Wiring Diagrams Electric Unit Heaters (2

   EMBED


Share

Transcript

2-424.4 May, 2005 WIRING DIAGRAMS Models HER, VE, PTE electric unit heaters Two-In One Diagrams Two wiring diagrams are furnished for each circuit configuration in this manual. Included are a connection diagram at the left for field installation and a circuit schematic at the right to aid in continuity and trouble shooting. Solid lines show pre-wiring performed at the factory; dotted lines inform the installer of connections required to put the heater in operation. NOTE: As indicated in every diagram, all wiring must comply with the National Electrical Code and all local codes. All components must agree with their respective power source. Wiring Diagram Selection Diagrams are readily identified in the page location index on the following page. This allows for the correct wiring diagram to be selected using the model, size, and power code of the unit heater. Select the correct wiring diagrams as follows: 1. 2. 3. Determine unit heater model and size. Select power code number from Table 2.3. Reference unit heater model in the Page Location Index (Table 2.4) with power code number of the corresponding wiring diagram. CAUTION Turn off all power to unit before wiring. Failure to wire this unit according to this wiring diagram may result in injury to the installer or user. For deviations, contact factory. Abbreviations and Symbols To facilitate inter pretation and enable simplification the abbreviations and symbols have been selected as recommended by ANSI (American National Standards Institute) and NEMA (National Electrical Manufacturers Association) standards. XFMR or TR V Hz φ LC THERM or TH G HTR H SW C "J" Box L H1, H2, etc. O.L.C. R Rc VA X1,X2, etc. L1, L2, etc. T1, T2, etc. Transformer Volts Cycle or Hertz Phase Limit Control Thermostat Ground Heater Hot or High Switch Common Junction Box Low Transformer Primary Terminals Overload Contact Relay Relay Contact Volt-Ampere Transformer Secondary Terminals Electric Load Terminals Starter or Motor Terminals Wire Color Coding BK Black BU Blue R Red W White Y Yellow Wire Color Coding BK Black BL Blue R Red W White Y Yellow X1,X2, etc. Transformer Secondary Terminals L1, L2, etc. Electric Load Terminals T1, T2, etc. Starter or Motor Terminals 2-424.4 — WIRING DIAGRAMS MODELS HER, VE, PTE Table 2.1 Unit Power Requirements (AMPS) - HER Models Power Supply 208/1 240/1 208/3 240/3 480/3 HER 50 HER 75 HER100 HER125 HER150 HER200 HER250 24.5 21.3 14.3 12.5 6.5 36.5 31.7 21.3 18.5 9.5 49.4 42.9 29.0 25.3 13.3 36.0 31.4 16.3 42.9 37.4 19.3 56.8 49.4 25.3 70.7 61.4 31.4 Table 2.2 Unit Power