Preview only show first 10 pages with watermark. For full document please download

Wireless Transmitter-receiver System

   EMBED


Share

Transcript

WIRELESS TRANSMITTER-RECEIVER SYSTEM RTD, THERMOCOUPLE, %RH ZGU201 utility for display transmitter date & to process same for data logging or chart display ZGB201 USB powered receiver which receive date from transmitter ZGE201 RTD input transmitter ZGE203 Humidity transmitter ZGE202 REPEATER-enhances the received signal by increasing its strength and re-sends it. Headmount enclosure type transmitter for RTD and Thermocouple ZGE202 thermocouple transmitter FEATURES Transmitter (Surface and Head Designs) › RTD : Pt100 Thermocouple : J, K, T, E, R, S, B, N % RH › Range : Up to 120 m outdoor line of sight Up to 40 m indoor / urban › Router to extend range › Receiver with USB port › Free utility software › Full-featured SCADA optional › Battery life : Minimum 1 year › Transmit interval : 2 to 3600 seconds ENQUIRIES Instruments: [email protected] Sensors: [email protected] Gauges: [email protected] Automation: [email protected] Level: [email protected] CAT#507R0 RADIX ELECTROSYSTEMS PVT LTD EL-135/136/137, Electronics Zone TTC Indl. Area, MIDC, Mahape Navi Mumbai - 400 710, India + 91 22 42537777 · [email protected] www.radix.co.in ZGE201 WIRELESS RTD TRANSMITTER INTRODUCTION ZGE201 is a wireless transmitter used to measure the temperature of a RTD sensor and transmit it to a wireless receiver ZGB201 connected to a PC for data logging. FEATURES Low power design › › Pt100 Input › Operates in the free radio band 2.4GHz › Transmits process temperature, ambient temperature, signal strength & battery status › User programmable transmit interval › IP65 (NEMA-4X) weather resistant enclosure SPECIFICATIONS All specifications at ambient of 25 °C, unless specified otherwise INPUT Input type Range limits Accuracy PROGRAMMABLE PARAMETERS* Device ID Transmit interval Computer interface Range of RF communication Pt100 -200 °C ~ 850 °C ±0.5 for 0~400 °C 1-48 2-3600 seconds USB for programming of parameters * software utility ZGU202 is included for configuring programmable parameters. DATA TRANSMITTED TO HOST POWER Battery Battery life Power consumption in sleep mode RF COMMUNICATION RF frequency transceiver carrier RF output power RF data packet standard MECHANICAL Wall mount Enclosure Dimensions (in mm) Protection Mounting RTD connector RTD reading, connector ambient temperature reading, RF transmit strength and battery condition 3V lithium 1 year (at 1 minute transmit interval) Below 100uA ISM 2.4GHz, direct sequence spread spectrum 10dBm (1mW) Head mount Enclosure Dimensions (in mm) Up to 120 m outdoor line of sight Up to 40 m indoor / urban IEEE 802.15.4, open communication architecture ABS plastic 80(L) x 82(W) x 55(H) (without antenna) IP65 (NEMA-4X) weather resistance enclosure Wall/Surface PG7, suitable for cable dia 3 to 6.5 mm or Integral RTD sensor Protection Mounting RTD sensor ABS plastic 95(L) x 98(W) x 83(H) (without antenna & integral probe) IP65 Head Integral probe ENVIRONMENTAL CONDITIONS Operating ambient temperature Relative humidity 0 °C to 50 °C Below 90%, non condensing ZGE201 www.radix.co.in ZGE201 WIRELESS RTD TRANSMITTER ORDERING INFORMATION SENSOR DRAWING Sensor Length (L) for Head mount integral sensor Order Code A Construction B 2550 1 Wall mount enclosure with integral RTD sensor 0 Not applicable 2 Wall mount enclosure with remote RTD Sensor 1 150mm 3 Head mount RTD Sensor 2 300mm Note1: Sensor input type & sensor length (L) is not applicable for wall mount enclosure. Order code for wall mount enclosure with integral RTD sensor will be 2550-1-0 6 ZGE201 www.radix.co.in ZGE202 WIRELESS THERMOCOUPLE TRANSMITTER INTRODUCTION ZGE202 is a wireless transmitter used to measure the temperature of a thermocouple and transmit it to a wireless receiver ZGB201 connected to a PC for data logging. FEATURES Low