AA-05-PIR Audio Alert Instruction Manual Contents Introduction ...................................................................................................................4 Recording a Message ...................................................................................................5 Wiring ............................................................................................................................9 Adjusting Volume ........................................................................................................ 10 Installation ................................................................................................................... 11 Using the AA-05-PIR ................................................................................................... 16 Specifications .............................................................................................................. 17 Contact Details ............................................................................................................ 17
01572-53-000
Page 2 of 17
Issue 1 22nd May 2014
AA-05-PIR Audio Alert Instruction Manual
CE Declaration of Conformity Manufacturer:
Lasermet Ltd. Lasermet House, 137 Hankinson Road, Bournemouth BH9 1HR U.K.
Equipment:
AA-05-PIR Audio Alert 01303-00-000 Standard
Applicable Directives:
Low Voltage Directive 73/23/EEC CE Directive 93/68/EEC EMC Directive 2004/108/EC
European Standards to which conformity is declared: EN 60598-1: 2008 EN 62471:2008 EN 55015:2006 EN 61547:1995 inc. A1:2000 EN 61547:2009
I hereby declare that the above listed products conform to the relevant sections of 73/23/EEC, 93/68/EEC and 2004/108/EC.
Signed:
Name:
A. Tyerman
Position:
Quality Assurance Manager
Date:
22th May 2014
01572-53-000
Page 3 of 17
Issue 1 22nd May 2014
AA-05-PIR Audio Alert Instruction Manual
Introduction The AA-05-PIR Audio Alert device is intended to be used in conjunction with Lasermet’s Laser Interlock systems for the purpose of audibly warning personnel of hazards by playing back a message recorded on the device. However, the devices can be readily used independently from Lasermet Interlock systems. The AA-05-PIR plays back a recorded message up to 40 seconds long (13 seconds default) when it detects motion (e.g. a person walking past) with its integrated PIR sensor. The AA-05-PIR can hold up to two different messages, which are selectable using a keyswitch on the side of the unit. The integrated PIR sensor has detection range of 5m from the device and a detection angle of approximately 45 degrees around the central point of the detector. The messages are generally recorded at factory and can be any audio whether it be speech, music or other. The repetition rate and the number of repetitions of the message are factory settable to end-user requirements. The AA-05-PIR incorporates adjustable volume control and line-out features to allow audio output to external devices such as amplifiers, speakers and PA systems. Lasermet provides a full range of laser interlock equipment including control systems, interlock switches, illuminated warning signs, laser shutters, door locks, external power supplies etc. which can be connected to provide a complete laser interlock system. Full support, design and installation is available from Lasermet, please contact us for any queries. Contact details are given at the end of this manual.
01572-53-000
Page 4 of 17
Issue 1 22nd May 2014
AA-05-PIR Audio Alert Instruction Manual
Recording a Message Generally, the customer can provide Lasermet with digital audio files when ordering an AA-05-PIR and Lasermet will upload the files onto the device for the customer prior to delivery. Lasermet also has an in-house vocalist who can record written messages onto the AA-05-PIR prior to delivery. If the customer wishes to record their own messages, then optional Lasermet part AA-MIC can be purchased. AA-MIC is special microphone with custom connections specifically for the Audio Alert range. The following steps indicate how recording with the AA-MIC is performed. Step 1 – Remove Side of Case
Figure 1: Removing Highlighted Screws Remove the four screws circled in red, and remove the side of the case exposing the circuit board and connections inside.
01572-53-000
Page 5 of 17
Issue 1 22nd May 2014
AA-05-PIR Audio Alert Instruction Manual
Step 2 – Connect Power
Figure 2: Connecting Power Cable Connect the power cable to the power input connector on the outside of the device (Refer to “Wiring” section if in doubt)
01572-53-000
Page 6 of 17
Issue 1 22nd May 2014
AA-05-PIR Audio Alert Instruction Manual
Step 3 – Connect AA-MIC Microphone
Figure 3: Connecting the AA-MIC Connect the AA-MIC to connector J3 (Record 1) on the circuit board, making sure that Pin 1 on the AA-MIC is aligned with pin one on J3. Ensure power supplied on to the AA-05-PIR, and the power keyswitch is in the “On” position.
01572-53-000
Page 7 of 17
Issue 1 22nd May 2014
AA-05-PIR Audio Alert Instruction Manual
Step 4 – Record the Message
Figure 4: Recording the Message using AA-MIC Slide the switch on the AA-MIC to on and record your message, speaking clearly into the microphone. Immediately after you finish speaking, slide the switch on the AA-MIC back to the off position. Switch off power to the AA-05-PIR, and ensure the message select keyswitch is in the “1” position. When power is reapplied to the AA-05-PIR and motion is detected, your recorded message should be heard. Repeat this process until you are satisfied with the message. To record the second message on the AA-05-PIR, attach the AA-MIC to J12 (Record 2) connector on the circuit board, set the message select keyswitch to the “1” position and repeat the above steps. When satisfied, remove power and AA-MIC from the AA-04-PIR and screw the side of the case back on.
