Preview only show first 10 pages with watermark. For full document please download

Westwind Center, Spruce Grove, Alberta

   EMBED


Share

Transcript

Item 1 Alberta Building Code Matrix Parts 3 & 9 Project Description: Building N OBC Reference New Part 11 Part 3 Addition WESTWIND CENTER, SPRUCE GROVE, ALBERTA ARCHITECTURAL DRAWINGS Major Occupancy(s) 3 Major Occupancy(s) 4 Building Area (sq. M) 3.1.2.1.(1) Group E Existing Existing 5 Gross Area (sq. M) 6 Number of Storeys 7 Height of Building (m) 8 Number of Streets/Access Routes 9 Building Classification 10 11 Building Classification Sprinkler System Proposed New 925 - Total 925 New 925 - Above grade 1 3.1.2.1.(1) -- 1.1.3.2 -- 1.1.3.2 Total 925 Below grade 3.2.1.1 & 1.1.3.2 0 5.18 m (T/O STEEL) -- 1 Group E, up to 2 storeys 3.2.2.10 & 3.2.5 COVER PAGE SITE PLAN CONSTRUCTION ASSEMBLIES & NOTES FLOOR PLAN ROOF PLAN ELEVATIONS EXTERIOR WALL SECTIONS EXTERIOR WALL SECTIONS WALL SECTION TYPICAL DETAILS TYPICAL DETAILS TYPICAL DETAILS DOOR SCHEDULE GLAZING SCHEDULE CIVIL DRAWINGS C-1 C-2 C-3 C-4 C-5 GRADING PLAN UNDERGROUND UTILITIES PLAN GENERAL NOTES & STANDARD DETAILS STANDARD DETAILS STANDARD DETAILS LANDSCAPE DRAWINGS L-1 L-2 L-3 L-4 L-5 LANDSCAPE PLAN SITE CONCRETE LAYOUT PLAN DETAILS DETAILS SITE FURNITURE & DETAILS S1.0 S1.1 S1.2 S1.3 S1.4 S2.1 S3.1 S4.1 S4.2 S4.3 S5.1 S6.1 S6.2 S6.3 S7.1 S7.2 S7.3 S7.4 STRUCTURAL 3D VIEW GENERAL NOTES GENERAL NOTES AND TYPICAL DETAILS TYPICAL DETAILS AND SCHEDULES STRUCTURAL SPECIFICATIONS PILE LAYOUT PLAN FOUNDATION PLAN EYEBOWN/ CANOPY AND ROOF FRAMING PLAN HIGH PARAPET FRAMING PLAN SNOW PILING, WIND UPLIFT, WATER PONDING PLANS STEEL ELEVATION CONCRETE PIER DETAILS CONCRETE PIER DETAILS FOUNDATION SECTIONS FRAMING SECTIONS FRAMING SECTIONS FRAMING SECTIONS FRAMING SECTIONS MECHANICAL DRAWINGS M1 HVAC LAYOUT M2 PLUMBING & DRAINAGE LAYOUT M3 NOTES & SCHEDULES M4 DETAILS ELECTRICAL DRAWINGS ES1 ES2 E-1 E-2 E-3 E-4 ELECTRICAL SPECIFICATION ELECTRICAL SITE PLAN ELECTRICAL SPECIFICATIONS LEGEND & ELECTRICAL DETAILS ELECTRICAL FLOOR PLAN SINGLE LINE RISER DIAGRAM & PANEL SCHEDULES T URNER FLEISCHER ARCHITECTS INC.  Lesmill Road Toronto  Canada   Telephone() - turnerfleischer.com --2.1.1.3 -- 3.2.2.61 Entire Building STRUCTURAL DRAWINGS -- 3.2.2.61 --- -- Basement only In lieu of roof rating A0.0 A0.1 A1.0 A2.1 A2.2 A4.1 A5.1 A5.2 A5.3 A7.1 A7.2 A7.3 A8.1 A8.2 TURN ER FLEISC HER Alteration Change of Use 2 Part 9 2.1.1 9.10.1.3 This drawing, as an instrument of service, is provided by and is the property of Turner Fleisher Architects Inc. The contractor must verify and accept responsibility for all dimensions and conditions on site and must notify Turner Fleischer Architects Inc. of any variations from the supplied information. This drawing is not to be scaled. The architect is not responsible for the accuracy of survey, structural, mechanical, electrical, etc., information shown on this drawing. Refer to the appropriate consultant's drawings before proceeding with the work. Construction must conform to all applicable codes and requirements of authorities having jurisdiction. The contractor working from drawings not specifically marked 'For Construction' must assume full responsibility and bear costs for any corrections or damages resulting from his work. Not required Yes No 3.2.9. Grnd. Floor Yes No 3.2.4. 14 Water Service/Supply is Adequate Yes No 3.2.5.7. -- 15 High Building Yes No 3.2.6. -- 3.2.2.59 3.2.2.25 -- 3.2.1.1.(3)-(8) -- 3.1.17 -- 12 Standpipe required 13 Fire Alarm Required -- 16 Permitted Construction Actual Construction 17 18 Mezzanine(s) Area (sq. M) Non-combustible Non-combustible Occupancy: Occupancy: Occupancy: 19 Barrier-free Design 20 Hazardous Substances E E E Design of Building Load <-Persons Load <-Persons Load <-Load <-- Persons Persons Load <-Load <-Load <-- Persons Persons Persons No (Explain) Yes Yes Horizontal Assemblies FRR (Hours) Required Fire Resistance Rating (FRR) Floors Roof Mezzanine Mezzanine No Listed Design No. or Description (SB-2) 0 Hours 0 Hours - N/A Hours - FRR of Supporting Members Floors Roof Both Both N/A Occupant load based on S.M./Person Occupancy: Unit BN-1 E Occupancy: Unit BN-2 E Occupancy: Unit BN-3 E Occupancy: Unit BN-4 E Unit BN-5 Unit BN-6 Unit BN-7 21 Combustible Combustible -- 3.8 3.3.1.2 & 3.3.1.19 -- 3.2.2.61 & 3.2.1.4 -- Listed Design No. or Description (SB-2) 0 0 Hours Hours N/A Hours - 22 Spatial Separation - Consruction of Exterior Walls 3.2.3 Listed Design Comb. Constr. NonPermitted Proposed % Area of Comb. FRR L.D. L/H or or Nonc. Cladding Comb. Max % of of Openings EBF (sm) Wall Const. (hours) (m) H/L Description Openings Constr. North South ±318 ±317 14.2 9.5/1 9.5/1 31.5 5.8 100 16 1 N/A N/A >30 * West ±118 22 3.5/1 14 N/A N/A East ±117 15.6 3.5/1 100 59 9.3 1 N/A N/A * Denotes wall faces a street, as per ABC 2012 section 3.2.3.10 - In regards to Limiting Distance and Permitted Max % of Openings, the West wall is considered to face a street and is permitted to have unlimited unprotected openings, as per ABC 2012 section 3.2.3.10 NOTE: - North & East exterior walls will achieve the required 1 hour fire rating by means of upgrading to 2 layer 1/2" Type-X gypsum on their interior face (instead of the current 1 layer 1/2" non specific gypsum) and by means of the listed integral fire resistance of the steel stud within the wall assemblies. As per SB-2 (section 2.3.4) 2 layer 1/2" TypeX gypsum provides a 80 minute resistance. Additionally, as per SB-2 (section 2.3.4) steel studs at 16" O.C. provide a 10 minute resistance. - See Construction Assemblies for further notes on exterior wall constructions 2 1 # 17/02/22 17/02/07 DATE ISSUED FOR TENDER ISSUED FOR REVIEW DESCRIPTION PROJECT WESTWIND CENTRE SPRUCEGROVE, ALBERTA DRAWING COVER PAGE PROJECT NO. 14.178 PROJECT DATE 2017-01-03 DRAWN BY LW CHECKED BY NA SCALE 6" = 1'-0" DRAWING NO. A0.0 LW LW BY 7500 SETBACK EXTENT OF RIGHT OF WAY 12755 7700 7500 SETBACK This drawing, as an instrument of service, is provided by and is the property of Turner Fleischer Architects Inc. The contractor must verify and accept responsibility for all dimensions and conditions on site and must notify Turner Fleischer Architects Inc. of any variations from the supplied information. This drawing is not to be scaled. The architect is not responsible for the accuracy of survey, structural, mechanical, electrical, etc., information shown on this drawing. Refer to the appropriate consultant's drawings before proceeding with the work. Construction must conform to all applicable codes and requirements of authorities having jurisdiction. The contractor working from drawings not specifically marked 'For Construction' must assume full responsibility and bear costs for any corrections or damages resulting from his work. R/W PLAN 132 2525 6.580 LEGEND WASTE MOLOK 6096 (20'- 0") 6096 (20'- 0") 8230 7315 3025 453 15 00 2743 12192 1700 9084 ± 7,250 S.F. ± 2,460 S.F. ± 250 S.F. ± 9,960 S.F. ± 674 S.M. ± 229 S.M. ± 23 S.M. ± 925 S.M. 78 CARS 8.03/1,000 S.F. 78 CARS 8.65/100 S.M. 7315 LOT 1, BLOCK 7 PLAN 162 0361 ZONING STATISTICS BUILDING HEIGHT FRONT YARD SETBACK REAR YARD SETBACK 1500 2400 1950 PROPOSED 5 M. 22.6 M 12.75 M REQUIRED 14M/FOUR STOREY 6.0 M 7.5 M 17 CARS 39 CARS 56 CARS 78 CARS 3 RACKS 4 RACKS PROPOSED LEFT IN/ RIGHT OUT 8 A0.1 KEY PLAN 1 : 2500 SITE B1 5" POURED CONC. SIDEWALK ON 6" COMPACTED "A" GRANULAR BASE (±1.81 ACRES) (±0.73 H.A.) GENERAL NOTES: EDGE OF SIDEWALK CONCRETE CURB G1. SIDEWALK SLOPES TO BE 1/8" / FT. (1%) MAX. IN ALL DIRECTIONS ALONG STOREFRONT, 1/4"/FT. (2%) MAX. IN OTHER AREAS. ASPHALT PAVING BY OTHERS G2. EXPANSION JOINTS ARE TO BE AS SPECIFIED  & AS LOCATED ON ARCHITECTURAL DOCUMENTS. MAX 1:20 SLOPE 120 0 11.79 % BICYCLE PARKING (5% OF TOTAL PARKING) 1950 906 80 0 44 00 ± 0.78 H.A. C2‐VEHICLE ORIENTED COMMERCIAL DISTRICT B 0 110 3407 B 7551 32902 906 2969 6096 7315 (24'- 0") 9 ±1.94 ACRES ZONING STATISTICS B SITE B3 9 SITE B3 AREA PARKING RETAIL (2.5 CARS PER 100 S.M.) REST. (1 CAR PER 6 S.M.) TOTAL PARKING PROPOSED FIRE HYDRANT 7315 5600 G3. REINFORCING TO BE AS PER STRUCTURAL  DOCUMENTS. 12 A G4. CONCRETE TO BE BROOM FINISHED AS PER ARCHITECTURAL SPECIFICATIONS. TYPICAL SIDEWALK NOTES: EDGE OF SIDEWALK 4760 1441 6 3730 1500 16444 6112 MAX 1 :10 SLOPE DEPRESSED CURB 1. WHERE SIDEWALK IS CONTINUOUSLY ADJACENT , REDUCE THE DROPPED CURB AT ENTRANCES TO 3". PATCH & REPAIR ASPHALT PAVING AS REQUIRED 2. FOR SLIPFORMING PROCEDURE A 5% BATTER IS  ACCEPTABLE. A. TREATMENT AT ENTRANCES SHALL CONFORM WITH OPSD‐351.01 B. OUTLET TREATMENT SHALL CONFORM WITH OPSD‐610 SERIES 00 70 46 00 FUTURE CONCRETE SIDEWALK 4000 6096 16444 1829 7315 00 26 6000 SETBACK 911 (±1.94 ACRES) (±0.78 H.A.) 78 CARS (8.03/1,000 S.F.) 800 ± 0.73 H.A. ± 0.35 H.A. ± 0.78 H.A. ± 1.87 H.A. SITE COVERAGE D 6096 A0.1 00 15 6 914 LANDSCAPE 12176 7315 453 3 1813 2 A0.1 9 6096 7315 2 HEAVY DUTY ASPHALT FIRE TRUCK ROUTE 6096 960 5486 3 A0.1 ± 1.81 ACRES ± 0.87 ACRES ± 1.94 ACRES ± 4.62 ACRES PARKING PROVIDED 9 9 480 899 CENTURY ROAD 21946 480 A 12176 A 1829 1973 00 15 16466 SITE B1 AREA SITE B2 AREA SITE B3 AREA TOTAL SITE AREA RETAIL AREA RESTAURANT AREA M./E. ROOM AREA TOTAL BUILDING N AREA 2000 9037 6 6096 8 914 5486 2743 (18'- 0") (9'- 0") B 19202 PROPOSED TRANSFORMER 3073 3619 A0.1 HEAVY DUTY ASPHALT FIRE TRUCK ROUTE B 4564 1890 13 00 0 A0.1 15 00 00 60 6096 PROPOSED RIGHT IN ONLY A0.1 SITE STATISTICS FUTURE SIGNALIZED INTERSECTION 9 24689 5000 7315 A0.1 A0.1 9 IVE 15 00 4 B 2743 2743 2743 00 42 2400 PROPOSED CONCRETE SIDEWALK 7 B W  DR IND W EST C 6195 838 PROPOSED FIRE & TRUCK ROUTE (HEAVY DUTY ASPHALT) ±1.81 ACRES 23.890 3.000 SITE B2 14 6188 (20'- 4") PROPOSED SIGN SITE B1 PROPOSED RIGHT IN / RIGHT OUT A0.1 9 BLOCK 7 KENTON WAY 1 6096 (20'- 0") LOT 1 1 LOT BLOCK 7 PLAN 162 0361 PROPOSED EXIT ARROW FUTURE SIGNALIZED INTERSECTION CENTURY ROAD 6096 (20'- 0") SITE B3 ±1.94 ACRES 78 CARS (8.03/1,000 S.F.) EXTENT OF DP ±0.87 ACRES (GAS BAR) HEAVY DUTY ASPHALT FIRE TRUCK ROUTE 6096 (20'- 0") 12001 (39'- 4") UNIT N.7 RETAIL G.F.A.= (±1,270 S.F.) G.L.A.= (±1,123 S.F.) UNIT N.6 UNIT N.5 UNIT N.4 RETAIL RETAIL RETAIL G.F.A.= G.F.A.= G.F.A.= (±1,240 S.F.) (±1,240 S.F.) (±1,250 S.F.) G.L.A.= G.L.A.= G.L.A.= (±1,188 S.F.) (±1,195 S.F.) (±1,194 S.F.) 24.420 3.000 70 0 UNIT N.3 RETAIL G.F.A.= (±1,150 S.F.) G.L.A.= (±1,109 S.F.) 125800 PROPOSED RIGHT IN ONLY 60 00 UNIT N.2 RETAIL G.F.A.= (±1,100 S.F.) G.L.A.= (±1,051 S.F.) CENTURY ROAD 92 00 A0.1 1821 1500 10 BUILDING N PROPOSED ENTRANCE ARROW B 13 RECYCLE MOLOK GREASE MOLOK 9272 19093 (62' ‐ 8") 1821 UNIT N.1 RESTAURANT G.F.A.= (±2,460 S.F.) G.L.A.