Transcript
WIRELESS DATA TRANSFER SYSTEM APPLICABLE FOR OTHER BRANDS
Code
Description
7306-1
receiver (with USB cable)
7306-20
transmitter module
digital calipers and digital depth gages
7306-30
transmitter module
digital micrometers (except 3108 and 3109)
Applicable products
receiver 7306-1
digital indicators 7306-40
transmitter module digital protractor
transmitter 7306-20 CONNECTION: one receiver can be connected to multi transmitters.
receiver (7306-1)
transmitter (7306-40)
USB port
DATA COLLECTION: 1) Single collection: press the read button once to collect the reading from measuring tool once. 2) Multi collection: press the read button once to start collecting readings from measuring tools continuously, press the button again to stop collecting. Total collection times and interval time can be adjustable.
read button
maximum transmission distance 100m transmitter (7306-20) transmitter (7306-30)
measuring tools code A, B, C
DISPLAY: data can be input to Excel as keyboard signal.
1
1
All data are displayed in the same column. Each measuring tool can be coded such as A, B, C, etc.
DATA OUTPUT CABLE 7302-SPC1A
7302-SPC1B
7302-SPC2A
7302-SPC3A
7302-SPC4
Connect to USB port of computer Without software, data can be input as keyboard signal to Excel, Word, etc. Press the red button or foot switch (optional) to input data
Excel
red button
USB port
foot switch is optional
7304-2
Code
Description
Remark
7302-SPC1A
cable (length 2.5m)
for digital calipers and digital depth gages
7302-SPC1B
cable (length 2.5m)
for digital calipers and digital depth gages
7302-SPC2A
cable (length 2.5m)
for digital micrometers
7302-SPC3A
cable (length 2.5m)
for digital indicators
7302-SPC4
cable (length 2.5m)
for digital calipers 1103 series
7304-2 型号
foot switch with cable (length 1.5m)
digital protractor
optional
1
2
RS232 DATA OUTPUT CABLE
USB power port
7305-SPC1A
automatic judgment by setting tolerance
7305-SPC3
test result display (maximum value, minimum value, total quantity of workpiece, quantity of passed and not passed, quantity of exceed upper tolerance and exceed lower tolerance)
foot switch (optional) 7304-2
red button
RS232 port
foot switch is optional manual sampling
automatic sampling
set auto sample interval and tolerance Signal
Manual sampling and automatic sampling Press manual sampling button in software or red button on cable or foot switch once to collect the reading from measuring tool once Can be used in Windows Hyperterminal Supplied with software Voltage required: 5-10V Cable length 2.5m Optional accessory: foot switch (code 7304-2, cable length 1.5m)
digital indicators
7305-SPC1A
3
7305-SPC2
digital calipers and digital depth gages
7305-SPC3
digital micrometers
1
2
DATA
3
4
5
VDD
GND
Applicable products
Code
7304-2
1
foot switch with cable (length 1.5m)
digital protractor