Preview only show first 10 pages with watermark. For full document please download

Wire Identification Numbers For Bard Use Only.

   EMBED


Share

Transcript

3 CO2 Controller Part #8403-067 2 BLACK/WHITE 39 ORANGE GREEN 6 PIN CO2 PLUG 27 38 RED/WHITE 54 R 240V 208V 6 BLACK/WHITE 55 Purple/White W1/E Red/Yellow Y2 Purple Y2 D/YO A G Orange Y1 Yellow 1 O/B Blue 2 3 4 5 6 7 8 9 10 11 12 W2 Brown Purple A Brown/White G Orange Y1 Yellow O/B Blue W2 Brown R Red/White C Black/White L Pink 1 Red/Yellow W1/E PLUG #2 R Red/White C Black/White L Pink Analog Out 4115-100 A PLUG #2 1 2 3 4 5 6 7 8 9 10 11 12 Temp. and Humidity Controller Part #8403-060 CO2 Controller Part #8403-067 24VAC "D" THERMOSTAT OPTION 230/208-60-1 VOLT PACKAGE UNIT DIAGRAM 1 Red 2 Black 3 Yellow 4 Brown 5 Orange 6 Green Red Black Yellow Brown Orange Green "H" THERMOSTAT OPTION PLUG #1 1 2 3 4 5 6 4115-101 C FOR 208 VOLT OPERATION, MOVE THIS RED WIRE TO 208 VOLT TRANSFORMER TAP 3 REMOVE JUMPER WHEN CS2000 ENERGY MONITOR IS INSTALLED 4 REMOVE WIRE FROM TERMINAL Y2 AND TAPE OFF WHEN LOWER FULL LOAD CFM DESIRED RED GREEN BLACK/WHITE PINK RED/WHITE BROWN/WHITE BROWN BLACK RED BLACK CC ALR R C Y 1 LPC LPC 39 4 5 3 2 1 BLACK/ WHITE 39 35 21 Capacitor 2 35 36 36 33 BLACK/WHITE 27 18 Check Light 12 11 10 9 8 7 6 5 4 3 12 PIN VENT PLUG 2 1 1 High Speed Solenoid 27 BLUE BLACK/WHITE BLUE PURPLE BLACK/WHITE 48 27 1 BLUE/WHITE BLUE/BLACK YELLOW Reversing Valve R RED 53 S Three way Valve CAPACITOR CHART MODEL CAPACITOR QW2S 35/370 QW3S 40/370 QW4S 45/370 QW5S 80/370 ! 2 3 OPTIONAL 3 PIN PLUG FOR ERV 27 FOR ANTIFREEZE LOOP APPLICATIONS, CHANGE LOW PRESSURE SWITCH TO YELLOW LEADS ON YELLOW WIRES COMING OFF OF COMPRESSOR CONTROL MODULE "LPC" TERMINALS 2 HPC 38 BLACK/WHITE Purple/White D/YO Temp. and Humidity Controller Part #8403-060 4115-102 C Compressor 24 Control Module COM Transformer 39 Purple/White T2 37 YELLOW/RED 19 30 32 C L2 T1 48 31 RED 15 "X" THERMOSTAT OPTION RED/ WHITE 38 27 BROWN 5 D BLUE 53 YELLOW 33 LOW VOLTAGE STRIP RED/ WHITE BLUE/BLACK L1 12 10 38 RED/WHITE 6 4 GRAY PURPLE RED/WHITE YELLOW ORANGE 9 B 5 Red Black Yellow Brown Orange Green 4 4115-105 A 6 7 A RED/WHITE 1 3 Analog Out 53 27 10 3 "K" THERMOSTAT OPTION 10 34 56 3 4 BLUE/BLACK Terminal Strip 2 24VAC RED/WHITE BLACK/WHITE PINK PINK 34 YELLOW D/YO DEHUM RELAY 1 10 YELLOW Pink 14 BROWN RED/WHITE 10 BLUE L L Black/White 10 BLUE C YELLOW 10 PURPLE YELLOW Green C BLUE BROWN BLUE YELLOW BLUE RED Orange 6 PLUG #1 1 2 3 4 5 6 10 10 RED 5 ORANGE YELLOW YELLOW Ground Terminal 4 57 10 YELLOW Brown Red/White BROWN/WHITE 5 Circuit Breaker RED 4 R 50 Brown RED Yellow W2 R 29 RED/YELLOW 1 Black 3 Brown W2 BROWN/WHITE 9 10 11 12 2 Blue 8 Analog Out Red Black Yellow Brown Orange Green Red O 7 24VAC 1 O/B 28 RED/YELLOW PURPLE PURPLE Compressor Contactor Pink Yellow 4 55 YELLOW L CO2 Controller Part #8403-067 Y1 L1 L2 BLACK Black/White ORANGE 54 BLACK C Y1 5 PIN PLUG FOR INDOOR BLOWER MOTOR 5 BROWN/WHITE RED Red/White 10 53 GREEN R 10 PURPLE/WHITE 4 PINK Brown 12 PIN PLUG FOR THERMOSTAT 10 RED/WHITE W2 Orange 1 G 2 3 4 5 6 7 8 9 10 11 12 3 10 YELLOW Blue Brown/White 1 5 6 O A G A PLUG #2 4 Yellow 3 Orange 52 51 2 Brown/White Purple 1 A G Y1 Red/Yellow Y2 BROWN/WHITE Purple E Y2 PURPLE Y2 W1/E BROWN Red/Yellow BLACK/WHITE 1 E BLACK/WHITE BLACK/WHITE Low Voltage Terminal Strip Low Voltage Terminal Strip Terminal Block #1 ("A" Ctrl. Opt. Only) 208/230-60-1 POWER SOURCE 11 O1 Y Y1 C 9 13 2 YELLOW 2 YELLOW Temp. and Humidity Controller Part #8403-060 BLACK FREEZE THRMOSTAT 1 10 6 YELLOW BLACK DEHUM. CONTROL 49 14 12 15 3 BLACK/WHITE 16 PIN PLUG FOR INDOOR BLOWER MOTOR 10 DANGER *ELECTRICAL SHOCK HAZARD *DISCONNECT POWER BEFORE SERVICING. C BLACK Hi Pressure Control Low Pressure Control Low Pressure Control Compressor 4113-101 B 99 Wire Identification numbers for Bard use only. ! WARNING USE COPPER CONDUCTORS ONLY SUITABLE FOR AT LEAST 75° C. Factory Field Optional High Voltage Low Voltage COMPOSITE WIRING DIAGRAM 230/208-60-1 Bard Mfg. Co. Bryan, Ohio 4113C101 C