Preview only show first 10 pages with watermark. For full document please download

Vz 00 Eu

   EMBED


Share

Transcript

3 Port Solenoid Valve Rubber Seal VZ100/300/500 Solenoid Valve Variations Series Port Size Effective Area mm2 (Nl/min ) Actuation Voltage Electrical Entry Option/light and surge voltage suppressor SY Manual Override SYJ VK VZ100 N.C. VZ P→A: 0.6 (33.37) 0.9 A→R: (49.08) VT Non-locking push style M5 N.O. VT Body Ported R→A: 0.6 (33.37) A→P: 0.6 (33.37) VP VG VZ300 M5 3.6 (196.3) VQ VZ500 18 9.0 (490.75) N.C. N.O. (Option) 24V AC 50/60Hz 48V AC 50/60Hz 110V AC 50/60Hz 220V AC 50/60Hz 6V DC 12V DC 48V DC DIN Terminal (D) Indicator light and surge voltage suppressor Non-locking push style VZ300 Base Mounted VQZ (Standard) 100V AC 50/60Hz 200V AC 50/60Hz 24V DC 18 4.5 (245.38) 1 8, 1 4 9.0 (490.75) Locking slotted style Locking knob style VZ500 2.4-1 VZ100/300/500 Manifold Variations Body Ported Valve Series VZ100 Top VZ300 Top VZ500 Base Mounted A port position VZ300 VZ500 P/ R port size M5 A port size With one-touch fitting 18 Applicable tube O.D. ø4 ø6 ø8 M5 X 0.8 — — — — 18 — — — — 18 — — — — — — — — — — — — — 18 — 14 — (1) Top Bottom 18 — Side Bottom 18 14 Side 14 — — — (1) — — — — — — — Note 1) Internal pilot Series VZ500 Series VZ100 Series VZ300 2.4-2 Precautions Be sure to read before handling. Refer to p.0-33 to 0-36 for Safety Instructions and common precautions. DIN terminal Warning Manual Override AC  Manual override is capable in 2 ways, non-locking push style and locking style. (Locking style is for VZ300, VZ500 only) The non-locking push style must be pressed in the direction of the arrow. The locking style must be turned in the direction of the arrow. –: Non-locking push style B: Locking slotted style DC SY C: Locking knob style SYJ VK With light (AC) VZ When operating the locking style manually, apply torque of 0.2Nm or less. AC VT With light (DC) ∗ Marking VT DC  During manual operation, the equipment that is connected will operate. Therefore, make sure there are no hazardous conditions before operation. In the case of DC wiring, connect terminal No.1 of the connector to the positive [+] side, and terminal No. 2 to the negative [–] side. (Refer to the marks on the terminal board.) VP VG Common Exhaust for Main Valve & Pilot Valve VZ324M, VZ524M Exhaust air from the pilot valve will flow to the main valve exhaust port. For use in an environment in which exhaust from the pilot valve is undesirable. For use when the intrusion of dust from the surroundings must be prevented. Also, make sure the piping will not restrict the flow from the exhaust port. VQ VQZ 2.4-3 VZ100/300/500 How to Use DIN Connector How to Order Solenoid Assembly Connection DXT170 C 1) Loosen set screw and pull out connector from the terminal block of solenoid. 2) Pull out screw and insert a screwdriver into the slit area near the bottom of terminal block to separate block and housing. 3) Loosen the terminal screw of the terminal block, place bare end of lead wire into terminal in accordance with the wiring method, and affix it securely with the terminal screw. 4) Tighten ground nut to secure the wire. 5 L Applicable model A C E VZ110 VZ300 Series VZ500 VZ120 – Z∗ S Precautions Plug the connector in or out vertically, never at an angle. Applicable cable Cable O.D. ø3.5 to ø7 (Reference) 0.5mm2 2-core and 3-core wires equivalent to JISC3306. Coil rated voltage 1 2 3 4 5 6 9 Order Made 100V AC 50/60Hz 200V AC 50/60Hz 200V AC 50/60Hz 220V AC 50/60Hz 24V DC 12V DC Others Refer to the p.0-36 for flow rate. Connector Part No. Without light K31 With light Rated voltage 100V AC 200V AC 110V AC 220V AC 240V AC 6V DC 12V DC 24V DC 48V DC Symbol 100V 200V 110V 220V 240V 6VD 12VD 24VD 48VD Part No. K33 K32 Connector with Light Circuit DC circuit AC circuit NL: Neon light R: Resistor 2.4-4 D : Protection diode LED : Light emitting diode R : Resistor Surge voltage suppressor Electrical entry D DO Contact SMC for other voltages (9) Flow rate None Indicator light and surge suppressor ∗Indicator light is not available for grommet style. Change of electrical entry (orientation) After separating the terminal block and housing, mount the housing at any position (total 4 directions, per 90 degrees), therefore changing electrical entry. ∗In the case of indicator light, avoid damaging the light with lead wire. Q Indicator light and surge suppressor DIN terminal With connector Without connector 3 Port Body Ported Rubber Seal VZ100 Series How to Order r SY su pp re s so SYJ ig D n io pt VT O Po In di ca rt s to iz e rl le ca tri ec El ed at R VT ht ry nt ge lta vo n io at Ac tu 5 an d su ar ea ur ce so g rin rd e O E VZ1 1 0 Body Ported VZ rg e co de vo lta ge VK M5 Q VP VG Option F: With foot style bracket Actuation Normally closed 1 VQ Normally open VQZ Note) Bracket is not assembled. 2 Port size M5 Regarding VZ120, R port is a supply port. Rated voltage Ordering source area code Code E N areas Japan,Asia Australia,England Europe North America 1 2 3 4 5 6 9 Order Made 100V AC 50/60Hz 200V AC 50/60Hz 110V AC 50/60Hz 220V AC 50/60Hz 24V DC 12V DC Others M5 Indicator light and surge voltage suppressor – None Z∗ With indicator light and surge voltage suppressor With surge voltage suppressor S ∗ DOZ is not available. Electrical entry DIN terminal D: With connector Contact SMC for other voltages (9) DO: Without connector Protective class class I (Mark: ) 2.4-5 VZ100 Specifications Low Power Consumption: 1.8WDC Applicable for Vacuum Use –100kPa Air See below Max. 50 15 or less 15 See below Non-locking push style Non-lube Free 300/50 Dust proof Fluid Operating pressure range Ambient and fluid temperature (°C) Response time (ms)(1) Max. operating frequency (Hz) Effective area Manual override Lubrication Mounting position Impact/Vibration resistance (m/s2) (2) Protection structure Note 1) According to dynamic performance test of JIS B8374-1981.