Preview only show first 10 pages with watermark. For full document please download

Weschler Instruments

   EMBED


Share

Transcript

WESCHLER INSTRUMENTS Fuji Strip Chart Recorders ORDERING INFORMATION • Inkjet printing technology without physical contact with the paper • Low-cost • Lightweight, durable, and trouble-free 100mm recorder To Order–Insert Number Code for Each Letter to Select Catalog Number. Order Example: PHE1-X-Y-32-5Y-OEV • Available in one- or two-channel continuous trace A - B - C - D - E - F • Continuous analog trending on the same axis A • Prints periodic data, scale line, alarm condition, burnout, and parameter data • Manufactured in an ISO 9001 Facility • Three-year warranty B PHE ▲ C SPECIFICATIONS Input Points: Input Signals: Max. Allowable Input Voltage: Recording Method: Recording Points: Chart Paper: Recording Cycle: Recording Accuracy: Chart Speed: Power Supply: Dimensions (WxHxD): 1 or 2 continuous recording TC: B, R, S, K, E, J, T, N, W, L, U, PN RTD: Pt 100Ω DC Voltage: 50mV, 500mV, 5V, 50V range DC Current: 4 to 20mA, converted into voltage with 10Ω or 250Ω shunt resistor TC, RTD and DC Voltage: ±10V DC or less (50mV, 500mV range) DC Voltage Input: ±100V DC or less (5V, 50V range) Inkjet type, 3 colors 1 or 2 continuous Effective width: 100mm, Z-folding type, length–15.08m 2 sec. minimum (chart speed dependent) Indicating accuracy ±0.2% 10, 20, 24, 30, 50, 120, 200, 300, 400, 1000, 1200, 1500mm/hour, set from the keyboard 100 to 120 VAC or 200 to 240 VAC, 50/60Hz 5.67 x 5.67 x 6.89in. (144 x 144 x 175mm) D E F Recording Points PHE1 1 continuous recording point PHE2 2 continuous recording points Input Signal for Ch. 1 X B Thermocouple R R Thermocouple S S Thermocouple K K Thermocouple E E Thermocouple J J Thermocouple T T Thermocouple N N Thermocouple W W Thermocouple L L Thermocouple U U Thermocouple P PN Thermocouple H Pt100Ω RTD A DC 1-5V B DC 4-20mA with shunt resistor C DC 10-50mA with shunt resistor M DC ±50mV Q DC ±500mV V DC ±5V F DC ±50V Input Signal for Ch. 2 Y None X B Thermocouple R R Thermocouple S S Thermocouple K K Thermocouple E E Thermocouple J J Thermocouple T T Thermocouple N N Thermocouple W W Thermocouple L L Thermocouple U U Thermocouple P PN Thermocouple H Pt100Ω RTD A DC 1-5V B DC 4-20mA with shunt resistor C DC 10-50mA with shunt resistor M DC ±50mV Q DC ±500mV V DC ±5V F DC ±50V Power Supply 32 100V/120V AC, 50/60Hz 42 200V/240V AC, 50/60Hz Scale Range 5Y One channel 55 Two channels Alarm Output 0EV None 1EV 1-ch. recorder, 2-point/no external control AEV 1-ch. recorder, 2-point/with external control 2EV 2-ch. recorder, 4-point/no external control BEV 2-ch. recorder, 4-point/with external control 118 WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected] WESCHLER INSTRUMENTS Amprobe Portable Strip Chart Recorders Single Channel ▲ • Single-Phase AC Volts or Amps • Expandable Voltage Scale for Improved Resolution (Scale Does Not Start at Zero) PAV-3 SPECIFICATIONS Features AC Voltage – single phase 60Hz AC Current – single phase 60Hz Measurement Rate Chart paper speed Rolls paper back after recording Chart paper (30 foot) PAV3X-T 95-130 / 190-260 V N/A 60s, 5s, 2.5s 1”, 12” or 24” per hour yes 835X3A Chart paper (60 foot) 835X3A-6 PAVA783-12 PAVA83-T 95-130 / 190-260 / 380-520 V 0-10 / 50 / 250 / 500 A 5 sec 60s, 5s, 2.5s 12” per hour 1”, 12” or 24" per hour N/A Yes 835X3A-6 for Volts 850A for Ampers N/A 835X3A-6 for Volts 850A-6 for Amps Supplied with 120V Power Cord, Clamp-on Current Transducer and/or Voltage Input Leads OPTIONAL ACCESSORIES (for LAV and PAV models) Part Number AB/A47L AB/CT50-1 AB/CT50-2 AB/A50-1 Line splitter (Energizer) 5000A Clamp-on Current Transformer (50 to 1) 3000A Clamp-on Current Transformer (50 to 1) 600A Clamp-on Current Transformer (10 to 1) ORDERING INFORMATION AB/PAV3X-T AB/PAVA83-12 AB/PAVA83-T Single Channel ACV Recorder Single Channel ACV or ACA, 12”/HR Single Channel ACV or ACA, w take up Multi-Channel • Single Phase or Three Phase • 3 Recording Speeds (12"/hr, 6"/hr, 1"/hr) • Rerolls Paper After Recording (-T Models) LAV-21 Features LAV21 RMS and LAV21 RMS –T Number of phases recorded Single phase voltage