Preview only show first 10 pages with watermark. For full document please download

Wan-sub-01a Armor Wall Mount Condensing Water Heater Submittal Sheet

   EMBED


Share

Transcript

ARMOR Wall Mount Condensing Water Heater Submittal Sheet WAN-Sub-01a ARMOR WALL MOUNT CONDENSING WATER HEATER JOB NAME ______________________________________________________________________ LOCATION ______________________________________________________________________ ENGINEER____________________________________________________________________ WHOLESALER __________________________________________________________________ MECH. CONTRACTOR ___________________________________________________________ MODEL NO. _____________________________________________________________________ TYPE GAS ______________________________________________________________________ Btu/hr INPUT_____________________________________________________________________ RECOVERY RATE IN GPH_______________________________________@________°F RISE NOTES Standard Features Smart SystemTM Features > SMART SYSTEM Digital Operating Control > AHRI Certified 96% Thermal Efficiency > Multi Color Graphic LCD Display > Wall Mounted Models > Built in Cascading Sequencer for up to 8 Water Heaters > Modulating Burner with 5:1 Turndown > Multiple Size Water Heater Cascade > Direct-Spark Ignition > Lead Lag > Low NOx Operation > Efficiency Optimization > Building Management System Integration > Sealed Combustion > Modbus Communication (Optional) > Low Gas Pressure Operation > 0-10 VDC Input to Control Modulation or Set point > Vertical & Horizontal Direct-Vent > 0-10 VDC Modulation Rate Output > PVC, CPVC, Polypropylene or SS up to 100 Feet > 0-10 VDC Input to Enable/Disable call for heat > PVC/CPVC Sidewall Vent Termination > Access to BMS Settings Through Graphic LCD Display > Stainless Steel Heat Exchanger > Low Water Flow Safety Control & Indication > Inlet & Outlet Temperature Sensors & Readout > All Welded Construction, Gasketless Design > Flue Temperature Sensor > 160 psi Working Pressure > Water Heater Pump Control > Natural to L.P. Conversion Kit > Pump Delay with Freeze Protection > All Bronze Circulating Pump > Pump Exercise > Flow Switch > Night Setback > Temperature & Pressure Relief Valve > Building Recirculation Loop Pump Control > Time Clock > Tank Sensor > Maintenance Reminder > Adjustable High Limit w/ Manual Reset > Ability to program installer name and number into the > Automatic Reset High Limit product as service contact > Condensate Trap > High Voltage Terminal Strip > Zero Clearances to Combustible Material > 120 VAC / 60 Hertz / 1 Phase Power Supply > 5 Year Limited Warranty (See Warranty for Details) > Pump Control Contacts > Water Heater Pump Control Contacts > 1 Year Parts Warranty (See Warranty for Details) > Building Recirculation Pump Control Contacts > Low Voltage Terminal Strip > 24 VAC Louver Relay > Louver Proving Switch Contacts > Flow Switch Contacts > Alarm on Any Failure Contacts > Runtime Contacts > Tank Sensor Contacts > Cascade Contacts > 0-10 VDC BMS External Control Contact > 0-10 VDC Boiler Rate Output Contacts Optional Equipment Alarm Bell Condensate Neutralization Kit Concentric Vent Kit (3” PVC/CPVC only) ModBus Communications BMS Gateway to LON or BacNet > SMART SYSTEM PC Software ARMOR WALL MOUNT Condensing Water Heater Dimensions & Specifications 16" FLUE 7-1/2" ELECTRICAL CONNECTIONS 8" H I RELIEF VALVE GAS AIR INTAKE A WATER OUTLET C D CONDENSATE TRAP WATER INLET E F 18-1/2" 1-3/4" G 2-3/4" 15-1/2" B TOP SIDE Model Btu/hr GPH @ Number Input 100° Rise A B C D 7” E 13” CONDENSATE LINE BOTTOM F 3-1/2” G H 2-3/4” 5-1/2” I 6” WAN125PM 125,000 144 29-1/4” 18” 13” WAN200PM 199,999 233 29-1/4” 25” 20” 14” 11-3/4” 3-1/2” 1-1/2” 5-1/2” 13” Gas Water Air Vent Shipping Conn. Conn. Inlet Size Wt. (lbs.) 1/2” 1” 1/2” 1-1/4” 3” 3” 145 3” 3” 177 Lochinvar, LLC 300 Maddox Simpson Parkway Lebanon, Tennessee 37090 P: 615.889.8900 / F: 615.547.1000 Lochinvar.com 5/15—Printed in U.S.A.