(Coil temperature 20°C, rated voltage, without surge voltage suppressor) Note 2) Impact resistance: No malfunction from test using drop impact tester, to axis and right angle directions of main valve and armature, each one time when energized and de-energized. (Value in the initial stage.) Vibration resistance: No malfunction from test with 45 to 1000Hz 1 sweep, to axis and right angle directions of main valve and armature, each one time when energized and de-energized. (Value in the initial stage.) Solenoid specifications ∗Option DIN terminal(D) Electrical entry Coil rated voltage V Refer to the p.2.4-8 to 2.4-10 for manifold use. AC50/60Hz DC 100, 200, 24∗, 48∗, 110∗, 220∗ 24, 6∗, 12∗, 48∗ 15 to +10% rated voltage DC 1.8(with light 2.1) [24V DC: 75(with light 87.5)] Allowable voltage Power consumption W Note) [Current mA] Apparent power VA Note) [Current mA] 100V AC: 45/50Hz, 42/60Hz 200V AC: 22.5/50Hz, 21/60Hz 100V AC: 35/50Hz, 30/60Hz 3.5/50Hz, 3/60Hz 200V AC: 17.5/50Hz, 15/60Hz DC: diode, AC: ZNR DC: LED(Red), AC: Neon light 4.5/50Hz, 4.2/60Hz Inrush AC Holding Surge voltage suppressor Indicator light Note) At rated voltage Option Description Model No. Foot style bracket DXT170-34-1A Silencer M5 AN120-M5 (ø8 X 17l) Note With mounting screw (M3 X 6) For valve unit (R port), Noise reduction: 21dB or more, Effective orifice 5mm2 Operating Pressure Range and Effective Area Valve Actuation Vacuum specification MPa P port R port Operating press. range (MPa) VZ110 N.C. 0 to 0.7 –27kPa to0.6 –100kPa to 0 VZ120 N.O. 0 to 0.5 –100kPa to 0 –100kPa to 0.4 Construction Port size Effective Weight area (mm2) (g) M5 X 0.8 P→A: 0.6 (33.37) A→R: 0.9 (49.08) R→A: 0.6 (33.37) A→P: 0.6 (33.37) 70 Note) Regarding VZ120, R port is a supply port. Construction VZ110 (N.C.) VZ120 (N.O.) JIS symbol De-energized JIS symbol De-energized Component Parts Description Body Push rod EXH poppet N.C. Back up spring r N.O. poppet spring No. q w e Material Note ZDC Platinum silver Resin NBR SUS Replacement Parts No. Description 2.4-6 t Solenoid Ass’y y Solenoid Ass’y u O ring Part No. Material Note Epoxy, Stainless DXT170-A- VZ110 steel Epoxy, Stainless DXT170-E- VZ120 steel Common 13 X 11 X 1 NBR with VZ 3500 VZ100 Body Ported Grommet (G), (H) VZ10-GH-M5 SY SYJ VK VZ VT VT VP VG VQ VQZ Note: This valve series is now only available with DIN connector. L plug connector (L) VZ10-L-M5 M plug connector (M) VZ10-M-M5 DIN terminal (D) VZ10-D-M5-Q : with indicator light and surge voltage suppressor 2.4-7 Series VZ100 Manifold Manifold Specifications Model Manifold P(SUP)/R(EXH)style Valve stations A port Position piping Direction P/R port Port size A port Valve effective area mm2 (Nl/min)(2) VV3Z1-01- 1 VV4Z1-20Single base/B mount Common SUP and EXH type 2 to 20 stations (1) Valve Top 18 M5 M5 P→A: 0.5 (27.48) A→R: 0.86 (47.11) R→A: 0.56 (30.43) A→P: 0.5 (27.48) VZ110 VZ120 Page on How to Order 1 p.2.4-9 p.2.4-10 Note 1) If there are more than 10 stations, exhaust from both sides of manifold. Note 2) Value at manifold base mounted Note 3) Not able to use VZ120 and VZ110 on the same manifold base. Note 4) In case of VZ120, supply air to R port and exhaust from P port. How to Order Manifold Base To order valves and blank plate assembly mounted onto the manifold, list valves and blank plate assembly with manifold base. (Sample) VV3Z1-01-031-Q ··········1 pc. (Manifold base) VZ110-5D-M5-Q ···········2 pcs. (Valve) DXT170-25-1A-Q··········1 pc. (Blank plate assembly) Option Combinations of solenoid valve, gasket and manifold base Individual EXH spacer assembly Individual SUP spacer assembly DXT170-48-1A DXT170-44-1A Applicable base VV3Z1-01-1 VV4Z1-20-1 Manifold base Blank plate assembly DXT170-25-1A Applicable base VV3Z1-01-1 Manifold base VV4Z1-20-1 2.4-8 Applicable base Applicable base VV3Z1-01-1 Manifold base VV4Z1-20-1 VV3Z1-01-1 VV4Z1-20-1 Manifold base VZ100 01 Type Manifold Base: Top Ported Grommet (G), (H) How to Order E VV3Z1 01 05 1 Q Option Stations E N areas Japan,Asia Australia,England Europe North America 20 … Code SY F: With foot bracket 2 stations … Ordering source area code 02 SYJ 20 stations P, R port thread 00F 00N 00T VK Rc (PT) G (PF) NPT NPTF VZ ∗ The bracket is not assembled. VT Note)  If there are more than 10 stations, exhaust from both sides manifold.  It is not able to use VZ110 and VZ120 on the same manifold base. VT VP Applicable solenoid valve VZ110--M5-Q VZ120--M5-Q Applicable blank plate assembly DXT170-25-1A Individual EXH spacer assembly DXT170-48-1A Individual SUP spacer assembly DXT170-44-1A VG VQ VQZ Note: This valve series is now only available with DIN connector. Station L1 L2 L3 L4 2 48 40 16 8 3 64 56 32 24 L plug connector (L) 4 80 72 48 40 5 96 88 64 56 6 112 104 80 72 7 128 120 96 88 8 144 136 112 104 9 160 152 128 120 10 176 168 144 136 11 192 184 160 152 12 208 200 176 168 13 224 216 192 184 M plug connector (M) 14 241 232 208 200 15 256 248 224 216 16 272 264 240 232 17 288 280 256 248 18 304 296 272 264 19 320 312 288 280 20 336 328 304 296 DIN terminal (D) : with indicator light and surge voltage suppressor 2.4-9 VZ100 20 Type Manifold Base: Top Ported Grommet (G), (H) How to Order E VV4Z1 20 05 1 Q Stations Ordering source area code E N areas Japan,Asia Australia,England Europe North America 20 F: With foot bracket … - Option 2 stations … Code 02 20 stations P, R port thread 00F 00N 00T Rc (PT) G (PF) NPT NPTF ∗ The bracket is not assembled. Note)  If there are more than 10 stations, supply air to SUP port on both sides of the manifold and exhaust from EXH port on both sides of the manifold.  It is not able to use VZ110 and VZ120 on the same manifold base. Applicable solenoid valve VZ110--M5-Q VZ120--M5-Q Applicable blank plate assembly DXT170-25-1A Individual EXH spacer assembly DXT170-48-1A Individual SUP spacer assembly DXT170-44-1A Note: This valve series is now only available with DIN connector. Station L1 L2 L3 L4 2 53 40 16 8 3 69 56 32 24 L plug connector (L) 4 85 72 48 40 5 101 88 64 56 6 117 104 80 72 7 133 120 96 88 8 149 136 112 104 9 165 152 128 120 10 181 168 144 136 11 197 184 160 152 12 213 200 176 168 13 229 216 192 184 M plug connector (M) : with indicator light and surge voltage suppressor 2.4-10 14 245 232 208 200 15 261 248 224 216 16 277 264 240 232 17 293 280 256 248 18 309 296 272 264 DIN terminal (D) 19 325 312 288 280 20 341 328 304 296 3 Port Body Ported, Base Mounted Rubber Seal VZ300 Series How to Order SY Ordering source area code Option M5: M5 E VZ3 1 2 5 D Base Mounted E VZ3 1 4 5 D O pt io n rt S iz e VZ Po ec tri vo El ed at R ca In l e vo dic ntr lta at y ge or su ligh pp t a M re nd an ss s ua or ur ge lo ve rri de ge lta