Preview only show first 10 pages with watermark. For full document please download

Wave Automated Home Control System Wa01 Installation Manual

   EMBED


Share

Transcript

AUTOMATED HOME CONTROL SYSTEM WAVE °C 32 55 : 10 INSTALLATION MANUAL WA01 1. Legend of symbols.......................................................3 2. Intended use and restrictions.......................................3 2.1 Intended use........................................................3 2.2 Usage restrictions...............................................3 3. Regulatory framework.................................................4 4. Description..................................................................4 4.1 230V a.c. Control system...................................4 4.2 Technical Data....................................................4 4.3 General Description............................................5 5. Installation..................................................................6 5.1 Preliminary checks.............................................6 5.2 Tools and materials.............................................6 5.3 Dimensions, centre distance and securing holes.7 5.4 Introduction to the functioning logic...................8 5.5 Connecting cables...............................................9 5.6 Wall mounting...................................................10 6. Programming............................................................11 6.1 Description of commands and the display.11 6.2 Browsing the menu............................................12 6.3 Menu Structure - Main.......................................13 6.3.1 Menu-Settings-Language.........................14 6.3.2 Menu -Settings-Temperature...................15 6.3.3 Menu -Settings-Screensaver....................15 2 6.4 Menu-Modify user.............................................16 6.5 Menu-New user..................................................18 6.6 Menu-Remove user............................................19 6.7 Menu-TX Radio..................................................20 6.8 Menu-Timer.......................................................21 6.9 Menu-Alarm clock.............................................22 6.10 Menu-Thermostat............................................23 6.11 Menu-Clock......................................................24 6.12 Menu-Key functions.........................................24 6.13 Menu-Password...............................................25 7.Maintenance........................................................28 8.Phasing out and Disposal.....................................28 9.Manufacturer’s statement....................................29 The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning EN INDEX EN The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning “IMPORTANT INSTALLATION, SAFETY INSTRUCTIONS” “CAUTION: IMPROPER INSTALLATION MAY CAUSE SERIOUS DAMAGE, FOLLOW ALL INSTALLATION INSTRUCTIONS CAREFULLY” “THIS MANUAL IS ONLY FOR PROFESSIONAL OR QUALIFIED INSTALLERS” 1 Legend of symbols This symbol tells you to read the section with particular care. This symbol tells you that the sections concern safety issues. This symbol tells you what to say to the end-users. 2 Intended use and restrictions 2.1 Intended use Automated home control system featuring a stand alone function – will interface with the WI08 digital, electronic card. 2.2 Restrictions Secure the apparatus in areas free from accidental impacts. 3 3 Reference Standards 4 Description 4.1 230V a.c. control system Home automation control system powered by 120-230V a.c.; 50÷60 frequency. CAME projects and produces entirely in Italy. It fi ts all embedded door wall boxes. 4.2 Technical features Control panel Power supply: 120/230V - 50÷60 Hz. Max Power: 30 mA AC Power draw when idle: 20 mA AC Max power load of accessories: 5A 230V AC/24V DC (resistant) ; 1,5A 230V AC (inductive). Protection rating: IP40 Isolation class: II Temperature variance: ± 1°C Material: ABS Support /PC/ - PA6 – PMMA Plate Radio Frequency: 433.92 MHz Estimated radio range: 30m (inside building) Operating temperature: —# —# 4 The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning EN This product complies with the following standards: EN 60730-1, EN 60950-1. 4.3 General description 5 EN The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning 1 ,, 2 6!# 32°C 32 10:55 #/- /54 !"'.$ #.#./ 3 6 7 4 1- Temperature gauge sensor 2- Command keypad 3- Display 4- Hole cover-plate 5- Power terminals 6- Terminals for connecting the WI08 7- Automation connection terminals (relays). 