Preview only show first 10 pages with watermark. For full document please download

Vr Series Mechanical Valve Transmitters

   EMBED


Share

Transcript

P1825-P1829-E Best 08.9.4 1:37 PM 1 Page 1828 Pneumatics Transmitters Effective area Number of ports (mm2) Relay valve P. 1900 VR4151 7 5 VR1210 7 3 VR1220 15 3 VR1210F 7.3 3 VR1220F 15.2 3 AND valve P. 1905 VR1211F 2.6 3 Time delay valve P. 1907 VR2110 2.5 3 Dimensions Side piping: 30 x 53 x 91 Bottom piping: 30 x 48 x 91 Shuttle valve P. 1902 Dimensions VR1210: 17.2 x 38 x 29 VR1220: 21.2 x 50 x 38 Shuttle valve P. 1903 Function Metal Spool VR4152 Dimensions 71.6 x 44.8 Dimensions 70 x 68 x 66 Pneumatic-electric relay P. 1909 VR3200 Dimensions VR3200: 17 x 49 x 71 VR3201: 25 x 86 x 89 VR3201 Pneumatic indicator P. 1911 VR3100 Dimensions ø26 x 66 Miniature pneumatic indicator P.1911 VR3110 Dimensions ø12 x 17 1828 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com RoHS-VR.qxd 10.7.26 5:08 PM Page 1 Transmitters: Relay Valve RoHS Series VR4151/4152 Specifications Appropriate output sequences are affected according to the signal received from the mechanical valve. It is equivalent to the auxiliary relay of an electrical system. Fluid Operating pressure Pilot pressure Ambient and fluid temperature Effective area Port size Air 0 to 1.0 MPa 0.15 to 1.0 MPa –5 to 60°C (No freezing) 1 8 : 7mm2 18 Side ported 350 g Bottom ported 300 g Not required (Use turbine oil Class 1 ISO VG32, if lubricated.) Mass Lubrication Model Function Sub-plate Model W/o sub-plate Single pilot JIS Symbol W/ sub-plate Side piping W/ sub-plate Bottom piping W/o sub-plate Double pilot VR4151 Indicator VR4151-00-0 VR4151-00-1 VR4151-01A-0 VR4151-01A-1 VR4151-01B-0 VR4151-01B-1 VR4152-00-0 VR4152-00-1 VR4152-01A-0 VR4152-01A-1 VR4152-01B-0 VR4152-01B-1 W/ sub-plate Side piping W/ sub-plate Bottom piping Construction VR4152 VR4151 VR4152 Precautions Be sure to read before handling. Refer to front matters 58 and 59 for Safety Instructions and pages 3 to 7 for 3/4/5 Port Solenoid Valve Precautions. Environment Caution Operate the valve in an area in which the vibration does not exceed 5 G. Vibrations could cause the valve to malfunction. Component Parts No. 1 2 3 4 5 6 7 Description Valve Sub-plate Pilot cover Spool Sleeve Detent assembly Piston cover Material ADC ZDC ADC Stainless steel Stainless steel Brass No. 8 9 10 11 12 13 14 Description Manual button Piston Spring Spring Gasket Gasket O-ring Material PE PE Steel Stainless steel NBR NBR NBR 1900 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com P1889-P1944-E.qxd 08.9.2 8:12 PM Page 1901 Transmitters: Relay Valve Series VR4151/4152 How to Order VR41 5 1 01 A 1 Indicator light 0 1 No Yes Sub-plate A B Side piping Bottom piping Port size 00 01 N01 F01 W/o sub-plate Rc 1 8 NPT 1 8 G1 8 Number of pilot ports Single pilot Double pilot 1 2 Number of ports 5 5 port Dimensions Stroke Bottom ported Stroke Side ported Indicator light Indicator light Manual override (Button diameter ø3.5) Manual override (Button diameter ø3.5) 2x6.5 mounting hole Port size 7 x 1/8 mounting hole Port size mounting hole VM VMG VR VH 1901 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com RoHS-VR.qxd 10.7.26 5:08 