= (±2,260 S.F.) 807 3657 1500 4000 (± 9,960 S.F.) 12 Y 16500 9 11 (± 9,960 S.F.) 2 22644 10 A  W 6000 SETBACK M+E ROOM (± 250 S.F.) 3 00 220 PROPOSED PYLON SIGN 9 91 4 0 710 5433 8 13975 1455 7658 7 ON NT KE FUTURE CONCRETE SIDEWALK 00 15 76 00 6 50 00 3600 5 4 RET.N B B 9 B A0.1 C. THE LENGTH OF TRANSITION FROM ONE CURB TYPE TO ANOTHER SHALL BE 3.0M , EXCEPT IN CONJUNCTION WITH GUIDE RAIL, IT SHALL CONFORM TO OPSD‐900 SERIES TYPICAL INTERNAL RAMP / SIDEWALK SITE B2 (±0.87 ACRES) (±0.35 H.A.) B FLARED SIDE SLOPED CURB DP PLAN 1 : 300 D SMOOTH TRANSITON BETWEEN RAMP AND SIDEWALK E OP SL 1 A0.1 CONCRETE CURB BRUSHED CONCRETE FLARED SIDES C/W V‐GROOVES AT 3" O.C. AND ALTERNATE PAINTING YELLOW STRIPES 3 2017-02-21 2 2017-02-10 1 2017-01-11 Issue: Rev: Date: ISSUED FOR TENDER ISSUED FOR PERMIT ISSUED FOR REVIEW Issue / Revision: JJ JJ JJ By 1670 ( 5'- 6" ) NOTES: POURED CONCRETE CURB A 6" LANDSCAPE AS PER SITE PLANNING DOCUMENTS R = 2" BY PERMIT ONLY 4'- 11" R = 1/4" 2'- 9" 1.TREATMENT AT ENTRANCES SHALL CONFORM WITH OPSD‐351.01 2.OUTLET TREATMENT SHALL CONFORM WITH OPSD‐610 SERIES 3. THE LENGHT OF TRANSITION FROM ONE CURB TYPE TO ANOTHER SHALL BE 3.0M, EXCEPT IN CONJUNCTION WITH GUIDE RAIL, IT SHALL CONFORM TO OPSD‐900 SERIES B ASPHALT PAVING TOW AWAY ZONE 6" ON DRIVEWAY "DISABLE PARKING PERMIT" SIGN Rb‐93 (300x450)mm RED REFL. INTERDICTORY SYMBOL, BLUE REFL. SYMBOL OF ACCESS & SYMBOL BORDER, BLACK SYMBOL, LEGEND & BORDER, WHITE REFL. BACKGROUND BUILDING OUTLINE LOCATE RAMP TO MAINTAIN MIN. 1670MM X 1670MM FLAT SURFACE BETWEEN RAMP & BUILDING RAMP MAX. SLOPE 1:10‐1:12 "FIRE ROUTE" SIGN (300x450)mm RED REFL. INTERDICTORY SYMBOL, BLACK SYMBOL, WHITE REFL. "FIRE ROUTE" ON BLACK BACKGROUND, BLACK LEGEND & BORDER, WHITE REFL. BACKGROUND 1500 MINIMUM RAMP WIDTH 2'- 0" DESCRIPTION ( 5'- 6" ) 2'- 0" SIGN 1670 SYMBOL BRUSHED CONCRETE RAMP C/W V‐GROOVES @ 3" O.C. DEPRESSED CONCRETE CURB AT ASPHALT HEIGHT SMOOTH TRANSITION BETWEEN CURB AND ADJACENT SURFACES MAX. 1/2" HIGH BEVELLED SLOPE @ 1:2 6'- 0" C 2'- 0" CONCRETE SIDEWALK MAX. SLOPE 1:20 SIDEWALK PART OF BUILDING CONTRACT. D 2 A0.1 4 CONCRETE CURB SECTION 1 : 175 A0.1 6 FROST SLAB PLAN 1 : 75 A0.1 9 SIGN LEGEND 1 : 40 ASPHALT PAVING ASPHALT IMPREGANTED FIBERBOARD JOINT FILLER "STOP" SIGN Ra‐1 (600x600)mm WHITE REFL. LEGEND & BORDER, RED REFL. BACKGROUND CURB PART OF SITE CONTRACT PATCH & REPAIR ASPHALT PAVING AS REQUIRED SLOPED CURB 10" 2'- 0" SEE NOTES FLARED SIDE "LOADING ZONE" SIGN (300x450)mm RED REFL. INTERDICTORY SYMBOL, BLACK SYMBOL, LEGEND & BORDER, WHITE REFL. BACKGROUND D LOADING ZONE 1/2" ASPHALT IMPREGANTED FIBERBOARD JOINT FILLER @ CONTROL JOINT. SL OP E 1'‐4" 4" RIGID INSULATION AT ALL ENTRANCES A0.1 CURB DEPRESSION 1 : 35 Project : 203 142 307 WESTWIND CENTRE 101 914 130 CONCRTE S.O.G. SEE PLAN - TYP. 130 1829 mm REFER TO SITE PLAN FOR END  CONDITION  (8" LINE OR HATCHED PAINTED ISLAND) 9'‐0" (2743 mm) REFER TO SITE PLAN 9'‐0" (2743 mm) REFER TO SITE PLAN STANDARD PARKING DETAIL 1 : 150 MANUFACTURER (SURFACE): MODEL TYPE: MAGLIN MBR 100 BIKE RACK TEL. 1‐519‐539‐6776 CONC. PIER SEE PLAN STRIPE COLOUR (TYP.) 41 NOTES: CONC. GRADE BEAM SEE PLAN 10" ACCEPTABLE MANUFACTURER: 5" CONCRETE PILE BEYOND SEE PLAN SUREGUARD SHIELD (C/W SUREGUARD "SURE‐SEAL" INSTALLATION KIT.) SIZE: 7" X 42" COLOUR: YELLOW AS MANUFACTURED BY "SUREGUARD SECURITY PRODUCTS (ADAM ULIAS) PO. BOX 1202, 820 VICTORIA ST. N, KITCHNER, ONT. N2G 4G8 PH: (519) 772‐1975  FX: (519) 742‐9256 E‐MAIL: [email protected] DOWELS SEE SECT. F3/S6.3 5 A0.1 FROST SLAB SECTION 1 : 25 SITE PLAN DP PLAN (OR EQUAL TO BE APPROVED BY LANDSCAPE ARCHITECT) SECTION 7 A0.1 BIKE RACK DETAIL 1 : 20 Proj no. : MATERIALS: STEEL TUBING (1.6" DIA.) AND FLATBAR MOUNTING PLATE. DIMENSIONS: HEIGHT: 36" STANDARD CIRCLE WIDTH: 20" FRAME:1.625 DIA. ROUND TUBING WEIGHT: 25 LBS FINISH: ALL STEEL COMPONENTS ARE RUSTPROOFED PRIOR TO POWDERCOATING. INSTALLATION: MAY BE SET IN CONCRETE OR BOLTED DOWN TO SURFACE WITH AN OPTIONAL MOUNTING PLATE. 14.178 Drawn by : JJ Checked by : Date : 2016-11-28 Scale : As indicated RD Drawing No : 10 A0.1 MOLOK DETAIL N.T.S. TRUE NORTH 130 DRIVE AISLE Drawing Name : DWGS. SLOPE AS PER ARCH. A0.1 \\TFAI-CPS\DATA\proj\14178\14178-15. REVIT\14178-A1-61 (DP).rvt PLAN VIEW DOWELS -SEE PLAN CONSTRUCTION NORTH 2104 mm 20' (6096 mm) REFER TO SITE PLAN 203 1. REFER TO SITE PLAN FOR SPECIFIC PROJECT SITE PLANNING DIMENSIONS. 2. ALL PARKING LOT LINE STRIPING TO BE PAINTED WITH PARA PAINT '8 MPI ‐ YELLOW' OR EQUAL. 3. ALL PARKING DIMENSIONS SHOWN ARE MINIMUM. CONFIRM REQUIRED SIZES WITH LOCAL AUTHORITY HAVING JURISDICTION. A0.1 6" CONC. STRUCT. STOOP SEE SECT. F2/S6.3 STRIPES ON 45 ANGLE NOTES: 3 143 38 SPRUCE GROVE, ALBERTA 24'‐0" (7315 mm) 56'‐5" (17200 mm) CENTER OF PARKING ROW TO CENTER OF PARKING ROW EXTERIOR STOOPS DWLS. SEE SECTION F2/S6.3 ASSEMBLY SCHEDULE TURN ER FLEISC HER EXTERIOR WALL TYPES WALL TYPE DESCRIPTION MARK WALL TYPE DESCRIPTION MARK DETAIL EXTERIOR MASONRY WALL CONSTRUCTION @ PARAPET: DETAIL EXTERIOR CONCRETE PANEL WALL CONSTRUCTION (13"-WIDTH) (1 HOUR FIRE-RATED): 2. ALL INTERIOR CONC. BLOCK WALLS HEIGHT TO UNDERSIDE OF METAL ROOF DECK UNLESS NOTED OTHERWISE. IF JOIST OR BEAM CONFLICT, CONSTRUCT FIRE RATED WALL TO U/S OF DECK AS PER DEMISING WALL CONSTRUCTION. - GRID - ROOF SIDE - EXTERIOR GRID 8" 5/8" - 1 3/8" 1/2" GLASSFIBER- REINFORCED CONCRETE PANEL /W STAINLESS STEEL FASTENERS C/W 1" VETICAL/ HORIZONTAL EXTRUSION (REFER TO EXTERIOR FINISHES SCHEDULE) CONTINUOUS PEEL & STICK AIR BARRIER (VAPOUR PERMEABLE) WITH TAPED JOINTS. 5/8" DENSGLASS FIREGUARD SHEATHING BY GEORGIA PACIFIC 8" STEEL STUDS @ 16" O.C. TO BE DESIGNED & STAMPED BY AN ENGINEER - SUBMIT SHOP DRAWINGS FILL VOID WITH GLASS FIBRE BATT INSULATION (8" = R28)(* INDICATES TO USE MINERAL WOOL INSULATION IN PLACE OF GLASS FIBRE BATT) 6 MIL POLY VAPOUR BARRIER. SEAL TO U/S OF ROOF DECK & BASE OF STUD @ FLOOR LEVEL 1/2" DENS DECK SHEATHING 3/4" Z-GIRTS @ 7'-0" O.C. MAX 1 1/2" VERTICAL METAL SIDING 1" 1/2" - 3. CONCRETE FLOORS TO BE SMOOTH & LEVEL WIH A MAXIMUM DEVIATION OF 1/2" IN 20 FEET. READY TO ACCEPT TENANT'S FLOOR FINISH MATERIAL. UNLESS NOTED OTHERWISE ON FLOOR PLAN OR SPECIFICATION - TO COMPLY WITH TENANT REQUIREMENTS. GRID 5/8" 10" 3 1/2" EW-3.1A 2 1/4" 8" 2 1/4" - 4" - 3 1/2" ARCHITECTURAL STONE BLOCK OR BRICK VENEER C/W GALVANIZED BRICK TIES (REFER TO ELEVATIONS FOR FINISH MATERIAL) 1" AIR SPACE (OR AS NOTED ON SECTIONS) PEEL AND STICK AIR BARRIER (VAPOUR PERMEABLE) 5/8" DENSGLASS FIREGUARD SHEATHING BY GEORGIA PACIFIC 5/8" DENSGLASS FIREGUARD SHEATHING BY GEORGIA PACIFIC 2" HORIZ. METAL STRAPPING @ 24" O.C. TO SECURE BATT INSULATION 8" STEEL STUDS @ 16" O.C. TO BE DESIGNED & STAMPED BY AN ENGINEER SUBMIT SHOP DWGS FILL VOID WITH GLASS FIBRE BATT INSULATION (8" = R28). 1" RIGID INSULATION @ EXTERIOR AND INTERIOR FACE OF COLUMNS. 6 MIL POLY VAPOUR BARRIER. SEAL TO U/S OF ROOF DECK & BASE OF STUD @ FLOOR LEVEL 1/2" DENSGLASS FIREGUARD SHEATHING BY GEORGIA PACIFIC 3/4" Z-GIRTS @ 7'-0" O.C. MAX 1 1/2" VERTICAL METAL SIDING 1/2" - T URNER FLEISCHER ARCHITECTS INC.  Lesmill Road Toronto  Canada   Telephone() - turnerfleischer.com 1. ALL STEEL STUDS TO BE DESIGNED & STAMPED BY PROFESSIONAL ENGINEER LICENSED IN ALBERTA-SUBMIT SHOP DRAWINGS EXTERIOR 1' - 1 3/4" EW-1.1A GENERAL CONSTRUCTION NOTES: (APPLICABLE TO ALL ARCH DRAWINGS) This drawing, as an instrument of service, is provided by and is the property of Turner Fleisher Architects Inc. The contractor must verify and accept responsibility for all dimensions and conditions on site and must notify Turner Fleischer Architects Inc. of any variations from the supplied information. This drawing is not to be scaled. The architect is not responsible for the accuracy of survey, structural, mechanical, electrical, etc., information shown on this drawing. Refer to the appropriate consultant's drawings before proceeding with the work. Construction must conform to all applicable codes and requirements of authorities having jurisdiction. The contractor working from drawings not specifically marked 'For Construction' must assume full responsibility and bear costs for any corrections or damages resulting from his work. 4. GYPSUM BOARD WALLS TO BE TAPED & SANDED ONLY, READY TO ACCEPT TENANT'S FINISH UNLESS NOTED OTHERWISE. GYPSUM BOARD TO EXTEND TO UNDERSIDE OF METAL ROOF DECK UNLESS NOTED OTHERWISE. GYPSUM BOARD PIERS OR BUMPS EXTENDING INTO TENANT SPACE WILL NOT BE ACCEPTABLE. (ALSO SEE NOTES FOR WALL TYPES). PROVIDE 1/2" GAP BETWEEN FFE AND BOTTOM OF G.B. 5. ALL INTERIOR STEEL COLUMNS TO BE LEFT EXPOSED & UNFINISHED UNLESS NOTED OTHERWISE. ROOF SIDE 6. EXTERIOR GLAZING UNITS TO BE OF CLEAR ANODIZED FINISH, FIXED HERMETICALLY SEALED DOUBLE GLAZED THERMALLY INSULATED GLASS IN PREFINISHED, THERMALLY BROKEN ALUMINUM FRAME. EXTERIOR MASONRY WALL CONSTRUCTION ULC (1 HOUR FIRE-RATED): - 8. METAL ROOF DECK CEILING TO BE SUITABLE FOR PAINT WITHOUT ADDITIONAL PREPARATION BY TENANT. - RETAIL UNIT - 3 5/8" 2 1/4" 1 3/8" 16. REFER TO STRUCTURAL DRAWINGS FOR ALL SUPPORT CONDITIONS AND STEEL STUD CONSTRUCTION REQUIREMENTS. NOTE: PROVIDE CONTINUOUS SMOKE/FIRE SEAL @ TOP OF GYPSUM BOARD / U/S OF DECK. GYPSUM BOARD TO FOLLOW PROFILE OF DECK FLUTES DESCRIPTION IS FOR REFERENCE ONLY. REFER TO ULC MANUAL. 1 HOURS ULC W407 9 1/4" 2 HOURS RETAIL UNIT ULC W404 INTERIOR WALL CONSTRUCTION: (ULC W404 2 HOUR) - 5/8" TYPE 'X' GYPSUM BOARD TO U/S OF DECK - 1/2" TYPE 'X' GYPSUM BOARD TO U/S OF DECK - 8" STEEL STUDS @ 16" O.C. O U/S OF DECK (OR NOTED OTHERWISE) - FILL CAVITY WITH GLASS FIBRE BATT INSULATION - 1/2" TYPE 'X' GYPSUM BOARD TO U/S OF DECK - 5/8" TYPE 'X' GYPSUM BOARD TO U/S OF DECK 18 2" METAL STRAPS @ 24" O.C. AT ALL DOUBLE WALL CONSTRUCTION TO SECURE BATT INSULATION IN PLACE. 19. NO STRUCTURAL MEMBER TO BE WIDER THAN 8". ALL STRUCTURAL MEMBERS TO FIT WITHIN WALLS. 20. PIPING, TUBING, DUCTS, CHIMNEYS, OPTICAL FIBRE CABLES, ELECTRICAL WIRES AND CABLES, TOTALLY ENCLOSED NON-COMBUSTIBLE RACEWAYS, ELECTRICAL OUTLETS BOXES AND OTHER SIMILAR BUILDING SERVICES THAT PENETRATE A MEMBRANE FORMING PART OF AN ASSEMBLY REQUIRED TO HAVE A FIRERESISTANCE RATING, OR A FIRE SEPARATION, SHALL BE SEALED BY A FIRE STOP SYSTEM. ALSO SEE NOTE #43. 1/2" 5/8" P-1 17. 2'-0" HIGH 1/2" DENS DECK PRIME BEHIND PARAPETS, 2'-0" ABOVE TOP OF DECK CONTINUE WITH 1/2" DENS GLASS BEHIND PARAPETS TO TOP OF PARAPET. APPLICABLE IF PLYWOOD IS NOT USED BEHIND PARAPETS. RETAIL UNIT 8" RETAIL UNIT EXTERIOR RETAIL UNIT 21. AT ALL TRANSITITIONS OF MATERIALS ie: EIFS, BRICK, BLOCK & SIDING, JOINTS TO BE CAULKED C/W BACKER ROD. 22. WRAP ENTIRE PERIMETER OF ROUGH OPENINGS WITH PEEL AND STICK BEFORE INSTALLATION OF WINDOW FRAMES. TYPICAL FOR ALL DOORS AND WINDOWS. 23. PROVIDE 1/2" EXTERIOR GRADE PLYWOOD @ ALL SIGNAGE, AWNINGS, LIGHT FIXTURE LOCATIONS AND, GAS PIPES UNLESS OTHERWISE NOTED. PROVIDE WOOD BLOCKING FOR ALL WASHROOM FIXTURES, ELECT & MECH FIXTURES WHERE APPLICABLE (TYPICAL). GRID 24. ALL EXPOSED FOUNDATION WALLS TO BE SANDBLASTED P-3 GRID 1/2" 8" INTERIOR WALL CONSTRUCTION: (FURRING WALL) -1/2" GYPSUM BOARD TO U/S OF STRUCTURE - 1 5/8" STEEL STUDS @ 16" 0.C. O U/S OF DECK (COMPLETE w/ BRACING STUD SUPPORTS TO SPAN HEIGHT) *NOTE: FRAME AND BOARD TO FULL CONCEAL SERVICES 1/2" DWGS 2" HORIZ. METAL STRAPPING @ 24" O.C. TO SECURE BATT INSULATION 8" STEEL STUDS @ 16" O.C. TO BE DESIGNED & STAMPED BY AN ENGINEER - SUBMIT SHOP DRAWINGS FILL VOID WITH GLASS FIBRE BATT INSULATION (8" = R28)(* INDICATES TO USE MINERAL WOOL INSULATION IN PLACE OF GLASS FIBRE BATT) 6 MIL POLY VAPOUR BARRIER. SEAL TO U/S OF ROOF DECK & BASE OF STUD @ FLOOR LEVEL 1/2" DENS DECK SHEATHING 3/4" Z-GIRTS @ 7'-0" O.C. MAX 1 1/2" VERTICAL METAL SIDING DETAIL 25. GAS PIPES TO BE PAINTED SAME COLOUR AS WALL ON WHICH THEY ARE MOUNTED, W/ YELLOW STRIPES SPACED @ 4'-0" FROM EACH OTHER. PAINT YELLOW 26. GENERAL CONTRACTOR TO ENSURE THAT FIRE RATING OF DEMISING WALLS IS NOT ALTERED FROM THE DESIGNATED WALL CONSTRUCTION LISTED. 