Requirements (AMPS) - VE & PTE Models Power Supply 208/1 240/1 208/3 240/3 480/3 VE 50 21.4 14.5 12.7 6.7 VE 75 31.9 21.4 18.6 9.7 VE 100 VE 150 VE 200 VE 250 42.3 28.3 24.6 12.7 42.5 37.0 19.0 49.0 25.0 31.0 Table 2.3 Power Code Selection 208V/1φ Power Code 11 Power Supply (Volts/Phase) 240/V1φ 208V/3φ 240V/3φ 12 31 32 480V/3φ 33 Table 2.4 Electric Unit Heater Page Location Index Model No. HER 50 HER 75 HER100 HER125 HER150 HER200 HER250 VE 50 VE 75 VE 100 VE 150 VE 200 VE 250 VE 300 VE 400 VE 500 PTE300 PTE400 PTE500 2 11 3 3 4 - 12 3 3 4 9 9 9 - Power Code 31 5 5 5 5 6 7 7 10 10 10 13 - 32 5 5 5 5 5 7 7 10 10 10 13 13 - 33 8 8 8 8 8 8 8 11 11 11 14 14 14 12 12 12 12 12 12 VE/PTE 300 1-stage 2-stage 19.5 37.6 VE/PTE 400 1-stage 2-stage 25.5 49.6 VE/PTE 500 1-stage 2-stage 31.5 61.5 5H70253A1 HEATING ELEMENTS * FUSED DISCONNECT SWITCH POWER TERMINAL BLOCK 208V OR 240V/60Hz/1 POWER SUPPLY CONTACTOR ALL UNITS MUST BE WIRED AS SHOWN IN THIS WIRING DIAGRAM. INCORRECT WIRING MAY BE HAZARDOUS TO PERSON AND PROPERTY. DAMAGE TO OR FAILURE OF UNITS CAUSED BY INCORRECT WIRING IS NOT COVERED BY STANDARD WARRANTY. WARNING WIRING LEGEND FIELD WIRING FACTORY WIRING WIRE NUT * SUPPLIED BY OTHERS ALL WIRING MUST COMPLY WITH NATIONAL ELECTRIC CODE AND ALL LOCAL CODES. ALL COMPONENTS MUST AGREE WITH THEIR RESPECTIVE POWER SOURCE. GROUND LUG COIL LIMIT CONTROL FAN MOTOR * LINE VOLT THERM USE LISTED THERMOSTAT HAVING A RATING OF 1/4 HP 240V OR GREATER CONTROL TERMINAL BLOCK ELECTRIC UNIT HEATER WIRING DIAGRAMS CONTACTOR COIL FAN MOTOR HEATING ELEMENTS LIMIT CONTROL THERM GROUND LUG FUSED DISCONNECT SWITCH (BY OTHERS) 208V OR 240V/60 Hz/1 Ø POWER SUPPLY 2-424.4 — WIRING DIAGRAMS MODELS HER, VE, PTE 208V or 240V, single-phase power supply, 5kw, 7.5kw Horizontal Models 3 5H70253A2 REV F 4 CONTACTOR 208V or 240V, single-phase power supply, 10kw Horizontal Model ALL UNITS MUST BE WIRED AS SHOWN IN THIS WIRING DIAGRAM. INCORRECT WIRING MAY BE HAZARDOUS TO PERSON AND PROPERTY. DAMAGE TO OR FAILURE OF UNITS CAUSED BY INCORRECT WIRING IS NOT COVERED BY STANDARD WARRANTY. WARNING WIRING LEGEND FIELD WIRING FACTORY WIRING WIRE NUT * SUPPLIED BY OTHERS ALL WIRING MUST COMPLY WITH NATIONAL ELECTRIC CODE AND ALL LOCAL CODES. ALL COMPONENTS MUST AGREE WITH THEIR RESPECTIVE POWER SOURCE. GROUND LUG COIL LIMIT CONTROL ELEMENTS HEATING * FUSED DISCONNECT SWITCH POWER TERMINAL BLOCK 208V OR 240V/60Hz/1 Ø POWER SUPPLY FUSE BLOCK FAN MOTOR * LINE VOLT THERM USE LISTED THERMOSTAT HAVING A RATING OF 1/4 HP 240V OR GREATER CONTROL TERMINAL BLOCK ELECTRIC UNIT HEATER WIRING DIAGRAMS THERM CONTACTOR COIL FAN MOTOR HEATING ELEMENTS LIMIT