01572-53-000
Page 8 of 17
Issue 1 22nd May 2014
AA-05-PIR Audio Alert Instruction Manual
Wiring
Figure 5: Power Cable Connection
The AA-05-PIR is supplied with an open-ended lead which connects to the power input on the AA-05-PIR. The open ended leads has two cores, the red should be connected to the positive of the power supply and the blue to the negative. +6 to +24VDC should be applied in order to power the unit and when motion is detected the speech routine will start. If the audio signal is required to be outputted to an external amplifier or other audio device, the power input connector has an extra contact to facilitate this. If you are interested in this feature please contact Lasermet, as an additional lead will need to be purchased.
01572-53-000
Page 9 of 17
Issue 1 22nd May 2014
AA-05-PIR Audio Alert Instruction Manual
Adjusting Volume
Figure 6: Volume Adjuster In order to adjust the volume of the playback, a small screwdriver should be used to turn the volume adjuster (pictured above) clockwise to increase volume or counterclockwise to decrease the volume. The side of the case will need to be removed in order to carry this out – instructions to do this can be found in the “Recording a message section”. The volume adjuster is placed within the unit to prevent unauthorised changes to the volume of the device.
01572-53-000
Page 10 of 17
Issue 1 22nd May 2014
AA-05-PIR Audio Alert Instruction Manual
Installation The AA-05-PIR is supplied with a tilting bracket, which is permanently attached to a wall or other fixed vertical surface. The AA-05-PIR itself then attaches to this bracket by means of a padlock. This permits simple and easy removal of the device, whilst still preventing unauthorised removal. Positioning The AA-05-PIR should be mounted in a convenient position for use and wiring. During installation, cable connections will need to be made and allowance should be made for the installation of electrical conduit or trunking if required to gain access to the unit’s location. It is recommended that there must be a flat unobstructed area of wall extending at least 200mm above and 200mm below the mounting centre to allow fitment and removal.
01572-53-000
Page 11 of 17
Issue 1 22nd May 2014
AA-05-PIR Audio Alert Instruction Manual
Mounting the Tilting Bracket
Figure 7: Mounting Rear Half of Bracket Identify the rear half of the bracket, which has no Velcro dots. Using suitable screws for the wall or vertical surface you are mounting the bracket to, screw through whichever of the 8 small holes on the rear of the bracket are most convenient to the installation. Lasermet recommends using the holes as shown in Figure 7. The rear half of the bracket should be level, and in a suitable position for utilising the AA-05-PIR.
01572-53-000
Page 12 of 17
Issue 1 22nd May 2014
AA-05-PIR Audio Alert Instruction Manual
Figure 8: Mounting Front Half of Bracket Identify the front half of the bracket which has two black Velcro dots. Using the supplied security bit and screwdriver in the AA-05-PIR wall mounting kit, mount the front half of the bracket to the rear half of the bracket using the security screws. The small holes on the sides of the bracket can be used to locate the front half of the bracket at an angle. This allows the AA-05-PIR to be pointed at the location to be monitored by the PIR sensor.
01572-53-000
Page 13 of 17
Issue 1 22nd May 2014
AA-05-PIR Audio Alert Instruction Manual
Mounting the AA-05-PIR
Figure 9: Mounting AA-05-PIR Pass the lugs on the rear of the AA-05-PIR through the two holes on the front of the bracket. You will notice that the Velcro dots on the AA-05-PIR meet with the Velcro dots on the bracket. Using the supplied padlock in the AA-05-PIR wall mounting kit, pass the shackle through the two holes in the lugs and secure the padlock underneath the AA-05-PIR.
01572-53-000
Page 14 of 17
Issue 1 22nd May 2014
AA-05-PIR Audio Alert Instruction Manual
Figure 10: Mounted AA-05-PIR The AA-05-PIR is now held securely in place.
01572-53-000
Page 15 of 17
Issue 1 22nd May 2014
AA-05-PIR Audio Alert Instruction Manual
Using the AA-05-PIR Once the AA-05-PIR is mounted on the wall and the power supply cabling is attached, the power supply can be turned on. It is suitable for the AA-05-PIR power cable to be attached while the power supply is on. Once the power keyswitch on the side of the unit is turned to the “On” position, the AA-05-PIR will monitor its integral PIR sensor for a signal of a person walking past the device. Once the person is detected, the pre-installed message will play. The device will then instate a delay set to user requirements at factory before being able to be triggered again by another person walking past the device. The message select keyswitch will select between the first and second pre-installed message, positions “1” and “2” respectively. This can be switched between at any time, and the device doesn’t need turning off to do this.
01572-53-000
Page 16 of 17
Issue 1 22nd May 2014
AA-05-PIR Audio Alert Instruction Manual
Specifications Dimensions: 150 mm wide X 108mm high X 65 mm deep. Weight: 510g. Operating Voltage: +6 to +24VDC. Power Consumption: 0.48W standby, 3.8W activated.
All figures quoted are approximate. Lasermet reserve the right to alter specifications without prior notice.
Contact Details For sales and technical support:
Lasermet Ltd. Lasermet House, 137 Hankinson Road, Bournemouth BH9 1HR United Kingdom.
01572-53-000
Tel.: Fax:
+44 (0) 1202 770740 +44 (0) 1202 770730
E-mail: Website:
[email protected] www.lasermet.com
Page 17 of 17
Issue 1 22nd May 2014