5 5 Installation Before installing, do the following: • Make sure that the sport where the device will be secured is protected from impacts. Secure the device using suitable screws, plugs, and so on for the type of surface; • Make sure you have a suitable omnipolar cut-off device with contacts more than 3 mm apart, and independent (sectioned off) power supply; • Make sure that any connections inside the case (that provide continuance to the protective circuit) be fitted with extra insulation as compared to the other conductive parts inside; • Make sure you have suitable tubing and conduits for the electrical cables to pass through and be protected against mechanical damage; 5.2 Tools and materials Make sure you have all the tools and materials you will need for the installation at hand to work in total safety and compliance with the current standards and regulations. The following figure illustrates the minimum equipment needed by the installer. 6 The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning EN 5 .1 Preliminary checks EN The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning 5.3 Dimensions, centre distances and securing holes 117 46.5 37 9.5 80 83.5 50 38 75.5 7 EN IN OUT Transponder RS 485 Radio Relay IN Keys Thermostat Timer Wave allows you to associate an “IN” command such as: Transponder, keys, thermostat and timer to an “OUT” instruction such as a radio code or a relay plug or to the connection of another device (only for the WI08). For example: you may control the garden lights with either the timer or keys and transponder. 8 The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning 5.4 Introduction to the functioning logic EN The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning 5.5 Connecting cables 230 V. a.c. power source ,, 6!# #/- /54 !"'.$ #.#./ Relay socket Serial connection sockets for WI08 card 9 1 3 10 The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning EN 5.6 Wall mounting 2 6 Programming 6.1 Description of commands and display 32 C 10:55 - Accessing the menu - Confirming and memorising the set value The ESC key 32°C 32 10:55 is for : - Exiting the menu - Cancelling changes 32 C 10:55 - Go back in the editable menus 32 C 10:55 The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning is for : EN The ENTER key Active local relay Set Thermostat Set Timer 32 C Set Alarm clock 10:55 The key are for: 32 C 10:55 - Shift from one menu item to another - Increase and decrease a value Status indicator (shows which menu you are browsing) Selected item MENU Setup Edit User New User Delete User } Menu items: can be selected using arrow keys 11 32°C 32 10:55 MENU Setup Edit User New User Delete User To enter the main menu, keep the ENTER key pressed MENU Setup Edit User New User MENU Delete User Setup Edit User New User Delete User To enter the submenu, press the ENTER key To chose the selected item, shift using the ARROWS New User ? New User CONFIRM (NO) ? CONFIRM (YES) To select, shift using the ARROWS New User ? CONFIRM (YES) 12 Press ENTER to confirm Pressing the Esc key takes you to the previous menu The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning EN 6.2 Browsing Menu 6.3 Structure - Main Menu EN The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning Pressing the Enter key for a few seconds takes you into the main menu (main level) Setup Edit User New User To shift from one item to another use the ARROWS Delete User TX Radio Timer Press Enter to confirm (this takes you to the second level) Alarm Thermostat Clock Key Function Pressing Esc takes you back to the previous menu Password 13 6.3.1 Menu – Settings – Language 32 C 10:55 32 C 10:55 Language ITALIAN Edit User Temperature ENGLISH New User Screen Saver FRENCH EN Setup GERMAN SPANISH Choose the selected language and confirm by pressing ENTER NEDERLANDS 14 The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning C 55 6.3.2 Menu – Settings – Temperature Select the unit of measure for32theC temperature and confirm by pressing ENTER 32 C 10:55 The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning Setup Language EN 32 C 10:55 10:55 32 C 10:55 Edit User Temperature Celsius New User Screen Saver Fahrenheit 6.3.3 Menu – Settings – Screensaver Select the screensaver and conform by pressing ENTER 32 C 10:55 Setup Language Edit User Temperature Logo CAME 32 C 10:55 New User Screen Saver Hour Date 15 6.4 Menu – Change user 32 C 0:55 Change user: Allows you to change the details of a single user (code, name, kind of exit) 32 C 10:55 SELECT USER 32 C 10:55 Edit User New001 New User New002 New00 New n.. In the single user change menu, you may choose the parameters to change using the arrows. Once you have chosen which to change