1 5/8" - RETAIL UNIT 14. RETURN BLOCK, BRICK AND EIFS AT ALL WINDOW AND DOOR OPENINGS 1/2" MAXIMUM PAST FRAME. INTERIOR WALL CONSTRUCTION: (ULC W407 1HOUR) - 5/8" TYPE 'X' GYPSUM BOARD TO U/S OF DECK - 8" STEEL STUDS @ 16" O.C. O U/S OF DECK (OR NOTED OTHERWISE) - FILL CAVITY WITH GLASS FIBRE BATT INSULATION - 5/8" TYPE 'X' GYPSUM BOARD TO U/S OF DECK P-2 COMPOSITE ALUMINUM PANELS FABRICATED FROM 1/8" THICK COMPOSITE MATERIAL AND BENT TO PROFILE AS INDICATED C/W 5/8" DRY JOINTS SYSTEM BETWEEN PANELS (REFER TO EXTERIOR FINISHES SCHEDULE) CONTINUOUS PEEL & STICK AIR BARRIER (VAPOUR PERMEABLE) WITH TAPED JOINTS. 5/8" DENSGLASS FIREGUARD SHEATHING BY GEORGIA PACIFIC 3 5/8" STEEL STUDS @ 16" O.C. TO BE DESIGNED & STAMPED BY AN ENGINEER SUBMIT SHOP 12. SHOP QUALITY SPRINKLER DRAWINGS COMPLETE WITH HYDRAULIC CALCULATIONS TO BE SUBMITTED TO THE CITY UNDER SEPARATE COVER BY THE SUCCESSFUL CONTRACTOR'S SPRINKLER SYSTEM DESIGN ENGINEER (WHERE SPRINKLERS ARE REQUIRED). 13. ALL DEMISING WALLS TO MAINTAIN A CONTINUOUS FIRE SEPARATION @ U/S OF ROOF DECK. ALSO SEE NOTE # 43. GRID 8" 1' - 1 1/2" WALL TYPE DESCRIPTION MARK 3 5/8" 3 1/2" - GRID 15. ALL R.W.L. TO BE TIGHT TO BACK OF COLUMN. EXTERIOR ALUMINUM PANEL WALL CONSTRUCTION @ PARAPET: EW-2.0A 11. TENANT TO OBTAIN A SEPARATE PERMIT REGARDING EXTERIOR SIGNAGE. 1/2" 5/8" - 10. H.V.A.C. BY GENERAL CONTRACTOR & TO SUIT FINAL TENANT LAYOUT TO FOLLOW. WHERE APPLICABLE GRID INTERIOR WALL TYPES 4" - 3 1/2" ARCHITECTURAL STONE BLOCK OR BRICK VENEER C/W GALVANIZED BRICK TIES (REFER TO ELEVATIONS FOR FINISH MATERIAL) 1" AIR SPACE (OR AS NOTED ON SECTIONS) PEEL AND STICK AIR BARRIER (VAPOUR PERMEABLE) 5/8" DENSGLASS FIREGUARD SHEATHING BY GEORGIA PACIFIC 3 5/8" STEEL STUDS @ 16" o.c. TO BE DESIGNED & STAMPED BY AN ENGINEER SUBMIT SHOP DWGS 2" HORIZ. METAL STRAPPING @ 24" O.C. TO SECURE BATT INSULATION 8" STEEL STUDS @ 16" O.C. TO BE DESIGNED & STAMPED BY AN ENGINEER SUBMIT SHOP DWGS FILL VOID WITH GLASS FIBRE BATT INSULATION (8" = R28). 1" RIGID INSULATION @ EXTERIOR AND INTERIOR FACE OF COLUMNS. 6 MIL POLY VAPOUR BARRIER. SEAL TO U/S OF ROOF DECK & BASE OF STUD @ FLOOR LEVEL 5/8" DENSARMOR PLUS FIREGUARD GYPSUM BOARD BY GEORGIA PACIFIC TO U/S OF DECK 5/8" DENSARMOR PLUS FIREGUARD GYPSUM BOARD BY GEORGIA PACIFIC TO U/S OF DECK EXTERIOR EXTERIOR 5/8" 5/8" - 1' - 5 3/8" EW-1.2 3 1/2" EXTERIOR MASONRY WALL CONSTRUCTION (W/ 3 5/8" PROJECTION) (1 HOUR FIRE-RATED): 1/2" - 8" 5/8" GRID 9. ROUGH-IN OF WASHROOM FIXTURES TO BE BY GENERAL CONTRACTOR & LOCATION TO SUIT FINAL TENANT LAYOUT TO FOLLOW. EACH TENANT TO OBTAIN SEPARATE PERMIT FOR ALL INTERIOR WORK. 1" 1/2" GLASSFIBER- REINFORCED CONCRETE PANEL /W STAINLESS STEEL FASTENERS C/W 1" VETICAL/ HORIZONTAL EXTRUSION (REFER TO EXTERIOR FINISHES SCHEDULE) CONTINUOUS PEEL & STICK AIR BARRIER (VAPOUR PERMEABLE) WITH TAPED JOINTS. 5/8" DENSGLASS FIREGUARD SHEATHING BY GEORGIA PACIFIC 8" STEEL STUDS @ 16" O.C. TO BE DESIGNED & STAMPED BY AN ENGINEER - SUBMIT SHOP DRAWINGS FILL VOID WITH GLASS FIBRE BATT INSULATION (8" = R28)(* INDICATES TO USE MINERAL WOOL INSULATION IN PLACE OF GLASS FIBRE BATT) 6 MIL POLY VAPOUR BARRIER. SEAL TO U/S OF ROOF DECK & BASE OF STUD @ FLOOR LEVEL 5/8" DENSARMOR PLUS FIREGUARD GYPSUM BOARD BY GEORGIA PACIFIC TO U/S OF DECK 5/8" DENSARMOR PLUS FIREGUARD GYPSUM BOARD BY GEORGIA PACIFIC TO U/S OF DECK 5/8" 5/8" 8" 2 1/4" 7. SEE DOOR SCHEDULE FOR DOOR & FRAME TYPE, SIZE & HARDWARE REQUIREMENTS. - 4" 10" EXTERIOR CONCRETE PANEL WALL CONSTRUCTION (13"-WIDTH) (1 HOUR FIRE-RATED): 1' - 0 3/4" - EW-3.1B 5/8" 5/8" - 3 1/2" ARCHITECTURAL STONE BLOCK OR BRICK VENEER C/W GALVANIZED BRICK TIES (REFER TO ELEVATIONS FOR FINISH MATERIAL) 1" AIR SPACE (OR AS NOTED ON SECTIONS) PEEL AND STICK AIR BARRIER (VAPOUR PERMEABLE) 5/8" DENSGLASS FIREGUARD SHEATHING BY GEORGIA PACIFIC 2" HORIZ. METAL STRAPPING @ 24" O.C. TO SECURE BATT INSULATION 8" STEEL STUDS @ 16" O.C. TO BE DESIGNED & STAMPED BY AN ENGINEER SUBMIT SHOP DWGS FILL VOID WITH GLASS FIBRE BATT INSULATION (8" = R28). 1" RIGID INSULATION @ EXTERIOR AND INTERIOR FACE OF COLUMNS. 6 MIL POLY VAPOUR BARRIER. SEAL TO U/S OF ROOF DECK & BASE OF STUD @ FLOOR LEVEL 5/8" DENSARMOR PLUS FIREGUARD GYPSUM BOARD BY GEORGIA PACIFIC TO U/S OF DECK 5/8" DENSARMOR PLUS FIREGUARD GYPSUM BOARD BY GEORGIA PACIFIC TO U/S OF DECK 3 1/2" EXTERIOR - 1' - 1 3/4" EW-1.1B 27. WHERE FIRE RATED WALL RUNS PERPENDICULAR TO METAL DECK, DRYWALL TO FOLLOW DECK CONTOUR C/W 1/2" TO 3/4" GAP. FILL VOIDS WITH FIRE STOP MINERAL WOOL AND FIRE STOP CAULKING/SPRAY TO MAINTAIN WALL FIRE RATING. ALSO SEE NOTE #43. ROOF SIDE 28. HORIZONTAL JOINT @ DEFLECTION TRACK CAULKING TO MAINTAIN FIRE RATING (TYPICAL). 29. VERTICAL DRYWALL CONTROL JOINT TO BE @ EVERY COLUMN SEE SPECIFICATIONS (TYPICAL). 30. PROVIDE STUCCO FINISH ON BACK SIDE OF MOULDING AT ALL PARAPET RETURNS, AND MOULDING TERMINATIONS. - 31. SEAL ALL BRICK TIE PENETRATION @ DENSE GLASS WITH BAKOR ADHESIVE. - 5/8" EXTERIOR ROOF TYPE DESCRIPTION MARK GRID 7 1/8" - ROOF TYPES GRID 8" - COMPOSITE ALUMINUM PANELS FABRICATED FROM 1/8" THICK COMPOSITE MATERIAL AND BENT TO PROFILE AS INDICATED C/W 5/8" DRY JOINTS SYSTEM BETWEEN PANELS (REFER TO EXTERIOR FINISHES SCHEDULE) CONTINUOUS PEEL & STICK AIR BARRIER (VAPOUR PERMEABLE) WITH TAPED JOINTS. 5/8" DENSGLASS FIREGUARD SHEATHING BY GEORGIA PACIFIC 3 5/8" STEEL STUDS @ 16" O.C. TO BE DESIGNED & STAMPED BY AN ENGINEER SUBMIT SHOP DWGS 2" HORIZ. METAL STRAPPING @ 24" O.C. TO SECURE BATT INSULATION 8" STEEL STUDS @ 16" O.C. TO BE DESIGNED & STAMPED BY AN ENGINEER - SUBMIT SHOP DRAWINGS FILL VOID WITH GLASS FIBRE BATT INSULATION (8" = R28)(* INDICATES TO USE MINERAL WOOL INSULATION IN PLACE OF GLASS FIBRE BATT) 6 MIL POLY VAPOUR BARRIER. SEAL TO U/S OF ROOF DECK & BASE OF STUD @ FLOOR LEVEL 5/8" DENSARMOR PLUS FIREGUARD GYPSUM BOARD BY GEORGIA PACIFIC TO U/S OF DECK 5/8" DENSARMOR PLUS FIREGUARD GYPSUM BOARD BY GEORGIA PACIFIC TO U/S OF DECK 5/8" 5/8" EW-2.0B EXTERIOR ALUMINUM PANEL WALL CONSTRUCTION ULC (1 HOUR FIRE-RATED): R-1 RETAIL UNIT 32. 1'-0" OF BATT INSULATION WITHIN PARAPETS ABOVE STEEL DECK. 10" MIN. OF SPRAY FOAM INSULATION WITHIN PARAPETS ABOVE STEEL DECK OR UNLESS OTHERWISE NOTED. PROVIDE SPRAY FOAM OR STUFF BATT INSULATION IN ALL EXPOSED HSS'S THAT PENETRATES THE ROOF DECK (ALSO ROOF SCREENS) AND INTO THE TENANT CEILING TO REDUCE OR REMOVE THERMAL TRANSFER. DETAIL 33. PROVIDE BRICK TIES LENGTHS APPLICABLE FOR AIR SPACES. PROVIDE HEAVY DUTY BRICK TIES WHERE AIR SPACE IS WIDER THAN 1". REFER TO SECTIONS AND PLAN DETAILS FOR AIR SPACE REQUIREMENTS. ROOF CONSTRUCTION: - EPDM ROOF MEMBRANE MECHANICALLY FASTENED C/W PEAGRAVEL BALLAST - 6 MIL POLY ISO - HIGH DENSITY 6" RIGID INSULATION (R30 MIN.) STAGGERED - VAPOUR BARRIER - 1 1/2" METAL ROOF DECK O.W.S.J. (SEE STRUCTURAL) 34. PAINT EXTERIOR H.M. DOOR EDGES. 35. GRADES SHOWN ON FLOOR PLANS, ELEVATIONS, AND SECTIONS DATUM TAGS ARE FOR REFERENCE ONLY. CONTRACTOR IS TO CONFIRM AND COORDINATE ALL GRADES WITH GRADING PLAN 2 1 # 17/02/22 17/02/07 DATE ISSUED FOR TENDER ISSUED FOR REVIEW DESCRIPTION LW LW BY T.O.S. 36. PROVIDE SIDING AT BACK/END AND BACK/SIDE FACE OF ALL PARAPET RETURNS (FACING ROOF) UNLESS OTHERWISE NOTED. REFER TO ROOF SPECIFICATIONS & MANUFACTURER'S SPECIFICATIONS 37. PROVIDE EIFS, CONCRETE SLAB AND MASONRY CONTROL JOINTS WHERE REQUIRED. EXTERIOR CONCRETE PANEL WALL CONSTRUCTION @ PARAPET: - FLOOR TYPE DESCRIPTION MARK GRID 1" 1/2" EXTERIOR F-1 GRID - FLOOR CONSTRUCTION: -CONCRETE SLAB ON GRADE REFER TO STRUCTURAL. CONCRETE MADE SMOOTH AND READY TO RECEIVE FLOOR FINISH BY TENANT. - CRUSHED STONE BASE (MIN 3/4" CLEAR STONE COARSE GRANULAR MATERIAL) DESCRIPTION FLOOR CONSTRUCTION NOTE: -ALL PENETRATIONS THROUGH FLOORS IN CONTRACT WITH GROUND TO BE SEALED -CONCRETE SLAB TO BE MADE SMOOTH & LEVEL READY FOR TENANT FINISH -REFER TO SPECIFICATIONS, STRUCTURAL DRAWING AND SOILS REPORT FOR ADDITIONAL INFORMATION EXTERIOR GRID 40. SHELL GENERAL CONTRACTOR TO PROVIDE 1/2" EXTERIOR GRADE PLYWOOD C/W PEEL AND STICK MEMBRANE PROJECT AT ALL SPANDRAL LOCATIONS. ALSO REFER TO WALL TYPE SCHEDULE. WESTWIND CENTRE 41. SHELL GENERAL CONTRACTOR TO PROVIDE WOOD BLOCKING FOR ALL WASHROOM FIXTURE LOCATIONS. 42. 1/2" EXTERIOR GRADE PLYWOOD IN LIEU OF G.B. C/W PEEL AND STICK MEMBRANE AT ALL SPANDRAL LOCATIONS. ALSO REFER TO WALL TYPE SCHEDULE. 44. REFER TO WALL TYPES, ULC MANUAL AND OBC MATRIX FOR ALL FIRE RATINGS REQUIRED FOR ALL INTERIOR AND EXTERIOR WALLS. NO SUBSTITUTIONS FOR GYPSUM BOARD LISTED IN THE ULC MANUAL FOR THE FIRE RATED WALLS. SUPPLY AND INSTALL FIRE TREATED PLYWOOD WHERE APPLICABLE. 45. FIRE STOP NOTE FOR ALL DOUBLE STUD WALLS WITH AN AIR SPACE MORE THAN ONE INCH. PROVIDE 1/2" EXTERIOR GRADE GYPSUM BOARD FIRE STOP AT 9'-10" (3m) O.C. VERTICAL INTERVALS X 65'-7" (20M) O.C. HORIZONTAL INTERVALS OR FILL CAVITY WITH BATT INSULATION. 46. PROVIDE EACH EXTERIOR POURED CONCERETE STEP, THE TREAD SLOPE SHALL NOT EXCEED 1:50 (2 % SLOPE) REFER TO THE OBC 9.8.4.4 (5). GRID 8" - 1" 4 1/8" 1/2" - 1/2" GLASSFIBER- REINFORCED CONCRETE PANEL /W STAINLESS STEEL FASTENERS C/W 1" VETICAL/ HORIZONTAL EXTRUSION (REFER TO EXTERIOR FINISHES SCHEDULE) 3 5/8" ADJUSTABLE STEEL SUB GIRTS CONTINUOUS PEEL & STICK AIR BARRIER (VAPOUR PERMEABLE) WITH TAPED JOINTS. 5/8" DENSGLASS FIREGUARD SHEATHING BY GEORGIA PACIFIC 8" STEEL STUDS @ 16" O.C. TO BE DESIGNED & STAMPED BY AN ENGINEER - SUBMIT SHOP DRAWINGS FILL VOID WITH GLASS FIBRE BATT INSULATION (8" = R28)(* INDICATES TO USE MINERAL WOOL INSULATION IN PLACE OF GLASS FIBRE BATT) 6 MIL POLY VAPOUR BARRIER. SEAL TO U/S OF ROOF DECK & BASE OF STUD @ FLOOR LEVEL 5/8" DENSARMOR PLUS FIREGUARD GYPSUM BOARD BY GEORGIA PACIFIC TO U/S OF DECK 5/8" DENSARMOR PLUS FIREGUARD GYPSUM BOARD BY GEORGIA PACIFIC TO U/S OF DECK 5/8" 5/8" - DETAIL SPRUCEGROVE, ALBERTA 43 USE HILTI FS 601 OR FS-ONE FLEXIBLE FIRE STOP AT TOP OF ALL FIRE RATED WALLS AT ROOF DECKS AND WALL DRAWING PENETRATIONS TO SUIT RATING OF WALL. TYPICAL. (1 HOUR FIRE-RATED): 1' - 2 7/8" EW-3.0B 39. SHELL GENERAL CONTRACTOR TO CLEAN (SCRAPE AND VACUUM) BOTTOM OF STUD TRACK BEFORE BATT INSULATION INSTALLATION. ROOF SIDE NOTES EXTERIOR CONCRETE PANEL WALL CONSTRUCTION (16"-WIDTH) 38. SHELL GENERAL CONTRACTOR TO BOX IN ALL ELECT. & MECH SERVICES NOT CONCEALED IN WALLS UNLESS OTHERWISE NOTED. PROVIDE ACCESS PANELS WHERE APPLICABLE. FLOOR TYPES 4 1/8" - 1/2" GLASSFIBER- REINFORCED CONCRETE PANEL /W STAINLESS STEEL FASTENERS C/W 1" VETICAL/ HORIZONTAL EXTRUSION (REFER TO EXTERIOR FINISHES SCHEDULE) 3 5/8" ADJUSTABLE STEEL SUB GIRTS CONTINUOUS PEEL & STICK AIR BARRIER (VAPOUR PERMEABLE) WITH TAPED JOINTS. 5/8" DENSGLASS FIREGUARD SHEATHING BY GEORGIA PACIFIC 8" STEEL STUDS @ 16" O.C. TO BE DESIGNED & STAMPED BY AN ENGINEER - SUBMIT SHOP DRAWINGS FILL VOID WITH GLASS FIBRE BATT INSULATION (8" = R28)(* INDICATES TO USE MINERAL WOOL INSULATION IN PLACE OF GLASS FIBRE BATT) 6 MIL POLY VAPOUR BARRIER. SEAL TO U/S OF ROOF DECK & BASE OF STUD @ FLOOR LEVEL 5/8" DENSGLASS FIREGUARD SHEATHING BY GEORGIA PACIFIC 3/4" Z-GIRTS @ 7'-0" O.C. MAX 1 1/2" VERTICAL METAL SIDING 8" - 5/8" EW-3.0A * EXTERIOR WALLS REQUIRING FIRE RESISTANCE RATINGS DOUBLE 1/2" TYPE-X GYPSUM TO BE PROVIDED IN PLACE OF 1/2" GYPSUM BOARD TO ACHIEVE FIRE RESISTANCE OF 1 HOUR BASED ON SB-2. AS PER SECTION 2.3.4 OF SB-2, DOUBLE 1/2" TYPE-X GYPSUM PROVIDES A 80 MINUTE RESISTANCE AND STEEL STUDS SPACED AT 16" O.C. PROVIDE A 10 MINUTE RESISTANCE YIELDING A RESISTANCE NOT LESS THAN 1 HOUR. ADDITIONALLY, MINERAL FIBRE THERMAL INSULATION (ROXUL MINERAL WOOL) WILL BE PROVIDED IN PLACE OF GLASS FIBRE BATT INSULATION, AS PER CAN/ULC-S702 [SB-2, SECTION 2.3.5(2)] REFER TO OBC MATRIX AND FLOOR PLANS FOR EXTENT OF WALLS WHICH REQUIRE FIRE RESISTANCE RATINGS RETAIL UNIT FIRE STOP (EXTERIOR WALLS) AS PER OBC ARTICLE 3.1.11.2 FIRE BLOCKS, CONFORMING TO ARTICLE 3 .1.11. 