Setting the Temperature The temperature is controlled by inserting the provided Allen wrench into the front of the Thermostatic mixer. Turning the wrench left increases the temperature, while turning it right decreases the temperature. H C Nirvana/Bridge 03302-019 24” Towel Bar Bridge Commercial Single Hole Faucet with Radius Technology Operation Once installed, the bridge Faucet should activate when your hand is placed anywhere within 2 inches of the faucet. If installed properly, the faucet should shut off in 3 seconds once you take your hand away. The faucet shuts off automatically after 15 seconds to save water. Important: (1) The sensor field is conducted through the sensor wire connection to the metal parts of the spout and will perpetuate though any other metal components that make contact. (2) The sensor field can also perpetuate through other metal at close proximity to the faucet. ¼” is usually enough space to keep this from happening. (3) Isolation spacers are extremely important and required when mounting to a metal sinks. Stone, granite, and marble counter tops also require spacers. DO NOT throw away the spacers, use them for all installations. waterdecor 3579 East Foothill Boulevard • Suite 418 Pasadena • California 91107 Tel: 877.222.9644 • Fax: 626.744.0377 E-mail: [email protected] Copyright © MMVI Water Decor Inc. All Rights Reserved waterdecor INSTALLATION GUIDE PARTS INCLUDED IN PACKAGE: 4 :: Grounding the Faucet. • Please call waterdecor at 877.222.9644 immediately if there are any missing parts. It is IMPORTANT that a robust earth ground connection is made. Improper grounding will adversely affect the performance of the faucet. 4-1. Connect both grounding wires to the U-tab located on the brass fitting on the input side of the Radius™ valve. Spout Assembly 4-2. Install the Earth Ground Wire onto the cold water pipe in between the angle stop and the wall ring and install the Drain Ground Wire onto the drain. Black Plastic Spacer w/ O-rings Plastic Hose for alternate installation Black Plastic Bottom Spacer w/ O-rings NOTE: If a metal pipe ground connection cannot be made or plastic piping is used, the earth ground connection can be made through a conduit ground. Drain Mounting Washer Battery Pack Note: Batteries not included Mounting Nut Sensor Terminal Mounting Nut Radius™ Valve 5 :: Mounting the Battery Pack 5-1. Open the battery pack by unscrewing the screws on the front side of the assembly. 5-2. Remove mounting hardware from within the battery pack. 5-3. Mount battery pack to the wall using the screws, or adhesive provided. Thermostatic Mixer Note: Mixer includes rubber washer and Allen wrench 5-4. Insert (4) D Cell batteries (not included). 5-5. Close the battery pack. 5-6. Connect Battery pack to Radius™ valve. Drain Grounding Wire Earth Grounding Wire 3-2. Attach Radius™ valve to bottom of the threaded shank and attach REQUIRED TOOLS AND SUPPLIES: the sensor wire to the sensor terminal. • Adjustable Wrench • Flat Screwdriver Sensor Terminal • 12” Pipe Wrench • (4) D-cell Alkaline Batteries IMPORTANT: 3-3. Tighten Thermostatic Mixer to the Radius™ valve. • Shut off water supply before beginning installation! • The Spout assembly is heavy, please handle with care. • This is a space-limited job, always wear goggles and watch for possible falling objects that may cause damage to the parts or cause bodily injury. • Do NOT use a pipe wrench on finished surfaces. It will void the finish warranty. Thermostatic Mixer 3-4. Connect supply lines to the mixer. Connect supply lines to angle stops. Note: Supply lines and angle stops are not included. • Do NOT use “Plumber’s Putty” or any oil based sealants. Use of these materials may discolor the surface and WILL void the finish warranty. Technical Data: • Operation Pressure: 7.25 – 125 psi • Maximum Flow: 1.0 gpm • Power Voltage: 6 VDC • Power Supply: “D” cell Batteries or optional AC adapter • Battery Life: Approximately 3 years • Sensor Range: 2 inches INSTALLATION: Flange Washer 2 :: Installing the Faucet 1 :: Installing the drain into sink. Drain Place black plastic spacer with O-rings onto the bottom of the Spout Flange. 1-1. Sink 2-1. Sink Unscrew drain from drain assembly. Keep the flange washer in place. Remove the cone washer and the plastic washer. Unscrew the nut. Cone Rubber Washer Plastic Washer 1-2. 2-2. Place the spout onto the counter top. 2-3. Slide Bottom Plastic Spacer with O-ring onto threaded shank, along Install the drain with flange washer from above the sink. Nut Pop-Up Connector 1-3. Place cone washer on the bottom of the drain. Make sure that the cone points upward and is inserted Tailpiece evenly into the bottom opening of the sink. 1-4. Install the plastic washer and tighten nut to secure the drain. 1-5. Unscrew the tailpiece from the Pop-Up connector. Insert the tailpiece with the mounting washer. Secure faucet to counter with nut. into the drain pipe (tail piece is part of p-trap assembly). 1-6. Install the Pop-Up connector by connecting onto the bottom of the drain. NOTE: Make sure not to overtighten. 1-7. Slide the tailpiece and connect it to Pop-Up. 1-8. Slide Large Clamp with Drain Grounding Wire onto tailpiece. Tighten the Clamp. 1-9. Secure all drain connections. 3 :: Connecting Radius™ Valve and Mixer 3-1. Slide the Sensor Terminal onto the threaded shank on the bottom of the faucet and tighten with the second mounting nut. Sensor Terminal