Transcript
P1825-P1829-E
Best
08.9.4 1:37 PM
1
Page 1828
Pneumatics
Transmitters
Effective area Number of ports (mm2) Relay valve P. 1900
VR4151 7
5
VR1210
7
3
VR1220
15
3
VR1210F
7.3
3
VR1220F
15.2
3
AND valve P. 1905
VR1211F
2.6
3
Time delay valve P. 1907
VR2110
2.5
3
Dimensions Side piping: 30 x 53 x 91 Bottom piping: 30 x 48 x 91
Shuttle valve P. 1902 Dimensions VR1210: 17.2 x 38 x 29 VR1220: 21.2 x 50 x 38
Shuttle valve P. 1903
Function
Metal Spool
VR4152
Dimensions 71.6 x 44.8
Dimensions 70 x 68 x 66
Pneumatic-electric relay P. 1909
VR3200
Dimensions VR3200: 17 x 49 x 71 VR3201: 25 x 86 x 89
VR3201
Pneumatic indicator P. 1911
VR3100
Dimensions ø26 x 66
Miniature pneumatic indicator P.1911
VR3110
Dimensions ø12 x 17
1828 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
RoHS-VR.qxd
10.7.26 5:08 PM
Page 1
Transmitters: Relay Valve
RoHS
Series VR4151/4152 Specifications Appropriate output sequences are affected according to the signal received from the mechanical valve. It is equivalent to the auxiliary relay of an electrical system.
Fluid Operating pressure Pilot pressure Ambient and fluid temperature Effective area Port size
Air 0 to 1.0 MPa 0.15 to 1.0 MPa –5 to 60°C (No freezing) 1 8 : 7mm2 18
Side ported 350 g Bottom ported 300 g Not required (Use turbine oil Class 1 ISO VG32, if lubricated.)
Mass Lubrication
Model Function
Sub-plate
Model
W/o sub-plate Single pilot
JIS Symbol
W/ sub-plate Side piping W/ sub-plate Bottom piping W/o sub-plate
Double pilot VR4151
Indicator
VR4151-00-0 VR4151-00-1 VR4151-01A-0 VR4151-01A-1 VR4151-01B-0 VR4151-01B-1 VR4152-00-0 VR4152-00-1 VR4152-01A-0 VR4152-01A-1 VR4152-01B-0 VR4152-01B-1
W/ sub-plate Side piping W/ sub-plate Bottom piping
Construction
VR4152
VR4151
VR4152
Precautions Be sure to read before handling. Refer to front matters 58 and 59 for Safety Instructions and pages 3 to 7 for 3/4/5 Port Solenoid Valve Precautions.
Environment
Caution Operate the valve in an area in which the vibration does not exceed 5 G. Vibrations could cause the valve to malfunction.
Component Parts No. 1 2 3 4 5 6 7
Description Valve Sub-plate Pilot cover Spool Sleeve Detent assembly Piston cover
Material ADC ZDC ADC Stainless steel Stainless steel Brass
No. 8 9 10 11 12 13 14
Description Manual button Piston Spring Spring Gasket Gasket O-ring
Material PE PE Steel Stainless steel NBR NBR NBR
1900 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
P1889-P1944-E.qxd
08.9.2 8:12 PM
Page 1901
Transmitters: Relay Valve
Series VR4151/4152
How to Order
VR41 5 1
01 A
1 Indicator light 0 1
No Yes
Sub-plate A B
Side piping Bottom piping
Port size 00 01 N01 F01
W/o sub-plate Rc 1 8 NPT 1 8 G1 8
Number of pilot ports Single pilot Double pilot
1 2
Number of ports 5
5 port
Dimensions
Stroke
Bottom ported Stroke
Side ported Indicator light
Indicator light
Manual override (Button diameter ø3.5)
Manual override (Button diameter ø3.5)
2x6.5 mounting hole Port size 7 x 1/8
mounting hole
Port size mounting hole
VM VMG VR VH
1901 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
RoHS-VR.qxd
10.7.26 5:08 PM
Page 2
Transmitters: Shuttle Valve
RoHS
Series VR1210/1220 Model/Specifications 3 ported check valve with one output and 2 pneumatic signal input ports. Output always supplied by high pressure inlet.