CONTROL FUSE FUSE GROUND LUG FUSED DISCONNECT SWITCH (BY OTHERS) 208V OR 240V/60 Hz/1 Ø POWER SUPPLY 2-424.4 — WIRING DIAGRAMS MODELS HER, VE, PTE 5H70253A4 REV E FAN MOTOR HEATING ELEMENTS * FUSED DISCONNECT SWITCH POWER TERMINAL BLOCK 208V OR 240V/60Hz/3 Ø POWER SUPPLY CONTACTOR ALL UNITS MUST BE WIRED AS SHOWN IN THIS WIRING DIAGRAM. INCORRECT WIRING MAY BE HAZARDOUS TO PERSON AND PROPERTY. DAMAGE TO OR FAILURE OF UNITS CAUSED BY INCORRECT WIRING IS NOT COVERED BY STANDARD WARRANTY. WARNING WIRING LEGEND FIELD WIRING FACTORY WIRING WIRE NUT * SUPPLIED BY OTHERS ALL WIRING MUST COMPLY WITH NATIONAL ELECTRIC CODE AND ALL LOCAL CODES. ALL COMPONENTS MUST AGREE WITH THEIR RESPECTIVE POWER SOURCE. GROUND LUG COIL LIMIT CONTROL LINE VOLT THERM * USE LISTED THERMOSTAT HAVING A RATING OF 1/4 HP 240V OR GREATER CONTROL TERMINAL BLOCK ELECTRIC UNIT HEATER WIRING DIAGRAMS LIMIT CONTROL THERM 1 15kw on 240V/3 Ø only HEATING ELEMENTS CONTACTOR COIL GROUND LUG FUSED DISCONNECT SWITCH (BY OTHERS) FAN MOTOR POWER SUPPLY 208V OR 240V/60Hz/3 Ø 2-424.4 — WIRING DIAGRAMS MODELS HER, VE, PTE 208V or 240V, three-phase power supply, 5kw, 7.5kw, 10kw, 12.5kw, 15kw Horizontal Models 5 5H70253A5 6 208V, three-phase power supply, 15kw Horizontal Model 208V/60Hz/3 Ø POWER SUPPLY FAN MOTOR HEATING ELEMENTS * FUSED DISCONNECT SWITCH POWER TERMINAL BLOCK CONTACTOR FUSE BLOCK ALL UNITS MUST BE WIRED AS SHOWN IN THIS WIRING DIAGRAM. INCORRECT WIRING MAY BE HAZARDOUS TO PERSON AND PROPERTY. DAMAGE TO OR FAILURE OF UNITS CAUSED BY INCORRECT WIRING IS NOT COVERED BY STANDARD WARRANTY. WARNING WIRING LEGEND FIELD WIRING FACTORY WIRING WIRE NUT * SUPPLIED BY OTHERS ALL WIRING MUST COMPLY WITH NATIONAL ELECTRIC CODE AND ALL LOCAL CODES. ALL COMPONENTS MUST AGREE WITH THEIR RESPECTIVE POWER SOURCE. GROUND LUG COIL LIMIT CONTROL LINE VOLT THERM * USE LISTED THERMOSTAT HAVING A RATING OF 1/4 HP 240V OR GREATER CONTROL TERMINAL BLOCK ELECTRIC UNIT HEATER WIRING DIAGRAMS THERM LIMIT CONTROL FUSE COIL FUSE HEATING ELEMENTS GROUND LUG FUSED DISCONNECT SWITCH (BY OTHERS) CONTACTOR FAN MOTOR 208V/60Hz/3 Ø POWER SUPPLY 2-424.4 — WIRING DIAGRAMS MODELS HER, VE, PTE 5H70253A6 ELEMENTS HEATING ELEMENTS HEATING WIRING LEGEND FIELD WIRING FACTORY WIRING WIRE NUT * SUPPLIED BY OTHERS ALL WIRING MUST COMPLY WITH NATIONAL ELECTRIC CODE AND ALL LOCAL CODES. ALL COMPONENTS MUST AGREE WITH THEIR RESPECTIVE POWER SOURCE. GROUND LUG ALL UNITS MUST BE WIRED AS SHOWN IN THIS WIRING DIAGRAM. INCORRECT WIRING MAY BE HAZARDOUS TO PERSON AND PROPERTY. DAMAGE TO OR FAILURE OF UNITS CAUSED BY INCORRECT WIRING IS NOT COVERED BY STANDARD WARRANTY. WARNING 208V OR 