confirm by pressing Enter Edit User 32 C 10:55 New001 CODE NAME OUTPUT 16 Select the use to change by using the arrows. Confirm by pressing ENTER The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning EN Setup 6.4 Change user - Menu 32 C 10:55 Edit User New001 EN NEW CODE You may memorise a transponder code and associate it to a chosen user, by approaching the card to the Wave device which enables code recognition within 10 s 32 C 10:55 32 C 10:55 Press ENTER NAME Selecting the NAME item takes you into the user change area. to : - To go to the next letter that needs changing - Confirm the changes (keeping it pressed) Press ESC Edit User new001 new n 001 to : - Go back to the previous letter - Go back to the previous level, without saving any 32 C changes 10:55 (keeping it pressed) 32 C 10:55 The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning CODE Keep the arrow keys pressed - Change letter 32 C to: 10:55 17 EXIT associates a command to a user. It can be of two types: the first is defined as local exit and is a physical socket (NO, NC); the second is a radio socket To select the output to (up to four different ones can be inserted). associate shift using the Edit User new001 arrow keys and confirm by 32 C 10:55 pressing Enter OUTPUT LOCAL RELAY OUTPUT 6.5 New user - Menu C 55 Edit User 32 C 10:55 New User Neu User ? CONFIRM (NO) Delete User 18 New user : to create a new user shift using the arrow keys to YES and confirm by pressing Enter. The change menu is activated automatically. To set the date see chapter 6.4. The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning EN 6.4 Change user - Menu 6.6 Eliminate User - Menu 32 C 10:55 Eliminate User: Eliminates a present user. EN The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning Setup Edit User New User 32 C 10:55 Delete User SELECT USER New001 32 C 10:55 TX Radio New002 New00 Delete User New002 ? CONFIRM (NO) New n.. To confirm the operation shift to YES using the arrow keys and confirm using Enter. 19 6.7 Radio TX - Menu Delete User TX Radio 32 C 10:55 TX Radio To select the radio channel to be memorised shift using the arrow and confirm by pressing Enter RADIO CHNL 1 Timer Send the radio code by transmitter within 10 seconds (as shown in figure). Memorisation is confirmed when code is shown on display. TX Radio RADIO CHNL:1 WAIT Use transmitters of the following series: Top 433.92MHz or Tam 433.92MHz 20 The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning EN C 55 From the RADIO TX menu you can associate a CAME transmitter code to an output, so as to “repeat” it and control the automated devices directly through the keyboard or transponder from WAVE. 6.8 Menu - Timer The TIMER lets you associate commands to pre-set time intervals. 32 C 10:55 The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning 32 C 10:55 Timer Timer EDIT NEW REMOVE To create a new time interval shift using the arrow key onto NEW and confirm by pressing Enter… Alarm …once created, you will be asked the time and minutes and the day of activation, and which command you wish to associate (local output, or one of the radio outputs)… Timer …then set the deactivation day. You will be asked the same information, to create a precise time interval. SWITCH ON TIME 08 Timer Besides creating a new “TIMER” you may also CHANGE or ELIMINATE those already existing. EDIT Timer NEW EW Once the timer is set, the display will show this symbol. DISATTIVAZIONE ORA 32 32°C 08 10:55 REMOVE 21 EN TX Radio 6.9 Alarm clock - Menu Timer 32 C 10:55 Alarm Alarm SELECT 1 Thermostat Once the alarm clock/s is/are set, this symbol will appear on the display. 22 Timer DISATTIVAZIONE ORA 32 32°C 08 10:55 Select which of the two alarm clocks you wish to set. You will be asked the time, minutes, and type of sound. Confirm by pressing Enter . The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning ALARM CLOCK allows you to set two sound warnings. EN C 55 The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning The Thermostat allows you to set a temperature interval, within which Wave will activate a socket.. Alarm 32 C 10:55 Thermostat Thermostat SWITCH o 20 C Clock To deactivate functioning shift using the ARROWS onto DEACTIVATED and press ENTER. Once the thermostat is set, this symbol will appear on the display. To create a new interval shift using the ARROW onto the chosen temperature threshold and confirm by pressing ENTER. Repeat the process to chose the deactivation threshold, confirm functioning by shifting using the ARROW onto ACTIVATED and press ENTER. Timer DISATTIVAZIONE ORA 32 32°C 08 10:55 23 EN 32 C 10:55 6.10 Thermostat - Menu 6.11 Clock – Menu C 55 