Preview only show first 10 pages with watermark. For full document please download

Vitobloc Bacnet/ip Gateway

   EMBED


Share

Transcript

Installation and operating instructions for contractors Vitobloc BACnet/IP Gateway with 0..20mA CHP unit accessory for VITOBLOC 200 50 to 530 kW el 5671 568-1 01/2015 Imprint NOTE The Vitobloc 200 CHP unit is not suitable for 60 Hz operation. It is therefore not available for the American and Canadian markets in particular. Note: This technical guide contains instructions for design engineers regarding the design, use and operating conditions of a CHP unit. For technical details please refer to the individual product catalogue, or for implementation planning, refer to the relevant technical unit description. For assistance with preliminary work during the project planning phase please contact our advisers. Subject to technical modifications. Continuing development may result in minor differences in the illustrations, operating steps and specifications. Updating the documentation Please let us know if you have any suggestions for improving our documentation, or if you have noticed any errors. Manufacturer’s address Viessmann Werke GmbH & Co.KG D-35107 Allendorf Telephone +49 (0)6452 70-0 Fax: +49 (0)6452 70-2780 www.viessmann.de 5671 568-1 Publication date: 01/2015 2 CHP unit accessory • Installation and operating instructions • BACnet/IP Gateway 0..20 mA • VITOBLOC 200 Table of contents Table of contents 1. Safety instructions ................................................................................................................ 4 2. Function ................................................................................................................ 5 3. Type ................................................................................................................ 5 4. Installation 4.1 4.2 4.3 4.4 4.5 5. BACnet / IP 5.1 Data points.......................................................................................12 5.2 Sensor assignment by type of CHP unit .........................................17 6. Commissioning ...............................................................................................................19 7. Maintenance ...............................................................................................................19 8. Disposal ...............................................................................................................19 5671 568-1 Mounting rail installation .................................................................. 6 Power supply.................................................................................... 8 Connecting the floating digital outputs ............................................. 9 Connecting the analogue outputs ....................................................10 Connecting the interfaces ................................................................11 VITOBLOC 200 CHP unit accessory • Installation and operating instructions • BACnet/IP Gateway 0..20 mA 3 Safety instructions 1 Safety instructions General These operating instructions contain general information that must be observed during installation, operation and maintenance. They must therefore be read by the installer and relevant qualified technician(s) prior to installation and commissioning. They must always be available at the system. Identification of safety instructions Failure to observe the safety instructions identified with this hazard symbol in these installation and operating instructions may result in risks to personnel. Caution Failure to observe the safety instructions identified with this symbol may result in risks for the device or the system and its functions. Note This symbol indicates information that will simplify work and ensure safe operation. Personnel qualifications The personnel designated to operate, maintain, inspect and install this equipment must have the appropriate qualifications for such work. The system operator is responsible for ensuring that this is the case. The safety instructions listed in these operating instructions must be observed, as must all applicable national regulations for accident prevention and any in-house working, operating or safety instructions issued by the operator. Risks from failure to observe the safety instructions Failure to observe the safety instructions may result in risks to personnel as well as to the environment and the system. LIABILITY The manufacturer will not accept any