoor Microwave Systems…..p. 4  NewStream Multi-mode Van/OB Transmit System……………...p. 6  LGR-1000 LiveGear Receiver……………………...……………...p. 8 IPLink Next Generation Digital Video/Data Microwave Systems IPLink combines the features of a broadcast digital microwave point-to-point radio system with the modern efficiencies of a high-capacity long-distance bi-directional IP microwave radio design. It allows the broadcaster to smoothly migrate from the traditional ASI transport platform to a future IP-centric system architecture. The system delivers ultra-high linear RF output performance coupled with the reliability that LDPC forward error correction (FEC) affords in controlling errors in data transmissions over long or unreliable microwave paths. A key advantage of the IPLink is that it allows BAS 7 & 13 GHz simplex links to be transformed into affordable duplex IP Ethernet microwave systems within a T/R channel spacing as close as 75 MHz; a Vislink first. Systems are available in Simplex, Duplex, Hot-Standby and *Spatial Diversity Receive configurations. *Seamless switching available for non-protected duplex space diversity receive system configurations only. Key Features Typical Applications ■■ All-indoor, space efficient 2RU x 19” (48cm) rack-mount ■■ Ultra-high linear broadband RF power amplifiers ■■ Exceptional System Gain Performance ■■ High capacity ASI & Gigabit Ethernet IP data transport ■■ Automatic Transmitter Power Control ■■ Adaptive Code Modulation ■■ User selectable modulations from QPSK to 256 QAM ■■ ANSI and ETSI channel bandwidths ■■ Intuitive Web-based GUI for monitoring/control ■■ Studio-to-Transmitter Links (STL) ■■ Transmitter-to-Studio Links (TSL) ■■ Inter-city Relay Backhauls (ICR) ■■ Multi-hop Microwave Relay Systems ■■ High-capacity IP Microwave Systems SPECIFICATIONS RF PARAMETERS RF Power Output Level (prior to filter branching) ■■+34dBm to +27dBm* @ 6 GHz BAS ■■+33dBm to +26dBm @ 7 GHz ■■+32dBm to +25dBm @ 8 GHz ■■+29dBm to +22dBm @ 13 GHz BAS RF Band Support* ■■6.425 – 7.125 GHz (FCC TV-BAS) ■■7.100 – 7.900 GHz (ETSI) ■■7.725 – 8.500 GHz (ETSI) ■■12.700 – 13.250 GHz (FCC TV-BAS) * Consult factory for additional RF band support Channel Filter Branching Network Assemblies* ■■50 MHz typ. T/T & R/R @ 7 & 13 GHz FCC-BAS ■■75 MHz typ. T/R @ 7 & 13 GHz FCC-BAS ■■Waveguide Interface: WR137 @ 7 GHz, WR75 @ 13 GHz * (Modulation dependent) * Consult factory for additional WG interface availability DATA TRANSPORT PARAMETERS PRIME POWER (MAINS) PARAMETERS Modulations ■■QPSK, 8PSK, 16 QAM, 32 QAM, 64 QAM, 128 QAM, 256 QAM Automatic Transmitter Power Control (ATPC) Data Throughput Capacity (one-way) ■■10 Mbps to 360 Mbps Encryption ■■AES 256 Adaptive Code Modulation (hitless 0ms) 100W (power consumption) switching ■■AC (90-132V & 180-264V @ 47 – 63 Hz) USER INTERFACE PARAMETERS Ethernet (payload) ■■2 x 100/1000 Base-T, RJ-45 ■■Gigabit Ethernet line rates scalable up to 360 Mbps ■■IPv4 and IPv6 ■■VLAN 802.1Q ■■64 level DiffServ (DSCP) QoS or 8 level 802.1p in 4 prioritization queues with VLAN support ASI (payload) ■■4 x ASI simplex transmit (BNC-F) ■■4 x ASI simplex receive (BNC-F) ■■4 x ASI individually configured per direction for duplex (BNC-F) MECHANICAL PARAMETERS ■■Weight: 18 lbs. (8.2 kg) (approx) ■■2 RU x 19” (48cm) EIA Rack Mount ■■15.0” depth (38cm) exclusive of filter branching ENVIRONMENTAL PARAMETERS Hot-Standby ASI Transmit Switch ■■2 x 1 DA Hot-Standby ASI Receive Switch ■■2 x 1 A/B typ. 40 msec. Hot-Standby Ethernet TCP/IP Switch ■■600 - 1100 msec. Local and Remote Link Web-browser Management ■■1 x 