n tio Bo tu Ac dy at io op n rin rd e O Body Ported VK F: With foot bracket de co g so E N SYJ Port Size ar ea - areas Japan,Asia Australia,England Europe North America ur ce Code M5 Q Note) •The bracket is not assembled. •Except for external pilot VT VP VG Q Thread Actuation F N T Normally closed 1 Port size Rc (PT) G (PF) NPT NPTF VQ –: Without sub-plate 01: With 1/8 sub-plate VQZ Normally open 2 Body option –: Individual pilot exhaust VT M: Common exhaust R: External pilot (pilot and main valve) Note) Electrical entry Manual override DIN terminal –: Non-locking push style D: With connector B: Locking slotted C: Locking knob style style Note) VZ32R is only for Manifold. Rated voltage 1 2 3 4 5 6 9 100V AC 50/60Hz 200V AC 50/60Hz 110V AC 50/60Hz 220V AC 50/60Hz 24V DC 12V DC Others Order Made Contact SMC for other voltages (9) DO: Without connector Indicator light and surge voltage suppressor – Z∗ S None Indicator light and surge voltage suppressor Surge voltage suppressor ∗ DOZ is not available. Protective class class I (Mark: ) 2.4-11 VZ300 Specifications Low Power Consumption: 1.8WDC Applicable for Vacuum Use –100kPa VZ300R: External pilot style Exhaust measures for the pilot valve are unnecessary. VZ300M: Central exhaust style It is not necessary to take exhaust measures for the pilot valve for environmental protection. Can also be used as a selector valve or a divider valve. VZ300R: External pilot style Can be used for universal porting. Air Fluid Operating pressure Internal pilot (MPa) Ambient and fluid temperature (˚C) Response time (ms) {0.5MPa} (1) Max. operating frequency (Hz) Effective area 0.15 to 0.7 Max. 50 20 or less 10 See below Non-locking push style, Locking slotted style, Locking knob style Individual pilot exhaust, Common exhaust (pilot and main valve) Non-lube Free 300/50 Dust proof Manual override (2) Pilot exhaust Lubrication Mounting position Impact/vibration resistance (m/s2) (3) Protection structure Note 1) According to dynamic performance test of JIS B8374-1981.( Coil temperature 20˚C, rated voltage, Note 2) without surge voltage suppressor) Note 3) When operating the locking style manually, apply torque of 0.2Nm or less. Impact resistance: No malfunction from test using drop impact tester, to axis and right angle directions of main valve and armature, each one time when energized and de-energized. Vibration resistance: (Value in the initial stage.) No malfunction from test with 8.3 to 2000Hz 1 sweep, to axis and right angle directions of main valve and armature, each one time when energized and deenergized. (Value in the initial stage.) Solenoid Specifications ∗Option DIN terminal (D) Electrical entry Coil rated voltage V Series VZ300/Body Ported Allowable voltage % Power consumption W [Current mA] Apparent power VA [Current mA] AC50/60Hz DC 100, 200, 24∗, 48∗, 110∗, 220∗ 24, 6∗, 12∗, 48∗ –15 to +10% of rated voltage DC 1.8 (with light 2.1)[24VDC: 75 (with light 87.5)] (1) Inrush (1) AC Holding Surge voltage suppressor Indicator light 100V AC: 45/50Hz, 42/60Hz 200V AC: 22.5/50Hz, 21/60Hz 100V AC: 35/50Hz, 30/60Hz 3.5/50Hz, 3/60Hz 200V AC: 17.5/50Hz, 15/60Hz DC: Diode, AC: ZNR DC: LED(red), AC: Neon light 4.5/50Hz, 4.2/60Hz Note 1) At rated voltage Effective Area and Weight Actuation Valve Body ported style Series VZ300/Base Mounted Base mounted style (with sub-plate) VZ312 VZ322 VZ314 VZ324 N.C. N.O. N.C. N.O. Port size Effective area (mm2) (Nl/min) Weight (g) M5 X 0.8 3.6 (196.3) 75 18 4.5 (245.38) 105 (without sub-plate: 75) Option Description Foot bracket Refer to p.2.4-16 to 2.4-28 for manifold use. 2.4-12 Part No. DXT170-34-1B Note With screw (for VZ32) VZ300 External Pilot VZ300R This obtains external pressure for the pilot valve separately from the main valve pressure. It can be operated with a low pressure line with a vacuum (to –100kPa) or below 0.15MPa. JIS symbol VZ31R SY Specifications SYJ Base mounted style(VZ314R, VZ324R) Applicable model Main pressure –100kPa to 0.7 Operating pressure range External pilot pressure MPa 0.15 to 0.7 VK VZ VZ32R Note 1) Refer to the p.2.4-16 for manifold base. Note 2) In the case of the body ported style, the pilot style (VZ32R) is used exclusively on a manifold. An external pilot style that can be used individually is available as a Made to Order. VT VT VP VG VQ Construction VQZ N.C. N.O. Component Parts No. q w e r t y Description Body Piston plate End cover Piston Spool valve ass’y Spool spring Replacement Parts Material Aluminium die cast Resin Aluminium die cast Resin Note Platinum silver Black Black No. u i o Description Sub-plate Solenoid ass’y O-ring Part No. Material Aluminium die cast DXT200-13-1P Epoxy, stainless steel DXT170-C- 13 X 11 X 1 NBR Note Common with VZ100 Stainless steel 2.4-13 VZ300 Body Ported Grommet (G), (H) VZ32-G H-M5 Note: This valve series is now only available with DIN connector. L plug connector (L) VZ32-L-M5 M plug connector (M) VZ32-M-M5 : with indicator light and surge voltage suppressor 2.4-14 DIN terminal (D) VZ32-D-M5-Q VZ300 Base Mounted Grommet (G), (H) VZ34-G H-01 SY SYJ VK VZ VT VT VP VG VQ VQZ Note: This valve series is now only available with DIN connector. L plug connector (L) VZ34-L-01 M plug connector (M) VZ34-M-01 DIN terminal (D) VZ34-D-01-Q : with indicator light and surge voltage suppressor 2.4-15 Series VZ300 Manifold Manifold Specifications Internal pilot External pilot Model 2021R- Manifold P(SUP)/R(EXH) style Stations A port Position piping Direction P, R port Valve Top X port (2) Valve effective area (mm2) (Nl/min) Page on How to Order 402 401 40R2 40R1 Single base/B mount Common SUP/Common EXH 2 to 20 Base Bottom Side 18 A port Port size 1 1 18 M5 X 0.8 (1) 18 M5 X 0.8 M5 X 0.8 Body ported VZ32/VZ32R 3.4 (0.19) Base mounted VZ34/VZ34R – Internal pilot External pilot p.2.4-17 p.2.4-23 18 M5 X 0.8 M5 X 0.8, 1 8 , C4(ø4One touch fitting), C6(ø6One touchfitting) M5 X 0.8 – M5: 3.8(206.12) : 4.7(255.19) 18 p.2.4-18, 24-19 p.2.4-24, 24-25 M5: 3.3(176.67) 4.8(265.01) C4, C6: 3.8(206.12) p.2.4-20 to 2.4-22 p.2.4-26 to 2.4-28 1 8: Note 1) Only for external pilot Note 2) Value at manifold base mounted How to Order Manifold Base To order valves and blank plate assembly mounted onto the manifold, list valves and blank plate assembly with manifold base. (Sample) VV3Z3-20-031-Q···1 