liability if these safety instructions are not observed. In particular, failure to observe these instructions may pose the following risks:  Failure of important system functions  Failure of prescribed methods of service and maintenance  Risks to personnel due to electrical and mechanical effects Electrical hazards Hazards arising from electrical current, e.g. as a result of removing safety covers, must be prevented. Safety instructions for maintenance, inspection and installation work The operator must ensure that all maintenance, inspection and installation work is carried out by authorised, qualified personnel who have used the operating instructions to acquaint themselves with the device. In principle, work may only be carried out on the device when the CHP unit is in an idle state and isolated from the power supply. Directly after work has been completed, all safety and protective equipment must be replaced and returned to full function. 5671 568-1 Safety instructions for the operator (risk analysis according to EN 12100) 4 CHP unit accessory • Installation and operating instructions • BACnet/IP Gateway 0..20 mA • VITOBLOC 200 Function Unauthorised modifications and production of spare parts Alterations or modifications to the device are only permissible following consultation with the manufacturer. Original spare parts and accessories authorised by the manufacturer are important to ensure safety. Use of other parts can void the liability for any resulting losses. Impermissible operation The device may only be used for the specified purpose. Any installation for an unspecified purpose is strictly prohibited. 2 Function General The device makes the data from a Vitobloc 200 CHP unit, which is read via the RS-232, available on the BACnet/IP. On-site connection (building management system) CHP unit Fig. 1 Schematic diagram of the device 3 Version The device is a compact unit for installation on a mounting rail. The mounting rail and fittings are included in the standard delivery of the device. 5671 568-1 Standard delivery VITOBLOC 200 CHP unit accessory • Installation and operating instructions • BACnet/IP Gateway 0..20 mA 5 Installation 4 Installation The device is always installed in a de-energised state with the wiring disconnected. General operating conditions In order to ensure fault-free operation of the device, the following conditions must be met and maintained:  Do not use in locations with aggravated operating conditions, such as corrosive steam or gas, dust formation or high ionising radiation  Permissible ambient temperature during operation 0 °C to +55 °C  Any installation position  Permissible ambient temperature during storage -25 °C to +85 °C  Permissible relative humidity during storage 95 %, without condensation Caution 4.1 An earth terminal is required on the profile rail. Mounting rail installation General  After removing the packaging, check the device for any transport damage.  Mount the top-hat rail on a clean surface and do not place it under stress. Caution Drilling swarf, screws and other foreign bodies must be prevented from entering the device.  Install it away from thoroughfares, but ensure there is still easy access.  Protect the device from direct insolation. Caution Installing the mounting rail Ensure there is adequate heat transfer. With unit types EM-18/36, EM-20/39, EM-50/81 and EM-70/115, the Vitobloc Gateway must be installed in an external terminal box. With larger CHP units that have ratings of 140 kWel or more, the mounting rail may be installed in the control panel of the CHP unit. Fig. 2 Gateway on the side panel of the panel door of the EM-238/363 CHP unit 5671 568-1 EM-140/207 CHP unit control panel Fig. 3 Gateway in the control 6 CHP unit accessory • Installation and operating instructions • BACnet/IP Gateway 0..20 mA • VITOBLOC 200 Installation Installing the Gateway  Pull the white tabs on the underside of the device downwards until they latch into place  Push the device onto the top-hat rail Caution Do not apply pressure to the display as this risks damaging it.  Push the white tabs back into their original positions  Once the device has been successfully installed, connect it according to the connection diagram, taking account of the safety instructions Removing the Gateway The Vitobloc Gateway is always removed in a de-energised state with the wiring disconnected. 