Preview only show first 10 pages with watermark. For full document please download

Vspbnca Datasheet

   EMBED


Share

Transcript

DTK-GLI Ground Loop I solator General P roduct Specifications DITEK’s GLI (Ground Loop Isolator) is a passive device that utilizes state-of-the-art hybrid circuit technology to cure video distortion caused by ground loops. DTK-GLI Ground Loop Defined A difference in potential can be introduced when two power distribution systems, such as what is found in two separate buildings, supply power to the camera and head end equipment independently of each other where the impedance of the electrical ground varies. The result is the presence of AC current in the cable shield. Typical symptoms are “hum” which appears on one or more horizontal bars, horizontal tearing or pulling, and vertical rolling. DTK-GLI Product Features Specifications • Protects and restores the video signal • Multi-stage, hybrid design • Small footprint easy installation • Connects in series • Prevents video signal distortion caused by video ground loops. • Passive device allows for two-way communication of control/video • Ten Year Limited Warranty Connection Method: BNC Female In/Out Impedance: 75 Ohms Insertion Loss: 1.1dB (5 MHz) Common Mode Ground Loop Rejection Rate: 90 dB at 50/60 Hz Dielectric Withstand Voltage: 1000VAC @ 60Hz for 2 seconds Operating Temperature: -40°F - 158°F (-40°C - 70°C) Maximum Humidity: 95% non-condensing Dimensions: 1.3”H x 3.0”W x 2.4”D (33.02mm x 76.20mm x 60.96mm) Weight: 4oz (113g) Housing: ABS One DITEK Center 1720 Starkey Road Largo, FL 33771 1-800-753-2345 Direct: 1-727-812-5000 Technical Support: 1-888-472-6100 www.ditekcorp.com Document: SPS-100080-001 Rev 1 2/13 ©2007 DITEK Corp. Specification Subject to Change