simultaneously and current AC Voltage 0-150 / 300 / 600 V AC Current 0-15 / 60 / 150 / 300 A Chart paper, 30 foot roll 300SVA Chart paper, 60 foot roll 300SVA-6 (“-T” models only) (for LAV21 RMS-T only) Rolls paper back after recording LAV21 RMS-T only LAV3 RMS and LAV3 RMS –T Three phase voltage (can record single phase) 0-150 / 300 / 600 V N/A 830AV600 830AV600-6 (for LAV3 RMS-T only) LAV3 RMS-T only LAA3 RMS and LAA3 RMS –T Three phase current (can record single phase) N/A 0-15 / 60 / 150 / 300 A 300SVA 300SVA-6 (for LAA3 RMS-T only) LAA3 RMS-T only ▲ SPECIFICATIONS Supplied with 120V Power Cord, 300A Clamp-on Current Transducers and/or Voltage Leads ORDERING INFORMATION AB/LAV21RMS AB/LAV21RMS-T AB/LAV3RMS AB/LAV3RMS-T AB/LAA3RMS AB/LAA3RMS-T Recorder, single phase ACV & ACA Recorder, single phase ACV & ACA, w/ take up Recorder, 1Ø or 3Ø, ACV Recorder, 1Ø or 3Ø, ACV, w/ take up Recorder 1Ø or 3Ø, ACA Recorder 1Ø or 3Ø, ACA, w/ take up 119 WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected] WESCHLER INSTRUMENTS Hioki Strip Chart Recorders Partlow Chart Recorder • 1 or 2 Trend Pen Versions (optional) • Up to 2 Process or Limit Alarms for Each Pen • Simple Operation and Set-Up ▲ • Universal Inputs and Power Supply 8206-10 8205-10 SPECIFICATIONS Input: DC /AC Voltage: AC Current: Sampling period: Bandwidth: Paper Speed: Accuracy: Power: Dimensions: Supplied Accessories: Voltage or current, 1 channel 0.1-500V f.s., 12 ranges 10-1000A f.s., 7 ranges (with optional clamp) 10ms 20Hz - 30kHz, ±3dB 20cm/minute to 2cm/hour, 5 ranges Voltage: ±2% f.s. Current: ±4% f.s. (using 9651 clamp) 100-240VAC (50/60Hz) or 9.5-14VDC 9.9"W x 4.8"H x 3.9"D 1 roll recording paper, carrying case, input leads 8206-10 SPECIFICATIONS Input: AC Voltage: AC Current: Sampling period: Bandwidth: Paper Speed: Accuracy: Power: Dimensions: Supplied Accessories: Voltage and current, 2 channels alternate recording 100/200/500V extended scale, 3 ranges 10-1000A f.s., 7 ranges (with optional clamp) 10ms 30Hz to 30kHz, ±3dB 60cm/hour to 2cm/hour, 5 ranges Voltage: ±2% f.s. Current: ±4% f.s. (using 9651 clamp) 100-240VAC (50/60Hz) or 9.5-14VDC 9.9"W x 4.8"H x 3.9"D 1 roll recording paper, carrying case, input leads ORDERING INFORMATION HK/8205-10 HK/8206-10 HK/9650 HK/9651 HK/9668 HK/9235 HK/9236-01 One Channel Micro HiCorder Two Channel Micro HiCorder Clamp-on Sensor, 100A f.s., 40Hz-1kHz, 3m length Clamp-on Sensor, 500A f.s., 40Hz-1kHz, 3m length Clamp-on Sensor, 1000A f.s., 40Hz-1kHz, 3m length Recording paper (15m, 10 rolls) Recording paper, Climate-resistant (15m, 10 rolls) • Optional PC Configuration Port • RS-485 Communications Option • Two Year Warranty ▲ • AC or DC voltage to 500V • AC current to 1000A • 1 or 2 channels • 5 paper speeds • View input level on analog LCD display • NEMA 3 Standard (NEMA 4X Option) MRC5000 SPECIFICATIONS Input Range: TC: J, K, T, R, S RTD: 100Ω Platinum, 0.00385 Ω/Ω/°C Current DC: 0 to 20mA, 4 to 20mA Voltage DC: 0 to 25mV, 0 to 50mV, 10 to 50mV, 0 to 5V, 1 to 5V 10” User-configured: 8 hr, 12 hr, 24 hr, 48 hr, 7 day 0.5% of chart span reference accuracy 90 –264VAC 50/60Hz. 18VA max. consumption 14” x 14” x 3.8” (355.6 x 355.6 x 96.5mm) Chart Size: Chart Rotation: Recording Accuracy: Power Requirements: Dimensions (WxHxD): ORDERING INFORMATION To Order–Insert Number Code for Each Letter to Select Catalog Number. Order Example: PA/51 110211 A B C D E F G A Pen 1 PA/51 Recorder only PA/52 Recording Controller B Pen 2 0 None 1 Recorder only C Pen 1 Outputs 0 None 1 One Relay D Pen 2 Outputs 0 None 1 One Relay E Digital Communications 0 None 1 Configurator Port F Case 1 Standard-NEMA3 2 Door Lock G Voltage 1 Standard (90–264V AC) 3 Standard, with 24V DC Transmitter Power Supply H Option Suffix Blank None H PA/54 High/Low Limit 2 4 Recording Controller High/Low Limit 2 Two Relays 2 Two Relays 2 3 RS-485 Com (Modbus RTU) Configurator Port & RS-485 Com 3 NEMA 4X 5 7 Standard, with CE Approval Standard, with CE and Transmitter Power Supply AA Alarms and communications connectivity option One hundred 0-100°F, 24-hour charts are provided with each instrument. 120 WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]