Preview only show first 10 pages with watermark. For full document please download

We Can Do It! - Waarom Energie Onafhankelijk?

   EMBED


Share

Transcript

Reduce Your Electricity Bill To Zero? We can do it! 1 6 2 1 Generate solar 2 Use it directly 3 5 3 Store it for later use 4 Use stored energy 4 5 Feed surplus energy into the grid 6 Monitoring and control W W 1600 1600 1400 1400 1200 1200 1000 1000 800 800 600 600 400 400 200 200 0:00 PV production 12:00 Energy� consumption 24:00 Own� consumption Feed� in 0:00 12:00 PV production Energy� consumption 24:00 Own� consumption Feed� in www.energieonafhankelijk.nl Reduce Your Energy Bills To Zero? We can do it! * All data shall be changed without prior notice, SolaX Power reserves the right to explain and update the information contained here into. SAFE AND LAST LONGER! Lith iu m B attery 5 LIFE TIME 10 YEARS WARRANTY EASY TO EXPAND YEARS > 4000 LIFE CYCLES Basic Parameters Extra2000 Nominal Parameters Basic Parameters o Extra2000 o Voltage(V) 48 Capacity(Ah) 50 Capacity(Wh) 2400 10 years Structural Parameters 8 years Height(mm) 132(3U) Life Cycles (80% DOD, 25 C/77 F) >4000 Length(mm) 442 Maintenance Free in quality guarantee period Width(mm) 370 28±0.5 Life (25 C/77 F) o o Life (40 C/122 F) o o ≥ 5h Weight(Kg) Storage Time (25 C/77 F) 6 Months power off Electrical Parameters Operation Temperature -25 C~60 C(-13 F~140 F) Backup Duration (Average Power 500W) o o o o o o o o o o Operating Voltage(V) 42~54 Storage Temperature -40 C~80 C(-40 F~176 F) Charge Voltage(V) 53.5~56.5 Seismic Standard GR-1089 Maximum Discharge Current(A) 50 Transport Standard UN 3090 Maximum Charge Current(A) 10 IEC 61000, EN 55022 Communication Parameters EMC Standard Environmental Standard GB/T 2423 Network Interface RS232 The Authentication Level TUV,CE,CCC,TLC5 Communication Protocols YD/T 1363.3-2005 * All data shall be changed without prior notice, SolaX Power reserves the right to explain and update the information contained here into. SOLAX POWER ECONOMIZES YOUR DAILY LIFE! Lead -acid b attery Features and benefits Long life cycle service design: • Proven C&D DCS plate technology • Maximum cycle life for deep cycle & hybrid applications • High charge acceptance for rapid recharge True front access design: • True direct connect terminal for reliability • C&D Ohmic Ring for accurate testing • Standard true front access gas collection system for sealed cabinet installation • Connection versatility Maximum performance: • Superior output due to direct terminal connection • Low internal resistance Compliant to major global specifications: • British Standard BS 6290: Part 4:1997 • IEC 60896-21/22 • Telecordia SR-4228 • Eurobat Guide Classification: long life • Bellcore GR-63-CORE & GR-1089-Core • UL94 V-0FR • Non-hazardous, not restricted for any transportation mode (air, water or land) Specifications Operating Temperature Range with temperature compensation Discharge:-40°C (-40°F) to + 71°C (160°F) Charge:-23°C (-10°F) to + 60°C (140°F) Nominal Operating Temperature Range 20°C (+68°F) to + 35°C (95 °F) Recommended Maximum Charging Current Limit 0.2 C8 Float Charging Voltage 13.65 ± 0.15 VDC average per 12V unit Maximum AC Ripple (Charger) 0.5% RMS or 1.5% P-P of float charge voltage recommended for best results. Max voltage allowed = 1.4% RMS (4% P-P) Max current allowed = C/20 Self Discharge Battery can be stored up to 6 months at 25°C (77°F) before a freshening charge is required. Batteries stored at temperatures greater than 25°C (77°F) will require recharge sooner than batteries stored at lower temperatures. See C&D brochure 41-7272, SelfDischarge and Inventory Control for details. Equalize charge & cycle service voltage 14.40 to 14.80 VDC average per 12V unit @ 25°C (77°F) Terminal Threaded copper alloy insert terminal to accept: -M8 bolt (TEL12-105 FNSGC, TEL12-170 FGC, TEL12-210 FGC) -M6 bolt (TEL12-115 FNGC) Terminal Hardware Initial Torque 18 N-m (160 in.-lbs) for: TEL12-105 FNSGC, TEL12-170 FGC, TEL12-210 FGC 12 N-m (107 in.-lbs) for: TEL12-115 FNGC * All data shall be changed without prior notice, SolaX Power reserves the right to explain and update the information contained here into. Double Insurance, Max. Load is up to 1000 K G! 1000 KG Max. Load Material of the cabinet is cold rolled plate Material for wheels are rubber with stainless stabilizer Lithium Battery Cabinet MODEL Note: SIZE L×W×H(mm) NO. OF WHEELS NO. OF HOLDERS MAX. LOAD (KG) HL/AS-6622 (22U) 600x600x1050 4 4 1000 HL/AS-6630 (30U) 600x600x1600 4 4 1000 HL/AS-6635 (35U) 600x600x1800 4 4 1000 HL/AS-6642 (42U) 600x600x2000 4 4 1000 1. U is the standard unit of measure for designating the vertical usable space, or height of racks (metal frame designed to hold hardware devices) and cabinets (enclosures with one or more doors). This unit of measurement refers to the space between shelves on a rack. 1U is equal to 1.75 inches. For example, a rack designated as 20U, has 20 rack spaces for equipment and has 35 (20 x 1.75.) inches of vertical usable space. Rack and cabinet spaces and the equipment which fit into them are all measured in U. 2. Size of battery cabinet depends on the No. of Li batteries. 1 Li battery is 3U, so 22U supports up to 22/3≈7 Li batteries, and so on Reasonable Design, 5 minutes to install! 600 Lead-acid Battery Cabinet KG Max. Load SIZE L×W×H(mm) WEIGHT (KG) NO. OF WHEELS NO. OF HOLDERS MAX. LOAD (KG) 780x630x380 40 0 4 600 Note: 1. Material is cold rolled plate. 2. 1 cabinet is designed for 1 group of Lead-acid batteries. Technea Duurzaam Pallasweg 13 8938 AS Leeuwarden 058 - 288 79 14 [email protected] www.energieonafhankelijk.nl