7., SHALL BE PROVIDED WITHIN ALL WALL ASSEMBLIES HAVING AN AIRSPACE MORE THAN 1” (25MM) THICK. THESE FIRE BLOCKS SHALL BE SPACED SO THAT THE MAXIMUM HORIZONTAL DIMENSION IS NOT MORE THAN 65'-7” (20M) AND THE MAXIMUM VERTICAL DIMENSION IS NOT MORE THAN 9'-10” (3M). AS PER OBC ARTICLE 3.1.11.7., ½” GYPSUM BOARD MAY ACT AS THIS FIRE BLOCK. CONSTRUCTION ASSEMBLIES & NOTES PROJECT NO. 14.178 PROJECT DATE 2017-01-03 DRAWN BY LW CHECKED BY NA SCALE As indicated DRAWING NO. A1.0 TURN ER FLEISC HER T URNER FLEISCHER ARCHITECTS INC.  Lesmill Road Toronto  Canada   Telephone() - turnerfleischer.com This drawing, as an instrument of service, is provided by and is the property of Turner Fleisher Architects Inc. The contractor must verify and accept responsibility for all dimensions and conditions on site and must notify Turner Fleischer Architects Inc. of any variations from the supplied information. This drawing is not to be scaled. The architect is not responsible for the accuracy of survey, structural, mechanical, electrical, etc., information shown on this drawing. Refer to the appropriate consultant's drawings before proceeding with the work. Construction must conform to all applicable codes and requirements of authorities having jurisdiction. The contractor working from drawings not specifically marked 'For Construction' must assume full responsibility and bear costs for any corrections or damages resulting from his work. 1 1x 2 2x 3 4 5 6 7 8 A4.1 1' - 1 1/2" 10' - 0" 32' - 6 3/8" 3' - 6" 5' - 6" 10' - 0" 3' - 6" 7' - 10 5/8" 20' - 0" 3' - 6" 4 A5.2 17' - 2 1/4" 20' - 0" 14' - 4 5/8" 19' - 3" 16' - 1 3/8" 3' - 6" 2' - 6" 3' - 6" 1' - 1 3/8" 15' - 5 7/8" 3 Sim A5.2 Sim 2 A7.1 R.W.L. REFER TO MECH. DWG. D13 STRUCT. BRACING REFER TO STRUCT. DWG FOR DETAIL 1' - 1 3/8" EW-2.0B 1' - 1 3/8" EW-1.1B 3' - 6" 2' - 6" 3' - 6" EW-1.1B 14' - 0" 2 A7.1 10 1/4" P2 D11 P2 (±227 S.F.) (±21 S.M.) 15' - 1 3/4" D10 D09 D08 RADON SUCTION PIT, PIPE REFER TO MECH. DWGS. P2 A EW-2.0B 14' - 9" 13' - 10 5/8" 2 HR.F.R 14' - 8 7/8" EW-3.1B D12 8' - 5 7/8" 21' - 3 1/2" M.E. ROOM D14 R.W.L. REFER TO MECH. DWG. EW-3.1B 17' - 2 1/8" 1' - 1 3/8" 14' - 9" 10 1/4" 6' - 10 1/4" UNIT N.4 UNIT N.5 UNIT N.6 (±1,051 S.F.) (±97.6 S.M.) (FFE 674.35) (±1109 S.F.) (±103 S.M.) (FFE 674.35) ±1,188 S.F. (±110S.M.) (FFE 674.35) ±1,195 S.F. (±111S.M.) (FFE 674.35) ±1,194 S.F. (±110.9 S.M.) (FFE 674.35) ±1,123 S.F. (±104.3 S.M.) (FFE 674.35) 2 A5.2 A4.1 B 2 HR.F.R 2 HR.F.R F-1 2 HR.F.R 2 HR.F.R R.W.L. REFER TO MECH. DWG. F-1 F-1 2 HR.F.R F-1 F-1 64' - 2 1/2" UNIT N.3 2 EW-1.1B 26' - 2 1/8" 59' - 7 7/8" UNIT N.7 F-1 2 HR.F.R 7' - 0 1/8" P2 P2 UNIT N.2 44' - 11" 7' - 9 1/4" 1' - 0" 6' - 0" Bx EW-2.0B 2 A5.1 1 2 A7.1 10 1/4" 19' - 1 3/4" 10 1/4" 19' - 1 3/4" R.W.L. REFER TO MECH. DWG. PROVIDE 'P-3' FURRING WALL FROM U/S OF CANOPY TO U/S OF DECK TO CONCEAL PIPE, TYP Sim 4 A5.1 FURRING WALL F.F. TO U/S OF DECK TO CONCEAL RWL DROP 19' - 2 7/8" 2 A7.3 A5.1 R.W.L. REFER TO MECH. D02 DWG. P3 10 1/4" 19' - 1 3/4" Sim BASE D04 19' - 1 3/4" R.W.L. REFER TO MECH. DWG. PROVIDE 'P-3' FURRING WALL FROM U/S OF CANOPY TO U/S OF DECK TO CONCEAL PIPE, TYP 3 ABOVE EW-3.1B D03 10 1/4" EW-1.1B 2 A7.3 R.W.L. REFER TO MECH. DWG. 1 A5.1 Sim ABOVE EW-3.1B A5.3 BASE EW-1.2 D05 D06 OUTLINE OF AWNING ABOVE (TYP.) EW-1.2 6' - 5 1/2" 20' - 1 1/4" 1' - 6" GLAZING 1' - 6"1' - 4 1/2" 8' - 2 3/4" 3' - 1 1/2" GLAZING 38' - 3 3/4" 16' - 2" 3' - 1 1/2" 7' - 1" GLAZING 20' - 0" Sim BASE C EW-1.2 D07 1 A7.3 OUTLINE OF CANOPY ABOVE (TYP.) OUTLINE OF CANOPY ABOVE (TYP.) 10' - 11 3/4" 2 A7.3 P3 EW-1.2 1' - 4 1/2" 18' - 4 5/8" R.W.L. REFER TO MECH. DWG. PROVIDE 'P-3' FURRING WALL FROM U/S OF CANOPY TO U/S OF DECK TO CONCEAL PIPE, TYP ABOVE EW-3.1B D01 OUTLINE OF AWNING ABOVE (TYP.) 10 1/4" 19' - 7 3/8" GLAZING 8 1/2" D 2' - 6 3/4" OUTLINE OF AWNING ABOVE (TYP.) 37' - 6 1/8" 18' - 10 3/8" 7' - 9 1/4" 2 A7.1 F-1 Sim P2 P2 21' - 6" 4' - 6 1/8" 3' - 0" A5.2 10' - 0" P2 (±2,260 S.F.) (±210 S.M.) (FFE 674.35) 1' - 6" D 9' - 1 3/4" EW-1.1B 4' - 5 1/2" 15' - 5 1/8" 10' - 9" 8" C 1' - 4 3/8" UNIT N.1 EW-3.0B Ax 1 P2 14' - 4 3/8" Bx 18' - 11 3/8" B 5 3' - 6" 20' - 0" 2 HR.F.R 64' - 6 1/8" A4.1 EXTENT OF 1 HOUR FIRE RESISTANCE RATING-REFER TO EXTERIOR ASSEMBLIES Ax D15 20' - 0" 17' - 8 1/2" EW-3.0B A STRUCT. BRACING REFER TO STRUCT. DWG FOR DETAIL 159' - 9 5/8" 38' - 3 3/4" STRUCT. BRACING REFER TO STRUCT. DWG FOR DETAIL 3 STRUCT. BRACING REFER TO STRUCT. DWG FOR DETAIL STRUCT. BRACING REFER TO STRUCT. DWG FOR DETAIL 3' - 0" GLAZING 7' - 7 1/2" GLAZING 20' - 0" 3' - 3 1/2" 16' - 2" GLAZING 40' - 0" 3' - 3 1/2" 7' - 4 3/4" 1' - 6" GLAZING 8' - 0 3/4" 3' - 3 1/2" GLAZING 16' - 6 1/4" 3' - 3 1/2" Sim 2 1 # 17/02/22 17/02/07 DATE ISSUED FOR TENDER ISSUED FOR REVIEW DESCRIPTION 8' - 5 1/2" GLAZING 20' - 0" 19' - 3" 2' - 6 3/4" 163' - 0" PROJECT 1 1x 2 2x 3 4 4 5 6 7 8 WESTWIND CENTRE A4.1 SPRUCEGROVE, ALBERTA DRAWING FLOOR PLAN 1 FLOOR PLAN 1/8" = 1'-0" PROJECT NO. 14.178 PROJECT DATE 2017-01-03 DRAWN BY LW CHECKED BY NA SCALE 1/8" = 1'-0" N DRAWING NO. A2.1 LW LW BY TURN ER FLEISC HER T URNER FLEISCHER ARCHITECTS INC.  Lesmill Road Toronto  Canada   Telephone() - turnerfleischer.com This drawing, as an instrument of service, is provided by and is the property of Turner Fleisher Architects Inc. The contractor must verify and accept responsibility for all dimensions and conditions on site and must notify Turner Fleischer Architects Inc. of any variations from the supplied information. This drawing is not to be scaled. The architect is not responsible for the accuracy of survey, structural, mechanical, electrical, etc., information shown on this drawing. Refer to the appropriate consultant's drawings before proceeding with the work. Construction must conform to all applicable codes and requirements of authorities having jurisdiction. The contractor working from drawings not specifically marked 'For Construction' must assume full responsibility and bear costs for any corrections or damages resulting from his work. 1 1x 2 2x 3 4 5 6 7 8 A4.1 3 38' - 3 3/4" 10' - 0" 10' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 19' - 3" 159' - 4 7/8" 40' - 1" 78' - 5 5/8" 40' - 10 1/4" 4 A5.2 3 A5.2 4' - 9 3/4" HIGH DASH LINE DENOTES PARTITION WALL BELOW. (TYP.) Ax HIGH 6" 7 A7.3 21' - 0 1/2" 6" 1' - 3 3/8" 2' - 11" SLOPE SLOPE 6" A Sim SLOPE HIGH 10' - 9 7/8" Sim 21' - 2 1/2" 7 A7.3 4' - 10 1/4" A Ax 1 A5.2 4' - 10 7/8" 2 Sim 7 A7.3 Sim 7 A7.3 Sim A5.1 A5.1 HIGH 6" E MIN 2% SLOP SLOP E 10' - 0" 13' - 9 3/8" MIN 2% SLOPE MIN 2% SLOP 1 E MI N 2% MI N 2% SLOPE 39' - 11" SLOPE MI N 2% 9' - 2 7/8" SLOPE MI N 2% MI N 2% SLOPE MI N 2% SLOPE 40' - 10" 10' - 9 1/8" SLOPE MI N 2% SLOPE MI N 2% 9' - 0" 9' - 0" DC MIN 2% SLOPE SLOPE MIN 2% SLOPE MIN 2% HIGH A5.3 10' - 0" 13' - 9 3/8" 6" A5.1 5' - 0 1/8" 2 5' - 0 1/8" 1 62' - 4 3/8" MIN 2% SLOPE 5' - 3 3/4" 21' - 4 3/4" HIGH HIGH 10' - 8 3/4" SLOPE 6" B Bx 3 18' - 8 3/4" 21' - 2 3/4" E Sim SLOPE 13' - 1 3/8" MIN 2% SLOP D SLOPE SLOPE 7 A7.3 A4.1 Sim 742' - 8 1/4" A7.3 6" 7 A7.3 Sim 7 A7.3 60' - 6 1/2" A5.2 10' - 9" HIGH 2 SLOPE Bx C 19' - 11 1/4" 4' - 0" 6" 19' - 11 1/4" 5' - 0" 60' - 6 1/2" B 5 62' - 4 3/8" A4.1 MIN 2% SLOPE 37' - 7 5/8" MIN 2% SLOPE MIN 2% SLOPE 2 1 # 17/02/22 17/02/07 DATE ISSUED FOR TENDER ISSUED FOR REVIEW DESCRIPTION 41' - 0 1/4" 159' - 4 7/8" 38' - 3 3/4" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 19' - 3" PROJECT WESTWIND CENTRE SPRUCEGROVE, ALBERTA 1 1x 2 2x 3 4 4 5 6 7 8 DRAWING A4.1 ROOF PLAN PROJECT NO. 14.178 ROOF PLAN 1 1/8" = 1'-0" PROJECT DATE 2017-01-03 DRAWN BY LW CHECKED BY NA SCALE 1/8" = 1'-0" DRAWING NO. A2.2 LW LW BY 1 1 T/O HIGH PARAPET 23' - 0" 2 A5.1 2x 3 4 5 6 A5.1 7 39' - 2 1/4" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 1 7/8" EXTENT OF UNIT N.1 EXTENT OF UNIT N.2 EXTENT OF UNIT N.3 EXTENT OF UNIT N.4 EXTENT OF UNIT N.5 EXTENT OF UNIT N.6 1 EXTENT OF UNIT N.7 EF4 EF10 EF2b EF4 EF3a EF10 EF4 EF3b EF5 EF4 A5.3 EF3a TURN ER FLEISC HER 8 EF10 T URNER FLEISCHER ARCHITECTS INC.  Lesmill Road Toronto  Canada   Telephone() - turnerfleischer.com EF3b This drawing, as an instrument of service, is provided by and is the property of Turner Fleisher Architects Inc. The contractor must verify and accept responsibility for all dimensions and conditions on site and must notify Turner Fleischer Architects Inc. of any variations from the supplied information. This drawing is not to be scaled. The architect is not responsible for the accuracy of survey, structural, mechanical, electrical, etc., information shown on this drawing. Refer to the appropriate consultant's drawings before proceeding with the work. Construction must conform to all applicable codes and requirements of authorities having jurisdiction. The contractor working from drawings not specifically marked 'For Construction' must assume full responsibility and bear costs for any corrections or damages resulting from his work. 3048 (10' - 0") 7010 (23' - 0") 2134 (7' - 0") T/O STEEL 17' - 0" 457 (1' - 6") 762 (2' - 6") T/O LOW PARAPET 18' - 6" T/O GLAZING 10' - 0" EF2a 610 (2' - 0") T/O MID PARAPET 21' - 0" 1x A5.1 3 2 FFE (647.35) 0" DOOR OPERATOR DOOR OPERATOR EF2b 4 EF1 EF7 EF2a EF6 DOOR OPERATOR EF9 EF6 DOOR OPERATOR EF1 EF7 EF5 EF3b DOOR OPERATOR EF3a EF6 DOOR OPERATOR EF7 EF6 EF1 DOOR OPERATOR EF2b EF2a EF2b EF6 EF7 EF6 EF3b SOUTH ELEVATION 1/8" = 1'-0" BRACING REFER TO STRUC. DWG. 1 BRACING REFER TO STRUC. DWG. BRACING REFER TO STRUC. DWG. A5.3 8 5 3 4 A5.2 3 2x 2 4 1x A5.2 20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0" 39' - 2 1/4" EXTENT OF UNIT N.7 EXTENT OF UNIT N.6 EXTENT OF UNIT N.5 EXTENT OF UNIT N.4 EXTENT OF UNIT N.3 EXTENT OF UNIT N.2 EXTENT OF UNIT N.1 EF4 1 EF10 EF4 EF10 EF1 EF4 EF3a EF3b EF10 457 (1' - 6") 3048 (10' - 0") T/O GLAZING 10' - 0" 2134 (7' - 0") 7010 (23' - 0") 762 (2' - 6") T/O LOW PARAPET 18' - 6" T/O STEEL 17' - 0" 6 20' - 1 7/8" 610 (2' - 0") T/O HIGH PARAPET 23' - 0" T/O MID PARAPET 21' - 0" 7 FFE (647.35) 0" 3 EF2a NORTH ELEVATION 1/8" = 1'-0" EF1 1 EF9 2 EF8 EF1 EF9 EF3a EF3b EF1 A5.2 A5.2 D C Bx B Ax A 62' - 4 1/8" T/O HIGH PARAPET 23' - 0" T/O MID PARAPET 21' - 0" PLYWOOD BLOCKING BACK OF WALL FOR SIGNS EXTENT OF UNIT N.7 610 (2' - 0") EF4 EF2bEF3a EF2a EF4 EF2a EF10 BRACING REFER TO STRUC. DWG. EXTERIOR FINISH SCHEDULE EF1 3048 (10' - 0") 13' - 8" T/O GLAZING 10' - 0" 457 (1' - 6") 7010 (23' - 0") 2134 (7' - 0") 762 (2' - 6") T/O LOW PARAPET 18' - 6" T/O STEEL 17' - 0" EF4 FFE (647.35) 0" EF2a EF3b EF6 EF1? EF1 EF1 EF2a EF9 EF2b EAST ELEVATION 2 1/8" = 1'-0" A Ax B Bx C D EF3a 62' - 4 1/8" 610 (2' - 0") EF3a EF10 EF3b EF9 EF1 EF4 EF4 EF2a EF2b EF2a EF4 457 (1' - 6") 2134 (7' - 0") 762 (2' - 6") EF4 EF3b EF6 EF7 ALUMINUM COMPOSITE PANEL: AL-13 ARCHITECTURAL SYSTEMS COLOUR: BLACK WALNUT GLASSFIBRE - REINFORCED CONCRETE PANEL SIDING: "FIBRE C" BY RIEDER COLOUR: ANTHRACITE FINISH: FL FERRO LIGHT GLASSFIBRE - REINFORCED CONCRETE PANEL SIDING: "FIBRE C" BY RIEDER COLOUR: TERRA FINISH: MA MATT DECORATIVE MOULDING:: ALPOLIC SOLID COLOR METAL CORNICE MOULDING TO MATCH