PM Page 2 Transmitters: Shuttle Valve RoHS Series VR1210/1220 Model/Specifications 3 ported check valve with one output and 2 pneumatic signal input ports. Output always supplied by high pressure inlet. VR1210-01 Model Max. operating pressure Min. operating pressure Min. pressure differential Ambient and fluid temperature Effective area Port size Mass VR1220-02 1.0 MPa 0.05 MPa 0.05 MPa –5 to 60°C (No freezing) 7mm2 15mm2 18 14 24 g 45 g How to Order VR12 1 0 01 Port size Applicable model 01 02 JIS Symbol 18 14 VR 1210 VR 1220 Thread type Nil N F Rc NPT G Body size 1 2 18 14 standard standard Construction When right port has higher pressure When left port has higher pressure (High pressure side) (High pressure side) (Low pressure side) (Low pressure side) Component Parts Material ADC Brass Description No. Body 1 2 Valve seat Note No. Description Platinum silver 3 Valve O-ring 4 Material Brass, NBR NBR Note Dimensions VR1210 VR1220 20 3 x 1/4 3 x 1/8 16 5.5 mounting hole SMC 38 IN 17.2 6.6 mounting hole IN SMC 50 IN 38 16 29 16 OUT IN 20 21 OUT 21.2 1902 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com RoHS-VR.qxd 10.7.26 5:08 PM Page 3 Transmitters: Shuttle Valve with One-touch Fittings Series VR1210F/1220F RoHS Model Relay valves for controlling pneumatic signal lines Applicable tubing O.D. Metric size Model Inch size 3.2 4 6 8 10 쎲 쎲 쎲 쎲 쎲 쎲 쎲 VR1210F VR1220F 1/8" 5/32" 1/4" 5/16" 3/8" 쎲 쎲 쎲 쎲 쎲 쎲 쎲 Specifications 1.5 MPa Proof pressure The air of higher pressure side constantly flows to the OUT side. IN High pressure Max. operating pressure 1.0 MPa Min. operating pressure 0.05 MPa Ambient and fluid temperature –5 to 60°C (No freezing) Applicable tubing material (1) Nylon, Soft nylon, Polyurethane Note 1) Use caution about the maximum operating pressure when soft nylon and polyurethane is used. (Refer to Best Pneumatics No. 6.) Note 2) Brass components are all electroless nickel plated as standard. (Copper-free and fluorine-free) OUT IN Low pressure IN Low pressur OUT IN High pressure JIS Symbol Flow Rate and Effective Area VR1210F Model IN OUT VR1220F ø3.2 ø4 ø6 ø8 ø6 ø8 ø10 ø1/8" ø5/32" ø1/4" ø5/16" ø1/4" ø5/16" ø3/8" Flow rate l/min (ANR) 150 210 420 480 440 680 1000 Effective area (mm2) 2.3 3.2 6.4 7.3 6.7 10.4 15.2 Applicable Metric size tubing O.D. Inch size Note) Flow rate is the value measured under a pressure of 0.5 MPa and a temperature of 20°C. How to Order VR 12 1 0 F 06 VM쏔 Body size 1 2 1/8 standard 1/4 standard Shuttle valve With One-touch fittings VMG Applicable tubing O.D. Metric size Inch size 23 04 06 08 10 ø3.2 ∗ ø4 ø6 ø8 ø10 01 03 07 09 11 VR쏔 ø1/8" ø5/32" ø1/4" ø5/16" ø3/8" VH쏔 ∗ For ø3.2, use ø1/8" tubing. 1903 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com P1889-P1944-E.qxd Series 08.9.2 8:12 PM Page 1904 VR1210F/1220F Example of Operating Circuit OR circuit • If either A or B is turned ON, cylinder is actuated. Self-hold circuit Interlock circuit 1. If A is turned ON, the output turns ON. 2. Even though A is turned OFF, the output remains in ON state. 