Preview only show first 10 pages with watermark. For full document please download

Vr 414 610 Stainless Steel Width 15" (38 Cm) Included Accessories

   EMBED


Share

Transcript

Vario 400 series electric grill VR 414 VR 414 610 Stainless steel Width 15" (38 cm) Included accessories 2 cast-iron grills 1 lava stone 1 cleaning brush 1 grease collecting insert 1 cast-iron griddle, half size Installation accessories In combination of several Vario cooktops or VL 414 downdraft, connecting strips must be used. Choose respective VA 420 strip from one of the below, depending on type of installation. VA 420 010 Connection strip for surface-mount installation without appliance cover. VA 420 011 Connection strip for surface-mount installation with appliance cover. VA 420 000 Connection strip for flush installation without appliance cover. VA 420 001 Connection strip for flush installation with appliance cover. VA 440 010 Stainless steel cover with mounting strip. VA 450 400 Stainless steel adjustment strip, width 15". Necessary accessory in a combination of 15" Varios with at least one appliance cover to compensate for the appliance depth. Optional accessories LV 030 000 Lava stones for refilling. VA 461 000 Cast-iron griddle, enameled, half size For Vario electric grill 400 series. For simultaneous searing and grilling on two separate surfaces. VA 461 001 Cast-iron griddle, enameled, full size For Vario electric grill 400 series. For searing large quantities on one surface. –– 2  zones, independently controlled –– Half size cast-iron griddle included for simultaneous searing and grilling on two separate surfaces –– Open cast-iron grill, lava stones –– Solid stainless steel control knobs –– Precision-crafted ⅛-inch stainless steel frame –– For surface-mount installation with a visible edge or for flush installation –– Can be perfectly combined with other Vario 400 series products Operation Control knobs with illuminated ring, cooking zone and output level markings. Electronic control in 12 output levels. Features Cooktop, lavastone container and grease drip tray are made from stainless steel. 2 independently controlled heating elements (1,500 W), front and rear. Two-part cast-iron grill. Safety Safety shut-off. Planning notes Depending on the type of installation —  surface-/ or flush-mounted, with or without cover — the specific location of the control knob positions may vary. When using the appliance cover VA 440 or adjustment strip VA 450 additional space for cut-out depth needs to be considered. In a combination of Vario cooktops with at least one appliance cover, the adjustment strip VA 450 is required. In a combination of several Vario 400 series cooktops a connection strip must be used. Depending on the type of installation — surface-/ or flushmounted, with or without cover — the respective VA 420 connecting strip must be used. For flush installation the edge height in the cut-out needs to be at least ½" and for surface-mount ⅜". Ensure a continuous cut surface of 90°. The weight capacity and stability, especially in case of thin counter­tops, must be supported using suitable substructures. Take the appliance weight and additional loads into account. Flush installation is possible in countertops made of stone, synthetics or solid wood. Heat resistance and watertight sealing of the edges must be observed. For other materials, please consult with your countertop manufacturer. The groove must be continuous and even, so that uniform placing of the appliance on the gasket is ensured. Do not use discontinuous lining. The joint width may vary due to size tolerances of the combinations and of the countertop cut-out. If installing several Vario products in individual cut-outs allow for a minimum distance of 2" between the