240V/60Hz/3 Ø POWER SUPPLY FUSED DISCONNECT SWITCH * POWER TERMINAL BLOCK NO.1 FUSE BLOCK LIMIT CONTROL NO.2 FUSE BLOCK FAN MOTOR LINE VOLT THERM * USE LISTED THERMOSTAT HAVING A RATING OF 1/4 HP 240V OR GREATER CONTROL TERMINAL BLOCK NO.1 CONTACTOR COIL COIL NO.2 CONTACTOR ELECTRIC UNIT HEATER WIRING DIAGRAMS FUSE FUSE CONTACTOR FUSE CONTACTOR HEATING ELEMENTS COIL FUSE FUSE FUSE GROUND LUG FUSED DISCONNECT SWITCH (BY OTHERS) LIMIT CONTROL FAN MOTOR HEATING ELEMENTS COIL THERM POWER SUPPLY 208V OR 240V/60Hz/3 Ø 2-424.4 — WIRING DIAGRAMS MODELS HER, VE, PTE 208V or 240V, three-phase power supply, 20kw, 25kw Horizontal Models 7 5H70253A7 8 480V or 600V, three-phase power supply, 5kw thru 25kw Horizontal Models ALL UNITS MUST BE WIRED AS SHOWN IN THIS WIRING DIAGRAM. INCORRECT WIRING MAY BE HAZARDOUS TO PERSON AND PROPERTY. DAMAGE TO OR FAILURE OF UNITS CAUSED BY INCORRECT WIRING IS NOT COVERED BY STANDARD WARRANTY. WARNING WIRING LEGEND FIELD WIRING FACTORY WIRING WIRE NUT * SUPPLIED BY OTHERS ALL WIRING MUST COMPLY WITH NATIONAL ELECTRIC CODE AND ALL LOCAL CODES. ALL COMPONENTS MUST AGREE WITH THEIR RESPECTIVE POWER SOURCE. GROUND LUG COIL LIMIT CONTROL POWER SUPPLY 480V/60Hz/3 Ø POWER TERMINAL BLOCK CONTACTOR FUSE BLOCK * FUSED DISCONNECT SWITCH HEATING ELEMENTS FAN MOTOR LINE VOLT THERM * USE LISTED THERMOSTAT HAVING A RATING OF 1/4 HP 240V OR GREATER CONTROL TERMINAL BLOCK 240V X4 X2 X3 X1 TRANSFORMER 480V H1 H3 H2 H4 ELECTRIC UNIT HEATER WIRING DIAGRAMS THERM FUSE 240V 480V COIL LIMIT CONTROL FAN MOTOR FUSE FUSED DISCONNECT SWITCH (BY OTHERS) HEATING ELEMENTS CONTACTOR 480V/60Hz/3 Ø POWER SUPPLY GROUND LUG 2-424.4 — WIRING DIAGRAMS MODELS HER, VE, PTE USE LISTED THERMOSTAT HAVING A RATING OF 1/4 HP 240V OR GREATER 5H70253A8 * ALL UNITS MUST BE WIRED AS SHOWN IN THIS WIRING DIAGRAM. INCORRECT WIRING MAY BE HAZARDOUS TO PERSON AND PROPERTY. DAMAGE TO OR FAILURE OF UNITS CAUSED BY INCORRECT WIRING IS NOT COVERED BY STANDARD WARRANTY. WARNING ALL WIRING MUST COMPLY WITH NATIONAL ELECTRIC CODE AND ALL LOCAL CODES. ALL COMPONENTS MUST AGREE WITH THEIR RESPECTIVE POWER SOURCE. SIDE TERMINAL BOX LIMIT CONTROL HEATING ELEMENTS WIRING LEGEND FIELD WIRING FACTORY WIRING WIRE NUT * SUPPLIED BY OTHERS LINE VOLT THERM CONTACTOR GROUND LUG COIL POWER TERMINAL BLOCK FUSED DISCONNECT SWITCH 240V/60Hz/1Ø POWER SUPPLY POWER JUNCTION BOX CONTROL TERMINAL BLOCK * ELECTRIC UNIT HEATER WIRING DIAGRAMS FAN MOTOR CONTACTOR COIL LIMIT CONTROL GROUND LUG FUSED DISCONNECT SWITCH (BY OTHERS) FAN MOTOR HEATING ELEMENTS THERM 240V/60Hz/1 Ø POWER SUPPLY 2-424.4 — WIRING DIAGRAMS MODELS HER, VE, PTE 240V, single-phase power