3. If B is turned ON in 2. state, the output is turned OFF. • When either A or B is turned ON, even though C turns ON, the output 3 will not be turned ON. • Only when both A and B are in OFF state, if C turns ON, the output 3 is turned ON. Output Output 3 B Output 1 A A B Output 2 B C A L5 M2 øD2 øD 3 Dimensions Metric size: Light gray Inch size: Orange IN L3 L4 Blue IN L2 øD1 OUT M1 M1 Applicable tubing O.D. ød L1 Metric size: Light gray Inch size: Orange Metric Size Model VR1210F-23 VR1210F-04 VR1210F-06 VR1210F-08 VR1220F-06 VR1220F-08 VR1220F-10 L2 L3 L4 L5 M1 M2 Mass (g) 52 6.2 19.4 29.8 17.5 12.7 12.9 21.4 53 6 20.3 31.5 21.9 16.5 15.8 15.6 53.2 6.8 35.6 25.2 16.8 16.8 23.0 15.2 60.4 8.1 38.2 28.2 18.7 18.7 24.0 12.8 12.8 59 7.4 37.7 25.2 16.8 16.8 27.2 8 15.2 15.2 65 8.2 39.7 28.2 18.7 18.7 31.9 10 18.5 18.5 71.6 9.8 25.8 44.8 31 20.8 20.8 43.2 d D1 D2 L1 L2 L3 L4 L5 M1 M2 Mass (g) d D1 D2 3.2 11.4 8.4 4 11 10.4 6 12.8 12.8 8 15.2 6 D3 14.8 19.8 L1 22.5 23.9 Inch Size Model VR1210F-01 VR1210F-03 VR1210F-07 VR1210F-09 VR1220F-07 VR1220F-09 VR1220F-11 D3 1/8" 11.4 8.4 52 6.2 19.4 29.8 17.5 12.7 12.9 21.4 5/32" 11 10.4 53 6 20.3 31.5 21.9 16.5 15.8 15.6 1/4" 13.2 13.2 54.4 7.1 36.2 25.6 16.8 16.8 23.5 5/16" 15.2 15.2 60.4 8.1 38.2 28.2 18.7 18.7 24.0 1/4" 13.2 13.2 59 7.4 37.9 25.6 16.8 16.8 31.4 5/16" 15.2 15.2 65 8.2 39.7 28.2 18.7 18.7 31.9 3/8" 17.9 18.5 69.8 9.5 44.5 31 20.8 20.8 53.0 14.8 19.8 22.5 23.9 25.8 1904 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com RoHS-VR.qxd 10.7.26 5:08 PM Page 4 Transmitters: AND Valve with One-touch Fittings Series VR1211F RoHS Model Relay valves for controlling pneumatic signal lines Applicable tubing O.D. Metric size Model VR1211F Inch size 3.2 4 6 1/8" 5/32" 1/4" 쎲 쎲 쎲 쎲 쎲 쎲 Specifications 1.5 MPa Proof pressure Max. operating pressure 1.0 MPa Min. operating pressure 0.05 MPa Ambient temperature and operating fluid temperature Only when air is supplied to both P1 and P2 does air flow to the OUT side. When air pressure differs, pressure in the lower amount flows to the OUT side. –5 to 60°C (No freezing) Applicable tubing material (1) Nylon, Soft nylon, Polyurethane Note 1) Use caution about the maximum operating pressure when soft nylon and polyurethane is used. (Refer to Best Pneumatics No. 6.) Note 2) Brass components are all electroless nickel plated as standard. (Copper-free and fluorine-free) IN P1 OUT IN P2 Flow Rate and Effective Area VR1211F Model Applicable tubing O.D. If air is supplied only to either P1 or P2, it does not flow to the OUT side. IN OUT IN P1 Metric size ø3.2 ø4 Inch size ø6 – ø1/8" ø5/32" – ø1/4" Flow rate l/min (ANR) 100 120 150 170 Effective area (mm2) 1.5 1.8 2.3 2.6 Note) Flow rate is the value measured under a pressure of 0.5 MPa and a temperature of 20°C. OUT IN P2 How to Order IN P1 VR 12 1 1 F OUT 06 VM쏔 IN P2 VMG JIS Symbol Body size 1 1/8 standard AND valve VR쏔 Applicable tubing O.D. Metric size Inch size 23 04 06 ø3.2 ∗ ø4 ø6 01 03 07 VH쏔 ø1/8" ø5/32" ø1/4" ∗ For ø3.2, use ø1/8" tubing. With One-touch fittings 1905 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com P1889-P1944-E.qxd Series 08.9.2 8:12 PM Page 1906 VR1211F Example of Operating Circuit Output 3 • If both A and B are turned ON, which are in different pressure conditions, both output 1 and 2 will turn ON • Only when output 1 and 2 are in the ON state, and C turns ON, will output 3 turn ON. • If