Transcript
Reduce Your Electricity Bill To Zero?
We can do it!
1 6 2
1 Generate solar 2 Use it directly
3
5
3 Store it for later use 4 Use stored energy
4
5 Feed surplus energy into the grid 6 Monitoring and control
W
W
1600
1600
1400
1400
1200
1200
1000
1000
800
800
600
600
400
400
200
200 0:00
PV production
12:00 Energy� consumption
24:00 Own� consumption
Feed� in
0:00
12:00
PV production
Energy� consumption
24:00 Own� consumption
Feed� in
www.energieonafhankelijk.nl
Reduce Your Energy Bills To Zero?
We can do it!
* All data shall be changed without prior notice, SolaX Power reserves the right to explain and update the information contained here into.
SAFE AND LAST LONGER! Lith iu m B attery
5
LIFE TIME
10
YEARS
WARRANTY
EASY TO EXPAND
YEARS
> 4000 LIFE CYCLES
Basic Parameters
Extra2000
Nominal Parameters
Basic Parameters o
Extra2000
o
Voltage(V)
48
Capacity(Ah)
50
Capacity(Wh)
2400
10 years
Structural Parameters
8 years
Height(mm)
132(3U)
Life Cycles (80% DOD, 25 C/77 F)
>4000
Length(mm)
442
Maintenance
Free in quality guarantee period
Width(mm)
370 28±0.5
Life (25 C/77 F) o
o
Life (40 C/122 F) o
o
≥ 5h
Weight(Kg)
Storage Time (25 C/77 F)
6 Months power off
Electrical Parameters
Operation Temperature
-25 C~60 C(-13 F~140 F)
Backup Duration (Average Power 500W) o
o
o
o
o
o
o
o
o
o
Operating Voltage(V)
42~54
Storage Temperature
-40 C~80 C(-40 F~176 F)
Charge Voltage(V)
53.5~56.5
Seismic Standard
GR-1089
Maximum Discharge Current(A)
50
Transport Standard
UN 3090
Maximum Charge Current(A)
10
IEC 61000, EN 55022
Communication Parameters
EMC Standard Environmental Standard
GB/T 2423
Network Interface
RS232
The Authentication Level
TUV,CE,CCC,TLC5
Communication Protocols
YD/T 1363.3-2005
* All data shall be changed without prior notice, SolaX Power reserves the right to explain and update the information contained here into.
SOLAX POWER ECONOMIZES YOUR DAILY LIFE! Lead -acid b attery Features and benefits Long life cycle service design: • Proven C&D DCS plate technology • Maximum cycle life for deep cycle & hybrid applications • High charge acceptance for rapid recharge True front access design: • True direct connect terminal for reliability • C&D Ohmic Ring for accurate testing • Standard true front access gas collection system for sealed cabinet installation • Connection versatility Maximum performance: • Superior output due to direct terminal connection • Low internal resistance Compliant to major global specifications: • British Standard BS 6290: Part 4:1997 • IEC 60896-21/22 • Telecordia SR-4228 • Eurobat Guide Classification: long life • Bellcore GR-63-CORE & GR-1089-Core • UL94 V-0FR • Non-hazardous, not restricted for any transportation mode (air, water or land)
Specifications Operating Temperature Range with temperature compensation
Discharge:-40°C (-40°F) to + 71°C (160°F) Charge:-23°C (-10°F) to + 60°C (140°F)
Nominal Operating Temperature Range
20°C (+68°F) to + 35°C (95 °F)
Recommended Maximum Charging Current Limit
0.2 C8
Float Charging Voltage
13.65 ± 0.15 VDC average per 12V unit
Maximum AC Ripple (Charger)
0.5% RMS or 1.5% P-P of float charge voltage recommended for best results. Max voltage allowed = 1.4% RMS (4% P-P) Max current allowed = C/20
Self Discharge
Battery can be stored up to 6 months at 25°C (77°F) before a freshening charge is required. Batteries stored at temperatures greater than 25°C (77°F) will require recharge sooner than batteries stored at lower temperatures. See C&D brochure 41-7272, SelfDischarge and Inventory Control for details.
Equalize charge & cycle service voltage
14.40 to 14.80 VDC average per 12V unit @ 25°C (77°F)
Terminal
Threaded copper alloy insert terminal to accept: -M8 bolt (TEL12-105 FNSGC, TEL12-170 FGC, TEL12-210 FGC) -M6 bolt (TEL12-115 FNGC)
Terminal Hardware Initial Torque
18 N-m (160 in.-lbs) for: TEL12-105 FNSGC, TEL12-170 FGC, TEL12-210 FGC 12 N-m (107 in.-lbs) for: TEL12-115 FNGC
* All data shall be changed without prior notice, SolaX Power reserves the right to explain and update the information contained here into.
Double Insurance,
Max. Load is up to 1000 K G! 1000 KG
Max. Load
Material of the cabinet is cold rolled plate
Material for wheels are rubber with stainless stabilizer
Lithium Battery Cabinet MODEL
Note:
SIZE L×W×H(mm)
NO. OF WHEELS
NO. OF HOLDERS
MAX. LOAD (KG)
HL/AS-6622 (22U)
600x600x1050
4
4
1000
HL/AS-6630 (30U)
600x600x1600
4
4
1000
HL/AS-6635 (35U)
600x600x1800
4
4
1000
HL/AS-6642 (42U)
600x600x2000
4
4
1000
1. U is the standard unit of measure for designating the vertical usable space, or height of racks (metal frame designed to hold hardware devices) and cabinets (enclosures with one or more doors). This unit of measurement refers to the space between shelves on a rack. 1U is equal to 1.75 inches. For example, a rack designated as 20U, has 20 rack spaces for equipment and has 35 (20 x 1.75.) inches of vertical usable space. Rack and cabinet spaces and the equipment which fit into them are all measured in U. 2. Size of battery cabinet depends on the No. of Li batteries. 1 Li battery is 3U, so 22U supports up to 22/3≈7 Li batteries, and so on
Reasonable Design,
5 minutes to install!
600
Lead-acid Battery Cabinet
KG
Max. Load
SIZE L×W×H(mm)
WEIGHT (KG)
NO. OF WHEELS
NO. OF HOLDERS
MAX. LOAD (KG)
780x630x380
40
0
4
600
Note: 1. Material is cold rolled plate. 2. 1 cabinet is designed for 1 group of Lead-acid batteries.
Technea Duurzaam Pallasweg 13 8938 AS Leeuwarden 058 - 288 79 14
[email protected] www.energieonafhankelijk.nl