You will be asked to enter the hour, minutes, seconds, year, month and day. To insert them proceed as in the previous steps (using the arrow keys to make changes to the values and by pressing Enter to confirm). EN Thermostat 32 C 10:55 Clock Clock HOUR 21 Key Function 6.12 Key Functions – Menu Key Functions allows you to associate, to the two one of the 4 radio codes. keys, one of the following functions: relay output or C 5 Clock 32 C 10:55 Key Function Password 24 Key Function KEY RELAY OUT To associate a command to one of the two key shift using the arrows onto the chose function, and confirm by keeping the arrow key pressed. The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning With the Clock you can set the current time and date on Wave. 6.13 Password - Menu The Password allows you to limit access to Wave’s functions 32 C 10:55 The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning Password 32 32 C 10:55 C 10:55 Password DISABLED The Activate or Deactivate function lets you make the Password operational. 32 C 10:55 32 C EDIT PASSWRD ENABLED 32 C 10:55 EDIT CODE ODE 1 10:55 CODE 1 Code means a 4-digit number, while transp. Uses a transponder card to access. EN Key Function 32 C 10:55 NEW PASSWRD See page 26 fig. A 32 C 10:55 CODE 2 DEL.PASSWRD 32 C 10:55 PSW TRASP 1 See page 27 See page 26 fig. B New password allows you to create a new code. Eliminate password allows to cancel an existing password. PSW TRASP 2 25 6.13 Password - Menu DEL. PASSWRD fig. A To confirm the step shift using the ARROW keys onto YES and confirm by pressing ENTER. ? CONFIRM (NO) 32 C 0:55 fig. B TYPE CODE 1 1234 5678 NEW 90<> PASSWRD 1000 1 To chose a value shift using the ARROW key, select and confirm by pressing ENTER. Repeat the step until you have inserted the 4-digit code that you have chosen. When the password is requested upon accessing the WAVE menu, proceed as TYPE CODE 1 1234 5678 90<> 1000 1 26 described above to insert the code. The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning EN 32 C 0:55 6.13 Password - Menu PSW TRASP 10:55 132 C 32 C 10:55 The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning EN NEW PASSWRD 32 C 10:55 DEL.PASSWRD DEL. PASSWRD ? CONFIRM (NO) PSW TRASP 1 32 C 10:55 NEW CODE To confirm the operation shift using the ARROWS to YES and confirm by pressing ENTER Selecting NEW PASSWORD will bring up a bar showing the time allowed for inserting the code. Approach the card to the Wave device to allow recognition of the code. When the main menu access password is requested approach the “Password” function card near WAVE. 27 Wave does not require any periodic maintenance. To clean we suggest using a moist cloth and not any chemical agents or abrasive materials that may ruin the product’s surface. For any problems contact after-sales assistance. 8 Phasing out and Disposal Our products are made of different materials. The majority of these (aluminium, plastic, iron, and electric cables) are considered solid urban waste. As such they can be recycled by certified centres after proper collection. Other component (such as electronic cards, batteries and transmitters) constitute environmental hazards. They must thus be turned in to specialised firms for their processing and disposal. 28 The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning EN 7 Maintenance 9 Manufacturer’s statement CE CONFORMITY DECLARATION EN The data and information shown in this manual may be changed by CAME cancelli automatici s.p.a. at any time without prior warning Pursuant to Low Voltage Directive 73/23/EC CAME Cancelli Automatici S.p.A. via Martiri della Libertà, 15 31030 Dosson di Casier - Treviso - ITALY tel (+39) 0422 4940 - fax (+39) 0422 4941 internet: www.came.it - e-mail: [email protected] Declares under its own responsibility that the equipments for automatic garage doors and gates listed below: --- STANDARDS --EN 60730-1/-2/-9 EN 60950-1 EN301489-1 IMPORTANT WARNING! Do not use the equipment specifi ed here above, before completing the full installation In full compliance with the Low Voltage Directive 73/263/EC WA01 … comply with the National Law related to the following European Directives and to the applicable parts of the following Standards. --- DIRECTIVES --73/23/CEE-93/68/CE 89/336/CEE - 92/31/CEE LOW VOLTAGE DIRECTIVE ELECTROMAGNETIC COMPATIBILITY DIRECTIVE MANAGING DIRECTOR Mr. Andrea Menuzzo Reference code to request a true copy of the original: DDF L EN W001 29 UNIT 3, ORCHARD BUSINESS PARK TOWN STREET, SANDIACRE NOTTINGHAM - NG10 5BP - U.K. Tel - 0044 115 9210430 Fax - 0044 115 9210431 Cod. 119RU27 v 0.1 01/07 © CAME cancelli automatici s.p.a. CAME UNITED KINGDOM LTD