either A or B is turned OFF, output 3 will not be turned ON, even if C is turned ON. Output 2 Output 1 A B C L5 M2 øD2 øD 3 Dimensions Metric size: Light gray Inch size: Orange IN IN L2 øD1 OUT L3 L4 Blue M1 M1 Applicable tubing O.D. ød L1 Metric size: Light gray Inch size: Orange Metric Size d D1 3.2 11.4 4 11 10.4 6 12.8 12.8 Model d D1 D2 VR1211F-01 VR1211F-03 VR1211F-07 1/8" 11.4 5/32" 11 10.4 1/4" 13.2 13.2 Model VR1211F-23 VR1211F-04 VR1211F-06 D2 D3 8.4 L2 L3 L4 L5 M1 M2 Mass (g) 6.2 25.7 36.1 17.5 12.7 12.9 26.4 26.6 37.8 21.9 16.5 15.8 20.8 28.8 41.9 25.2 16.8 16.8 25.0 L2 L3 L4 L5 M1 M2 Mass (g) 52 6.2 25.7 36.1 17.5 12.7 12.9 26.4 53 6.8 26.6 37.8 21.9 16.5 15.8 20.8 54.4 7.1 28.8 42.5 25.6 16.8 16.8 27.0 L1 52 14.8 53 53.2 6.8 Inch Size D3 8.4 14.8 L1 1906 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com RoHS-VR.qxd 10.7.26 5:08 PM Page 5 Transmitters: Time Delay Valve Series VR2110 RoHS Model/Specifications Combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period. VR2110-01 Model Supply pressure Signal pressure Time delay Repeatability Operating and fluid temperature Effective area Port size Mass 0 to 1.0 MPa 0.25 to 0.8 MPa 0.5 to 60 s ±10% F.S. –5 to 60°C (No freezing) 2.5 mm2 1 8 500 g Construction Non-actuated Spare tank JIS Symbol Connecting port processing possible Tank Input Signal (PIL) vs. Time Delay Needle Knob Time delay (sec) Actuated before time set Signal pressure (MPa) Example) is the point, which is set by the input signal pressure 0.25 MPa, with a delay time of 60 sec. With the same status, if the input signal pressure is increased to 0.8 MPa, the delay time varies to the point (≅ 40 sec). Actuated after time set Piping Length vs. Release Time VM쏔 Signal/Supply pressure Signal/Supply pressure VMG Release time (sec) VM1 VR쏔 VM2 VH쏔 Component Parts Piping length (m) If the input signal (PIL) is turned OFF, the release time of the time delay valve changes depending upon the effective area of the valve and the length of piping. Please refer to the above graph for the standard values. No. 1 2 3 4 Description Body Piston Piston Needle Note No. Material Platinum silver 5 ADC Brass, NBR Rubber lined 6 Brass, NBR Rubber lined 7 Brass 8 Description Spring Body Plunger Valve Note Material Steel ZDC Platinum silver Stainless steel Brass, NBR Rubber lined 1907 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com P1889-P1944-E.qxd 08.9.2 8:12 PM Page 1908 Series VR2110 How to Order VR2110 01 Option X3 Secondary tank connection board Rc 1 4 X102 N.O. N.C. common type (With VM430) Port size 01 N01 F01 Rc 1 8 NPT 1 8 G1 8 Dimensions Bracket mounted Panel mounted 2 x ø6.5 hole Mounting screw M6 x 1 x 12 Rc 1/4 Spare tank connecting port processing possible 4 x M6 thread Bottom of bracket Knob side Bracket side 4 x ø7 hole Bracket plate t = 2 Panel thickness t = 3 or less Max. 74 Min. 70 Rc 1/8 signal pressure port 2 x M6 x 1.0 thread depth 8 Panel mounting screw ø4 exhaust port Rc 1/8 output pressure port 1908 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 017-VR.qxd 10.12.27 1:20 PM Page 1 Transmitters: Pneumatic-electric Relay RoHS [Option] Series VR3200/3201 Model/Specifications Pneumatic-electric relay converts pneumatic signal