supply, 5kw, 7.5kw, 10kw Vertical Models 9 USE LISTED THERMOSTAT HAVING A RATING OF 1/4 HP 240V OR GREATER 5H70253A9 10 * 208V or 240V, three-phase power supply, 5kw, 7.5kw, 10kw Vertical Models ALL UNITS MUST BE WIRED AS SHOWN IN THIS WIRING DIAGRAM. INCORRECT WIRING MAY BE HAZARDOUS TO PERSON AND PROPERTY. DAMAGE TO OR FAILURE OF UNITS CAUSED BY INCORRECT WIRING IS NOT COVERED BY STANDARD WARRANTY. WARNING ALL WIRING MUST COMPLY WITH NATIONAL ELECTRIC CODE AND ALL LOCAL CODES. ALL COMPONENTS MUST AGREE WITH THEIR RESPECTIVE POWER SOURCE. SIDE TERMINAL BOX LIMIT CONTROL HEATING ELEMENTS WIRING LEGEND FIELD WIRING FACTORY WIRING WIRE NUT * SUPPLIED BY OTHERS LINE VOLT THERM COIL POWER JUNCTION BOX CONTACTOR GROUND LUG CONTROL TERMINAL BLOCK * POWER TERMINAL BLOCK FUSED DISCONNECT SWITCH 208V or 240V/60Hz/3 Ø POWER SUPPLY ELECTRIC UNIT HEATER WIRING DIAGRAMS FAN MOTOR THERM LIMIT CONTROL HEATING ELEMENTS CONTACTOR COIL FAN MOTOR GROUND LUG FUSED DISCONNECT SWITCH (BY OTHERS) 208V OR 240V/60Hz/3 Ø POWER SUPPLY 2-424.4 — WIRING DIAGRAMS MODELS HER, VE, PTE USE LISTED THERMOSTAT HAVING A RATING OF 1/4 HP 240V OR GREATER 5H70253A10 * COIL POWER JUNCTION BOX CONTACTOR GROUND LUG CONTROL TERMINAL BLOCK ALL UNITS MUST BE WIRED AS SHOWN IN THIS WIRING DIAGRAM. INCORRECT WIRING MAY BE HAZARDOUS TO PERSON AND PROPERTY. DAMAGE TO OR FAILURE OF UNITS CAUSED BY INCORRECT WIRING IS NOT COVERED BY STANDARD WARRANTY. WARNING ALL WIRING MUST COMPLY WITH NATIONAL ELECTRIC CODE AND ALL LOCAL CODES. ALL COMPONENTS MUST AGREE WITH THEIR RESPECTIVE POWER SOURCE. SIDE TERMINAL BOX LIMIT CONTROL HEATING ELEMENTS WIRING LEGEND FIELD WIRING FACTORY WIRING WIRE NUT * SUPPLIED BY OTHERS LINE VOLT THERM POWER TERMINAL BLOCK FAN MOTOR H3 H2 H4 BLUE X4 X3 X1 TRANSFORMER JUNCTION BOX FUSE BLOCK RED X2 480V TRANSFORMER 240V H1 FUSED DISCONNECT SWITCH 480V/60Hz/3 Ø POWER SUPPLY SHOWN * ELECTRIC UNIT HEATER WIRING DIAGRAMS THERM FUSE FUSE LIMIT CONTROL FAN MOTOR HEATING ELEMENTS CONTACTOR COIL 240V 480V GROUND LUG FUSED DISCONNECT SWITCH (BY OTHERS) 480V/60Hz/3 Ø POWER SUPPLY SHOWN 2-424.4 — WIRING DIAGRAMS MODELS HER, VE, PTE 480V or 600V, three-phase power supply, 5kw, 7.5kw, 10kw Vertical Models 11 12 5H70253A11 REV H LIMIT CONTROL AUX. SWITCH COIL COIL CONTROL TERMINAL BLOCK WARNING ALL UNITS MUST BE WIRED AS SHOWN IN THIS WIRING DIAGRAM. INCORRECT WIRING MAY BE HAZARDOUS TO PERSON AND PROPERTY. DAMAGE TO OR FAILURE OF UNITS CAUSED BY INCORRECT WIRING IS NOT COVERED BY STANDARD WARRANTY. ALL WIRING MUST COMPLY WITH NATIONAL ELECTRIC CODE AND ALL LOCAL CODES. ALL COMPONENTS MUST AGREE WITH THEIR RESPECTIVE POWER SOURCE. SIDE TERMINAL