cooktops. Built-in control panel can be inte­grated in the bottom cabinet at drawer level. Front panel thickness ⅝" – 1". The adjacent drawing “Installation of the control knobs” must be observed if the panel is more than 1" thick (there must be a recess at the rear for proper control module installation). Above the countertop minimum clearance of 21" from adjacent heat-sensitive cabinets or contact 1" surfaces must be observed or thermal insulation must be installed. Appliance can be snapped into the countertop from above. Please read additional planning notes on pages 82 – 87. Rating Total rating: 3.0 kW. Total Amps: 15 A. 208/220–240V / 60 Hz Plan for a 70" connecting cable without plug (hardwire required). Surface-mount Installation 1415/ 16" (380) 1 Flush-mount Installation 1415/ 16" (380) 201/ 2" (520) *211/ 16" (*535) / 8" (3) **3 / 8" (92) 5 201/ 2" (520) *211/ 16" (*535) 3 **3 / 4" (95) / 8" (3) R / 8" (R 3) 193/ 8"±1/ 16" (492±2) *201/ 4"+1/ 16" (*515+2) 90° min. 13/ 8" (35) 193/ 8"±1/ 16" (492±2) *201/ 4"+1/ 16" (*515+2) min. 1 / 8" (35) dia. 13/ 8" (35) 815/ 16" dia. 21/ 8" (227) (60) 1 min. 4 / 8" (105) max. 63/ 8" (162) 39/ 16" (90) 3" (76) 143/ 16"±1/ 16" (360±2) 90° 51/ 2" (140) R 1/ 8" (3) 2011/ 16"+1/ 16" (526+2) *211/ 4"+1/ 16" (*541+2) 3 70" (1.8 m) min. 2" (50) R 3/ 16" 1 (5+1) / 8"-0.5 (3.5 ) 1 1 70" (1.8 m) min. 2" (50) dia. 13/ 8" (35) 815/ 16" dia. 21/ 8" (227) (60) min. 41/ 4" (109) max. 61/ 2" (166) 39/ 16" (90) 143/ 16"±1/ 16" (360±2) 11" (280) 3" (76) 51/ 2" (140) 11" (280) 153/ 16"+1/ 16" (386+2) *knob with installation, appliance cover or adjustment installation strip. Control surface-mounted * With appliance cover or adjustment See separate planning notes. strip. See separate planning notes on page 87. ** 4 ⅛" (105) in the area of the cable clip (right, center). 1 ** 4 / 8" (105 mm) in the area of the cable clip (right, center). Installation of the control knob; surface-mount installation 41/ 8"-63/ 8" (105-162) min. 3/ 16" (5) ø 13/ 8" (35) 3 min. / 16" (5) 31/ 8"x123/ 16" (80x310) Control knob installation, flush-mounted installation * with appliance or adjustment strip. * With appliance covercover or adjustment strip. See separate planning notes on page 87. ** 4 ¼"See (108)separate in the area of the cable clip (right, center). planning notes. ** 41/ 4" (108 mm) in the area of the cable clip (right, center). Installation of the control knob; flush-mount installation 41/ 4"-61/ 2" (109-166) 41/ 8"-63/ 8" (105-162) min. / 16" (5) min. 3/ 16" (5) 31/ 8"x123/ 16" (80x310) ø 13/ 8" (35) ø 13/ 8" (35) 41/ 4"-61/ 2" (109-166) 3 ø 13/ 8" (35) D =1" (26) D =1" (26) 5 / 8"-1" (16-26) 5 / 8"-1" (16-26) D >1" (26) D >1" (26) View from above View from above 153/ 16"+1/ 16" (386+2) 143/ 16"±1/ 16" (360±2) 2011/ 16"+1/ 16" (526+2) *211/ 4"+1/ 16" 3 ±1 (*541+2) 19 / 8" ±2/ 16" (492 ) *201/ 4"+1/ 16" (*515+2) R 1/ 8" (R 3) R 3/ 16" (R 5+1) * with appliance cover or adjustment strip (observe front and rear asymmetrical assembly. See separate notes “assembly with appliance cover/adjustment strip” on page 87). * with appliance cover or adjustment bar Longitudinal section (observe front and rear asymmetrical assembly, Longitudinal section see separate notes with 1415/"assembly 16" / 8" appliance cover/adjustment bar"). 1/ 8" (380) +1 (3 ) (3+1) 1 fill with silicone 1 / 8" (3,5-0,5) 1 1 / 2" (13) 143/ 16"±1/ 16" (360±2) / 2" (13) 153/ 16"+1/ 16" (386+2) Cross-section Cross-section 1 / 8" (3+1) 201/ 2" (520) 1 / 8" (3+1) fill with silicone 1 / 8" (3.5-0.5) 11 / 16" (17) Numbers indicated inside parenthesis (  ) = mm 11 / 16" 193/ 8"±1/ 16" (17) (492±2) 2011/ 16"+1/ 16" (526+2) When installing with appliance cover or adjustment strip, pay attention to the deeper cut-out and the front and rear groove width.