Preview only show first 10 pages with watermark. For full document please download

Vm110p Submittal

   EMBED


Share

Transcript

VM110P SUBMITTAL Section 1 – General Specifications Section 2 – Product Dimensions Section 3 – Field Wiring THE FUTURE OF HOME HEATING NY THERMAL INC. Project Name: _______________________________________________________ Date: ________________________ Location: ________________________________________________________________________________________ Engineer: ________________________________________________________________________________________ Contractor: __________________________________________________________ Rep: ________________________ 1 – GENERAL SPECIFICATIONS Product Features: Factory Supplied Items VM110P SA240-S43932 Stainless Steel Heat Exchanger ASME “H” stamped boiler, designed and constructed in compliance with the ASME Boiler and Pressure Vessel Code Section IV Maximum operating pressure 30 psi [206.8 kPa] Modulating burner, 6.5 turndown ratio Direct Spark Ignition Built-in Tank Sensor Wall (standard) or floor mounting (w/ opt. kit, NTI part # 84624) Zero clearance to combustibles 110 MBH [110,000 BTU] Field conversion from Natural Gas (factory) to Propane Optional Sidewall vent kits Vents with PVC/CPVC/PP/SS Built-in diverter valve Built-in 3 speed circulator Built-in 16 gallon indirect water heater 120VAC outlet for condensate pump On/Off switch Vertical Firetube Boiler Indirect Tank 10K thermistor outdoor sensor 150PSI [1034 kPa] ASME Temperature/Pressure Relief Valve 30PSI [206.8 kPa] ASME Relief Valve 60PSI [413.7 kPa] Pressure Gauge Low-loss Header Condensate Trap Control Features Integral microprocessor safety control Domestic Hot Water Priority Outdoor Reset Warm weather shut down Freeze protection Cascade up to 16 VM110T series boilers 3 Circulator outputs Outdoor reset temperature boost Service reminder Adjustable pump post purge Run time accumulation Night setback option Lockout and error history Circulator Low-loss Header NY Thermal Inc. NY Thermal Inc. 30 Stonegate Drive, Saint John, NB E2H 0A4 Canada 2014-07-14 Rev. 0 Technical Service: 1-800-688-2575 Fax: 1-506-432-1135 Web: http:// www.nythermal.com NY Thermal Inc. reserves the right to change these specifications without notice . VM110P SUBMITTAL Section 1 – General Specifications Section 2 – Product Dimensions Section 3 – Field Wiring THE FUTURE OF HOME HEATING NY THERMAL INC. Model Specifications Water Conn. Model NPT, in. VM110P Gas Connection NPT, in. Vent/Air-Intake Pipe Diameter in. ½ (Male) 2 or 3 1 (Sweat) Vent/ Air-Inlet Max. Length, Ft. 2 in. Venting Approx. Wt. w/Water lb. 3 in. Venting 100 150 275 100 Heating Specifications Model Input Min BTU/hr Max BTU/hr Heating Capacity BTU/hr AFUE % VM110P 17,000 110,000 101,000 95 NET I=B=R Rating BTU/hr 88,000 Domestic Hot Water Specifications 1st Hour Rating* (GPH) Continuous Rating* (GPH) 218 205 Domestic Inlet / Outlet 3/4" Domestic Capacity (Gal.) 16 *Domestic performance based on average water temperature of 108ºF at mixing valve outlet and 50ºF inlet Performance Specifications VM110P Performance 120 0.1 Delta T curve 0.08 100 Head loss curve 80 0.06 60 0.04 40 0.02 20 0 0 2 3 4 5 6 7 8 Flow (USGPM) 9 10 11 Temperature (ºF) Head Loss (ft.) 0.12 12 * Head loss values calculated for factory supplied Low-Loss Header. NY Thermal Inc. NY Thermal Inc. 30 Stonegate Drive, Saint John, NB E2H 0A4 Canada 2014-07-14 Rev. 0 Technical Service: 1-800-688-2575 Fax: 1-506-432-1135 Web: http:// www.nythermal.com NY Thermal Inc. reserves the right to change these specifications without notice . VM110P SUBMITTAL Section 1 – General Specifications Section 2 – Product Dimensions Section 3 – Field Wiring THE FUTURE OF HOME HEATING NY THERMAL INC. 2 – PRODUCT DIMENSIONS [IN.] TOP VIEW BOTTOM VIEW FRONT VIEW RIGHT VIEW RECOMMENDED CLEARANCES [IN.] Front 36 Top 24 Sides 12 Back 0 Bottom 24 NY Thermal Inc. NY Thermal Inc. 30 Stonegate Drive, Saint John, NB E2H 0A4 Canada 2014-07-14 Rev. 0 Technical Service: 1-800-688-2575 Fax: 1-506-432-1135 Web: http:// www.nythermal.com NY Thermal Inc. reserves the right to change these specifications without notice Flue Pipe 1 . VM110P SUBMITTAL Section 1 – General Specifications Section 2 – Product Dimensions Section 3 – Field Wiring THE FUTURE OF HOME HEATING NY THERMAL INC. 3 -- FIELD WIRING EXT. LIMIT 120V DHW PUMP CH PUMP BOILER PUMP SYSTEM SENSOR CASCADE 2-16 BOILERS / BMS INTERFACE MODULE 9 1 ARGUS LINK - EXT. LIM 10 2 ARGUS LINK + DHW PUMP | PUMPE DHW 11 3 COMMON CH PUMP | PUMPE CH 12 4 SYSTEM | SYSTEME BOILER PUMP | PUMPE PRIMAIRE 13 5 OUTDOOR | EXTERIEUR L2 NEUTRAL | NEUTRLE L2 14 6 DHW | ECD AQUASTAT L2 NEUTRAL | NEUTRLE L2 15 7 THERMOSTAT L1 120VAC 16 8 THERMOSTAT GROUND OUTDOOR DHW DEMAND SENSOR SWITCH/SENSOR THERMOSTAT / ZONE END SWITCH SERVICE SWITCH [FIELD SUPPLIED] 120V/1P/60HZ 15A FUSED POWER SUPPLY NY Thermal Inc. NY Thermal Inc. 30 Stonegate Drive, Saint John, NB E2H 0A4 Canada 2014-07-14 Rev. 0 Technical Service: 1-800-688-2575 Fax: 1-506-432-1135 Web: http:// www.nythermal.com NY Thermal Inc. reserves the right to change these specifications without notice . SENSOR | SONDE EXT. LIM