100/1000 Base-T (RJ-45) System Management Interface Parameters ■■Hot-Standby and Space Diversity (1+1) ■■1x DB9 for Alarm Fault switching – RF PA, RSL, etc. Operating to full specifications ■■0 ˚ to +50˚ C (32˚ to 122˚ F) ■■Humidity up to 95% noncondensing Operational ■■-10˚ to +60˚ C (14˚ to 140˚ F) Storage ■■-40˚ to +70˚ C (-40˚ to +158˚F) REGULATORY PARAMETERS ■■FCC Type Certification in accordance with CFR 47 Part, subpart J including: ■■CFR 47, Part 74, subpart J ■■CFR 47, Part 101, subparts C, H and I ■■FCC part 15 EMC unintentional emission radiators ■■ETSI; EN 301 489-1, 489-28, EN 302 064-1 ■■Safety per EN/CE EN60950 LICENSE KEY UPGRADES: ■■IPLink-365-LIC ■■200 Mbps to 360 Mbps data throughput license (per nonprotected terminal) www.vislink.com • [email protected] RD001881 Rev 2.4 11/02/16 ENG © 2015 Vislink Group. All rights reserved. All other products or services referenced herein are identified by the trademarks or service marks of their respective companies or organisations. Note: Vislink reserves the right to change specifications without notice. Please contact your representative to confirm current specifications. IPLink-SM Split-Mount Indoor/Outdoor Digital Video/Data Microwave Systems IPLink-SM is a “split-mount” bi-directional point-to-point IP microwave system consisting of a tower mounted RF unit (ODU) and an indoor rack-mounted baseband Ethernet modem (IDU). The ODU is powered via a low loss interconnecting IF coaxial cable for distances up to 1000 feet (300m). Mounting the RF ODU directly to, or in close proximity to the antenna maximizes system gain performance over that of an all-indoor system that incurs the transmission line loss associated with waveguide infrastructures. The radio system is available for Ethernet only, Ethernet plus ASI or Ethernet plus E1/T1 applications with halfduplex data rates (payload) up to 360 Mbps and in 1+0, 1+1 and 2+0 configurations. The IPLink-SM supports a wide range of frequency bands between 3.5 and 38 GHz for ETSI and FCC operation and covers channel bandwidths from 3.5 to 56 MHz. Key Features Typical Applications ■ Split-mount, space efficient 1RU x 19” (48cm) rack-mount IDU and tower mounted ODU (IP65 rated) ■ Standard & High RF linear broadband RF power outputs ■ Automatic Transmitter Power Control ■ Adaptive Code Modulation ■ User selectable modulations from QPSK to 256 QAM ■ High capacity Gigabit Ethernet IP data transport ■ Optional high stability ASI or multiple E1/T1 IDU versions ■ Intuitive Web-based GUI for monitoring/control ■ ■ ■ ■ ■ Studio-to-Transmitter Links (STL) Transmitter-to-Studio Links (TSL) Inter-city Relay Backhauls (ICR) Multi-hop Microwave Relay Systems High-capacity IP Microwave Systems SPECIFICATIONS www.vislink.com • [email protected] © 2015 Vislink Group. All rights reserved. All other products or services referenced herein are identified by the trademarks or service marks of their respective companies or organisations. Note: Vislink reserves the right to change specifications without notice. Please contact your representative to confirm current specifications. NewStream Multi-mode Van/OB Transmit System NewStream raises the bar as the most comprehensive mobile broadcast microwave transmission system available today. It combines both licensed and unlicensed RF technologies together, all within an operator-friendly platform. The NewStream IDU (Indoor Unit) offers a unique type of multi-mode operation which can include ENG (Electronic News Gathering), SNG (Satellite News Gathering) and CNG (Cellular News Gathering) in a space efficient 