pc. (Manifold base) VZ312-5D-M5-Q····2 pcs. (Valve) DXT170-25-1A ······1 pc. (Blank plate ass’y) Option Combinations of solenoid valve, manifold gasket and manifold base Blank Plate Assembly Body ported (VZ32) DXT200-8-1A Base mounted (VZ34) Applicable base Sub-plate Applicable base Applicable base VV3Z3-21R-1 Manifold base Applicable base VV3Z3-20-1 Manifold base Sub-plate VV3Z3-40-2 VV3Z3-40-1 VV3Z3-40R-2 VV3Z3-40R-1 VV3Z3-40-2 VV3Z3-40-1 VV3Z3-40R-2 VV3Z3-40R-1 Manifold base Model No.: DXT170-25-1A Manifold base Applicable base VV3Z3-20-1 VV3Z3-21R-1 Manifold base 2.4-16 VZ300 For Internal Pilot 20 Type Manifold: Top Ported Grommet (G), (H) How to Order E VV3Z3 20 05 1 Q Ordering source area code E N … - areas Japan,Asia Australia,England Europe North America 00F 00N 00T 2 stations … Code 02 SY P, R port thread Stations 20 20 stations Rc (PT) G (PF) NPT NPTF SYJ VK Note) If more than 6 stations, supply air to P port on both sides of the manifold and exhaust from R port on both sides of the manifold. VZ VT Note) If > 6 stations, supply air to P port on both sides of the manifold and exhaust from R port on both sides of the manifold. VT VP Applicable solenoid valve VZ312--M5-Q VZ312M--M5-Q VZ322--M5-Q VZ322M--M5-Q VG Applicable blank plate assembly DXT170-25-1A VQ VQZ Note: This valve series is now only available with DIN connector. Station L1 L2 L3 L4 2 53 40 16 8 3 69 56 32 24 L plug connector (L) 4 85 72 48 40 5 101 88 64 56 6 117 104 80 72 7 133 120 96 88 8 149 136 112 104 9 165 152 128 120 10 181 168 144 136 11 197 184 160 152 12 213 200 176 168 13 229 216 192 184 M plug connector (M) 14 245 232 208 200 15 261 248 224 216 16 277 264 240 232 17 293 280 256 248 18 309 296 272 264 19 325 312 288 280 20 341 328 304 296 DIN terminal (D) : with indicator light and surge voltage suppressor 2.4-17 VZ300 For Internal Pilot 40 Type Manifold: Bottom Ported Grommet (G), (H) How to Order E VV3Z3 40 05 2 M5 P, R port thread Stations 02 E N 20 areas Japan,Asia Australia,England Europe North America Rc (PT) G (PF) NPT NPTF Note) If more than 9 stations, supply air to P port on both sides of the manifold and exhaust from R port on both sides of the manifold. … Code F N T 2 stations … Ordering source area code 20 stations A port size M5 Q M5 X 0.8 Note) If > 9 stations, supply air to P port on both sides of the manifold and exhaust from R port on both sides of the manifold. Note: This valve series is now only available with DIN connector. Applicable solenoid valve VZ314--Q VZ314M--Q VZ324--Q VZ324M--Q Applicable blank plate assembly DXT200-8-1A Station L1 L2 2 52 43 3 68 59 L plug connector (L) 4 84 75 5 100 91 6 116 107 7 132 123 8 148 139 9 164 155 10 180 171 11 196 187 12 212 203 13 228 219 M plug connector (M) : with indicator light and surge voltage suppressor 2.4-18 14 244 235 15 260 251 16 276 267 17 292 283 18 308 299 DIN terminal (D) 19 324 315 20 340 331 VZ300 For Internal Pilot 40 Type Manifold: Bottom Ported Grommet (G), (H) How to Order E VV3Z3 40 05 2 01 Stations E N areas Japan,Asia Australia,England Europe North America 20 Rc (PT) G (PF) NPT NPTF Note) If more than 9 stations, supply air to P port on both sides of the manifold and exhaust from R port on both sides of the manifold. 20 stations A port size 18 01 SYJ F N T … Code SY P, R port thread 2 stations … Ordering source area code 02 Q Note) If > 9 stations, supply air to P port on both sides of the manifold and exhaust from R port on both sides of the manifold. VK VZ VT VT VP Note: This valve series is now only available with DIN connector. Applicable solenoid valve VZ314--Q VZ314M--Q VZ324--Q VZ324M--Q VG Applicable blank plate assembly DXT200-8-1A VQ VQZ Station L1 L2 2 63 54 3 80 71 L plug connector (L) 4 97 88 5 114 105 6 131 122 7 148 139 8 165 156 9 182 173 10 199 190 11 216 207 12 233 224 13 250 241 M plug connector (M) 14 267 258 15 284 275 16 301 292 17 318 309 18 335 326 19 352 343 20 369 360 DIN terminal (D) : with indicator light and surge voltage suppressor 2.4-19 VZ300 For Internal Pilot 40 Type Manifold: Side Ported How to Order E VV3Z3 40 05 1 M5 Stations 02 E N areas Japan,Asia Australia,England Europe North America 20 F N T Rc (PT) G (PF) NPT NPTF Note) If more than 9 stations, supply air to P port on both sides of the manifold and exhaust from R port on both sides of the manifold. … Code P, R port thread 2 stations … … Ordering source area code 20 stations A port size M5 Grommet (G), (H) Q M5 X 0.8 Note) If > 9 stations, supply air to P port on both sides of the manifold and exhaust from R port on both sides of the manifold. Applicable solenoid valve VZ314--Q VZ314M--Q VZ324--Q VZ324M--Q Applicable blank plate assembly DXT200-8-1A Note: This valve series is now only available with DIN connector. Station L1 L2 2 52 43 3 68 59 L plug connector (L) 4 84 75 5 100 91 6 116 107 7 132 123 8 148 139 9 164 155 10 180 171 11 196 187 12 212 203 13 228 219 M plug connector (M) : with indicator light and surge voltage suppressor 2.4-20 14 244 235 15 260 251 16 276 267 17 292 283 18 308 299 DIN terminal (D) 19 324 315 20 340 331 VZ300 For Internal Pilot 40 Type Manifold: Side Ported How to Order E VV3Z3 40 05 1 01 Code E N areas Japan,Asia Australia,England Europe North America SYJ P, R port thread Stations Ordering source area code SY Grommet (G) (H) Q 02 2 stations 20 20 stations F N T Rc (PT) G (PF) NPT NPTF Note) If more than 9 stations, supply air to P port on both sides of the manifold and exhaust from R port on both sides of the manifold. A port size 18 01 Note) If > 9 stations, supply air to P port on both sides of the manifold and exhaust from R port on both sides of the manifold. VK VZ VT VT VP Note: This valve series is now only available with DIN connector. VG Applicable solenoid valve VZ314--Q VZ314M--Q VZ324--Q VZ324M--Q VQ Applicable blank plate assembly DXT200-8-1A VQZ Station L1 L2 2 53 44 3 70 61 L plug connector (L) 4 87 78 5 104 95 6 121 112 7 138 129 8 155 146 9 172 163 10 189 180 11 206 197 12 223 214 13 240 231 M plug connector (M) 14 257 248 15 274 265 16 291 282 17 308 299 18 325 316 19 342 333 20 359 350 DIN terminal (D) : with indicator light and surge voltage suppressor 2.4-21 VZ300 For Internal Pilot 40 Type Manifold: Side Ported Grommet (G), (H) How to Order E VV3Z3 40 05 1 C6 Stations