VR1210-01
Model Max. operating pressure Min. operating pressure Min. pressure differential Ambient and fluid temperature Effective area Port size Mass
VR1220-02
1.0 MPa 0.05 MPa 0.05 MPa –5 to 60°C (No freezing) 7mm2
15mm2
18
14
24 g
45 g
How to Order
VR12 1 0
01 Port size Applicable model 01 02
JIS Symbol
18 14
VR 1210 VR 1220
Thread type Nil N F
Rc NPT G
Body size 1 2
18 14
standard standard
Construction When right port has higher pressure
When left port has higher pressure
(High pressure side) (High pressure side)
(Low pressure side)
(Low pressure side)
Component Parts Material ADC Brass
Description No. Body 1 2 Valve seat
Note No. Description Platinum silver 3 Valve O-ring 4
Material Brass, NBR NBR
Note
Dimensions VR1210
VR1220 20
3 x 1/4
3 x 1/8
16
5.5 mounting hole
SMC
38
IN
17.2
6.6 mounting hole
IN
SMC
50
IN
38
16 29
16
OUT
IN
20
21
OUT
21.2
1902 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
RoHS-VR.qxd
10.7.26 5:08 PM
Page 3
Transmitters: Shuttle Valve with One-touch Fittings
Series VR1210F/1220F RoHS Model Relay valves for controlling pneumatic signal lines
Applicable tubing O.D. Metric size
Model
Inch size
3.2
4
6
8
10
쎲
쎲
쎲 쎲
쎲 쎲
쎲
VR1210F VR1220F
1/8"
5/32"
1/4"
5/16"
3/8"
쎲
쎲
쎲 쎲
쎲 쎲
쎲
Specifications 1.5 MPa
Proof pressure
The air of higher pressure side constantly flows to the OUT side. IN High pressure
Max. operating pressure
1.0 MPa
Min. operating pressure
0.05 MPa
Ambient and fluid temperature
–5 to 60°C (No freezing)
Applicable tubing material (1)
Nylon, Soft nylon, Polyurethane
Note 1) Use caution about the maximum operating pressure when soft nylon and polyurethane is used. (Refer to Best Pneumatics No. 6.) Note 2) Brass components are all electroless nickel plated as standard. (Copper-free and fluorine-free)
OUT IN Low pressure IN Low pressur OUT IN High pressure
JIS Symbol
Flow Rate and Effective Area VR1210F
Model
IN
OUT
VR1220F
ø3.2
ø4
ø6
ø8
ø6
ø8
ø10
ø1/8"
ø5/32"
ø1/4"
ø5/16"
ø1/4"
ø5/16"
ø3/8"
Flow rate l/min (ANR)
150
210
420
480
440
680
1000
Effective area (mm2)
2.3
3.2
6.4
7.3
6.7
10.4
15.2
Applicable Metric size tubing O.D. Inch size
Note) Flow rate is the value measured under a pressure of 0.5 MPa and a temperature of 20°C.
How to Order
VR 12 1 0 F
06 VM쏔
Body size 1 2
1/8 standard 1/4 standard
Shuttle valve With One-touch fittings
VMG
Applicable tubing O.D. Metric size Inch size 23 04 06 08 10
ø3.2 ∗ ø4 ø6 ø8 ø10
01 03 07 09 11
VR쏔
ø1/8" ø5/32" ø1/4" ø5/16" ø3/8"
VH쏔
∗ For ø3.2, use ø1/8" tubing.
1903 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
P1889-P1944-E.qxd
Series
08.9.2 8:12 PM
Page 1904
VR1210F/1220F
Example of Operating Circuit OR circuit • If either A or B is turned ON, cylinder is actuated.
Self-hold circuit
Interlock circuit
1. If A is turned ON, the output turns ON. 2. Even though A is turned OFF, the output remains in ON state. 3. If B is turned ON in 2. state, the output is turned OFF.
• When either A or B is turned ON, even though C turns ON, the output 3 will not be turned ON. • Only when both A and B are in OFF state, if C turns ON, the output 3 is turned ON.
