Wiring Diagram 208/230 Volt / 3 Phase / 60 Hz

   EMBED


Share

Transcript

WIRING DIAGRAM 3-5 Ton Package 2 Stage Gas/Single Stage Air Conditioner BLUE BLOWER CONTROL BOARD FLAME ROLL-OUT LIMIT R C Y1 DEHUM GREEN TWIN BLUE Diagnostic Description Control Fault (No Power) L1/ Neutral Polarity Fault 1 Hour Lockout Normal Operation Pressure Switch Stuck Closed with Inducer Off Pressure Switch Stuck Open with Inducer On Open Limit Switch Fault Motor Fault Pressure Switch Open Fault (Blocked Vent or Condensate) Diagnostic Description Low Flame Sensor Signal Flame Present STATUS INDUCER LIMIT INDOOR BLOWER MOTOR RED RED BLACK GREEN BLUE ORANGE WHITE BROWN 2 24V INPUT 24V OUTPUT BLACK COM HIGH LOW W2 W1 3 2 3 2 RED FLAME SENSOR RED 1 2 3 4 5 BLACK LINE- N YELLOW LINE- N BLACK BLACK YELLOW BROWN XMFR-N BLACK 1 HUM BLACK 6 BLACK SEE NOTE 6 WHITE GREEN CONTACTOR WHITE RED RED RED COMPRESSOR BLACK TO 208/230-3-60 POWER SUPPLY G C L W1 R Y2 E O Y1 W2 GRAY GREEN 9 8 7 6 5 4 3 2 1 9 8 7 6 5 4 3 2 1 RED RED ORANGE BLUE YELLOW BLACK GREY GREEN 9 8 7 6 5 4 3 2 1 230 RED DISCHARGE AIR SENSOR COM WHITE ECONOMIZER JUMPER HARNESS ASSY 8-WIRE YELLOW BROWN BLUE YELLOW GND 24V 208 TRANSFORMER BLACK T2 LEGEND: FIELD WIRING LOW VOLTAGE HIGH VOLTAGE 9 5 LINE L3 8 4 BLACK EAC T3 11 12 7 LINE L2 10 BLWR OFF DELAY GAS CONTROL XMFR T1 T2 2 STAGE GAS VALVE VIOLET YELLOW T3 VIOLET BLACK BLUE L1 C R 1 GREEN HPS BLACK T1 G WHITE ORANGE 1 BLACK YELLOW Y1 Y/Y2 3 CRANKCASE HEATER (IF EQUIPPED) BLACK ORANGE BLACK BLUE INDUCER HALL SWITCH YE CCH C LOW PRESSURE SWITCH 9 8 7 6 5 4 3 2 1 ECONOMIZER PLUG YELLOW WHITE RED BLACK BROWN BROWN 1 1 2 2 3 3 2 R S YELLOW HIGH PRESSURE SWITCH 1 OUTDOOR FAN MOTOR GREEN W RX TX COM C R YELLOW YE YE Flash Yellow LED Continuous Flash On BLACK BLACK YELLOW Off WHITE WHITE YE Green LED Red LED Off Off Flash Flash Alternating Flash On On On Flash Flash On Flash Off On Off 2 Flash HEAT COOL Flash BLOWER MOTOR On Flash 1. Couper le courant avant de faire letretien. 2. Employez uniquement des conducteurs en cuivre. 3. Ne convient pas aux installations de plus de 150 volt a la terre. BLOWER HARNESS RED GREEN On On HIGH TEMP LIMIT 1 Off W1 P8 Off BLUE EXPANSION PORT Red LED P4 Green LED 4. For replacement wires use conductors suitable for 105 deg.C. 5. For ampacities and overcurrent protection, see unit rating plate. 6. For 208-230V Models only. For 208V operation remove wire from 230V tap and place on 208V tap. TEST PORT Blower Control Diagnostic Description Control Fault (No Power) Normal Operation Motor Fault Communications Fault 208/230 Volt / 3 Phase / 60 Hz 1 NOTES: 1. Disconnect all power before servicing. 2. For supply connections use copper conductors only. 3. Not suitable on systems that exceed 150 volts to ground. INDUCER MOTOR IGNITOR 7113830 01/29/14