5671 568-1  Pull the white tabs on the underside of the device downwards until they unlock  Pull out the orange tabs on the right-hand side of all the terminals in order to release them from the mounting rail  Grip the terminals simultaneously with your thumb and index finger at the top and bottom of the ribbed casing surfaces and pull from the mounting rail VITOBLOC 200 CHP unit accessory • Installation and operating instructions • BACnet/IP Gateway 0..20 mA 7 Installation 4.2 Power supply Before switching on the power supply, ensure that the components are clean and have been mounted in the correct order on the top-hat rail. Order from left to right:    CX 9000 KL 2794 KL 9010 Fig. 4 BACnet / IP Gateway Caution The device requires a voltage of 24 V DC (-15 %/+20 %), connected to an isolated power source protected by a max. 4 A fuse. Connecting the power supply Fig. 5 Power supply of the Vitobloc BACnet / IP Gateway 5671 568-1 The 24 V DC power supply for the Gateway is connected via the contacts labelled 24 V and 0 V as well as the + and - contacts. The spring-loaded terminals are designed for wires with a cross-section of between 0.08 and 2.5 mm² (stripped back by 8 to 9 mm). 8 CHP unit accessory • Installation and operating instructions • BACnet/IP Gateway 0..20 mA • VITOBLOC 200 Installation 4.3 Connecting the floating digital outputs KL 2794 The KL 2794 has 4 floating digital outputs. Output 1 switches terminals 1 and 2; output 2 terminals 5 and 6; output 3 terminals 3 and 4; and output 4 terminals 7 and 8 to continuity. The 4 outputs can be used freely (e.g. for calling the CHP unit) Signal-LED1 Signal-LED2 Signal-LED3 Signal-LED4 Output 1 Output 2 Output 1 Power contact + 24 V Output 2 Output 3 Power contact 0 V Output 4 Output 3 Output 4 Plan view Contact allocation 5671 568-1 Fig. 6 KL 2794 VITOBLOC 200 CHP unit accessory • Installation and operating instructions • BACnet/IP Gateway 0..20 mA 9 Installation 4.4 Connecting the analogue outputs KL 4414 The KL 4414 has four 0-20 mA outputs. These four outputs can be used freely (e.g. for the default output of the CHP unit) Run-LED1 Run-LED2 Run-LED3 Run-LED4 Output 1 Output 2 0V Power contact +24 V 0V Output 3 Power contact 0 V Output 4 0V 0V Plan view Contact allocation 5671 568-1 Fig. 7 KL 4414 10 CHP unit accessory • Installation and operating instructions • BACnet/IP Gateway 0..20 mA • VITOBLOC 200 Installation 4.5 Connecting the interfaces RS232 interface The RS232 interface is marked COM1 and is connected with the RS232 interface of the CHP unit via the null modem cable provided. Connecting cable between CHP unit and Gateway CHP unit Sub-D 9-pole socket GATEWAY Sub-D 9-pole socket 2: RxD 3: TxD 3: TxD 2: RxD 5: GND 5: GND Tab. 1 Connecting cable between CHP unit and Gateway Note Ethernet interface Cable to RS232 standard. The CHP unit data is supplied to the BACnet / IP via the Ethernet interface. The device has 2 RJ-45 Ethernet ports, designated X001 and X002. The two ports behave like a switch. Thus the Ethernet cable can be routed further to an additional device. A commercially available Ethernet cable can be used to make the connection (4x2 Category 5 twisted pair copper cable – max. cable length 100 m). The following IP settings are factory-set: IP address: 192.168.4.78 Subnet mask: 255.255.255.0 To change the IP settings, the "cerhost" program is required; this can be downloaded from the Beckhoff website. Link to the latest version: ftp://ftp.beckhoff.com/Software/embPCControl/CE/Solutions/RemoteDisplay/CeRemDispHost.zip 5671 568-1 This is a remote desktop software program which enables the installed Windows Ce user interface to be operated. The network settings in Windows Ce are performed in exactly the same way as in Windows XP. VITOBLOC 200 CHP unit accessory • Installation and operating instructions • BACnet/IP Gateway 0..20 mA 11 BACnet / IP 5 BACnet / IP The Gateway makes all data points of the CHP unit's RS232 interface available on the BACnet / IP. Four floating digital outputs for switching purposes (e.g. for calling the CHP unit) are also provided. Data points Designation BACnet type Mode Multistate input 1: OFF 2: manual 3: auto Status Multistate input 1: OFF 2: ready 3: start 4. operation 5: fault Operating mode Multistate input 1: OFF 2: manual 3: mains substitute 4: --5: selection 100 % 6: set value 0-100 % Set_value_modulating_operation Analogue input Multistate input Fault Hours run Analogue input Minutes run Analogue input Starts Analogue input Maintenance interval Analogue input Unit lockout Analogue input Advance warning time Analogue input The first fault reported during a malfunction until all faults have