Output Output 3
B Output 1
A A
B
Output 2
B
C
A
L5 M2
øD2
øD
3
Dimensions
Metric size: Light gray Inch size: Orange
IN
L3 L4
Blue
IN
L2
øD1
OUT
M1
M1
Applicable tubing O.D. ød
L1
Metric size: Light gray Inch size: Orange
Metric Size Model
VR1210F-23 VR1210F-04 VR1210F-06 VR1210F-08 VR1220F-06 VR1220F-08 VR1220F-10
L2
L3
L4
L5
M1
M2
Mass (g)
52
6.2
19.4
29.8
17.5
12.7
12.9
21.4
53
6
20.3
31.5
21.9
16.5
15.8
15.6
53.2
6.8
35.6
25.2
16.8
16.8
23.0
15.2
60.4
8.1
38.2
28.2
18.7
18.7
24.0
12.8
12.8
59
7.4
37.7
25.2
16.8
16.8
27.2
8
15.2
15.2
65
8.2
39.7
28.2
18.7
18.7
31.9
10
18.5
18.5
71.6
9.8
25.8
44.8
31
20.8
20.8
43.2
d
D1
D2
L1
L2
L3
L4
L5
M1
M2
Mass (g)
d
D1
D2
3.2
11.4
8.4
4
11
10.4
6
12.8
12.8
8
15.2
6
D3
14.8
19.8
L1
22.5 23.9
Inch Size Model
VR1210F-01 VR1210F-03 VR1210F-07 VR1210F-09 VR1220F-07 VR1220F-09 VR1220F-11
D3
1/8"
11.4
8.4
52
6.2
19.4
29.8
17.5
12.7
12.9
21.4
5/32"
11
10.4
53
6
20.3
31.5
21.9
16.5
15.8
15.6
1/4"
13.2
13.2
54.4
7.1
36.2
25.6
16.8
16.8
23.5
5/16"
15.2
15.2
60.4
8.1
38.2
28.2
18.7
18.7
24.0
1/4"
13.2
13.2
59
7.4
37.9
25.6
16.8
16.8
31.4
5/16"
15.2
15.2
65
8.2
39.7
28.2
18.7
18.7
31.9
3/8"
17.9
18.5
69.8
9.5
44.5
31
20.8
20.8
53.0
14.8
19.8
22.5 23.9 25.8
1904 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
RoHS-VR.qxd
10.7.26 5:08 PM
Page 4
Transmitters: AND Valve with One-touch Fittings
Series VR1211F
RoHS
Model Relay valves for controlling pneumatic signal lines
Applicable tubing O.D. Metric size
Model
VR1211F
Inch size
3.2
4
6
1/8"
5/32"
1/4"
쎲
쎲
쎲
쎲
쎲
쎲
Specifications 1.5 MPa
Proof pressure Max. operating pressure
1.0 MPa
Min. operating pressure
0.05 MPa
Ambient temperature and operating fluid temperature
Only when air is supplied to both P1 and P2 does air flow to the OUT side. When air pressure differs, pressure in the lower amount flows to the OUT side.
–5 to 60°C (No freezing)
Applicable tubing material (1)
Nylon, Soft nylon, Polyurethane
Note 1) Use caution about the maximum operating pressure when soft nylon and polyurethane is used. (Refer to Best Pneumatics No. 6.) Note 2) Brass components are all electroless nickel plated as standard. (Copper-free and fluorine-free)
IN P1
OUT IN P2
Flow Rate and Effective Area VR1211F
Model Applicable tubing O.D.
If air is supplied only to either P1 or P2, it does not flow to the OUT side.
IN
OUT
IN P1
Metric size
ø3.2
ø4
Inch size
ø6
–
ø1/8"
ø5/32"
–
ø1/4"
Flow rate l/min (ANR)
100
120
150
170
Effective area (mm2)
1.5
1.8
2.3
2.6
Note) Flow rate is the value measured under a pressure of 0.5 MPa and a temperature of 20°C. OUT IN P2
How to Order IN P1
VR 12 1 1 F
OUT
06 VM쏔
IN P2
VMG JIS Symbol
Body size 1
1/8 standard
AND valve
VR쏔
Applicable tubing O.D. Metric size Inch size 23 04 06
ø3.2 ∗ ø4 ø6
01 03 07
VH쏔
ø1/8" ø5/32" ø1/4"
∗ For ø3.2, use ø1/8" tubing.