Ordering source area code Code E N 02 2 stations 20 20 stations P, R port thread F N T A port size areas Japan,Asia Australia,England Europe North America Q C4 ø4 One-touch fitting C6 ø6 One-touch fitting Rc (PT) G (PF) NPT NPTF Note) If more than 9 stations, supply air to P port on both sides of the manifold and exhaust from R port on both sides of the manifold. Note) If > 9 stations, supply air to P port on both sides of the manifold and exhaust from R port on both sides of the manifold. Applicable solenoid valve VZ314--Q VZ314M--Q VZ324--Q VZ324M--Q Applicable blank plate assembly DXT200-8-1A Note: This valve series is now only available with DIN connector. Station L1 L2 2 50 41 3 66 57 L plug connector (L) 4 82 73 5 98 89 6 114 105 7 130 121 8 146 137 9 162 153 10 178 169 11 194 185 12 210 201 13 226 217 M plug connector (M) : with indicator light and surge voltage suppressor 2.4-22 14 242 233 15 258 249 16 274 265 17 290 281 18 306 297 DIN terminal (D) 19 322 313 20 338 329 VZ300 For External Pilot 21R Type Manifold: Top Ported Grommet (G), (H) SY How to Order E VV3Z3 E N 05 1 areas Japan,Asia Australia,England Europe North America 02 2 stations 20 20 stations SYJ Q P, R port thread Stations Ordering source area code Code 21R 00F 00N 00T VK Rc (PT) G (PF) NPT NPTF VZ VT Note) If more than 9 stations, supply and exhaust air through P port or R port on both sides of the manifold. Note) If > 9 stations, supply and exhaust air through P port or R port on both sides of the manifold. VT VP VG Applicable solenoid valve VZ312R--M5-Q VZ322R--M5-Q Applicable blank plate assembly DXT200-8-1A VQ VQZ Note: This valve series is now only available with DIN connector. Station L1 L2 L3 2 62 53 47 3 78 69 63 L plug connector (L) 4 94 85 79 5 110 101 95 6 126 117 111 7 142 133 127 8 158 149 143 9 174 165 159 10 190 181 175 11 206 197 191 12 222 213 207 13 238 229 223 M plug connector (M) 14 254 245 239 15 270 261 255 16 286 277 271 17 302 293 287 18 318 309 303 19 334 325 319 20 350 341 335 DIN terminal (D) : with indicator light and surge voltage suppressor 2.4-23 VZ300 For External Pilot 40R Type Manifold: Bottom Ported Grommet (G) (H) How to Order E VV3Z3 40R 05 2 M5 Q Stations 02 2 stations 20 20 stations P, R port thread Ordering source area code Code E N areas Japan,Asia Australia,England Europe North America A port size M5 M5 X 0.8 F N T Rc (PT) G (PF) NPT NPTF Note) If more than 9 stations, supply and exhaust air through P port or R port on both sides of the manifold. Note) If > 9 stations, supply and exhaust air through P port or R port on both sides of the manifold. Note: This valve series is now only available with DIN connector. Applicable solenoid valve VZ314R--Q VZ324R--Q Applicable blank plate assembly DXT200-8-1A Station L1 L2 L3 2 62 53 47 3 78 69 63 L plug connector (L) 4 94 85 79 5 110 101 95 6 126 117 111 7 142 133 127 8 158 149 143 9 174 165 159 10 190 181 175 11 206 197 191 12 222 213 207 13 238 229 223 M plug connector (M) : with indicator light and surge voltage suppressor 2.4-24 14 254 245 239 15 270 261 255 16 286 277 271 17 302 293 287 18 318 309 303 DIN terminal (D) 19 334 325 319 20 350 341 335 VZ300 For External Pilot 40R Type Manifold: Bottom Ported Grommet (G), (H) SY How to Order E VV3Z3 40R 2 01 Q Ordering source area code Code E N areas Japan,Asia Australia,England Europe North America 02 2 stations 20 20 stations A port size 18 01 SYJ P, R port thread Stations Note) If > 9 stations, supply and exhaust air through P port or R port on both sides of the manifold. VK F N T Rc (PT) G (PF) NPT NPTF Note) If > 9 stations, supply and exhaust air through P port or R port on both sides of the manifold. VZ VT VT VP Note: This valve series is now only available with DIN connector. Applicable solenoid valve VZ314R--Q VZ324R--Q VG Applicable blank plate assembly DXT200-8-1A VQ VQZ Station L1 L2 L3 2 63 54 48 3 80 71 65 L plug connector (L) 4 97 88 82 5 114 105 99 6 131 122 116 7 148 139 133 8 165 156 150 9 182 173 167 10 199 190 184 11 216 207 201 12 233 224 218 13 250 241 235 M plug connector (M) 14 267 258 252 15 284 275 269 16 301 292 286 17 318 309 303 18 335 326 320 19 352 343 337 20 369 360 354 DIN terminal (D) : with indicator light and surge voltage suppressor 2.4-25 VZ300 For External Pilot 40R Type Manifold: Side Ported Grommet (G), (H) How to Order E VV3Z3 40R 05 1 M5 Q P, R port thread Stations Ordering source area code Code E N areas Japan,Asia Australia,England Europe North America 02 2 stations 20 20 stations A port size M5 M5 X 0.8 Note) If > 9 stations, supply and exhaust air through P port or R port on both sides of the manifold. F N T Rc (PT) G (PF) NPT NPTF Note) If > 9 stations, supply and exhaust air through P port or R port on both sides of the manifold. Applicable solenoid valve VZ314R--Q VZ324R--Q Applicable blank plate assembly DXT200-8-1A Note: This valve series is now only available with DIN connector. Station L1 L2 L3 2 62 53 47 3 78 69 63 L plug connector (L) 4 94 85 79 5 110 101 95 6 126 117 111 7 142 133 127 8 158 149 143 9 174 165 159 10 190 181 175 11 206 197 191 12 222 213 207 13 238 229 223 M plug connector (M) : with indicator light and surge voltage suppressor 2.4-26 14 254 245 239 15 270 261 255 16 286 277 271 17 302 293 287 18 318 309 303 DIN terminal (D) 19 334 325 319 20 350 341 335 VZ300 For External Pilot 40R Type Manifold: Side Ported How to Order Grommet (G), (H) E VV3Z3 40R 05 1 01 Stations 02 Ordering source area code Code E N 20 areas Japan,Asia Australia,England Europe North America SYJ P, R port thread 2 stations 20 stations A port size 18 01 SY Q Note) If > 9 stations, supply and exhaust air through P port or R port on both sides of the manifold. F N T Rc (PT) G (PF) NPT NPTF Note) If > 9 stations, supply and exhaust air through P port or R port on both sides of the manifold. VK VZ VT VT VP Applicable solenoid valve VZ314R--Q VZ324R--Q VG Applicable blank plate assembly DXT200-8-1A VQ VQZ Note: This valve series is now only available with DIN connector. Station L1 L2 L3 2 63 54 48 3 80 71 65 L plug connector (L) 4 97 88 82 5 114 105 99 6 131 122 116 7 148 139 133 8 165 156 150 9 182 173 167 10 199 190 184 11 216 207 201 12 233 224 218 13 250 241 235 M plug connector (M) 14 267 258 252 15 284 275 269 16 301 292 286 17 318 309 