2-RU (3 ½") by 19" EIA rack-mount chassis. The system includes both MPEG-2 and H.264 AVC (MPEG-4) HD/SD video/ audio encoding for ENG and SNG applications and for CNG operations, H.264 ABR (adaptive bit rate) coding to compensate for the dynamic signal fluctuations commonly associated in cellular network infrastructures. NewStream’s IDU employs advanced programmable OLED (organic light-emitting diode) push button switches which automatically configure themselves based upon the user’s desired mode of operation. The use of OLED smart switches significantly reduces front panel congestion by repurposing otherwise dedicated switches for different operating modes. In addition, they can also provide a color or graphic change-of-status indication in the same switch. For ENG applications, NewStream includes an all-inclusive mast-mounted ODU (Outdoor Unit) providing 2 GHz or 2 & 7 GHz ultra-linear high RF power output digital amplifiers. It interconnects with the IDU via coaxial or triaxial cable and contains an ancillary RF coax relay to switch between a high-gain directional or optional Omni-directional antenna. For CNG operations the IDU communicates with a separate cellular ODU that is either roof-top or mast-mounted by means of a MoCa Power over Ethernet (PoE) bridge connection utilizing any standard RG-58 or RG-59 coaxial cable, typically found in most legacy Nycoil assemblies. Mast-mounting the cellular ODU potentially increases broadband cellular connectivity that could be weakened in more congested roof-top mounted installations. Multiple cellular modems inside the ODU are “bonded” together for the seamless transmission of high quality HD (highdefinition) video over 3G/4G LTE network service providers such as Verizon, AT&T and T-Mobile. For SNG applications the NewStream IDU provides control of a fully featured integrated satellite upconverter with L-band output, DVB-S and DVB-S2 modulation. THE NEWSTREAM ADVANTAGE: Cost effective, space saving and user-friendly multi-purpose Van/ OB microwave transmission system. ■■ Compact: Space-efficient 2RU x 19" EIA all-inclusive rack mount design for ENG, CNG and SNG control. ■■ Operator-friendly: Ergonomic programmable multifunction OLED push button switches minimize front panel controller congestion. ■■ Backwards Compatibility: Use existing ENG Nycoil Assemblies configured for Type ‘N,’ Triax connections. ■■ Expandable: Purchase a NewStream system initially configured for ENG operation and then add CNG and/or SNG functionality at a later time. ■■ Space Efficient ENG ODU: 2, 4, 7, 13, 2/7 GHz mastmounted single enclosure with built-in RF coaxial relay for omni-directional antenna selection. ■■ Broadband Cellular ODU: Lightweight mast or roofmounted cellular ODU equipped with multiple bonded cellular modems and integral high-gain broadband cellular antennas. ■■ HD/SD Broadcast Video Quality: User selectable MPEG-2 or H.264 (AVC) encoding available in 4:2:0 and 4:2:2 profiles. ■■ CNG Encoding: H.264 AVC high-profile @ level 4.1 adaptive bit-rate coding (ABR) encoding. ■■ SNG: DVB-S and DVB-S2 modulation with optional 10 MHz. ■■ Video Inputs: Composite video & HD/SD-SDI. ■■ Audio: Two embedded SDI MPEG-2 layer II and two Analog stereo pairs. ■■ Future-proof: NewStream is based upon a software defined platform employing high capacity dual-core ARM® Cortex-A9™ FPGAs (field-programmable gate arrays) which allow for the future implementation of emerging communication technologies. Key Features Typical Applications ■■ Operator-friendly OLED switches ■■ Backwards Compatibility ■■ Industry-First Cellular ODU ■■ Future-Proof ■■ Space Efficient 2 rack Unit ■■ Electronic Newsgathering ■■ Satellite Newsgathering ■■ Cellular Newsgathering SPECIFICATIONS ENG CELLULAR SNG OUTDOOR UNIT (ODU)-RF Mast-mounted (single enclosure) Mast-mounted (single enclosure) Optional: Roof-mounted NewSwift, Mantis 2-2.5 GHz 8 Watts (typ.) +/- 1dB @ QPSK, 64 QAM N/A N/A 4.5-5.0, 6.4-7.1, 6.9-7.5 GHz 5 Watts (typ.) +/- 1dB @ QPSK, 64 QAM N/A N/A 12.7-13.25 GHz CDMA, UMTS, HSPA+, LTE IDU to ODU interconnection 1.5 Watts (typ.) +/- 0.5 dB @ QPSK N/A RG-6/U minimum or better N/A N/A 6-modems, Bonded RG-58/U or RG-59/U N/A LMR-400 or equivalent 7" w x 10" l x 6" h 16 lbs. (max. @ 2/7 GHz) -20º to +50ºC 10" w x 14" l x 5" h 10 lbs. -20º to +50º C Size and Weight, ODU Temperature INDOOR UNIT (IDU) TBD TBD Rack-mount chassis, single (5) Programmable OLED (organic light-emitting diode) push-button switches, (2) rocker-style switches, (3) LED push-button switches, (1) On/Off push-button switch Operator Controls (1) Capacitive color touch TFT 5.0" diagonal 800 x 480 white LED backlight display, (2) 16 x 2 segment mono-chromatic blue OLEDs 3 Operating Modes-Interview, Standard, Up to 99 User configurable Up to 99 User configurable Mobility BNC - (ASI In, ASI Out, SDI In, CV in, 75 Ω audio, spare) Weidmuller - (analog audio 1L/1R, 2L/2R, digital audio D1, D2, MW ODU power, Ant.) Type ‘N’ or Triax (ODU 2/7 GHz or 2 GHz and 7 GHz legacy MTX ODUs) Type ‘N’ - (L-band Mod. & L-band Mon.); TNC - (to cellular ODU) Miscellaneous- (1) SMA Wi-Fi, (3) RJ45 Ethernet, (1) 115 VAC IEC C14, (1) DB-9 data, (1) USB Displays Presets Rear panel I/O 17.0" W x 16.2" L x 3.5" H (2RUx 19" EIA standard rack-mount), 16 lbs/.45 kg Size and Weight, IDU Prime operating power 115/230 VAC, 2.0 A (typ) Temperature -10º to +40º C MODULATION COFDM (DVB-T) OFDMA, CDMA DVB-S QPSK, DVB-S2 QPSK Optional Modulations N/A VIDEO INPUT FORMATS LMS-T 10/20 HD/SD-SDI HD/SD-SDI DVB-S2 8PSK, 16/32 APSK HD/SD-SDI VIDEO RESOLUTIONS HD & SD HD & SD HD & SD High Definition 1080i, 1080p, 720p 1080i, 1080p, 720p Standard Definition 720 x 480i (NTSC), 720 x 576i (PAL) 720 x 480i (NTSC), 720 x 576i (PAL) 1080i, 1080p, 720p 720 x 480i (NTSC), 720 x 576i (PAL) VIDEO ENCODING PROFILE MPEG-2, H.264 HD/SD, 4:2:2/4:2:0 HD Encoding Rate @ 4:2:2 (MPEG-2) 8.0 to 30 Mbps H.264 AVC HD/SD 4:2:0 High Profile @ Level 4.1 N/A HD Encoding Rate @ 4:2:0 (MPEG-2) 8.0 to 30 Mbps N/A 8.0 to 80 Mbps SD Encoding Rate @ 4:2:2 (MPEG-2) 2.0 to 50 Mbps N/A 2.0 to 50 Mbps SD Encoding Rate @ 4:2:0 (MPEG-2) 1.5 to 15 Mbps N/A 1.5 to 15 Mbps HD Encoding Rate @ 4:2:2 (H.264) 1.5 to 20 Mbps 750 Kbps to 10 Mbps 1.5 to 20 Mbps HD Encoding Rate @ 4:2:0 (H.264) 1.5 to 20 Mbps 128 Kbps to 10 Mbps 1.5 to 20 Mbps SD Encoding Rate @ 4:2:2 (H.264) 1.5 to 15 Mbps 750 Kbps to 10 Mbps 1.5 to 20 Mbps SD Encoding Rate @ 4:2:0 (H.264) 1.5 to 15 Mbps 128 Kbps to 10 Mbps 1.5 to 15 Mbps AUDIO ENCODING 2- analog stereo/4-mono, AES/EBU (up to 4 pairs embedded in SDI) 2-analog stereo/4-mono, AES/ EBU (up to 2 pairs embedded in SDI) +8 dBm (avg.) @ 600 Ω bal. MPEG-2, H.264 HD/SD, 4:2:2/4:2:0 8.0 to 80 Mbps Audio Input (Analog) +8 dBm (avg.) @ 600 Ω bal. 1-analog stereo/2-mono, AES/EBU (AAC) (up to 2 pairs embedded in SDI) +8 dBm (avg.) @ 600 Ω bal. THD @ 1 KHz TT S/N (Signal to Noise) <.1% to +18 dBm max. >66 db RMS .3% to +18 dBm max. >65 db RMS <.1% to +18 dBm max. >66 db RMS Frequency Response .03-18 KHz ± 1.0 dB .03-12 KHz ± 1.0 dB .03-18 KHz ± 1.0 dB AES Input (digital) 1.0 V P/P @ 75 Ω unbalanced N/A 1.0 V P/P @ 75 Ω unbalanced www.vislink.com • [email protected] 10/14 ENG RD001096 Rev 7 © 2014 Vislink Group. All rights reserved. All other products or services referenced herein are identified by the trademarks or service marks of their respective companies or organisations. Note: Vislink reserves the right to change specifications without notice. Please contact your representative to confirm current specifications. LGR-1000 LiveGear Receiver The LGR-1000 is a receiver and playout device designed to receive AirStream or AirCam IP transmissions via the internet and provide an HD/ SD-SDI output. It can receive up to 4 AirStream, AirCam or NewStream transmissions simultaneously, providing a cost-effective means to receive live, remote Cellular Newsgathering content, which can then be viewed locally on a HD-SDI monitor or streamed to your favorite content delivery networks. There are no expensive receive site infrastructures to support as with traditional electronic newsgathering systems. The Vislink Hybrid Newsgathering Solution (outlined in the diagram below) combines cellular and microwave transmission technologies at the scene of the event, the LGR-1000 receiver unit at the broadcast studio for IP transmission, and the Video Media Server for push to edge devices, such as smartphones and tablets. Hybrid Bonded Video Solutions HD/SD-SDI Broadcast Studio Mobile Networks AirCam Max LiveGear Receiver Playout Unit IP Microwave or 3G/4G LTE IP Streamed to Website Live video AirStream AirCam Plus 3G/4G LTE or Wi-Fi Internet Video Media Server (optional) Edge Devices (PC, Smartphone, Tablet) Key Features Typical Applications ■■ Receives AirCam and AirStream IP transmissions ■■ Utilizes Public Infrastructure to Reduce Costs ■■ H.264 Video Quality with HD/SD-SDI Output ■■ Web Browser Remote Control ■■ Reception Integrity ■■ Cellular Newsgathering ■■ Rapid Deployment Newsgathering ■■ Special Interest Stories ■■ High School and College Sports ■■ Community Events SPECIFICATIONS VIDEO & AUDIO Interfaces HD/SD-SDI standard Resolution ■■1080p: 30 / 29.97 / 25 / 24 / 23.98 ■■1080i: 60 / 59.94 / 50 ■■720p: 60 / 59.94 / 50 / 24 / 23.98 ■■SD-SDI (480i) NTSC ■■SD-SDI (576i) PAL Formats HD, SD Decoding ■■H.264 AVC high profile 4.1 @ 256 kbps to 10 Mbps 4:2:0 (one video output standard) Digital Audio (Embedded) Dual IFB Audio 2 ea. 1/8” (3.5mm) RECEIVER LAN Supported via Ethernet ports remote control WAN RJ-45 ISP connectivity CONTROL/DISPLAYS Local User Interface Alphanumeric LCD display and 6-key button controller Advanced Remote User PC or laptop via LAN port (web browser interface) sets network control parameters PHYSICAL POWER HARD DISK STORAGE Dimensions (excl. connectors): ■■2 RU ■■19” w x 3.5” h x 17” d 48.3cm w x 8.9cm h x 43.2cm d 3-Prong IEC C14 ■■100-240 VAC Internal 320 GB Weight ■■17.3 lbs. (7.68 kg) www.vislink.com • [email protected] 9/14 ENG RD000480 Rev B © 2014 Vislink Group. All rights reserved. All other products or services referenced herein are identified by the trademarks or service marks of their respective companies or organisations. Note: Vislink reserves the right to change specifications without notice. Please contact your representative to confirm current specifications. EXCLUSIVE REPRESENTATIVE: PHASE ENGENHARIA Wireless Camera Systems PHASE Engenharia Ind. e Com. Ltda. Av. Olegário Maciel 231, Lojas 101 a 105 Barra da Tijuca | Rio de Janeiro, RJ | CEP 22 621 200 Tel +55.21.2493.0125 Av. Ibirapuera 2.907, Conj. B306 & 7 - Ed. Conv. Corp. Plaza – Torre C Indianópolis | São Paulo-SP | CEP 04029-200 Tel +55 11 3589-0125 [email protected] | www.phase.com.br