With One-touch fittings
1905 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
P1889-P1944-E.qxd
Series
08.9.2 8:12 PM
Page 1906
VR1211F
Example of Operating Circuit Output 3
• If both A and B are turned ON, which are in different pressure conditions, both output 1 and 2 will turn ON • Only when output 1 and 2 are in the ON state, and C turns ON, will output 3 turn ON. • If either A or B is turned OFF, output 3 will not be turned ON, even if C is turned ON.
Output 2
Output 1
A
B
C
L5 M2
øD2
øD
3
Dimensions
Metric size: Light gray Inch size: Orange
IN
IN
L2
øD1
OUT
L3 L4
Blue
M1
M1
Applicable tubing O.D. ød
L1
Metric size: Light gray Inch size: Orange
Metric Size d
D1
3.2
11.4
4
11
10.4
6
12.8
12.8
Model
d
D1
D2
VR1211F-01 VR1211F-03 VR1211F-07
1/8"
11.4
5/32"
11
10.4
1/4"
13.2
13.2
Model
VR1211F-23 VR1211F-04 VR1211F-06
D2
D3
8.4
L2
L3
L4
L5
M1
M2
Mass (g)
6.2
25.7
36.1
17.5
12.7
12.9
26.4
26.6
37.8
21.9
16.5
15.8
20.8
28.8
41.9
25.2
16.8
16.8
25.0
L2
L3
L4
L5
M1
M2
Mass (g)
52
6.2
25.7
36.1
17.5
12.7
12.9
26.4
53
6.8
26.6
37.8
21.9
16.5
15.8
20.8
54.4
7.1
28.8
42.5
25.6
16.8
16.8
27.0
L1 52
14.8
53 53.2
6.8
Inch Size D3
8.4 14.8
L1
1906 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
RoHS-VR.qxd
10.7.26 5:08 PM
Page 5
Transmitters: Time Delay Valve
Series VR2110
RoHS
Model/Specifications Combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period.
VR2110-01
Model Supply pressure Signal pressure Time delay Repeatability Operating and fluid temperature Effective area Port size Mass
0 to 1.0 MPa 0.25 to 0.8 MPa 0.5 to 60 s ±10% F.S. –5 to 60°C (No freezing) 2.5 mm2 1 8
500 g
Construction Non-actuated Spare tank
JIS Symbol
Connecting port processing possible Tank
Input Signal (PIL) vs. Time Delay
Needle
Knob
Time delay (sec)
Actuated before time set
Signal pressure (MPa) Example)
is the point, which is set by the input signal pressure 0.25 MPa, with a delay time of 60 sec. With the same status, if the input signal pressure is increased to 0.8 MPa, the delay time varies to the point (≅ 40 sec).
Actuated after time set
Piping Length vs. Release Time
VM쏔
Signal/Supply pressure Signal/Supply pressure
VMG
Release time (sec)
VM1
VR쏔 VM2
VH쏔
Component Parts Piping length (m) If the input signal (PIL) is turned OFF, the release time of the time delay valve changes depending upon the effective area of the valve and the length of piping. Please refer to the above graph for the standard values.
No. 1 2 3 4
Description Body Piston Piston Needle
Note No. Material Platinum silver 5 ADC Brass, NBR Rubber lined 6 Brass, NBR Rubber lined 7 Brass 8
Description Spring Body Plunger Valve
Note Material Steel ZDC Platinum silver Stainless steel Brass, NBR Rubber lined
1907 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
P1889-P1944-E.qxd
08.9.2 8:12 PM
Page 1908
Series VR2110 How to Order
VR2110
01 Option X3
Secondary tank connection board Rc 1 4
X102
N.O. N.C. common type (With VM430)
Port size 01 N01 F01
Rc 1 8 NPT 1 8 G1 8
Dimensions Bracket mounted
Panel mounted 2 x ø6.5 hole Mounting screw M6 x 1 x 12
Rc 1/4 Spare tank connecting port processing possible
4 x M6 thread Bottom of bracket Knob side
Bracket side 4 x ø7 hole Bracket plate t = 2 Panel thickness t = 3 or less
Max. 74 Min. 70
Rc 1/8 signal pressure port 2 x M6 x 1.0 thread depth 8 Panel mounting screw
ø4 exhaust port Rc 1/8 output pressure port
1908 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
017-VR.qxd
10.12.27 1:20 PM
Page 1
Transmitters: Pneumatic-electric Relay
RoHS [Option]
Series VR3200/3201 Model/Specifications Pneumatic-electric relay converts pneumatic signal to electric relay.