303 18 335 326 320 19 352 343 337 20 369 360 354 DIN terminal (D) : with indicator light and surge voltage suppressor 2.4-27 VZ300 For External Pilot 40R Type Manifold: Side Ported Grommet (G), (H) How to Order E VV3Z3 40R 05 1 C6 Q Stations Ordering source area code Code E N 02 2 stations 20 20 stations P, R port thread A port size areas Japan,Asia Australia,England Europe North America C4 ø4 One-touch fitting C6 ø6 One-touch fitting F N T Rc (PT) G (PF) NPT NPTF Note) If > 9 stations, supply and exhaust air through P port or R port on both sides of the manifold. Note) If > 9 stations, supply and exhaust air through P port or R port on both sides of the manifold. Applicable solenoid valve VZ314R--Q VZ324R--Q Applicable blank plate assembly DXT200-8-1A Note: This valve series is now only available with DIN connector. Station L1 L2 L3 2 58 49 43 3 74 65 59 L plug connector (L) 4 90 81 75 5 106 97 91 6 122 113 107 7 138 129 123 8 154 145 139 9 170 161 155 10 186 177 171 11 202 193 187 12 218 209 203 13 234 225 219 M plug connector (M) : with indicator light and surge voltage suppressor 2.4-28 14 250 241 235 15 266 257 251 16 282 273 267 17 298 289 283 18 314 305 299 DIN terminal (D) 19 330 321 315 20 346 337 331 3 Port Body Ported, Base Mounted Rubber Seal VZ500 Series How to Order Port size Ordering source area code Body Ported Base Mounted SY F: With foot bracket SYJ 5 O pt io n Q 01 VP VG Q D Thread Actuation 1 N T F Port size Rc (PT) NPT NPTF G (PF) 01: 1 8 02: 1 4 –: Without sub-plate With sub-plate With sub-plate Normally open 2 Manual override –: Non-locking push style Body option B: Locking slotted style C: Locking knob style M: Common exhaust R: External pilot style(1) (pilot and main valve) style Indicator light and surge voltage suppressor – Z∗ S Note 1) VZ52R is only for manifold. Order Made 100V AC 50/60Hz 200V AC 50/60Hz 110V AC 50/60Hz 220V AC 50/60Hz 24V DC 12V DC Others None Indicator light and surge voltage suppressor Surge voltage suppressor ∗Not available for DOZ Rated voltage 1 2 3 4 5 6 9 VT VT Normally closed –: Individual pilot exhaust style VZ e iz rt s tri ec D Note) · The bracket is not assembled. · Except for external pilot. Po lta vo VZ5 1 4 5 El ed at VZ5 1 2 ca In l e vo dic ntr lta at y ge or su ligh pp t a M re nd an ss s ua or ur ge lo ve rri de ge VK Bo dy Ac tu at io n E N R - areas Japan, Asia Australia, England Europe North America op tio n Code Option 18 01 Electrical entry DIN terminal D:With connector Contact SMC for other voltages (9) DO: Without connector 2.4-29 VQ VQZ VZ500 Specifications Low Power Consumption: 1.8WDC Applicable for Vacuum Use –100kPa 500R: External pilot style Fluid Operating pressure range Internal pilot (MPa) Ambient and fluid temperature (˚C) Response time ms {0.5MPa} (1) Max. operating frequency (Hz) Effective area Manual override 500M: Central exhaust style It is not necessary to take exhaust measures for the pilot valve for environmental protection. Pilot exhaust Lubrication Mounting position Impact/vibration resistance (m/s2) (3) Protection structure 500R: External pilot style Can be used for universal porting. Max. 50 20 or less 10 See below Non-locking push style, Locking slotted style, Locking knob style Individual pilot exhaust, Common exhaust (pilot and main valve) Non-lube Free 300/50 Dust proof (2) Exhaust measures for the pilot valve are unnecessary Can also be used as a selector valve of a divider valve. Air 0.15 to 0.7 Note 1) According to dynamic performance test of JIS B8374-1981. (Coil temperature 20˚C, rated voltage, without surge voltage suppressor) Note 2) When operating the locking style manually, apply torque of 0.2Nm or less. Note 3) Impact resistance: No malfunction from test using drop impact tester, to axis and right angle directions of main valve and armature, each one time when energized and de-energized. (Value in the initial stage.) Vibration resistance: No malfunction from test with 8.3 to 2000Hz 1 sweep, to axis and right angle directions of main valve and armature, each one time when energized and de-energized. (Value in the initial stage.) Solenoid Specifications ∗Option DIN Terminal (D) Electrical entry Coil rated voltage V AC50/60Hz DC 100, 200, 24∗, 48∗, 110∗, 220∗ 24, 6∗, 12∗, 48∗ –15 to +10% of rated voltage DC 1.8(With light 2.1) [24V DC: 75(With light 87.5) ] Allowable voltage % Power consumption W [Current mA] (1) Body Ported Apparent power VA [Current mA] (1) Inrush 4.5/50Hz, 4.2/60Hz Holding 3.5/50Hz, 3/60Hz 100V AC: 45/50Hz, 42/60Hz 200V AC: 22.5/50Hz, 21/60Hz AC Surge voltage suppressor Indicator light 100V AC: 35/50Hz, 30/60Hz 200V AC: 17.5/50Hz, 15/60Hz DC: Diode, AC: ZNR DC: LED(red), AC: Neon light Note 1) At rated voltage Effective Area and Weight Valve Body Ported Base Mounted (With sub-plate) Base Mounted Actuation VZ512 VZ522 VZ514 VZ524 N.C. N.O. N.C. N.O. Port size Effective area (mm2) (Nl/min) Weight (g) 18 9.0 (490.75) 110 18,14 9.0 (490.75) 160 (Without sub-plate 110) Option Description Foot bracket Refer to p.2.4-34 to 2.4-44 for manifold use. 2.4-30 Part No. DXT201-19-1A Note With screw (for VZ52) VZ500 External Pilot: VZ500R This obtains external pressure for the pilot valve separarely from the main valve pressure. It can be operated with a low pressure line with a vacuum (to –100kPa) or below 0.15MPa. JIS symbol VZ51R SY Specifications SYJ Applicable model Base mounted (VZ314R, VZ324R) Main pressure Operating pressure range –100kPa to 0.7 MPa External pilot pressure 0.15 to 0.7 VK Note 1) Refer to the p.2.4-34 for manifold base. VZ VZ52R VT Note 2) In the case of the body ported style, the pilot style (VZ32R) is used exclusively on a manifold. An external pilot style that can be used individually is available as an Order Made specification. VT VP VG VQ Construction VQZ N.C. N.O. Component Parts No. q w e r t y Description Body Piston plate End cover Piston Spool valve ass’y Spool spring Replacement Parts Material Aluminium die cast Resin Aluminium die cast Resin Note Platinum silver Black Black No. Description Material u Sub-plate Aluminium die cast i o Solenoid ass'y O ring Epoxy, stainless steel NBR Part No. DXT201-2-1P DXT201-2-2P Note 13 X 11 X 1 Common with VZ100 18 14 Stainless steel 2.4-31 VZ500 Body Ported Grommet (G), (H) VZ52-G H-01 Note: This valve