been acknowledged again. Analogue input Indicates when the next service is due, expressed in hours run. (Next_service - hours run = number of hours run until next service) NiCrNi_A Analogue input *1 NiCrNi_B Analogue input *1 NiCrNi_C Analogue input *1 NiCrNi_D Analogue input *1 PT100_1 Analogue input *1 PT100_2 Analogue input *1 PT100_3 Analogue input *1 PT100_4 Analogue input *1 PT100_5 Analogue input *1 PT100_6 Analogue input *1 Next_service 12 Content / remark CHP unit accessory • Installation and operating instructions • BACnet/IP Gateway 0..20 mA • VITOBLOC 200 5671 568-1 5.1 BACnet / IP Designation BACnet type Content / remark Battery voltage Analogue input Oil pressure Analogue input Lambda probe voltage Analogue input Speed Analogue input Temperature_controller Analogue input Temperature_enabling Analogue input Mains_voltage_L1 Analogue input Mains_voltage_L2 Analogue input Mains_voltage_L3 Analogue input Gen._voltage_L1 Analogue input Gen._voltage_L2 Analogue input Gen._voltage_L3 Analogue input Gen._current_L1 Analogue input Gen._current_L2 Analogue input Gen._current_L3 Analogue input Mains_voltage_total Analogue input Generator_voltage_total Analogue input Gen._current_total Analogue input Output Analogue input Mains frequency Analogue input Gen._frequency Analogue input CosPhi Analogue input Communication fault Binary input Digital_output1 Binary output Freely usable floating digital output Digital_output2 Binary output Freely usable floating digital output Digital_output3 Binary output Freely usable floating digital output Digital_output4 Binary output Freely usable floating digital output Analogue_output1 Analogue output Freely usable 0-20 mA analogue output Analogue_output2 Analogue output Freely usable 0-20 mA analogue output Analogue_output3 Analogue output Freely usable 0-20 mA analogue output Analogue_output4 Analogue output Freely usable 0-20 mA analogue output *1 The temperatures for NiCrNi and PT 100 are assigned differently, depending on the unit type. (See chapter "Sensor assignment by type of CHP unit") 5671 568-1 Tab. 2 BACnet data point list VITOBLOC 200 CHP unit accessory • Installation and operating instructions • BACnet/IP Gateway 0..20 mA 13 BACnet / IP 5.1.1 Multistate faults 14 Designation 1 No fault 2 Emergency stop 3 Min. oil level 4 Min. coolant pressure 5 Min. gas pressure 6 Safety temperature 7 Generator temperature 8 Silencer hood temperature 9 Fan fault 10 Coolant pump fault 11 Max. exhaust gas back pressure 12 Feed-in switch 13 External fault 14 Speed too high 15 Coolant temperature 16 Max. exhaust gas temperature 17 Min. exhaust gas temperature 18 Min. oil pressure 19 Max. gas pressure 20 Heating water pump fault 21 Start-up speed <50 rpm 22 Ignition speed 23 Speed window 24 Speed <1200 rpm 25 Start-up fault 26 Synchronisation fault 27 Speed <50 per pickup 28 Max. oil level 29 Max. temperature Pt100_2 30 Max. temperature Pt100_3 31 Max. output 32 Reverse output 33 Output controller fault 34 Lambda controller fault 35 Generator contactor fault 36 Ignition fault Comments CHP unit accessory • Installation and operating instructions • BACnet/IP Gateway 0..20 mA • VITOBLOC 200 5671 568-1 Value BACnet / IP 5671 568-1 Message Designation Comments 37 Oil pressure fault 38 Lambda start position 39 Knocking ON 40 Knocking OFF 41 Time switch deselection Disabled 42 Time switch enabling Disabled 43 Mains fault F < Disabled 44 Mains fault F > Disabled 45 Mains fault U+F <> Disabled 46 Min. knocking output 47 Max. knocking output 48 Mains coupling switch 49 Knocking fault 50 Mains OK Disabled 51 Mains fault Disabled 52 Temperature deselection Disabled 53 Temperature enabling Disabled 54 Service overdue 55 Safety shutdown 56 Engine not idle 57 Battery undervoltage 58 Generator undervoltage 59 Generator overvoltage 60 Generator overcurrent 61 Generator out-of-balance load 62 Tightness test fault 63 Mains circuit breaker fault 64 Sensor fault 65 Max. exhaust gas temperature A 66 Min. exhaust gas temperature A 67 Max. exhaust gas temperature B 68 Min. exhaust gas temperature B 69 Max. exhaust gas temperature C 70 Min. exhaust gas temperature C 71 Max. exhaust gas temperature D 72 Min. exhaust gas temperature D 73 Exhaust gas temp. differential A/B VITOBLOC 200 CHP unit accessory • Installation and operating instructions • BACnet/IP Gateway 0..20 mA 15 BACnet / IP Message Designation 74 Reserve 75 Max. return temp. PT100/2 76 Max. heating water temp. PT100/3 77 Max. engine oil temp. 78 Max. gas mixture temp. 79 Max. coolant mixture temp. Comments Tab. 3 Fault messages 5.1.2 EDE files 5671 568-1 The EDE files are available on request. 