Model Construction Weight Operating pressure Ambient and fluid temperature Contacts Port size Standard (CE-compliant)
VR3200-01 Open type 130 g
VR3201-01 Splashproof (IP44 equivalent) 260 g 0.1 to 1.0 MPa –5 to 60°C (No freezing) 1ab 18
EN60947-5-1:2004 Note)
Note) Voltage is up to 30 VDC. Voltage other than that will be inapplicable.
Microswitch Rating Non-inductive load (A) Light load Resistance load N.C. N.O. N.C. N.O. 15 15 3 1.5 15 15 2.5 1.25 15 15 3 1.5 15 15 3 1.5 6 6 3 1.5 0.5 0.5 0.5 0.5 0.25 0.25 0.25 0.25
Voltage
125 VAC 250 VAC 8 VDC 14 VDC 30 VDC 125 VDC 250 VDC
JIS Symbol
Inductive load (A) Inductive load Electric motor load N.C. N.O. N.C. N.O. 15 15 5 2.5 15 15 3 1.5 15 15 5 2.5 10 10 5 2.5 5 5 5 2.5 0.05 0.05 0.05 0.05 0.03 0.03 0.03 0.03
How to Order
VR320 0
01 CE-compliant Nil
Q
— CE-compliant
Port size 01 N01 F01
Precautions Be sure to read defore handling. Refer to front matters 58 and 59 for Safety Instructions and pages 3 to 7 for 3/4/5 Port Solenoid Valve Precautions.
Rc 1 8 NPT 1 8 G18
Construction 0 1
Open type Splashproof (IP44 equivalent)
Construction
VM쏔 VMG
Piping
Warning
VR쏔
When connecting a pipe fitting to the IN port, place the wrench over the hexagon portion of the lid. If the wrench is placed over the microswitch body, the neck of the microswitch could break.
VH쏔
Component Parts No. 1 2 3
Description Body Cap Piston
Material Brass Brass POM
Note
No. 4 5
Description Spring Microswitch
Material Stainless steel
Note Contacts 1 ab
1909 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
P1889-P1944-E.qxd
08.9.2 8:12 PM
Page 1910
Series VR3200/3201 Dimensions
VR3200
VR3201
2 x M4 x 45
G 1/2 Ridges min. 4
Terminal with solder 3 x M4 x 5.5 terminal thread (With cup washer)
Detail on microswitch terminals Detail on micro switch terminals
1910 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
RoHS-VR.qxd
10.7.26 5:08 PM
Page 7
Transmitters: Pneumatic Indicator
Transmitters: Miniature Pneumatic Indicator
Series VR3100
Series VR3110
RoHS Indicates the presence of pneumatic pressure. It is equivalent to the pilot lamp of an electrical system.
RoHS This is an ultra-compact air indicator light to monitor the presence of air pressure. It is equivalent to the pilot lamp of an electrical system. JIS symbol
JIS symbol
Model/Specifications
Model/Specifications
Model VR3100-01R VR3100-01G VR3100-01O Operating pressure 0.1 to 0.8 MPa Ambient and fluid temp. –5 to 60°C (No freezing) Frequency 100 c.p.m. or less Color of indicator Red Green Orange Port size Rc 1 8 Mass 40g
Construction
VR3110-01R
Model Color of indicator Operation Operating pressure Ambient and fluid temp. Frequency Port size Mass
VR3110-01G
Red
Green Piston style 0.15 to 1.0 MPa –5 to 60°C (No freezing) 300 c.p.m. or less R18 6g
Construction
Clear cover Piston (Red, green, orange) Piston (Red, green)
No. 1 2 3 4 5
Material Description Aluminum alloy Body Indicator window Acrylic POM Piston Spring Stainless steel Seal NBR
Note
Dimensions
No. 1 2 3 4 5
Description Body Piston A Plug Spring O-ring
Material Brass POM PE Stainless steel NBR
Note
Dimensions
VM쏔