series is now only available with DIN connector. L plug connector (L) VZ52-L-01 M plug connector (M) VZ52-M-01 : with indicator light and surge voltage suppressor 2.4-32 DIN terminal (D) VZ52-D-01-Q VZ500 Base Mounted Grommet (G), (H) 01 VZ54- G H - 02 SY SYJ Note: This valve series is now only available with DIN connector. VK VZ VT VT VP VG VQ VQZ L plug connector (L) 01 VZ54-L- 02 M plug connector (M) VZ54-M- 01 02 DIN terminal (D) VZ54-D- 01 02 -Q : with indicator light and surge voltage suppressor 2.4-33 Series VZ500 Manifold Manifold Specifications Model Internal pilot External pilot Manifold P(SUP)/R(EXH) style Stations Position A port piping Direction P/R port Port size Valve effective area mm2(Cv) (2) Page on How to Order 20- 1 1 402 412 1 – 41R2 Single base/B mount Common SUP/Common EXH 2 to 20 stations Base Valve Base Bottom Top Bottom Valve Top A port 18 14 18 14 18 18 18 18 X port (1) Body ported VZ52/VZ52R – M5 – 10.6(0.59) M5 4141R- 1 1 Base Side 14 18 C6 ø6 One-touch fitting C8 ø8 One-touch fitting M5 – 1 8 : 9.2(0.51) Base mounted VZ54/VZ54R Internal pilot External pilot 2121R- – – p.2.4-35 – p.2.4-36 p.2.4-41 10.2(0.57) 10.2(0.57) p.2.4-37 – p.2.4-38 p.2.4-42 C6: 8.8(0.49) C8: 10(0.56) p.2.4-39, 2.4-40 p.2.4-43, 2.4-44 Note 1) Only for external pilot Note 2) Value at manifold base mounted How to Order Manifold Base To order valves and blank plate assembly mounted onto the manifold, list valves and blank plate assembly with manifold base. (Sample) VV3Z5-20-031-Q···1 pc. (Manifold base) VZ512-5D-01-Q·····2 pcs. (Valve) DXT201-15-1A ······1 pc. (Blank plate ass’y) Option Combinations of solenoid valve, manifold gasket and manifold base Blank plate Assembly Body ported (VZ52) DXT201-15-1A Base mounted (VZ54) Applicable base Applicable base VV3Z5-20-1 VV3Z5-21-1 VV3Z5-21R-1 2.4-34 Manifold base Sub-plate VV3Z5-40-2 VV3Z5-41-2 VV3Z5-41-1 VV3Z5-41R-2 VV3Z5-41R-1 Manifold base VZ500 For Internal Pilot 20 Type Manifold: Top Ported Grommet (G), (H) How to Order E VV3Z5 20 E N areas Japan,Asia Australia,England Europe North America 02 2 stations 20 20 stations Note) If > 6 stations, supply air to P port on both sides of the manifold and exhaust from R port on both sides of the manifold. SY Q Stations Ordering source area code Code 05 1 P, R port thread SYJ 00F 00N 00T VK Rc (PT) G (PF) NPT NPTF Note) If more than 6 stations, supply air to P port on both sides of the manifold and exhaust from R port on both sides of the manifold. VZ VT VT Note: This valve series is now only available with DIN connector. Applicable solenoid valve VZ512--01-Q VZ512M--01-Q VZ522--01-Q VZ522M--01-Q VP VG Applicable blank plate assembly DXT201-15-1A VQ VQZ Station L1 L2 2 59 49 3 78 68 4 97 87 L plug connector (L) 5 116 106 6 135 125 7 154 144 8 173 163 9 192 182 10 211 201 11 230 220 12 249 239 13 268 258 M plug connector (M) 14 287 277 15 306 296 16 325 315 17 344 334 18 363 353 19 382 372 20 401 391 DIN terminal (D) : with indicator light and surge voltage suppressor 2.4-35 VZ500 For Internal Pilot 21 Type Manifold: Top Ported Grommet (G), (H) How to Order E VV3Z5 Ordering source area code Code E N areas Japan,Asia Australia,England Europe North America 21 05 1 Q Stations P, R port thread 02 2 stations 20 20 stations 00F 00N 00T Rc (PT) G (PF) NPT NPTF Note) If more than 9 stations, supply air to P port on both sides of the manifold and exhaust from R port on both sides of the manifold. Note) If there are more than 9 stations, supply air to P port on both sides of the manifold and exhaust from R port on both sides of the manifold. Applicable solenoid valve VZ512--01-Q VZ512M--01-Q VZ522--01-Q VZ522M--01-Q Applicable blank plate assembly DXT201-15-1A Note: This valve series is now only available with DIN connector. Station L1 L2 2 61 49 3 80 68 4 99 87 L plug connector (L) 5 118 106 6 137 125 7 156 144 8 175 163 9 194 182 10 213 201 11 232 220 12 251 239 13 270 258 M plug connector (M) : with indicator light and surge voltage suppressor 2.4-36 14 289 277 15 308 296 16 327 315 17 346 334 18 365 353 DIN terminal (D) 19 384 372 20 403 391 VZ500 For Internal Pilot 40 Type Manifold: Bottom Ported Grommet (G), (H) How to Order E VV3Z5 Ordering source area code Code E N areas Japan,Asia Australia,England Europe North America 40 05 2 01 SY Q Stations SYJ P, R port thread 02 2 stations 20 20 stations A port size 01 18 Note) If > 6 stations, supply air to P port on both sides of the manifold and exhaust from R port on both sides of the manifold. F N T Rc (PT) G (PF) NPT NPTF Note) If more than 6 stations, supply air to P port on both sides of the manifold and exhaust from R port on both sides of the manifold. VK VZ VT VT VP Applicable solenoid valve VZ514--Q VZ514M--Q VZ524--Q VZ524M--Q VG Note: This valve series is now only available with DIN connector. Applicable blank plate assembly DXT201-15-1A VQ VQZ Station L1 L2 2 59 49 3 78 68 4 97 87 L plug connector (L) 5 116 106 6 135 125 7 154 144 8 173 163 9 192 182 10 211 201 11 230 220 12 249 239 13 268 258 M plug connector (M) 14 287 277 15 306 296 16 325 315 17 344 334 18 363 353 19 382 372 20 401 391 DIN terminal (D) : with indicator light and surge voltage suppressor 2.4-37 VZ500 For Internal Pilot 41 Type Manifold: Bottom Ported Grommet (G), (H) How to Order E VV3Z5 Ordering source area code Code E N areas Japan,Asia Australia,England Europe North America 41 05 2 01 Q Stations P, R port thread 02 2 stations 20 20 stations F N T Rc (PT) G (PF) NPT NPTF Note) If more than 9 stations, supply air to P port on both sides of the manifold and exhaust from R port on both sides of the manifold. A port size 01 Note) If > 9 stations, supply air to P port on both sides of the manifold and exhaust from R port on both sides of the manifold. 