Preview only show first 10 pages with watermark. For full document please download

Voltage Variable Attenuator

   EMBED


Share

Transcript

Surface Mount Voltage Variable Attenuator VACC-09+ 50Ω 600 to 1200 MHz Maximum Ratings Features Operating Temperature -45°C to 85°C Storage Temperature -55°C to 100°C Absolute Max. Control Current 10mA Absolute Max. RF Input Level +15 dBm • frequency range, 600-1200 MHz • IP3, 48 dBm typ. • minimum current at min. attenuation • low insertion loss • protected by US patent 7,030,713 CASE STYLE: GF995 Permanent damage may occur if any of these limits are exceeded. Pin Connections RF IN 2 V CONTROL 1 8 V CONTROL 2 4 RF OUT 6 GROUND Applications +RoHS Compliant • variable gain amplifier • feed forward amps • ALC circuits The +Suffix identifies RoHS Compliance. See our web site for RoHS Compliance methodologies and qualifications 1,3,5,7 Electrical Specifications Equivalent schematic of DUT 2 6 8 4 FREQ (MHz) Min. Max. INSERTION LOSS (dB) 0V control voltage Typ. Max. 600-1200 1.0 ATTENUATION (dB) 2.2 IP3* (dBm) Typ. Min. Typ. Min. 25 20 48 40 RETURN LOSS (dB) Input Output Typ. Typ. 20 CONTROL VOLTAGE** (V) 20 0-6 * Input IP3 tested with two tones separated by 1 MHz at 7 dBm each and 0V control voltage. ** Using recommended control port biasing. VACC-09+ ATTENUATION Vs. FREQUENCY Vs. CONTROL VOLTAGE Outline Drawing ATTENUATION(dB) 60 50 40 30 20 10 0 600 PCB Land Pattern 700 800 900 1000 1100 1200 FREQUENCY(MHz) 0V 0.5V 0.6V 0.7V 0.8V 0.9V 1V 1.1V 1.128V VACC-09+ TYPICAL ATTENUATION AT 900MHz 40 ATTENUATION(dB) 35 Suggested Layout, Tolerance to be within ±.002 Outline Dimensions ( inch mm ) A B C (Max) D E F G H J .150 .150 .065 .008 .036 .018 .062 .028 .022 3.81 3.81 1.65 0.20 0.91 0.46 1.57 0.71 0.56 K L M N P Q R S T 30 25 20 15 10 5 WT. .017 .014 .036 .018 .062 .028 .037 .017 .014 GRAM 0.43 0.36 0.91 0.46 1.57 0.71 0.94 0.43 0.36 .06 0 0 1 2 3 4 5 6 CONTROL VOLTAGE (V) Notes A. Performance and quality attributes and conditions not expressly stated in this specification document are intended to be excluded and do not form a part of this specification document. B. Electrical specifications and performance data contained in this specification document are based on Mini-Circuit’s applicable established test performance criteria and measurement instructions. C. The parts covered by this specification document are subject to Mini-Circuits standard limited warranty and terms and conditions (collectively, “Standard Terms”); Purchasers of this part are entitled to the rights and benefits contained therein. For a full statement of the Standard Terms and the exclusive rights and remedies thereunder, please visit Mini-Circuits’ website at www.minicircuits.com/MCLStore/terms.jsp Mini-Circuits ® www.minicircuits.com P.O. Box 350166, Brooklyn, NY 11235-0003 (718) 934-4500 [email protected] REV. C M151108 VACC-09+ EDB-040303 BCELL/RS/CP 161211 Page 1 of 3 VACC-09+ Performance Curves Demo Board MCL P/N: TB-250 Suggested PCB Layout (PL-148) Recommended control port biasing configuration R1 C1 C3 8 2 RF IN DUT 6 RF OUT DC BLOCK DC BLOCK 4 R2 C4 V CONTROL C2 R1, R2: 2K OHM CHIP RESISTOR (0402, AS CLOSE AS POSSIBLE TO THE DEVICE) C1, C2: 0.01 UF CHIP CAPACITOR (0603) C3 C4: 6.8 PF CHIP CAPACITOR (0603) VACC-09+ OUTPUT RETURN LOSS Vs. FREQUENCY Vs. CONTROL VOLTAGE VACC-09+ INPUT RETURN LOSS Vs. FREQUENCY Vs. CONTROL VOLTAGE 45 55 RETURN LOSS(dB) RETURN LOSS(dB) 50 45 40 35 30 25 20 40 35 30 25 20 15 15 600 700 800 900 1000 1100 1200 600 700 800 0V 0.5V 0.6V 0.7V 0.8V 900 1000 1100 1200 FREQUENCY(MHz) FREQUENCY(MHz) 0.9V 1V 1.1V 0V 0.5V 0.6V 0.7V 0.8V 0.9V 1V 1.1V Notes A. Performance and quality attributes and conditions not expressly stated in this specification document are intended to be excluded and do not form a part of this specification document. B. Electrical specifications and performance data contained in this specification document are based on Mini-Circuit’s applicable established test performance criteria and measurement instructions. C. The parts covered by this specification document are subject to Mini-Circuits standard limited warranty and terms and conditions (collectively, “Standard Terms”); Purchasers of this part are entitled to the rights and benefits contained therein. For a full statement of the Standard Terms and the exclusive rights and remedies thereunder, please visit Mini-Circuits’ website at www.minicircuits.com/MCLStore/terms.jsp Mini-Circuits ® www.minicircuits.com P.O. Box 350166, Brooklyn, NY 11235-0003 (718) 934-4500 [email protected] Page 2 of 3 VACC-09+ Performance Curves VACC-09+ IP3 Vs. CONTROL VOLTAGE Vs. FREQUENCY @ 25°C -10 60 -20 50 -30 40 IP3(dBm) INSERTION LOSS(dB) VACC-09+ INSERTION LOSS Vs. INPUT POWER @ 900MHz -40 -50 30 20 10 -60 0 -70 0 5 10 15 INPUT POWER(dBm) 20 0 25 1V 1.05V 1.1V 1.15V 1.2 1.25 1.3 1.35 1.4 1.45 1.5 1.55V 1.6V 1.65V 0.2 0.4 0.6 0.8 1 1.2 CONTROL VOLTAGE(V) IP3 @ 600MHz IP3 @ 900MHz IP3 @ 1200MHz VACC-09+ IP3 Vs. CONTROL VOLTAGE Vs. FREQUENCY @ -45°C VACC-09+ IP3 Vs. CONTROL VOLTAGE Vs. FREQUENCY @ 85°C 50 60 45 40 35 40 IP3(dBm) IP3(dBm) 50 30 20 30 25 20 15 10 10 5 0 0 0 0.2 0.4 0.6 0.8 1 0 1.2 0.2 0.4 IP3 @ 600MHz IP3 @ 900MHz 0.6 0.8 1 1.2 CONTROL VOLTAGE(V) CONTROL VOLTAGE(V) IP3 @ 600MHz IP3 @ 1200MHz VACC-09+ PHASE SHIFT Vs. FREQUENCY Vs. CONTROL VOLTAGE 600-900MHz (WITH RELATION TO 0V CONTROL VOLTAGE) IP3 @ 900MHz IP3 @ 1200MHz VACC-09+ PHASE SHIFT Vs. FREQUENCY Vs. CONTROL VOLTAGE 900-1200MHz (WITH RELATION TO 0V CONTROL VOLTAGE) 4.5 5 PHASE SHIFT(DEG.) PHASE SHIFT(DEG.) 4 3.5 3 2.5 2 1.5 1 0 -5 -10 -15 0.5 -20 0 600 650 700 750 800 850 900 900 950 1000 0.5V 0.6V 0.7V 0.8V 1050 1100 1150 1200 FREQUENCY(MHz) FREQUENCY(MHz) 0.9V 0.5V 1V 0.6V 0.7V 0.8V 0.9V 1V Notes A. Performance and quality attributes and conditions not expressly stated in this specification document are intended to be excluded and do not form a part of this specification document. B. Electrical specifications and performance data contained in this specification document are based on Mini-Circuit’s applicable established test performance criteria and measurement instructions. C. The parts covered by this specification document are subject to Mini-Circuits standard limited warranty and terms and conditions (collectively, “Standard Terms”); Purchasers of this part are entitled to the rights and benefits contained therein. For a full statement of the Standard Terms and the exclusive rights and remedies thereunder, please visit Mini-Circuits’ website at www.minicircuits.com/MCLStore/terms.jsp Mini-Circuits ® www.minicircuits.com P.O. Box 350166, Brooklyn, NY 11235-0003 (718) 934-4500 [email protected] Page 3 of 3