16 CHP unit accessory • Installation and operating instructions • BACnet/IP Gateway 0..20 mA • VITOBLOC 200 BACnet / IP 5.2 Sensor assignment by type of CHP unit Sensor NiCrNi / A EM-18/36 / EM-20/39 EM-50/81 EM-70/115 EM-140/207 Exhaust gas temperature Exhaust gas temperature Exhaust gas temperature Exhaust gas temperature NiCrNi / B -------------- -------------- -------------- -------------- NiCrNi / C -------------- -------------- -------------- -------------- NiCrNi / D -------------- -------------- -------------- -------------- PT 100 / 1 Coolant Coolant Coolant Coolant PT 100 / 2 Heating water return Heating water return Heating water return Heating water return PT 100 / 3 Heating water Heating water Heating water Heating water PT 100 / 4 -------------- -------------- -------------- -------------- PT 100 / 5 -------------- -------------- -------------- -------------- PT 100 / 6 -------------- -------------- -------------- -------------- EM-199/263 EM-199/293 EM-238/363 EM-363/498 Exhaust gas upstream of turbo Exhaust gas upstream of turbo Exhaust gas A Exhaust gas upstream of turbo A Exhaust gas B Exhaust gas upstream of turbo B Tab. 4 Sensor assignment overview Sensor NiCrNi / A NiCrNi / B Exhaust gas downstream Exhaust gas downstream of turbo of turbo NiCrNi / C Exhaust gas downstream Exhaust gas downstream Exhaust gas downstream of cat. of cat. of cat. Exhaust gas upstream of cat. NiCrNi / D -------------- -------------- -------------- Exhaust gas downstream of cat. PT 100 / 1 Coolant Coolant Coolant Coolant PT 100 / 2 Heating water return Heating water return Heating water return Heating water return PT 100 / 3 Heating water Heating water Heating water Heating water PT 100 / 4 Engine oil temperature Engine oil temperature Engine oil temperature Engine oil temperature PT 100 / 5 PT 100 / 6 Gas mixture temperature Gas mixture temperature Coolant mixture inlet Coolant mixture inlet -------------- Gas mixture temperature -------------- Coolant mixture inlet 5671 568-1 Tab. 5 Sensor assignment overview VITOBLOC 200 CHP unit accessory • Installation and operating instructions • BACnet/IP Gateway 0..20 mA 17 BACnet / IP Sensor EM-401/549 BM-36/66 BM-55/88 NiCrNi / A Exhaust gas upstream of turbo A Exhaust gas temperature Exhaust gas temperature NiCrNi / B Exhaust gas upstream of turbo B -------------- -------------- NiCrNi / C Exhaust gas upstream of cat. -------------- -------------- NiCrNi / D Exhaust gas downstream of cat. -------------- -------------- PT 100 / 1 Coolant Coolant Coolant PT 100 / 2 Heating water return Heating water return Heating water return PT 100 / 3 Heating water Heating water Heating water PT 100 / 4 Engine oil temperature -------------- -------------- PT 100 / 5 Gas mixture temperature -------------- -------------- PT 100 / 6 Coolant mixture inlet -------------- -------------- Tab. 6 Sensor assignment overview Sensor BM-190/238 BM-366/437 NiCrNi / A Exhaust gas upstream of turbo Exhaust gas upstream of turbo A NiCrNi / B Exhaust gas downstream of turbo Exhaust gas upstream of turbo B NiCrNi / C -------------- Exhaust gas downstream of turbo NiCrNi / D -------------- -------------- PT 100 / 1 Coolant Coolant PT 100 / 2 Heating water return Heating water return PT 100 / 3 Heating water Heating water PT 100 / 4 Engine oil temperature Engine oil temperature PT 100 / 5 Gas mixture temperature Gas mixture temperature PT 100 / 6 Coolant mixture inlet Coolant mixture inlet 5671 568-1 Tab. 7 Sensor assignment overview 18 CHP unit accessory • Installation and operating instructions • BACnet/IP Gateway 0..20 mA • VITOBLOC 200 Commissioning 6 Commissioning The device is commissioned as part of the general commissioning of the CHP plant or, in the case of retrofitting, by the CHP unit manufacturer's technical service personnel. 7 Maintenance This accessory is maintenance-free. 8 Disposal 5671 568-1 This product and its components must be disposed of in an environmentally responsible manner. Use public or private waste disposal companies. VITOBLOC 200 CHP unit accessory • Installation and operating instructions • BACnet/IP Gateway 0..20 mA 19 Subject to technical modifications. Viessmann Werke GmbH & Co KG D-35107 Allendorf Telephone +49 (0)6452 70-0 Fax: +49 (0)6452 70-2780 www.viessmann.de 5671 568-1 20 Viessmann Limited Hortonwood 30, Telford Shropshire, TF1 7YP, GB Tel: +44 1952 675000 Fax: +44 1952 675040 E-mail: [email protected]