to electric relay. Model Construction Weight Operating pressure Ambient and fluid temperature Contacts Port size Standard (CE-compliant) VR3200-01 Open type 130 g VR3201-01 Splashproof (IP44 equivalent) 260 g 0.1 to 1.0 MPa –5 to 60°C (No freezing) 1ab 18 EN60947-5-1:2004 Note) Note) Voltage is up to 30 VDC. Voltage other than that will be inapplicable. Microswitch Rating Non-inductive load (A) Light load Resistance load N.C. N.O. N.C. N.O. 15 15 3 1.5 15 15 2.5 1.25 15 15 3 1.5 15 15 3 1.5 6 6 3 1.5 0.5 0.5 0.5 0.5 0.25 0.25 0.25 0.25 Voltage 125 VAC 250 VAC 8 VDC 14 VDC 30 VDC 125 VDC 250 VDC JIS Symbol Inductive load (A) Inductive load Electric motor load N.C. N.O. N.C. N.O. 15 15 5 2.5 15 15 3 1.5 15 15 5 2.5 10 10 5 2.5 5 5 5 2.5 0.05 0.05 0.05 0.05 0.03 0.03 0.03 0.03 How to Order VR320 0 01 CE-compliant Nil Q — CE-compliant Port size 01 N01 F01 Precautions Be sure to read defore handling. Refer to front matters 58 and 59 for Safety Instructions and pages 3 to 7 for 3/4/5 Port Solenoid Valve Precautions. Rc 1 8 NPT 1 8 G18 Construction 0 1 Open type Splashproof (IP44 equivalent) Construction VM쏔 VMG Piping Warning VR쏔 When connecting a pipe fitting to the IN port, place the wrench over the hexagon portion of the lid. If the wrench is placed over the microswitch body, the neck of the microswitch could break. VH쏔 Component Parts No. 1 2 3 Description Body Cap Piston Material Brass Brass POM Note No. 4 5 Description Spring Microswitch Material Stainless steel Note Contacts 1 ab 1909 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com P1889-P1944-E.qxd 08.9.2 8:12 PM Page 1910 Series VR3200/3201 Dimensions VR3200 VR3201 2 x M4 x 45 G 1/2 Ridges min. 4 Terminal with solder 3 x M4 x 5.5 terminal thread (With cup washer) Detail on microswitch terminals Detail on micro switch terminals 1910 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com RoHS-VR.qxd 10.7.26 5:08 PM Page 7 Transmitters: Pneumatic Indicator Transmitters: Miniature Pneumatic Indicator Series VR3100 Series VR3110 RoHS Indicates the presence of pneumatic pressure. It is equivalent to the pilot lamp of an electrical system. RoHS This is an ultra-compact air indicator light to monitor the presence of air pressure. It is equivalent to the pilot lamp of an electrical system. JIS symbol JIS symbol Model/Specifications Model/Specifications Model VR3100-01R VR3100-01G VR3100-01O Operating pressure 0.1 to 0.8 MPa Ambient and fluid temp. –5 to 60°C (No freezing) Frequency 100 c.p.m. or less Color of indicator Red Green Orange Port size Rc 1 8 Mass 40g Construction VR3110-01R Model Color of indicator Operation Operating pressure Ambient and fluid temp. Frequency Port size Mass VR3110-01G Red Green Piston style 0.15 to 1.0 MPa –5 to 60°C (No freezing) 300 c.p.m. or less R18 6g Construction Clear cover Piston (Red, green, orange) Piston (Red, green) No. 1 2 3 4 5 Material Description Aluminum alloy Body Indicator window Acrylic POM Piston Spring Stainless steel Seal NBR Note Dimensions No. 1 2 3 4 5 Description Body Piston A Plug Spring O-ring Material Brass POM PE Stainless steel NBR Note Dimensions VM쏔 Panel mounting VMG Max. 9 VR쏔 Stroke VH쏔 Panel 1911 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com