power design › › User configurable for type J, K, T, E, R, S, B, N Thermocouple Input › Operates in the free radio band 2.4GHz › Transmits process temperature, ambient temperature, signal strength & battery status › User programmable transmit interval › IP65 (NEMA-4X) weather resistant enclosure SPECIFICATIONS All specifications at ambient of 25 °C, unless specified otherwise INPUT Input type Range limits Accuracy Thermocouple : J, K, T, E, R, S, B, N Refer table 1 Refer table 1 PROGRAMMABLE PARAMETERS* Input Device ID Transmit interval Computer interface J, K, T, E, R, S, B, N 1-48 2-3600 seconds USB for programming of parameters * software utility ZGU202 is included for configuring programmable parameters. DATA TRANSMITTED TO HOST POWER Battery Battery life Power consumption in sleep mode RF COMMUNICATION RF frequency transceiver carrier RF output power Range of RF communication RF data packet standard MECHANICAL Wall mount with Remote Thermocouple Enclosure Dimensions (in mm) Protection Mounting Cable entry Thermocouple reading, connector ambient temperature reading, RF transmit strength and battery condition 3V lithium 1 year (at 1 minute transmit interval) Below 100uA ISM 2.4GHz, direct sequence spread spectrum 10dBm (1mW) Head Thermocouple Enclosure Dimensions (in mm) Up to 120 m outdoor line of sight Up to 40 m indoor / urban IEEE 802.15.4, open communication architecture ABS plastic 80(L) x 82(W) x 55(H) (without antenna) IP65 (NEMA-4X) weather resistance enclosure Wall/Surface PG7, suitable for cable dia 3 to 6.5 mm Protection Mounting Thermocouple sensor ABS plastic 95(L) x 98(W) x 83(H) (without antenna & integral probe) IP65 Head Integral probe ENVIRONMENTAL CONDITIONS Operating ambient temperature Relative humidity 0 °C to 50 °C Below 90%, non condensing ZGE202 www.radix.co.in ZGE202 WIRELESS THERMOCOUPLE TRANSMITTER TABLE1 RANGE LIMITS SENSOR / INPUT TYPICAL ACCURACY WORST CASE ACCURACY AT 30 °C (°C / EU) LOW SCALE HIGH SCALE LOW SCALE HIGH SCALE (°C / EU) RANGE IN WHICH ACCURACY IS SPECIFIED (°C / EU) Iron / Constantan (J) -210 760 0 760 ±1 ±3 Chromel / Alumel (K) -270 1372 -50 1200 ±1 ±3 Copper / Constantan (T) -270 400 -200 400 ±1 ±3 Chromel / Constantan (E) -270 850 0 850 ±1 ±3 Pt / Pt - 13% Rh (R) 0 1760 400 1760 ±2 ±5 Pt / Pt - 10% Rh (S) 0 1760 400 1760 ±2 ±5 Pt - 6% Rh / Pt - 30% Rh (B) 400 1820 400 1820 ±3 ±5 Nicrosil / Nisil (N) -270 1300 -50 1200 ±1 ±3 SENSOR DRAWING ORDERING INFORMATION Order Code A Construction 2572 1 Wall mount enclosure for remote Thermocouple 2 Head mount Thermocouple Sensor B Thermocouple input type for C Head mount integral sensor Sensor Length (L) for Head mount integral sensor 0 Not applicable 0 Not applicable 1 J 1 150mm 2 K 2 300mm 3 T 4 E 5 R 6 S 7 B 8 N Note1: Sensor input type & sensor length (L) is not applicable for wall mount enclosure. Order code for wall mount will be 2572-1-0-0 6 ZGE202 www.radix.co.in ZGE203 WIRELESS RELATIVE HUMIDITY & TEMPERATURE TRANSMITTER INTRODUCTION ZGE203 is a wireless transmitter used to measure the Relative Humidity and Temperature and transmit it to a wireless receiver ZGB201 connected to a PC for data logging. FEATURES Low power design › › Intergral RH+T sensor › Operates in the free radio band 2.4GHz › Transmits relative humidity, temperature, signal strength & battery status › User programmable transmit interval › IP65 (NEMA-4X) weather resistant enclosure SPECIFICATIONS All specifications at ambient of 25 °C, unless specified otherwise INPUT Sensor type Range limits Normal Maximum ACCURACY Linearity & calibration Temperature effect on accuracy Supply voltage effect Supply ripple effect, 50/60 hz, 5 Vp - p PROGRAMMABLE PARAMETERS* Device ID Transmit interval Computer interface Capacitive for RH, Semiconductor (Band gap) for temperature 0~100% RH, non-condensing -20~100 °C (-4~212 °F) -40~120 °C (-40~248 °F) (See fig.1) ± 2% RH, ± 0.5 °C ± 0.5% of span / 25 °C ± 0.002% of span / V ± 0.005% of span 1-48 2-3600 seconds USB for programming of parameters * software utility ZGU202 is included for configuring programmable parameters. DATA TRANSMITTED TO HOST Relative humidity, temperature, RF transmit strength and battery condition POWER Battery Battery life Power consumption in sleep mode RF COMMUNICATION RF frequency transceiver carrier RF output power Range of RF communication RF data packet standard MECHANICAL Enclosure Dimensions (in mm) Protection 3V lithium 1 year (at 1 minute transmit interval) Below 100uA ISM 2.4GHz, direct sequence spread spectrum 10dBm (1mW) Up to 120 m outdoor line of sight Up to 40 m indoor / urban IEEE 802.15.4, open communication architecture Mounting Humidity sensor ABS plastic 80(L) x 82(W) x 55(H) (without antenna) IP65 (NEMA-4X) weather resistance enclosure Wall/Surface Intergral sensor ENVIRONMENTAL CONDITIONS Operating ambient temperature Relative humidity 0 °C to 50°C Below 90%, non condensing ZGE203 www.radix.co.in ZGE203 WIRELESS RELATIVE HUMIDITY & TEMPERATURE TRANSMITTER OPERATING RANGE OF SENSOR Fig 1 100 [%RH] Maximum operating* conditions 80 60 Normal operating* conditions 40 20 0 -40 [°C] -20 0 20 40 60 80 100 120 * Normal operating conditions : RH+T limits for continuous safe use Maximum operating conditions : RH+T limits for use for short periods of time without damage ORDERING INFORMATION ITEM MODEL ORDER CODE WIRELESS RELATIVE HUMIDITY & TEMPERATURE ZGE203 2574 ZGE203 www.radix.co.in ZGB201 WIRELESS RECEIVER INTRODUCTION The ZGB201 wireless receiver is a compact device that receives the transmitted signals from ZGE201, ZGE202, ZGE203 Transmitter & ZGB202 Router and display / log / Graph the data on your PC. ZGU201 software is included with each unit for displaying Process value, Ambient temperature, along with RF signal strength & battery condition. FEATURES Receive Signal from ZGE201, ZGE202, ZGE203 › transmitter & ZGB202 Repeater › USB powered › Upto 48 channel reception through USB connection › ZGU201 windows based software included for display & logging ORDERING INFORMATION MODEL ORDER CODE WIRELESS RECEIVER ZGB201 2551 SPECIFICATIONS ITEM All specifications at ambient of 25 °C, unless specified otherwise POWER Supply voltage SOFTWARE Computer interface OS Number of channels RF COMMUNICATION RF frequency transceiver carrier RF output power Range of RF communication RF data packet standard MECHANICAL Enclosure Dimensions (in mm) USB-Powered, upto 40mA USB for programming initial parameters (one interface cable included with receiver) Compatible with Windows 2000, XP, 7, vista 32-bit processor Up to 48 channel ISM 2.4GHz, direct sequence spread spectrum 10dBm (1mW) Up to 120 m outdoor line of sight Up to 40 m indoor / urban IEEE 802.15.4, open communication architecture Mounting Metal 90(L) x 90(W) x 20(H) (without antenna) Wall/Surface ENVIRONMENTAL CONDITIONS Operating ambient temperature Relative humidity 0 °C to 50 °C Below 90%, non condensing ZGB201 www.radix.co.in ZGB202 WIRELESS ROUTER INTRODUCTION The ZGB202 wireless Router is a compact device that receives & retransmit signal to the host. FEATURES › Amplifies weak signal & retransmit to destination ORDERING INFORMATION ORDER CODE ZGB202 2552 SPECIFICATIONS WIRELESS ROUTER MODEL All specifications at ambient of 25 °C, unless specified otherwise ITEM POWER Supply voltage RF COMMUNICATION RF frequency transceiver carrier RF output power Range of RF communication RF data packet standard MECHANICAL Enclosure Dimensions (in mm) 5V Eliminator, up to 1A ISM 2.4GHz, direct sequence spread spectrum 10dBm (1mW) Up to 120 m outdoor line of sight Up to 40m indoor / urban IEEE 802.15.4, open communication architecture Mounting Metal 90(L) x 90(W) x 20(H) (without antenna) Wall/Surface ENVIRONMENTAL CONDITIONS Operating ambient temperature Relative humidity 0 °C to 50 °C Below 90%, non condensing ZGB202 www.radix.co.in