AGM VRLA 12V105AH SA12V105C Specifications Nominal Voltage Nominal Capacity 20HR 12 V 105AH Length Width Container Height Total Height (with terminal) Dimensions 306±1mm (12.05 inches) 169±1mm (6.65 inches) 210±1mm (8.27 inches) 215±1mm (8.46 inches) Approx 26.5 kg (58.4 lbs) M6 ABS Plastic Purity Lead 99.995% Distilled Sulfurid Acid (Zero metal content) AGM Approx Weight Terminal Container Material Lead Material Sulfurid Acid Separator 5.25A/105AH 9.8A /98AH 16.1A/80.5AH 24.0A/72AH 61.1A/61AH Rated Capacity (20hr, 1.80V/cell, 25°C/77°F) (10hr, 1.80V/cell, 25°C/77°F) (5hr, 1.75V/cell, 25°C/77°F) (3hr, 1.75V/cell, 25°C/77°F) (1hr, 1.60V/cell, 25°C/77°F) Max. Discharge Current 900A (5s) Internal Resistance Approx 57mΩ Discharge : -15 - 60°C (5 - 122°F) Charge : 0 - 60°C (32 - 104°F) Storage : -15 - 60°C (5 - 104°F) Operating Temp.Range Applications • All purpose 25±3°C (77±5°F] Initial Charging Current less than 31.5A. Voltage 14.5V - 14.9V at 25°C (77°F) Temp.Coefficient -30mV/°C • Standby Applications Standby Use No limit on Initial Charging Current Voltage 13.5V - 13.8V at 25°C (77°F) Temp.Coefficient -20 mV/°C • Uninterruptible Power Supply (UPS) Capacity affected by Temperature 40°C 25°C 0°C • Electric Power System (EPS) Self Discharge Sentry AGM series batteries may be stored for up to 6 months at 25°C (77°F) and then a freshening charge is required. For higher temperatures the time interval will be shorter. Nominal Operating Temp.Range Cycle Use (104°F) (77°F) (32°F) • Recreation Vehicles 103% 100% 86% • Fire & Security • Generators • Medical Equipment Dimensions M6 Terminal 306±1 Unit: mm (inches) 258±1 215±1 58±1 210±1 169±1 Constant Current Discharge (Amperes) at 25°C (77°F) F.V/Time 1.80V/cell 1.75V/cell 1.70V/cell 1.65V/cell 1.60V/cell 10 min 15min 30min 45min 1h 3h 5h 157 168 179 200 210 128 138 149 157 168 82.1 85.2 97.8 92.7 97.6 61.8 64.2 66.6 70.1 73.2 51.6 53.8 55.2 55.8 61.1 22.9 24.0 24.8 25.7 26.7 15.6 16.1 16.6 16.9 17.1 F.V/Time 1.80V/cell 1.75V/cell 1.70V/cell 1.65V/cell 1.60V/cell 5 min 10 min 15min 30min 45min 1h 3h 5h 372 405 430 479 491 302 330 332 350 359 128 138 276 294 299 159 163 167 176 184 123 125 126 136 142 99.5 101 105 110 115 44.8 45.0 46.3 47.7 47.8 30.1 30.5 31.3 31.7 32.1 Constant Power Discharge (Watts/Cell) at 25°C (77°F) Discharge Characteristics 12V Battery (V) 13.0 Float Charging Characteristics Temperature: 25°C(77°F) Charge Charging Volume Current % (XCA) 0.10CA-2.25V/cell temperature 25°C Charging Voltage (V) 12.0 11.0 0.40 10.0 0.628C 1C 9.0 8.0 3C 1 2 4 0.2070 0.093C 0.05C 2C 6 8 10 20 40 60 2 4 6 8 10 20 H Min 0.25 120 110 100 90 80 70 60 50 40 30 20 10 0 7.5 Charged Volume 0.20 7.0 Charge Voltage (Constant 2.25v/cell) 0.15 6.5 After 50% Discharge 0.10 6.0 After 100% Discharge 0.05 5.5 Charging Current 0 0 4 8 12 Discharge Time 16 20 24 28 32 36 40 Charging Time (hours) Temperature Effects in Relation to Battery Capacity Effect of Temperature on Long Term Float Life 10 8 120 6 5 4 3 100 80 60 Charging Voltage : 2.25V / cell 2 40 1 20 0 0.5 -20 -10 0 10 20 30 40 20 68 50 30 86 Temperature (°C) Testing condition Discharging: current 0.17CA (FV1.7V/cell): Charging: current 0.25C max, voltage 2.45V/cell; Charging volume: 125% of discharged capacity 100 100 40 80 20 50 % DOD 0 30 % DOD 0 0 200 400 600 800 1000 50 80 100 0.15C10 0.15C10 0.20C10 0.15C10 0.20C10 0.15C10 0.20C10 C 2 4 6 8 10 12 Supplementary charge may often fail to recover the capacity. The battery should never be left standing still this is reached. State of Charge (SOC) Currency Limit (A) Constant Voltage (V) Fully Charged Time (h) 0.20C10 30°C Supplementary charge required before use. Optional charging way as follows the table charging system. 1200 Charging System 20 40°C B No supplementary charge required (Carry out supplementary charge before use if 100% capacity is required Number of Cycles DOD 25°C Storage Time (Months) Ambient Temperature: 25°C (77°F) 20 A 10°C 80 60 100 % DOD °C °F Self Discharge Characteristics 120 40 50 122 Battery Temperature Cycle Life in Relation to Depth of Discharge 60 40 104 State of Charge (% of full charge capacity) 13.5-13.8 vpc (12V) 6.75-6.9 vpc (6V) 10 8 2.14-2.15 12.84-12.90 6.42-6.46 100 13.5-13.8 vpc (12V) 6.75-6.9 vpc (6V) 15 2.12-2.13 12.72-12.78 6.36-6.39 90 13.5-13.8 vpc (12V) 6.75-6.9 vpc (6V) 16 2.11 12.66 6.33 80 2.09 12.54 6.27 70 13.5-13.8 vpc (12V) 6.75-6.9 vpc (6V) 20 2.07 12.42 6.21 60 18 2.05 12.30 6.15 50 12 14 Open Circuit Voltage (12V/cell) Open Circuit Voltage (6V/cell) Open Circuit Voltage (V/cell) Domestic Sales | Ph: +61 (0)7 3386 1102 | Fax: +61 (0)7 3102 9913 [email protected] | www.sealedperformance.com.au National Warehouse | 1 Ant Road | Yatala, Brisbane QLD 4207 Melbourne Office | 2/9 Compark Circuit | Mulgrave, Melburne VIC 3170