PROFILES INDICATED ON DRAWINGS COLOUR: ALUMINUM GREY (AGT-30) EF9 EF10 METAL CANOPY (CLOSED) COLOUR: PAINTED BLACK C/W METAL PRIMER GLAZED DOORS & WINDOWS: CLEAR LOW E GLAZING IN CLEAR ANODIZED THERMALLY BROKEN ALUMINUM FRAMES (UNLESS OTHERWISE NOTED) 2 1 # 17/02/22 17/02/07 DATE ISSUED FOR TENDER ISSUED FOR REVIEW DESCRIPTION SPANDREL GLAZING COLOUR: OPACI-COAT RAL 7005 MOUSE GREY C/W INSULATED BACKPAN, INTERIOR FINISHED WITH STUDS AND GYPSUM WALL BOARD H.M. DOORS & FRAMES: PREFINISHED HOLLOW METAL DOORS AND FRAMES. COLOUR:BLACK PROJECT WESTWIND CENTRE LIGHT FIXTURE: C/W 1/2" EXTERIOR GRADE PLYWOOD BACKING (FIRE RATED WHERE APPLICABLE). SIGNAGE: SIGNAGE C/W 3/4" EXTERIOR GRADE PLYWOOD FOR SIGNAGE LOCATIONS @ EIFS CONSTRUCTION, UNLESS OTHERWISE NOTED (FIRE RATED WHERE APPLICABLE). SPRUCEGROVE, ALBERTA DRAWING ELEVATIONS PROJECT NO. 14.178 PROJECT DATE 2017-01-03 DRAWN BY LW 3048 (10' - 0") 7010 (23' - 0") T/O LOW PARAPET 18' - 6" T/O STEEL 17' - 0" T/O GLAZING 10' - 0" EXTENT OF UNIT N.1 ALUMINUM COMPOSITE PANEL: AL-13 ARCHITECTURAL SYSTEMS COLOUR: SLATE EF5 EF8 BRACING REFER TO STRUC. DWG. T/O HIGH PARAPET 23' - 0" T/O MID PARAPET 21' - 0" CONCRETE BLOCK (A) AND SILLS (B): SHOULDICE BLOCK & SILLS: SEE MANUFACTURER'S STANDARD SPECIFICATIONS MORTAR, CONTROL JOINT AND CAULKING COLOURS TO MATCH MASONRY UNIT COLOUR COLOUR: COLBY (TAPESTRY FINISH) CHECKED BY NA SCALE As indicated FFE (647.35) 0" 5 WEST ELEVATION 1/8" = 1'-0" EF3b EF1 EF3a EF1 EF2a EF9 EF1 EF6 EF7 DRAWING NO. A4.1 LW LW BY D C D C D C TURN ER FLEISC HER T URNER FLEISCHER ARCHITECTS INC. 2' - 6" 1' - 6" 1' - 6 1/4" 14' - 11 7/8" 7' - 0" 4 1/8" 1' - 5" 1/2" JOINT FILLER (TYP.) 2" RIGID INSULATION OVER FULL HEIGHT OF FOUNDATION BELOW FINISHED GRADE GRADE ELEVATION @ SIDEWALKS TO BE 1-1/2" BELOW TOP OF FINISH FLOOR. REFER TO CIVIL DRAWINGS FOR FINAL GRADE. Sim FFE (647.35) 0" SLOPE 4 1/8" 1' - 1 1/4" CONCRETE GRADE BEAM REFER TO STRUCTURAL DWGS 2 1 # 6" 6" 6" CONCRETE GRADE BEAM. REFER TO STRUCTURAL DWGS 8" 8" Sim 2" RIGID INSULATION OVER FULL HEIGHT OF WALL BELOW FINISHED GRADE FFE (647.35) 0" 7 A7.2 1' - 6" 8 A7.2 Sim 1' - 6" 5 3/8" 7 A7.2 1' - 6" 6" 1' - 6" CONCRETE GRADE BEAM REFER TO STRUCTURAL DWGS GRADE ELEVATION @ SIDEWALKS TO BE 1-1/2" BELOW TOP OF FINISH FLOOR. REFER TO CIVIL DRAWINGS FOR FINAL GRADE. EW-1.1B FROST SLAB FFE (647.35) 0" RETAIL UNIT 10' - 0" 10' - 0" RETAIL UNIT MIN. TENANT CLEARANCE STRUC. STEEL GIRT. REFER TO STRUC. DWGS. STRUCTURAL STEEL GIRT. REFER TO STRUCT. DWGS.. CLEAR ANODIZED ALUMINUM FRAMES AND TEMPERED GLAZING. REFER TO EXTERIOR ELEVATIONS AND FINISH SCHEDULE. EW-1.1 F-1 FFE (647.35) 0" 1 1/4" 1' - 5 7/8" 2" 6" T/O GLAZING 10' - 0" GRADE ELEVATION @ SIDEWALKS TO BE 1-1/2" BELOW TOP OF FINISH FLOOR. REFER TO CIVIL DRAWINGS FOR FINAL GRADE. 1/2" JOINT FILLER (TYP.) 8" Sim 1 1/4" Sim 3 1/2" 11 1/2" 1' - 6" 2" 10' - 0" ENTRANCE DOOR . REFER TO EXTERIOR ELEVATIONS AND DOOR SCHEDULE. 3 A7.2 EW-3.1B 6 A7.2 Sim STRUC. STEEL BEAM. REFER TO STRUC. DWGS. STEEL STUD FRAMING & METAL FURRING RETAIL UNIT 10' - 0" 13' - 7 7/8" RETAIL UNIT Sim 3 5/8" 5/8" 5/8" EW-3.0B 1' - 3" T/O GLAZING 10' - 0" 2 A7.2 STRUCTURAL STEEL BEAM. REFER TO STRUCT. DWGS.. 2' - 5 5/8" MIN. TENANT CLEARANCE 14' - 11 7/8" T/O GLAZING 10' - 0" 1 A7.2 2" EW-3.1B 9' - 4" 23' - 0" T/O GLAZING 10' - 0" PLYWOOD IN LIEU OF EXTERIOR SHEATHING FOR TENANT SIGNAGE. REFER TO ELEVATION FOR LOCATION AND SIZES. SIGNS & HORIZONAL & VERTICAL ALUMINUM BARS PROVIDED AND INSTALLED BY SIGN MANUFACTURER. 3' - 7 7/8" CLEAR ANODIZED ALUMINUM FRAMES AND TEMPERED GLAZING. REFER TO EXTERIOR ELEVATIONS AND FINISH SCHEDULE. CLEAR ANODIZED ALUMINUM FRAMES AND TEMPERED GLAZING. REFER TO EXTERIOR ELEVATIONS AND FINISH SCHEDULE. EW-3.1A Sim Sim 21' - 0" 1' - 3" 6 A7.2 2' - 10 3/8" STRUC. STEEL GIRT. REFER TO STRUC. DWGS. 1 A7.2 7' - 0" STRUCTURAL STEEL BEAM. REFER TO STRUCT. DWGS.. 7' - 0" 7' - 0" 6" 1' - 10 1/8" 3 3/4" 6" Sim DECORATIVE MOULDING. REFER TO EXTERIOR ELEVATIONS. PLYWOOD IN LIEU OF EXTERIOR SHEATHING FOR TENANT SIGNAGE. REFER TO ELEVATION FOR LOCATION AND SIZES. SIGNS & HORIZONAL & VERTICAL ALUMINUM BARS PROVIDED AND INSTALLED BY SIGN MANUFACTURER. EW-3.0A T/O LOW PARAPET 18' - 6" T/O STEEL 17' - 0" EW-2.0B STRUCTURAL STEEL GIRT. REFER TO STRUCT. DWGS.. R-1 T/O STEEL 17' - 0" STRUC. STEEL BEAM. REFER TO STRUC. DWGS. 6 A7.2 T/O LOW PARAPET 18' - 6" 1' - 6" 2 A7.2 T/O STEEL 17' - 0" 1' - 10 3/8" 1' - 10 1/8" Sim STRUCTURAL STEEL GIRT. REFER TO STRUCT. DWGS.. DECORATIVE MOULDING. REFER TO EXTERIOR FINISH SCHEDULE FOR COLOUR. 21' - 0" T/O LOW PARAPET 18' - 6" R-1 EW-2.0B 10' - 0" R-1 5' - 6" 2 A7.2 Sim T/O MID PARAPET 21' - 0" PRE-FINISHED ALUMINUM CAP FLASHING. REFER TO EXTERIOR FINISH SCHEDULE FOR COLOUR. EW-2.0A 1' - 6" 1' - 6" STEEL STUD FRAMING & METAL FURRING STEEL STUD FRAMING & METAL FURRING PLYWOOD IN LIEU OF EXTERIOR SHEATHING FOR TENANT SIGNAGE. REFER TO ELEVATION FOR LOCATION AND SIZES. SIGNS & HORIZONAL & VERTICAL ALUMINUM BARS PROVIDED AND INSTALLED BY SIGN MANUFACTURER. 8" T/O MID PARAPET 21' - 0" PRE-FINISHED ALUMINUM CAP FLASHING. REFER TO EXTERIOR FINISH SCHEDULE FOR COLOUR. 3/4" PLYWOOD SHEATHING SLOPED ON 2"x2" WOOD BLOCKING ON HORIZONTAL 3/4" PLYWOOD SHEATHING 2' - 6" 2' - 0" 2' - 6" EW-2.0A Sim 1 A7.2 STRUC. OUTRIGER C/W STEEL PLATE TO SUPPORT BRICK. REFER TO STRUC. DWGS. STRUCTURAL STEEL GIRT. REFER TO STRUCT. DWGS.. T/O MID PARAPET 21' - 0" T/O STEEL 17' - 0" DECORATIVE MOULDING. REFER TO EXTERIOR FINISH SCHEDULE FOR COLOUR. Sim 3/4" PLYWOOD SHEATHING SLOPED ON 2"x2" WOOD BLOCKING ON HORIZONTAL 3/4" PLYWOOD SHEATHING STRUCTURAL STEEL GIRT. REFER TO STRUCT. DWGS.. 18' - 6" 1 A7.2 DECORATIVE MOULDING. REFER TO EXTERIOR ELEVATIONS. T/O LOW PARAPET 18' - 6" This drawing, as an instrument of service, is provided by and is the property of Turner Fleisher Architects Inc. The contractor must verify and accept responsibility for all dimensions and conditions on site and must notify Turner Fleischer Architects Inc. of any variations from the supplied information. This drawing is not to be scaled. The architect is not responsible for the accuracy of survey, structural, mechanical, electrical, etc., information shown on this drawing. Refer to the appropriate consultant's drawings before proceeding with the work. Construction must conform to all applicable codes and requirements of authorities having jurisdiction. The contractor working from drawings not specifically marked 'For Construction' must assume full responsibility and bear costs for any corrections or damages resulting from his work. 8" PRE-FINISHED ALUMINUM CAP FLASHING. REFER TO EXTERIOR FINISH SCHEDULE FOR COLOUR. PRE-FINISHED ALUMINUM CAP FLASHING. REFER TO EXTERIOR FINISH SCHEDULE FOR COLOUR. T/O HIGH PARAPET 23' - 0" D C 3/4" PLYWOOD SHEATHING SLOPED ON 2"x2" WOOD BLOCKING ON HORIZONTAL 3/4" PLYWOOD SHEATHING 3/4" PLYWOOD SHEATHING SLOPED ON 2"x2" WOOD BLOCKING ON HORIZONTAL 3/4" PLYWOOD SHEATHING  Lesmill Road Toronto  Canada   Telephone() - turnerfleischer.com 1/2" JOINT FILLER (TYP.) 17/02/22 17/02/07 DATE ISSUED FOR TENDER ISSUED FOR REVIEW DESCRIPTION 4 1/8" 1' - 4 3/4" 1/2" JOINT FILLER (TYP.) CONCRETE GRADE BEAM TO STRUCTURAL DWGS 2" RIGID INSULATION OVER FULL HEIGHT OF GRADE BEAM BELOW FINISHED GRADE 2" RIGID INSULATION OVER FULL HEIGHT OF GRADE BEAM BELOW FINISHED GRADE PROJECT WESTWIND CENTRE SPRUCEGROVE, ALBERTA DRAWING SECTION THROUGH AT ENTRANCE WITH ALUMINUM PANEL WALL AND HIGH PARAPET 1 1/2" = 1'-0" SECTION THROUGH ALUMINUM PANEL/ CANOPY/ GLAZING WALL BASE BRICK WALL@ SOUTH WALL 2 1/2" = 1'-0" SECTION THROUGH CONCRETE PANEL/ CANOPY/ GLAZING WALL BASE BRICK WALL@ LOW PARAPET 3 1/2" = 1'-0" EXTERIOR WALL SECTIONS SECTION THROUGH ENTRANCE AT CONCRETE PANEL SIDING AND MID PARAPET 4 1/2" = 1'-0" PROJECT NO. 14.178 PROJECT DATE 2017-01-03 DRAWN BY LW CHECKED BY NA SCALE 1/2" = 1'-0" DRAWING NO. A5.1 LW LW BY TURN ER FLEISC HER T URNER FLEISCHER ARCHITECTS INC.  Lesmill Road Toronto  Canada   Telephone() - turnerfleischer.com 8 This drawing, as an instrument of service, is provided by and is the property of Turner Fleisher Architects Inc. The contractor must verify and accept responsibility for all dimensions and conditions on site and must notify Turner Fleischer Architects Inc. of any variations from the supplied information. This drawing is not to be scaled. The architect is not responsible for the accuracy of survey, structural, mechanical, electrical, etc., information shown on this drawing. Refer to the appropriate consultant's drawings before proceeding with the work. Construction must conform to all applicable codes and requirements of authorities having jurisdiction. The contractor working from drawings not specifically marked 'For Construction' must assume full responsibility and bear costs for any corrections or damages resulting from his work. A 3/4" PLYWOOD SHEATHING SLOPED ON 2"x2" WOOD BLOCKING ON HORIZONTAL 3/4" PLYWOOD SHEATHING PRE-FINISHED ALUMINUM CAP FLASHING. REFER TO EXTERIOR FINISH SCHEDULE FOR COLOUR. A STRUCTURAL STEEL GIRT. REFER TO STRUCT. DWGS.. DECORATIVE MOULDING. REFER TO EXTERIOR FINISH SCHEDULE FOR COLOUR. Sim 3/4" PLYWOOD SHEATHING SLOPED ON 2"x2" WOOD BLOCKING ON HORIZONTAL 3/4" PLYWOOD SHEATHING 2 A7.2 1' - 6" T/O STEEL 17' - 0" T/O STEEL 17' - 0" 3 A7.2 STRUCTURAL STEEL GIRT. REFER TO STRUCT. DWGS.. Sim Sim R-1 1 A7.2 T/O LOW PARAPET 18' - 6" DECORATIVE MOULDING. REFER TO EXTERIOR FINISH SCHEDULE FOR COLOUR. 1 A7.2 2 A7.2 3 A7.2 EW-1.1A Sim STRUCTURAL STEEL GIRT. REFER TO STRUCT. DWGS.. 1 A7.2 DECORATIVE MOULDING. REFER TO EXTERIOR ELEVATIONS. 2 A7.2 DECORATIVE MOULDING. REFER TO EXTERIOR FINISH SCHEDULE FOR COLOUR. STRUCTURAL STEEL BEAM. REFER TO STRUCT. DWGS.. Sim Sim T/O LOW PARAPET 18' - 6" T/O STEEL 17' - 0" Sim 2 A7.2 EW-3.0A T/O LOW PARAPET 18' - 6" 3 A7.2 Sim T/O STEEL 17' - 0" Sim EW-3.0B STRUCTURAL STEEL BEAM. REFER TO STRUCT. DWGS.. 7' - 0" 7' - 0" T/O MID PARAPET 21' - 0" EW-1.1A STRUCTURAL STEEL BEAM. REFER TO STRUCT. DWGS.. 7' - 0" Sim ALUMINUM CAP FLASHING. REFER TO EXTERIOR FINISH SCHEDULE FOR COLOUR. 2' - 6" Sim 1' - 6" T/O LOW PARAPET 18' - 6" PRE-FINISHED ALUMINUM CAP FLASHING. REFER TO EXTERIOR FINISH SCHEDULE FOR COLOUR. STRUCTURAL STEEL GIRT. REFER TO STRUCT. DWGS.. 1' - 6" 2' - 6" STEEL STUD FRAMING & METAL FURRING PRE-FINISHED ALUMINUM CAP FLASHING. REFER TO EXTERIOR FINISH SCHEDULE FOR COLOUR. 4 1/4" EW-2.0A T/O HIGH PARAPET 23' - 0" PRE-FINISHED 1' - 6" 8" 1 A7.2 3/4" PLYWOOD SHEATHING SLOPED ON 2"x2" WOOD BLOCKING ON HORIZONTAL 3/4" PLYWOOD SHEATHING 3' - 4" 2' - 0" 8 T/O MID PARAPET 21' - 0" PLYWOOD IN LIEU OF EXTERIOR SHEATHING FOR TENANT SIGNAGE. REFER TO ELEVATION FOR LOCATION AND SIZES. SIGNS & HORIZONAL & VERTICAL ALUMINUM BARS PROVIDED AND INSTALLED BY SIGN MANUFACTURER. 3/4" PLYWOOD SHEATHING SLOPED ON 2"x2" WOOD BLOCKING ON HORIZONTAL 3/4" PLYWOOD SHEATHING 3 A7.2 Sim EW-2.0B 21' - 0" T/O GLAZING 10' - 0" 18' - 6" T/O GLAZING 10' - 0" 18' - 6" T/O GLAZING 10' - 0" 21' - 0" EW-1.1B EW-1.1B EW-3.1B 10' - 0" 10' - 0" 10' - 0" 13' - 8" RETAIL UNIT GRADE ELEVATION @ SIDEWALKS TO BE 1-1/2" BELOW TOP OF FINISH FLOOR. REFER TO CIVIL DRAWINGS FOR FINAL GRADE. RETAIL UNIT 7' - 2" RETAIL UNIT RETAIL UNIT # EW-1.2 CONCRETE GRADE BEAM REFER TO STRUCTURAL DWGS 1 GRADE ELEVATION @ SIDEWALKS TO BE 1-1/2" BELOW TOP OF FINISH FLOOR. REFER TO CIVIL DRAWINGS FOR FINAL GRADE. 