18 Note: This valve series is now only available with DIN connector. Applicable solenoid valve VZ514--Q VZ514M--Q VZ524--Q VZ524M--Q Applicable blank plate assembly DXT201-15-1A Station L1 L2 2 61 49 3 80 68 4 99 87 L plug connector (L) 5 118 106 6 137 125 7 156 144 8 175 163 9 194 182 10 213 201 11 232 220 12 251 239 13 270 258 M plug connector (M) : with indicator light and surge voltage suppressor 2.4-38 14 289 277 15 308 296 16 327 315 17 346 334 18 365 353 DIN terminal (D) 19 384 372 20 403 391 VZ500 For Internal Pilot 41 Type Manifold: Side Ported How to Order E VV3Z5 41 E N areas Japan,Asia Australia,England Europe North America 01 Q SY Grommet (G) (H) SYJ Stations Ordering source area code Code 05 1 02 2 stations 20 20 stations P, R port thread Rc (PT) G (PF) NPT NPTF Note) If more than 9 stations, supply air to P port on both sides of the manifold and exhaust from R port on both sides of the manifold. A port size 18 01 VK F N T Note) If > 9 stations, supply air to P port on both sides of the manifold and exhaust from R port on both sides of the manifold. VZ VT VT VP Applicable solenoid valve VZ514--Q VZ514M--Q VZ524--Q VZ524M--Q VG Applicable blank plate assembly DXT201-15-1A VQ VQZ Note: This valve series is now only available with DIN connector. Station L1 L2 2 61 49 3 80 68 4 99 87 L plug connector (L) 5 118 106 6 137 125 7 156 144 8 175 163 9 194 182 10 213 201 11 232 220 12 251 239 13 270 258 M plug connector (M) 14 289 277 15 308 296 16 327 315 17 346 334 18 365 353 19 384 372 20 403 391 DIN terminal (D) : with indicator light and surge voltage suppressor 2.4-39 VZ500 For Internal Pilot 41 Type Manifold: Side Ported Grommet (G), (H) How to Order E VV3Z5 41 E N C6 Q Stations Ordering source area code Code 05 1 areas Japan,Asia Australia,England Europe North America P, R port thread 02 2 stations 20 20 stations A port size C6 ø6 One-touch fitting C8 ø8 One-touch fitting Note) If > 9 stations, supply air to P port on both sides of the manifold and exhaust from R port on both sides of the manifold. F N T Rc (PT) G (PF) NPT NPTF Note) If more than 9 stations, supply air to P port on both sides of the manifold and exhaust from R port on both sides of the manifold. Applicable solenoid valve VZ514--Q VZ514M--Q VZ524--Q VZ524M--Q Applicable blank plate assembly DXT201-15-1A Note: This valve series is now only available with DIN connector. Station L1 L2 2 61 49 3 80 68 4 99 87 L plug connector (L) 5 118 106 6 137 125 7 156 144 8 175 163 9 194 182 10 213 201 11 232 220 12 251 239 13 270 258 M plug connector (M) : with indicator light and surge voltage suppressor 2.4-40 14 289 277 15 308 296 16 327 315 17 346 334 18 365 353 DIN terminal (D) 19 384 372 20 403 391 VZ500 For External Pilot 21R Type Manifold: Top Ported How to Order SY E VV3Z5 Ordering source area code Code E N areas Japan,Asia Australia,England Europe North America 21R 05 1 Stations 02 2 stations 20 20 stations Q Grommet (G), (H) SYJ P, R port thread 00F 00N 00T Rc (PT) G (PF) NPT NPTF Note) If more than 9 stations, supply and exhaust air through P port or R port on both sides of the manifold. Note) If > 9 stations, supply and exhaust air through P port or R port on both sides of the manifold. VK VZ VT VT VP Applicable solenoid valve VZ512R--Q VZ522R--Q VG Applicable blank plate assembly DXT201-15-1A VQ VQZ Note: This valve series is now only available with DIN connector. Station L1 L2 2 61 49 3 80 68 4 99 87 L plug connector (L) 5 118 106 6 137 125 7 156 144 8 175 163 9 194 182 10 213 201 11 232 220 12 251 239 13 270 258 M plug connector (M) 14 289 277 15 308 296 16 327 315 17 346 334 18 365 353 19 384 372 20 403 391 DIN terminal (D) : with indicator light and surge voltage suppressor 2.4-41 VZ500 For External Pilot 41R Type Manifold: Bottom Ported Grommet (G), (H) How to Order E VV3Z5 41R 05 2 01 Stations Ordering source area code Code E N areas Japan,Asia Australia,England Europe North America 02 2 stations 20 20 stations P, R port thread A port size 01 Q 18 F N T Rc (PT) G (PF) NPT NPTF Note) If more than 9 stations, supply and exhaust air through P port or R port on both sides of the manifold. Note) If > 9 stations, supply and exhaust air through P port or R port on both sides of the manifold. Note: This valve series is now only available with DIN connector. Applicable solenoid valve VZ514R--Q VZ524R--Q Applicable blank plate assembly DXT201-15-1A Station L1 L2 2 61 49 3 80 68 4 99 87 L plug connector (L) 5 118 106 6 137 125 7 156 144 8 175 163 9 194 182 10 213 201 11 232 220 12 251 239 13 270 258 M plug connector (M) : with indicator light and surge voltage suppressor 2.4-42 14 289 277 15 308 296 16 327 315 17 346 334 18 365 353 DIN terminal (D) 19 384 372 20 403 391 VZ500 For External Pilot 41R Type Manifold: Side Ported How to Order Grommet (G), (H) E VV3Z5 41R 05 1 01 Stations Ordering source area code Code E N areas Japan,Asia Australia,England Europe North America 02 2 stations 20 20 stations SY SYJ P, R port thread F N T Rc (PT) G (PF) NPT NPTF Note) If more than 9 stations, supply air to P port on both sides of the manifold and exhaust from R port on both sides of the manifold. A port size 18 01 Q Note) If > 9 stations, supply and exhaust air through P port or R port on both sides of the manifold. VK VZ VT VT VP Note: This valve series is now only available with DIN connector. Applicable solenoid valve VZ514R--Q VZ524R--Q VG Applicable blank plate assembly DXT201-15-1A VQ VQZ Station L1 L2 2 61 49 3 80 68 4 99 87 L plug connector (L) 5 118 106 6 137 125 7 156 144 8 175 163 9 194 182 10 213 201 11 232 220 12 251 239 13 270 258 M plug connector (M) 14 289 277 15 308 296 16 327 315 17 346 334 18 365 353 19 384 372 20 403 391 DIN terminal (D) : with indicator light and surge voltage suppressor 2.4-43 VZ500 For External Pilot 41R Type Manifold: Side Ported Grommet (G), (H) How to Order E VV3Z5 41R 05 1 C6 Stations Ordering source area code Code E N areas Japan,Asia Australia,England Europe North America 02 2 stations 20 20 stations Q P, R port thread F N T A port size C6 ø6 One-touch fitting C8 ø8 One-touch fitting Note) If > 9 stations, supply and exhaust air through P port or R port on both sides of the manifold. Rc (PT) G (PF) NPT NPTF Note) If more than 9 stations, supply air to P port on both sides of the manifold and exhaust from R port on both sides of the manifold. Applicable solenoid valve VZ514R--Q VZ524R--Q Applicable blank plate assembly DXT201-15-1A Note: This valve series is now only available with DIN connector. Station L1 L2 2 61 49 3 80 68 4 99 87 L plug connector (L) 5 118 106 6 137 125 7 156 144 8 175 163 9 194 182 10 213 201 11 232 220 12 251 239 13 270 258 M plug connector (M) : with indicator light and surge voltage suppressor 2.4-44 14 289 277 15 308 296 16 327 315 17 346 334 18 365 353 DIN terminal (D) 19 384 372 20 403 391