3 7/8" 1/2" JOINT FILLER (TYP.) 1' - 4 1/2" 2" RIGID INSULATION OVER FULL HEIGHT OF GRADE BEAM BELOW FINISHED GRADE SECTION THROUGH ALUMINUM PANEL/ BASE BRICK WALL@ MID PARAPET 1/2" = 1'-0" CONCRETE PIER AND PILE. REFER TO STRUCTURAL DWGS 2 SECTION THROUGH BRICK WALL@ LOW PARAPET 1/2" = 1'-0" EW-1.2 FFE (647.35) 0" FFE (647.35) 0" 6" 5 A7.2 DESCRIPTION Sim 1' - 6" 1' - 6" GRADE ELEVATION @ SIDEWALKS TO BE 1-1/2" BELOW TOP OF FINISH FLOOR. REFER TO CIVIL DRAWINGS FOR FINAL GRADE. CONTINUOUS THRU-WALL FLASHING MIN. 6" FFE (647.35) 0" 6" FFE (647.35) Level 14 0" 4 A7.2 Sim DATE CONTINUOUS THRUWALL FLASHING 5" CONTINUOUS THRUWALL FLASHING GRADE ELEVATION @ SIDEWALKS TO BE 1-1/2" BELOW TOP OF FINISH FLOOR. REFER TO CIVIL DRAWINGS FOR FINAL GRADE. 1/2" JOINT FILLER (TYP.) CONCRETE GRADE BEAM. REFER TO STRUCTURAL DWGS 2" RIGID INSULATION OVER FULL HEIGHT OF GRAD BEAM BELOW FINISHED GRADE 1/2" JOINT FILLER (TYP.) 8 A7.2 CONCRETE GRADE BEAM REFER TO STRUCTURAL DWGS Sim 2" RIGID INSULATION OVER FULL HEIGHT OF GRADE BEAM BELOW FINISHED GRADE 3 SECTION THROUGH BRICK WALL/ DOOR@ LOW PARAPET 1/2" = 1'-0" PROJECT WESTWIND CENTRE 1/2" JOINT FILLER (TYP.) SPRUCEGROVE, ALBERTA 2" RIGID INSULATION OVER FULL HEIGHT OF GRADE BEAM BELOW FINISHED GRADE DRAWING EXTERIOR WALL SECTIONS 4 SECTION THROUGH CONCRETE PANEL WALL @ MID PARAPET 1/2" = 1'-0" PROJECT NO. 14.178 PROJECT DATE 2017-01-03 DRAWN BY LW CHECKED BY NA SCALE 1/2" = 1'-0" DRAWING NO. A5.2 BY TURN ER FLEISC HER T URNER FLEISCHER ARCHITECTS INC.  Lesmill Road Toronto  Canada   Telephone() - turnerfleischer.com This drawing, as an instrument of service, is provided by and is the property of Turner Fleisher Architects Inc. The contractor must verify and accept responsibility for all dimensions and conditions on site and must notify Turner Fleischer Architects Inc. of any variations from the supplied information. This drawing is not to be scaled. The architect is not responsible for the accuracy of survey, structural, mechanical, electrical, etc., information shown on this drawing. Refer to the appropriate consultant's drawings before proceeding with the work. Construction must conform to all applicable codes and requirements of authorities having jurisdiction. The contractor working from drawings not specifically marked 'For Construction' must assume full responsibility and bear costs for any corrections or damages resulting from his work. D 3/4" PLYWOOD SHEATHING SLOPED ON 2"x2" WOOD BLOCKING ON HORIZONTAL 3/4" PLYWOOD SHEATHING PRE-FINISHED ALUMINUM CAP FLASHING. REFER TO EXTERIOR FINISH SCHEDULE FOR COLOUR. STRUCTURAL STEEL GIRT. REFER TO STRUCT. DWGS.. DECORATIVE MOULDING. REFER TO EXTERIOR FINISH SCHEDULE FOR COLOUR. T/O MID PARAPET 21' - 0" 2' - 6" 3 A7.1 Sim 7 A7.1 R-1 R-1 T/O STEEL 17' - 0" FILL ALL VOIDS & DECK FLUTES WITH MINERAL WOOL FIRESTOPPING INSULATION. PROVIDE FIRESTOP WITH 1" GAP BETWEEN TOP OF GYPSUM AND U/S OF ROOF DECK (FIRESTOP SHOULD OVERLAP METAL DECK AND GYPSUM BOARD 1" MIN) 1' - 6" T/O LOW PARAPET 18' - 6" T/O STEEL 17' - 0" T/O STEEL 17' - 0" FILL ALL VOIDS & DECK FLUTES WITH MINERAL WOOL FIRESTOPPING INSULATION. PROVIDE FIRESTOP WITH 1" GAP BETWEEN TOP OF GYPSUM AND U/S OF ROOF DECK (FIRESTOP SHOULD OVERLAP METAL DECK AND GYPSUM BOARD 1" MIN) PROVIDE SLIP TRACK @ DECK DO NOT ATTACH STUD TO TRACK PROVIDE SLIP TRACK @ DECK DO NOT ATTACH STUD TO TRACK OPEN WEB STEEL JOIST. REFER TO STRUCTURAL DRAWINGS 21' - 0" T/O GLAZING 10' - 0" 3 3/4" 6" 6 A7.2 OPEN WEB STEEL JOIST. REFER TO STRUCTURAL DRAWINGS P1 WALLS TO BE FRAMED AROUND OWSJ UP TO T/O STEEL WALLS TO BE FRAMED AROUND OWSJ UP TO T/O STEEL Sim 6" 1' - 10 1/8" 1' - 4 5/8" 1' - 9 7/8" 7' - 0" 1' - 6 3/4" STRUCTURAL STEEL GIRT. REFER TO STRUCT. DWGS.. 2 HOUR ULC W404 P1 1/2" 5/8" MECH/ELEC ROOM RETAIL UNIT 9' - 4" 10' - 0" 8" P2 1/2" 5/8" RETAIL RETAIL SOILD FILL ALL VOIDS W/MORTAR AT TOP AND BOTTOM OF WALL CONCRETE SLAB REFER TO STRUCTURAL F-1 RETAIL NOTE: SOILD FILL ALL VOIDS W/ MORTAR AT BRACKET LOCATIONS AND ROOF LADDER CONCRETE SLAB REFER TO STRUCTURAL NOTE: PENETRATIONS IN FIRE RATED WALLS MUST BE SEALED WITH A FIRE STOP AROUND THEIR PERIMETER F-1 F.F.E = 337.40 0" NOTE: PENETRATIONS IN FIRE RATED WALLS MUST BE SEALED WITH A FIRE STOP AROUND THEIR PERIMETER # DATE DESCRIPTION F.F.E = 337.40 0" GRADE ELEVATION @ SIDEWALKS TO BE 1-1/2" BELOW TOP OF FINISH FLOOR. REFER TO CIVIL DRAWINGS FOR FINAL GRADE. CONCRETE GRADE BEAM REFER TO STRUCTURAL DWGS 1' - 6" 6" 8" FFE (647.35) 0" Sim 1/2" JOINT FILLER (TYP.) PROJECT WESTWIND CENTRE 2" RIGID INSULATION OVER FULL HEIGHT OF GRADE BEAM BELOW FINISHED GRADE SPRUCEGROVE, ALBERTA 2 ULC 407 -1 HOUR DEMISING WALL 1/2" = 1'-0" 3 ULC 404 - 2 HOUR DEMISING WALL SECTION 1/2" = 1'-0" DRAWING WALL SECTION PROJECT NO. SECTION THROUGH CONCRETE PANEL/ CANOPY/ GLAZING@ MID PARAPET 1 1/2" = 1'-0" 14.178 PROJECT DATE 2017-01-03 DRAWN BY LW CHECKED BY NA SCALE 1/2" = 1'-0" DRAWING NO. A5.3 BY EXTEND VAPOUR BARRIER AND ADHERE TO DRAIN FLANGE ROOF DRAIN REFER TO MECHANICAL DRAWINGS REFER TO ROOF PLAN FOR ROOF TYPE EXTEND ROOFING OVER FLANGE INSULATED METAL SLEEVE GAS LINE - SEE MECHANICAL DWG'S FOR EXTENT AND LOCATION. HIGH GRADE SEALANT BROKEN LINE DENOTES 12" x 24" INSULATION PAD BELOW GAS LINE SUPPORT. PRE FINISHED METAL HOOD T URNER FLEISCHER ARCHITECTS INC.  Lesmill Road Toronto  Canada   Telephone() - turnerfleischer.com GAS LINE SUPPORT PREFABRICATED PLASTIC SUPPORT SPACE @ 8'-0" 0.C. AND WITHIN 2'-0" OF CHANGES IN DIRECTION. ADHESIVE PLAN PIPE BRACKET 9" SEAM FLASHING CONTINUOUS BEAD OF LAP SEALANT (SEE NOTES) PENETRATION (HOT STACK) (SEE NOTES) BONDING ADHESIVE (ADHERED SYSTEM ONLY) GAS LINE PIPING REFER TO ROOF PLAN FOR LOCATION AND EXTENT OF ROOF DRAINS CLAMP 2" (50.8 mm) PRE FABRICATED GAS LINE SUPPORT INSULATION PAD: 1 1/2" THICK HIGH DENSITY EXTRUDED POLYSTYRENE. PROVIDE SOLID BLOCKING IN FLUTES NOTES: 1) COMPLY WITH ROOF MANUFACTURER DETAILS AND SPECIFICATION. 2) PENETRATION MUST BE ANCHORED TO ENSURE STABILITY 3) WHEN OUTSIDE DIAMETER OF THE POPE EXCEEDS 18" (457.2 mm), ADDITIONAL FIELD MEMBRANE SECUREMENT REQUIRED. 4) APPLY LAP SEALANT AROUND ENTIRE PERIMETER OF 2 PLYFLASHING This drawing, as an instrument of service, is provided by and is the property of Turner Fleisher Architects Inc. The contractor must verify and accept responsibility for all dimensions and conditions on site and must notify Turner Fleischer Architects Inc. of any variations from the supplied information. This drawing is not to be scaled. The architect is not responsible for the accuracy of survey, structural, mechanical, electrical, etc., information shown on this drawing. Refer to the appropriate consultant's drawings before proceeding with the work. Construction must conform to all applicable codes and requirements of authorities having jurisdiction. The contractor working from drawings not specifically marked 'For Construction' must assume full responsibility and bear costs for any corrections or damages resulting from his work. REFER TO CONSTRUCTION NOTES FOR ROOF ASSEMBLY 2" (50.8 mm) PIPE BRACKET: OF SIZE AND TYPE TO PERMIT THERMAL MOVEMENT OF GAS LINE PIPE. FASTEN BRACKET TO SUPPORT. TURN ER FLEISC HER CONTINUOUS BEAD OF LAP SEALANT (SEE NOTES) 5" SEAM FLASHING FOUR PLY BUILT UP ROOF MEMBRANE ROOF MEMBRANE 1 INSULATION INSULATION SUBSTRATE SUBSTRATE ELEVATION / SECTION ROOF DRAIN DETAIL 1 1/2" = 1'-0" 3 GAS LINE SUPPORT BLOCK DETAIL 1" = 1'-0" 6 ROOF VENT DETAIL 6" = 1'-0" Gr STEEL COLUMN SEE STRUCT. DWGS. FOR SIZE RETAIL UNIT SEE ROOF ASSEMBEY Gr CL FILL ALL VOIDS & DECK FLUTES WITH MINERAL WOOL FIRESTOPPING INSULATION. PROVIDE FIRESTOP WITHIN 1" GAB BETWEEN TOP OF GYPSUM AND U/S OF ROOF DECK (FIRESTOP SHOULD OVERLAP MEATL DECK AND GYPSUM BOARD 1" MIN RAIN WATER LEDER REFER MECHANICAL DWG. INSTALL R.W.L AT REAR SIDE OF STEEL COLUMN METAL STUD REFER TO SHOP DRAWINGS FOR FRAMING, FILL ALL VOIDS W/ BATT INSUL. DEMISING WALL MAINTAIN CONTINUITY OF 2 HOURS FRR. Gr DEMISING WALL MAINTAIN CONTINUITY OF 2 HOURS FRR. 1 1/2" 9 1/4" MAINTAIN CONTINUITY OF VAPOUR BARRIER AROUND COLUMN RETAIL UNIT 24 GA. GALV. METAL FLASHING ROOFING MEMBRANE TO EXTENT UP AND OVER CURB PRIOR TO INSULATION OF METAL FLASHING NOTE: REFER TO ARCHITECTURAL DWG'S. FOR SLEEPER LOCATIONS FOR ALL PRODUCT REFRIGERATION AND HVAC EQUIPMENT. CONTINUOUS L-SHAPE TRACK OR CHANNEL ANCHORED TO U/S OF TOP FLANGE AND TO BOTTOM FLANGE OF STEEL BEAM FOR GYPSUM BOARD ATTACHMENT (BOTH SIDES) 2"x 10" WOOD BLOC CURB CANT STRIP ROOF MATERIAL VARIES REFER TO ASSEMBLIES AND SPECIFICATION. FIRESTOPPING CAULKING BOTH SIDES OF WALL. DO NOT FILL W/ G.B. COMPOUND. DETAIL 'A' SLOTTED TOP TRACK SECURED TO STEEL BEAM, ALLOW FOR MINIMUM 1 1/2" VERTICAL MOVEMENT. FILL WITH MINERAL WOOL INSULATION INSULATION SEE SPEC. AND ARCHITECTURAL DWGS. CONTROL JOINT. FILL JOINT WITH FIRE RESISTANT CAULKING. BY SHELL CONTRACTOR Gr DRYWALL TO BE SCREWED TO BOTTOM TRACK. SAND AND SEAL TO MAKE SMOOTH NOTE: WHEN WALL RUNS PERPENDICULAR TO METAL DECK GYPSUM BOARD TO FOLLOW PROFILE OF FLUTE. LEAVE 1/2" GAP FOR DEFLECTION AND PROVIDE FLEXIBLE FIRE STOP MATERIAL. 1 1/2" VAPOUR BARRIER ROOF DECK 4 STEEL COLUMN SEE STRUCT. DWGS. FOR SIZE RAIN WATER LEDER REFER MECHANICAL DWG. INSTALL R.W.L AT REAR SIDE OF STEEL COLUMN METAL STUD REFER TO SHOP DRAWINGS FOR FRAMING, FILL ALL VOIDS W/ BATT INSUL. DEMISING WALL MAINTAIN CONTINUITY OF 2 HOURS FRR. Gr ULC W404 2 HOUR BLOCKING INSIDE FLUTES OF ROOF DECK AT SLEEPER LOCATIONS AND ADDITIONAL SUPPORT AS PER STRUCT. DWG'S. 7 1/2" GYPSUM BOARD ON METAL FURRING STUDS AS REQUIRED (BY TENANT) FIRE STOP DETAIL @ STUD WALL - 2 HOUR 1 1/2" = 1'-0" ROOF SLEEPER DETAIL 3" = 1'-0" DETAIL 'B' 2 CONTROL JOINT. FILL JOINT WITH FIRE RESISTANT CAULKING. BY SHELL CONTRACTOR RWL DETAIL @ COLUMN 1 1/2" = 1'-0" # SLOPE MIN DATE DESCRIPTION 2% NOTE: EXTERIOR WALL FINISH MAY VARY. REFER TO SECTIONS. 6" 2' - 8" 6" ± 1' - 4" SEE COLOUR SCHEDULE FOR VENT AND METAL SIDING PROJECT WESTWIND CENTRE SEAL 3 SIDE OF LOUVRED SCREEN DRAWING ± 1' - 4" INSECT SCREENING SCREWED TO WALL SPRUCEGROVE, ALBERTA 2' - 0" 1' - 0" 1'-0" X 2'-0" WALL OPENING BEYOND OPENING ± 1' - 0" PREFINISHED HEAVY GUAGE METAL CUT TO SHAPE. SCREW TO WALL THRU METAL SIDING. ± 4" PREFINISHED METAL FLASHING "RAIN GUARD" SCREWED TO WALL BEHIND SIDING AND TO PROJECT 1" FROM FACE OF SIDING TYPICAL DETAILS PROJECT NO. 14.178 1/2" EXTERIOR GRADE PLYWOOD 6" AROUND VENT OPENING 3" ± 6" PROJECT DATE ± 6" REFER TO MECH FOR FINAL HEIGHT REQUIRED 1' - 0 1/4" 2"x 10" NON-PRESSURE TREATED WOOD BLOCKING 2017-01-03 DRAWN BY LW CHECKED BY NA SCALE As indicated 5 PARAPET VENT DETAIL 1 1/2" = 1'-0" DRAWING NO. A7.1 BY CONTINUOUS METAL THRU-WALL FLASHING C/W AIR BARRIER REFER TO ELEVATION & WALL TYPES FOR EXTERIOR MATERIAL RUN SBS ROOF MEMBRANES UP WALL AS PER LOW PARAPET EPMD ROOF MEMBRANE 5/8" PLYWOOD TOP PLATE SLOPED TOWARDS ROOF & ANCHORED TO STRUCTURE CANAMOULD EXTERIOR CORNICE MOULDING. REFER TO ELEVATIONS FOR COLOUR 4" BLUESKIN TO GO UP AND OVER STEEL ANGLE LAP VAPOUR BARRIER 8" MIN. AS SHOWN. VAPOUR BARRIER TO TIE INTO BLUESKIN TRANSITIN MEMBRANE UNDER PARAPET 4" WALL FINISH VARIES REFER TO SECTIONS VARIES SEE SECTION G.B. TO EXTEND TO DECK & FOLLOW DECK PROFILE. CAULKING TO BE APPLIED AT ENDS SPRAY FOAM TO BE APPLIED TO DECK FLUTES PERPENDICULAR TO PARAPET AND ANY VOIDS BLUESKIN TRANSITION TO EXTEND TO OUTSIDE FACE OF PERIMETER STEEL ANGLE, CONTINUE UP & OVER AND EXTEND TO ROOF VAPOUR BARRIER VARIES VARIES LAP AIR BARRIER 4" MIN. AS SHOWN 4" TOP OF STEEL G.B. TO EXTEND TO DECK & FOLLOW DECK PROFILE. SPRAY FOAM IN DECK FLUTES. REFER TO GENERAL CONSTRUCTION NOTES #4, #27, 38 & 40. L-SHAPE TRACK OR STUD FOR G.B. ATTACHMENT FILL GAP BETWEEN STEEL AND DECK WITH FOAM INSULATION (TYPICAL) STEEL BEAM - SEE STRUCT. DWGS. FOR SIZE SEAL VAPOUR BARRIER TO METAL DECK 2ND LAYER OF GYPSUM BOARD FOR FIRE RATING WHERE REQUIRED. REFER TO OBC MATRIX. FILL ALL VOIDS W/ BATT INSULATION L-SHAPE TRACK OR CHANNEL FOR G.B. ATTACHMENT. ANCHORED TO BOTTOM FLANGE OF BEAM. 2" LONG LEGGED OUTER TOP TRACK MAINTAIN 3/4" GAP WALL PEEL & STICK MEMBRANE TO OVERLAP MOD. BIT. CAP SHEET MIN. 8" HORIZ. STRUCTURAL GIRT. SEE STRUCT. DWGS. BACK TO BACK GYPSUM BOARD L-SHAPE METAL TRIM C/W 1/2" CONTINUOUS CAULKING LAP AIR BARRIER 4" MIN. AS SHOWN APPLY ADDITIONAL 6" WIDE MIN. PEEL & STICK MEMBRANE OVER TOP EDGE OF DRIP FLASHING AND ONTO WALL PEEL & STICK MEMBRANE 1/2" SHEATHING REFER TO WALL TYPES AIR/MOISTURE BARRIER REFER TO WALL SCHEDULES 26 GA. PREFIN. METAL DRIP FLASHING TO ALIGN WITH LOW PARAPET CAP FALSHING DRIP PREFIN. METAL COUNTER FLASHING CAP SHEET WALL AIR BARRIER EXTEND TO TOP OF WALL SBS ROOF MEMBRANE EXTERIOR WALL SHEATHING REFER TO WALL TYPES This drawing, as an instrument of service, is provided by and is the property of Turner Fleisher Architects Inc. The contractor must verify and accept responsibility for all dimensions and conditions on site and must notify Turner Fleischer Architects Inc. of any variations from the supplied information. This drawing is not to be scaled. The architect is not responsible for the accuracy of survey, structural, mechanical, electrical, etc., information shown on this drawing. Refer to the appropriate consultant's drawings before proceeding with the work. Construction must conform to all applicable codes and requirements of authorities having jurisdiction. The contractor working from drawings not specifically marked 'For Construction' must assume full responsibility and bear costs for any corrections or damages resulting from his work. LAP AIR BARRIER 4" MIN. AS SHOWN SEE SECTION WALL ASSEMBLY VARIES REFER TO WALL SECTIONS AND SCHEDULES Gr CONTINUOUS 4" x 4" STEEL PERIMETER ANGLE. SEE STRUCTURAL DWGS. TOP OF STEEL MAINTAIN CONTINUITY OF AIR/MOISTURE BARRIERINSTALL CONTINUOUS AIR BARRIER OVER TOP OF WALL BEFORE INSTALLING WOOD BLOCKING-SEAL TO SHEATHING BOTH SIDES  Lesmill Road Toronto  Canada   Telephone() - turnerfleischer.com JOIST SHOE SEE SECTION 1' - 8" T/O PARAPET HEIGHT VARIES MODIFIED BIT. CAP SHEET-EXTEND UP PARAPET MIN. 6" ABOVE BASE FLASHING MEMBRANES & EXTEND DOWN ONTO ROOF MEMBRANE T URNER FLEISCHER ARCHITECTS INC. FILL CAVITY WITH BATT INSULATION UP TO 1'-0" ABOVE STEEL DECK OR TO U/S OF PARAPET IN COLDER CLIMATES. 1 1/2" CONTINUOUS PEEL & STICK MEMBRANE SEAL TO OUTSIDE FACE OF WOOD BLOCKING, RUN UP & OVER PARAPET AND EXTEND DOWN INSIDE FACE MIN. 6" TO SEAL OVERTOP OF WALL PEEL & STICK MEMBRANE 2"x2" WOOD BLOCKING NOTE: SEE EXTERIOR ELEVATIONS FOR LOCATION OF HORIZONTAL CONTROL JOINTS ON EIFS FINISH (LOCATED AT GROOVE LOCATIONS) (DECK) TOP OF ROOF MEMBRANE SEE BLOW-UP DETAIL BELOW. 26 GA. PREFOM. METAL COUNTERFLASHING C/W INTERLOCKING JOINTS UP AND UNDER SIDING & DRIP FLASHING 6" MIN. 3/4" EXTERIOR GRADE PLYWOOD SECURED TO METAL PLATE VARIES TOP OF CAP SHEET MAINTAIN MIN. DISTANCE TO SUIT LARGEST BEAM 24 GA. PREFINISHED METAL CAP FLASHING C/W INTERLOCKING JOINTS & STARTER STRIP WALL PEEL & STICK MEMBRANE PREFIN. METAL VERTICAL SIDING ON Z-BAR SUB-GIRTS 1 1/2" Sim Gr PRE-FINISHED ALUMINUM CAP FLASHING, FINISH TO MATCH CORNICE TURN ER FLEISC HER 1' - 6 3/8" 3 A11.2 Gr 3" LONG LEGGED INNER TOP TRACK DO NOT CONNECT TO TOP TRACK SLOTTED TOP TRACK SECURED TO STEEL BEAM, ALLOW FOR MINIMUM 1 1/2" VERTICAL MOVEMENT. 3/4 GAP IN SHEATHING, AND ON RIGID INSULATION AT STUCCO FINISH. SLOPE INSULATION TO EXTERIOR ANCHOR GYPSUM BOARD TO VERTICAL STUD SEAL AROUND ALL BRICK TIES & PENETRATIONS THROUGH AIR/MOISTURE BARRIER MAINTAIN CONTINUITY OF 6 MIL POLY VAPOUR AIR BARRIER PREFIN. METAL VERTICAL SIDING HORIZ. Z-BAR SUB-GIRT 2 SECTION DETAIL @ ROOF/SIDING 1 1/2" = 1'-0" 3 SECTION DETAIL @ SLIP CONNECTION 1 1/2" = 1'-0" PARAPET DETAIL 2 1 3" = 1'-0" Gr 1" Gr NOTE: REFER TO SECTION FOR WHERE FIRE-RATED WALL REQUIRED. 1/2" 3 1/2" 4" 4" NOTE: WALL CONSTRUCTION VARIES, REFER TO WALL SECTIONS AND SCHEDULES FOR APPLICABLE WALL TYPE. CONSTRUCTION AND APPLICATION METHOD APPLIES TO ALL SINGLE AND DOULBE STUD WALL SYSTEMS COMPOSITE PANEL EW-2.1 SEAL AROUND ALL BRICK TIES & PENETRATIONS THOUGH AIR/MOISTURE BARRIER AIR/MOISTURE BARRIER TO OVERLAP THROUGH WALL FLASHING PROVIDE WEEP HOLES C/W VENTILATORS AT 24" O.C. APPLY CONTRACTORS TAPE OVER JOINT OF AIR/MOISTURE BARRIER & THROUGH WALL FLASHING PRIME SHEATHING AND INSTALL AIR BARRIERTHRU WALL FLASHING UP WALL MIN. 8" TYPICAL 1/2" MASONRY OVERHANG CONTINUOUS FOAM GASKET PLATE OVERTOP OF CONT. AIR BARRIERDAMPROOFING CONTINUOUS THRU-WALL FLASHING CAULK VAPOUR BARRIER TO STEEL STUD & FOUNDATION WALL JOINT COMPOSITE EXTRUSION CAULKED ALUMINUM COMPOSITE PANEL/ CONCRETE PANEL SIDING REFER TO EXTERIOR FINISH SCHEDULE. STARTER TRACK METAL FLASHING ALUM FLASHING AIR BARRIER EXTEND ROOF MEMBRANE UP WALL AND LAP WITH AIR BARRIER PROVIDE STEEL PLATE TO SUPPORT BRICK WHERE REQUIRED. REFER TO STRUCTURAL DRAWINGS. DATE DESCRIPTION MASONRY BASE DETAIL 1 1/2" = 1'-0" LAP V/B AND AIR BARRIER CONT. SEALANT AROUND EXT. AND INT PERIMETER OF FRAME (TYP) WINDOW SUPPLIER TO PROVIDE CLIP CONNECTION AS REQUIRED. LENMAK METAL PANEL. REFER TO EXTERIOR FINISH SCHEDULE FOR COLOUR. WINDOW FRAMES CAULKING DETAIL @ CLOSET CANOPY 6 1 1/2" = 1'-0" # RWL HEAT TRACED. REFER TO MECH & ELECT STEEL STUD FRAMING & METAL FURRING ALUM FLASHING COLOUR TO MATCH STOREFRONT FOUNDATION INSULATION TO 48" BELOW FLOOR OR LOWER DEPENING ON DEPTH OF FROST. REFER TO SOILS REPORT. SECTION DETAIL @ ALUM. PANEL AND BRICK 4 1 1/2" = 1'-0" 5 CANOPY STEEL FRAMING REFER TO STR. DWGS. VAPOUR BARRIER TO EXTEND VERTIACALLY ABOVE CONC. SLAB AND SEALED TO FDN WALL. ASPHALT IMPREGNATED FIBERBOARD JOINT FILLER HSS SEE STRUCT DWGS 'C' CHANNEL 16" O.C. SEE STRUCT DWGS POURED CONC. FLOOR SLAB C/W REINFORCING. SEE STRUCT. DWGS. CONTINUOUS SEALANT HEAT TRACE RWL REFER TO MECHANICAL DWGS. LENMAK METAL PANEL. REFER TO EXTERIOR FINISH SCHEDULE FOR COLOUR. VARIES EW-1.1 1/2" GYP BAORD AROUND WINDOW OPENING VARIES Gr 6" WIDE AIR BARRIER SEALED TO WINDOW BACKSECTION 12" WIDE AIR BARRIER WRAPPED AROUND ROUGH OPENING PERIMETER SEAL V.B. W/ ACOUSTICAL CAULKING SHIM & LOW-EXPANDING SPRAY FOAM CAULKING PROJECT Gr WESTWIND CENTRE 1/2" MAT FACED MOULD & MOISTURE RESISTANT GYPSUM BOARD SILL & VERTICAL AT WINDOW LOCATIONS ONLY CAULKING C/W FOAM ROPE. PROVIDE DRAIN HOLES AT EACH LOCATION OF DRAIN HOLES IN WINDOW FRAME 1'-6" WIDE AIR BARRIERTHRU WALL FLASHING PROVIDE WEEP HOLES C/W VENTILATORS AT 24" O.C. 3 5/8"1 1/2"3 5/8" 4" 4" 1/2" STEEL COLUMN/BASE PLATE ON TOP OF FOUNDATION WALL(SEE STRUCT. DWGS.) CONTINUOUS SEALANT ASPHALT IMPREGNATED FIBERBOARD JOINT FILLER 0'-0" CONTINUOUS FOAM GASKET PLATE OVERTOP OF CONTINUOUS PEEL & STICK TYPICAL 1/2" MASONARY OVERHANG TOP OF FIN. FLOOR CONCRETE CURB STOREFRONT DOOR 1/2" ASPHALT IMPREGANTED FIBERBOARD JOINT FILLER @ CONTROL JOINT. 6"CONCRETE SLOPE STRUCTURAL STOOP 1/2" JOINT FILLER DAMPROOFING MEMBRANE CAULK VAPOUR BARRIER TO FDN WALL 10Mx2'-0" LONG REBAR DOWELS @ 1'-4" O.C. REFER TO STRUCT. SPRUCEGROVE, ALBERTA DRAWING TYPICAL DETAILS 2' - 0" ROOF MEMBRANE FULLY ADHERED, EXTEND ROOF MEMBRANE UP WALL AND LAP WITH AIR BARRIER LOW PROFILE ROOF DRAIN, REFER TO MECHANICAL DWGS. WOOD BLOCKING TO SUITE 6"CONCRETE GRADE BEAM REFER TO STRUCTURAL DWGS. CONCRETE FLOOR SLAB ON GRANULAR BASE SEE STRUCT. 2 LAYERS OF 2" HIGH DENSITY INSULATION. EDGES STAGGERED 2" RIGID INSULATION TO 48" BELOW GRADE (TYP) PROJECT NO. 14.178 PROJECT DATE 2017-01-03 CONCRETE GRADE BEAM/ CONCRETE PEIER & PILE REFER TO STRUCTURAL DWGS. DRAWN BY Author CHECKED BY Checker FLOOR FINISH & BASEBOARD BY TENANT SCALE As indicated 7 WINDOW/ MASONARY DETAIL W/ SILL 1 1/2" = 1'-0" 8 FROST SLAB SECTION 1/2" = 1'-0" DRAWING NO. A7.2 BY A 9" 1/2" 2 1/2" CORNER WALL CONSTRUCTION (AT GLAZING-MID HEIGHT): -1/4" ALUM. FRAME/COVER PANEL (COLOUR AND FINISH TO MATCH WINDOW FRAMES) 1-1/2" RIGID INSULATION -TYVEK AIR BARRIER -1/2" FIBERGLASS MAT FACED G.B. (FIRE RATED G.B. WHERE REQUIRED) -VAPOUR BARRIER -1/2" GYPSUM BOARD STRUCT. MEMBER . REFER TO STRUCTURAL AIR BARRIER TURN ER FLEISC HER ATTACH AIR BARRIER TO WINODW FRAME AND AIR/V.B. TO PEEL & STICK  Lesmill Road Toronto  Canada   Telephone() - turnerfleischer.com NOTE: PROVIDE WALL FURRING FROM U/S OF CANOPY TO U/S OF DECK TO CONCEAL PIPE ROUTING (REFER TO FLOOR PLAN) CLEAR ANODIZED ALUMINUM PANEL TO MATCH WINDOW FRAMES. FILL CAVITY W/RIGID INSULATION. STEEL COLUMN SEE STRUCT. DWGS. FOR SIZE Gr CONTINUOUS FOAM GASKET PLATE OVERTOP OF CONTINUOUS AIR BARRIERDAMPPROOFING RAIN WATER LEDER REFER MECHANICAL DWG. INSTALL R.W.L AT REAR SIDE OF STEEL COLUMN Gr METAL STUD REFER TO SHOP DRAWINGS FOR FRAMING, FILL ALL VOIDS W/ BATT INSUL. DEMISING WALL MAINTAIN CONTINUITY OF 2 HOURS FRR. N/A VAPOUR BARRIER PROVIDE FIRE STOP AT JOINTS DEMISING WALL MAINTAIN CONTINUITY OF 2 HOURS FRR. This drawing, as an instrument of service, is provided by and is the property of Turner Fleisher Architects Inc. The contractor must verify and accept responsibility for all dimensions and conditions on site and must notify Turner Fleischer Architects Inc. of any variations from the supplied information. This drawing is not to be scaled. The architect is not responsible for the accuracy of survey, structural, mechanical, electrical, etc., information shown on this drawing. Refer to the appropriate consultant's drawings before proceeding with the work. Construction must conform to all applicable codes and requirements of authorities having jurisdiction. The contractor working from drawings not specifically marked 'For Construction' must assume full responsibility and bear costs for any corrections or damages resulting from his work. PROVIDE FIRE STOP AT JOINTS CAULKING CAULKING RETURN GYPSUM BOARD INTO WINDOW FRAME EXTEND G.B. TO CREATE FIRESTOP PROTECTION SEE FLOOR PLAN FOR ROUGH OPENING SIZE SPRAY FOAM GAPS 1/2" PLYWOOD AIR BARRIER OVER 1/2" PLYWOOD VAPOUR BARRIER TYPICAL GLAZING: -REFER TO SPECIFICATIONS FOR GLAZING 1 CONC. BLOCK PROVIDE RUBBERIZED GASKET AROUND COLUMN TO PREVENT THERMAL BRIDGING. 3 FILL CAVITY W/MINERAL WOOL FIRESTOPPING INSULATION T URNER FLEISCHER ARCHITECTS INC. SEE FLOOR PLAN FOR ROUGH OPENING SIZE 1/2" AIR BARRIER REFER TO WALL TYPES FOR 6" GLAZING/FRAME 1" 1 1/2" 3 1/2" EXTERIOR SHEATING Gr COLUMN @ GLAZING CORNER DETAIL 1 3" = 1'-0" MAINTAIN CONTINUITY OF VAPOUR BARRIER AROUND COLUMN SHIM & SPRAY FOAM INSULATION PAINTED GYPSUM BOARD SILL 2 1/2" 2 Gr 7 1/2" COLUMN @ GLAZING W/ RWL DETAIL 1 1/2" = 1'-0" 4 FIRE RATED CONCRETE WALL @ EXTERIOR MASONRY WALL 2 1 1/2" = 1'-0" Gr AIR BARRIER EXTERIOR SHEATHING EW-1.1 FILL CAVITY W/MINERAL WOOL FIRESTOPPING INSULATION 1" 3 1/2" ROOF HATCH NOT TO HAVE A LATCH ON THE EXTERIOR RAILING. REFER TO ROOF PLAN FOR EXTENTS P2 NOTE: VAPOUR BARRIER 8" Gr PROVIDE FIRE STOP AT JOINTS 1/2" 1/2" REFER TO STRUCUTRAL DWGS FOR COLUMN LOCAITON & SIZE MULLION (THROAT REMOVED) BACKING SUPPORT FOR INSULATED. SPANDREL PANEL 3'-0"x2'-6" ROOF HATCH TO BE BILCO TYPE "S" 14 GA. COVER, HINGES & HASP FOR PADLOCK SEE ROOF PLAN FOR LOCATION LADDER TO COMFORM TO OBC SUPPLEMENTARY STANDARD SB-8. LADDER TO BE SELF SUPPORTING. FILL CAVITY W/MINERAL WOOL FIRESTOPPING INSULATION 2' - 6" PROVIDE 6" MIN. CLEARANCE BETWEEN THE RUNGS AND THE ADJACENT WALL OR ROOF FRAMING/ OPENING. REFER TO OBC SB-8 & MINISTRY OF LABOUR DATA SHEET 2-04. PROVIDE FIRE STOP AT JOINTS PROVIDE FIRE STOP AT JOINTS PREFINISHED GALVANIZED METAL FLASHING SET IN SEAL/FASTENANT 3' - 0" INSULATED CURB W/ PRE-FIN. MTL. FLASHING ON INSIDE FACE & INTEGRAL CAP 6" MIN. EXTEND VAPOUR BARRIER UP AND ADHERE TO CURB PROVIDE FIRE STOP AT JOINTS FILL CAVITY W/MINERAL WOOL FIRESTOPPING INSULATION Gr T/O STEEL VARIES 3"x3"x1/4" STL. ANGLE, REFER TO STRUCUTRAL DWGS FOR COLUMN LOCAITON P2 PROVIDE SOLID BLOCKING IN FLUTES SECURE TO OPENING FRAMING AND LADDER 1' - 6" INSULATED SPANDREL GLAZING PANEL 5 FIRE RATED DEMISING WALL @ EXTERIOR MASONRY WALL 1 1/2" = 1'-0" 2 1/2" 1" DIA. SOLID STL BAR RUNGS AT 12" O.C. W/ NON-SLIP SURFACE ON TOP SIDE CLEAR GLAZING SILICONE PROVIDE SLIP JOINT AT TOP OF ROOF DECK TO ALLOW FOR MOVEMENT INTERMEDIATE HOOPS VERTICAL FLAT BARS EQ 3' - 4" INSULATED BACK PAN 6 SECURE CAGE TO LADDER AS REQ'D. FIRE RATED DEMISING WALL @ SPANDREL PANEL 1 1/2" = 1'-0" 2 1 # 17/02/22 17/02/07 DATE ISSUED FOR TENDER ISSUED FOR REVIEW DESCRIPTION FACE OF WALL PREFINISHED METAL FLASHING, C/W COUNTER FLASHING ON WATER PROOFING MEMBRANE METAL CAP SHEET FLASHING RIGID INSULATION 3/4" FIRE RATED PLYWOOD STEEL LADDER: 1" DIA. BAR RUNGS @ 12" O.C. ON C4x5.4 CHANNEL RAILS BOTH SIDES c/w BRACKETS AT TOP AND BOTTOM & @ 6'-0" O.C. MAX. SECURE BRACKETS WITH 1/2" ANCHORS min. TO SUIT WALL ASSEMBLY. GRIND SMOOTH ALL WELDS. FOR HEIGHT OF LADDER SEE WALL SECTIONS. PRIME AND PAINT (LADDER DESIGNED TO BE SELF SUPPORTING WITHOUT WALL ATTACHMENTS) VARIES EQ Gr WOOD BLOCKING FASTENED TO PLYWOOD 2' - 2" LADDER & SAFETY CAGE TO BE PRIMED & PAINTED YELLOW PROVIDE WOOD BLOCKING AS REQUIRED SECURED IN STEEL STUD WALL FOR SUPPORT T/O PARAPET VARIES O.W.S.J. (CLEAR) 4"X4"X3/8" STL ANGLE 2 1/2" (CLEAR) BOTTOM HOOP ROOF ACCESS PROFILE (ABOVE) PREFINISHED VERTICAL METAL SIDING C/W Z-GIRTS 3 1/8" 8" 3' - 0" 2' - 7" ROOF MATERIAL VARIES REFER TO ASSEMBLIES AND SPECIFICATION. 1/4" x 3" PERIMETER STEEL PLATE FRAME WITH BURGLAR BARS. REMOVED WHEN USED FOR KITCHEN EXHAUST 8" 2' - 6" 1' - 4" FOR WALL TYPE WALL REFER TO PLAN SPRUCEGROVE, ALBERTA DRAWING 1" Dia. MTL. RUNGS @1'-0" O.C. (TYP.) METAL FLASHING TYPICAL DETAILS ROOF HATCH PLAN FILL WITH BATT INSULATION 1'-0" MIN ABOVE STEEL DECK ANCHOR TO CONCRETE FLOOR WITH MINIMUM 2" LONG x1/2" DIA. A/B F-1 F.F.E VARIES SEE STRUCTURAL DRAWINGS FOR ANGLE SIZE AND LOCATION PROJECT NO. 14.178 PROJECT DATE 2017-01-03 DRAWN BY LW T/O STEEL 5/8" DIA. AT 12" 7 ROOF MEMBRANE ON BACK OF PARAPET. EXTEND TO CORNICE OVERHANG MAX. 7' - 0" x NOTE: SEE STRUCTURAL DRAWINGS FOR ANGLE SIZE AND LOCATION NOTE: USE 1/2" PLYWOOD AND BLUE SKIN ENCLOSE ALL PARAPET STEEL BRACING, C/W METAL FLASHING WITH DRIPS 1' - 0" x WESTWIND CENTRE 3' - 0" VARIES 4' - 9" LAP SEALANT 1' - 7 1/4" 11 7/8" FOLLOW MANUFACTURER DETAILS FOR LAP SPLICES, AS TO MAINTAIN WARRANTY. ALSO REFER TO MECH FOR FINAL HEIGHT REQUIRED PROJECT HVAC CURB BY RTU MANUFACTURER, SLOPE BOTTOM OF CURB TO MATCH ROOF SLOPE, TOP OF CURB TO BE LEVEL CHECKED BY ROOF LADDER SECTIOIN 9 1/2" = 1'-0" ROOF CURB 1 1/2" = 1'-0" NA SCALE As indicated 8 PARAPET RETURN DETAIL 1" = 1'-0" DRAWING NO. A7.3 LW LW BY TURN ER FLEISC HER DOOR & FRAME SCHEDULE T URNER FLEISCHER ARCHITECTS INC. Door Numbe r D01 D02 D03 D04 D05 D06 D07 D08 D09 D10 D11 D12 D13 D14 D15 Location UNIT N.1 ENTRANCE UNIT N.2 ENTRANCE UNIT N.3 ENTRANCE UNIT N.4 ENTRANCE UNIT N.5 ENTRANCE UNIT N.6 ENTRANCE UNIT N.7 ENTRANCE UNIT N.7 EXIT UNIT N.6 EXIT UNIT N.5 EXIT UNIT N.4 EXIT UNIT N.3 EXIT MECH/ELE DOOR UNIT N.2 EXIT UNIT N.1 EXIT Door Type 2-A A A A A A A B B B B B B B B Door Width 6'-4" 3'-2" 3'-2" 3'-2" 3'-2" 3'-2" 3'-2" 3'-2" 3'-2" 3'-2" 3'-2" 3'-2" 3'-2" 3'-2" 3'-2" Door Height 7'-0" 7'-0" 7'-0" 7'-0" 7'-0" 7'-0" 7'-0" 7'-0" 7'-0" 7'-0" 7'-0" 7'-0" 7'-0" 7'-0" 7'-0" Thickness 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" 1 3/4" Frame Material ALUMINUM ALUMINUM ALUMINUM ALUMINUM ALUMINUM ALUMINUM ALUMINUM INSULATED HOLLOW METAL INSULATED HOLLOW METAL INSULATED HOLLOW METAL INSULATED HOLLOW METAL INSULATED HOLLOW METAL INSULATED HOLLOW METAL INSULATED HOLLOW METAL INSULATED HOLLOW METAL DOOR DOOR DOOR WIDTH WIDTH WIDTH Finish CLEAR ANODIZED CLEAR ANODIZED CLEAR ANODIZED CLEAR ANODIZED CLEAR ANODIZED CLEAR ANODIZED CLEAR ANODIZED PAINT PAINT PAINT PAINT PAINT PAINT PAINT PAINT Fire Rating N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Hardware 1,6,7,10,11,13,14,18,23 1,6,7,10,11,13,14,18,23 1,6,7,10,11,13,14,18,23 1,6,7,10,11,13,14,18,23 1,6,7,10,11,13,14,18,23 1,6,7,10,11,13,14,18,23 1,6,7,10,11,13,14,18,23 5,6,8,10,11,18,23 5,6,8,10,11,18,23 5,6,8,10,11,18,23 5,6,8,10,11,18,23 5,6,8,10,11,18,23 2,6,8,10,11,18,23,25, 26 5,6,8,10,11,18,23 5,6,8,10,11,18,23 DOOR HEIGHT TYPE 'A' CLEAR ANODIZED ALUMINUM DOOR c/w TEMPERED GLAZING TYPE '2-A' CLEAR ANODIZED ALUMINUM DOUBLE ENTRANCE DOORS c/w TEMPERED GLAZING TYPE 'B' EXTERIOR INSULATED HOLLOW METAL DOOR c/w INSULATED THERMALLY BROKEN HOLLOW METAL FRAME Finish CLEAR ANODIZED CLEAR ANODIZED CLEAR ANODIZED CLEAR ANODIZED CLEAR ANODIZED CLEAR ANODIZED CLEAR ANODIZED PAINT PAINT PAINT PAINT PAINT PAINT PAINT PAINT 1 2 3 4 5 6 7 8 9 10 11 12 13 DESCRIPTION FLUSH BOLTS, TOP AND BOTTOM LOCKSET - KEYED EXT./THUMBTURN INT. PASSAGE SET (H.C. REQ.TS. FOR W.C. LATCH SET PANIC HARDWARE - EXITING DEVICE "BAR" CLOSER - SURFACE MOUNTED, HEAVY DUTY PUSH / PULL KICK PLATE - INSIDE FACE OF DOOR PICTOGRAM W/R WIGN THRESHOLD WEATHER STRIPPING ELECTRIC OPERATOR (BY TENANTS) DOOR OPERATOR ITEM NO. 14 15 16 17 18 19 20 21 22 23 24 25 26 DOOR TYPES 1/2" = 1'-0" Comments N/A 1 1x GREY HATCH DENOTES SPANDREL GLAZING 2 CLEAR LOW E GLAZING This drawing, as an instrument of service, is provided by and is the property of Turner Fleisher Architects Inc. The contractor must verify and accept responsibility for all dimensions and conditions on site and must notify Turner Fleischer Architects Inc. of any variations from the supplied information. This drawing is not to be scaled. The architect is not responsible for the accuracy of survey, structural, mechanical, electrical, etc., information shown on this drawing. Refer to the appropriate consultant's drawings before proceeding with the work. Construction must conform to all applicable codes and requirements of authorities having jurisdiction. The contractor working from drawings not specifically marked 'For Construction' must assume full responsibility and bear costs for any corrections or damages resulting from his work. BLANK EXTERIOR FACE BLANK EXTERIOR FACE BLANK EXTERIOR FACE BLANK EXTERIOR FACE BLANK EXTERIOR FACE BLANK EXTERIOR FACE BLANK EXTERIOR FACE DESCRIPTION KEYED THUMBTURN THUMBTURN ONLY AS SUPPLIED BY MFR. DETEX ALARM DOOR SWEEP DOCK SEAL MOTORIZED OPERATION PEEP HOLE H.C. OPENER HEAVY DUTY BUTT HINGES EXIT DEVICE, C/W NON-LOCKING LATCH KEYED CYLINDER DOOR PULL w/ PRY PLATE WELDED: WRAP AROUND FRAME (TYPICAL) REFER TO SPECS. WELDED: WRAP AROUND FRAME (TYPICAL) REFER TO SPECS. CORNER BEAD TYPE 1: REINFORCE JAMB WITH WOOD BLOCKING 2 1 # TYPE 2: 17/02/22 17/02/07 DATE ISSUED FOR TENDER ISSUED FOR REVIEW DESCRIPTION TYPE 3: 37' - 5" EQ EQ EQ EQ EQ EQ EQ EQ WELDED: WRAP AROUND FRAME (TYPICAL) REFER TO SPECS. 9 1/4" ALUMINUM FRAMING ALUMINUM FRAME PROJECT DOUBLE GLAZED WINDOW 3' - 8" 1 5/8" TYPE 4: 1 1/2 HOUR FIRE RATED T/O GLAZING 10' - 0" TYPE 5: WESTWIND CENTRE TYPE 6: 3' - 0" SPRUCEGROVE, ALBERTA DRAWING BENT STEEL PLATE DOOR SCHEDULE N/A 7' - 0" 6' - 4" 13' - 0" 13' - 8" PROJECT NO. 14.178 PROJECT DATE 2017-01-03 DOUBLE STUD JAMB PRESSED AND INSULATED STEEL FRAME 8" FFE (647.35) 0" 8" 1 EQ Material ALUMINUM ALUMINUM ALUMINUM ALUMINUM ALUMINUM ALUMINUM ALUMINUM HOLLOW METAL HOLLOW METAL HOLLOW METAL HOLLOW METAL HOLLOW METAL HOLLOW METAL HOLLOW METAL HOLLOW METAL HARDWARE SCHEDULE ITEM NO. EQ  Lesmill Road Toronto  Canada   Telephone() - turnerfleischer.com 10' - 11" 6' - 4" 20' - 2" DRAWN BY LW CHECKED BY CLIP-IN STUD ANCHOR NA SCALE 4 SOUTH WINDOW ELEVATION 1-2 1/4" = 1'-0" TYPE 7: 2 DOOR FRAME TYPES 12" = 1'-0" TYPE 8: As indicated DRAWING NO. A8.1 LW LW BY 4 5 GREY HATCH DENOTES SPANDREL GLAZING CLEAR LOW E GLAZING 6 6 7 8 GREY HATCH DENOTES SPANDREL GLAZING CLEAR LOW E GLAZING CLEAR LOW E GLAZING TURN ER FLEISC HER T URNER FLEISCHER ARCHITECTS INC. 1' - 5 7/8" 18' - 0 1/8" 1' - 5 7/8" 3' - 7 1/4" 3' - 7 1/4" 3' - 7 3/4" 1' - 0" 3' - 6 3/4" 18' - 9 1/8" 3' - 7 1/4" 3' - 9" 6" 3' - 9" 3' - 9 1/2" 9 1/8" 8 7/8" 3' - 8 1/2" 3' - 9" 9 1/8" 8 7/8" 6" EQ EQ EQ EQ 6"6" EQ EQ EQ EQ EQ 1 1/4" 3' - 0" This drawing, as an instrument of service, is provided by and is the property of Turner Fleisher Architects Inc. The contractor must verify and accept responsibility for all dimensions and conditions on site and must notify Turner Fleischer Architects Inc. of any variations from the supplied information. This drawing is not to be scaled. The architect is not responsible for the accuracy of survey, structural, mechanical, electrical, etc., information shown on this drawing. Refer to the appropriate consultant's drawings before proceeding with the work. Construction must conform to all applicable codes and requirements of authorities having jurisdiction. The contractor working from drawings not specifically marked 'For Construction' must assume full responsibility and bear costs for any corrections or damages resulting from his work. 9 1/8" 7' - 8 1/8" 3' - 2" 7' - 1 7/8" 6"6" 8' - 1 1/2" 3' - 2" 7' - 0" 8" 8" 7' - 0" 6' - 4" 10' - 0" 7' - 0" 7' - 0" 8" Level(647.35) FFE 14 0" 1' - 5 7/8"  Lesmill Road Toronto  Canada   Telephone() - turnerfleischer.com 1 1/4" 18' - 7 3/4" 9' - 4" 3' - 0" 6' - 4" 9' - 4" 8" 10' - 0" EQ 1' - 0" T/O GLAZING 10' - 0" T/O GLAZING 10' - 0" FFE (647.35) 0" 18' - 8 7/8" 8' - 1 1/2" 3' - 2" 7' - 11 1/2" 8' - 8 1/8" 3' - 2" 7' - 4 7/8" 8 7/8" 7' - 5 1/2" CLEAR LOW E GLAZING 2 SOUTH WINDOW ELEVATION 4-6 1 1/4" = 1'-0" 2 2x 3 8 3/4" 18' - 9 1/4" 8 3/4" 3' - 9" 3' - 9" 3' - 9 1/2" 1' - 0" 3' - 8 1/2" 3' - 9" 6"6" D C 4 GREY HATCH DENOTES SPANDREL GLAZING CLEAR LOW E GLAZING SOUTH WINDOW ELEVATION 6-8 1/4" = 1'-0" CLEAR LOW E GLAZING CLEAR LOW E GLAZING 17' - 11 7/8" 3' - 7 1/8" 3' - 7 1/8" 3' - 7 5/8" 1' - 6 1/8" 3' - 6 5/8" 18' - 9" 3' - 7 1/8" 1' - 6 1/8" EQ EQ EQ EQ 9" 8' - 3 5/8" 3' - 0" 7' - 11 5/8" 8' - 4" 3' - 0" SOUTH WINDOW ELEVATION 2-4 1/4" = 1'-0" 7' - 1 7/8" 1' - 6 1/8" 4 8" 6' - 4" 9' - 4" 3' - 0" 8 3/4" 8" 7' - 0" FFE (647.35) 0" 8" 7' - 0" 6' - 4" 10' - 0" 9' - 4" 8" 10' - 0" EAST WINDOW ELEVATION 1/4" = 1'-0" CLEAR LOW E GLAZING GREY HATCH DENOTES SPANDREL GLAZING Bx C D # 5' - 3" EQ DESCRIPTION 1 3/4" 14' - 2 3/4" EQ DATE EQ 3' - 8" 5' - 3" T/O GLAZING 10' - 0" PROJECT 3' - 0" 13' - 0" WESTWIND CENTRE 13' - 8" SPRUCEGROVE, ALBERTA FFE (647.35) 0" 8" 6' - 4" DRAWING 8" 3 EQ 9" T/O GLAZING 10' - 0" 3' - 0" T/O GLAZING 10' - 0" FFE (647.35) 0" Bx GLAZING SCHEDULE PROJECT NO. 14.178 PROJECT DATE 2017-01-03 5 WEST WINDOW ELEVATION 1/4" = 1'-0" DRAWN BY LW CHECKED BY NA SCALE 1/4" = 1'-0" DRAWING NO. A8.2 BY