BOX HEATING ELEMENTS * LINE VOLT 2-STAGE THERM USE LISTED THERMOSTAT HAVING A RATING OF 1/4 HP 240V OR GREATER C CONTACTOR #2 FUSE BLOCK #2 CONTACTOR #1 FUSE BLOCK #1 POWER TERMINAL BLOCK POWER JUNCTION BOX H L GROUND LUG WIRING LEGEND FIELD WIRING FACTORY WIRING WIRE NUT * SUPPLIED BY OTHERS FAN MOTOR X4 X3 X1 TRANSFORMER JUNCTION BOX FUSE BLOCK X2 H3 H2 H4 480V TRANSFORMER 240V H1 L1 L2 L3 *230V/60Hz/3Ø POWER SHOWN 3Ø CIRCUIT BREAKER ELECTRIC UNIT HEATER WIRING DIAGRAM t° t° FUSE AUX. SWITCH FUSE HI 2-STAGE THERM LO FUSE FAN MOTOR FUSE STAGE #2 HEATING ELEMENTS CONTACTOR #2 COIL STAGE #1 HEATING ELEMENTS FUSE FUSE FUSE FUSE LIMIT CONTROL GROUND LUG 3Ø CIRCUIT BREAKER (BY OTHERS) CONTACTOR #1 COIL 240V 480V L1 L2 L3 480V/60Hz/3Ø POWER SUPPLY SHOWN 2-424.4 — WIRING DIAGRAMS MODELS HER, VE, PTE 480V or 600V, three-phase power supply, 30kw, 40kw, and 50kw Vertical and Power Throw Models 5H70253A12 * ALL UNITS MUST BE WIRED AS SHOWN IN THIS WIRING DIAGRAM. INCORRECT WIRING MAY BE HAZARDOUS TO PERSON AND PROPERTY. DAMAGE TO OR FAILURE OF UNITS CAUSED BY INCORRECT WIRING IS NOT COVERED BY STANDARD WARRANTY. WARNING ALL WIRING MUST COMPLY WITH NATIONAL ELECTRIC CODE AND ALL LOCAL CODES. ALL COMPONENTS MUST AGREE WITH THEIR RESPECTIVE POWER SOURCE. SIDE TERMINAL BOX LIMIT CONTROL HEATING ELEMENTS TIME DELAY RELAY WIRING LEGEND FIELD WIRING FACTORY WIRING WIRE NUT * SUPPLIED BY OTHERS LINE VOLT THERM CONTROL TERMINAL BLOCK USE LISTED THERMOSTAT HAVING A RATING OF 1/4 HP 240V OR GREATER CONTACTOR COIL POWER JUNCTION BOX GROUND LUG POWER TERMINAL BLOCK FAN MOTOR FUSED DISCONNECT SWITCH 208V or 240V/60Hz/3 Ø POWER SUPPLY * ELECTRIC UNIT HEATER WIRING DIAGRAMS THERM HEATING ELEMENTS LIMIT CONTROL FAN MOTOR CONTACTOR COIL TIME DELAY RELAY GROUND LUG FUSED DISCONNECT SWITCH (BY OTHERS) 208V or 240V/60Hz/3 Ø POWER SUPPLY SHOWN 2-424.4 — WIRING DIAGRAMS MODELS HER, VE, PTE 208V or 240-volt, three-phase power supply, 15kw, 20kw Vertical Models 13 5H70253A13 14 * 480V or 600-volt, three-phase power supply, 15kw, 20kw, 25kw Vertical Models ALL UNITS MUST BE WIRED AS SHOWN IN THIS WIRING DIAGRAM. INCORRECT WIRING MAY BE HAZARDOUS TO PERSON AND PROPERTY. DAMAGE TO OR FAILURE OF UNITS CAUSED BY INCORRECT WIRING IS NOT COVERED BY STANDARD WARRANTY. WARNING ALL WIRING MUST COMPLY WITH NATIONAL ELECTRIC CODE AND ALL LOCAL CODES. ALL COMPONENTS MUST AGREE WITH THEIR RESPECTIVE POWER SOURCE. SIDE TERMINAL BOX LIMIT CONTROL HEATING ELEMENTS TIME DELAY RELAY WIRING LEGEND FIELD WIRING FACTORY WIRING WIRE NUT * SUPPLIED BY OTHERS LINE VOLT THERM CONTROL TERMINAL BLOCK USE LISTED THERMOSTAT HAVING A RATING OF 1/4 HP 240V OR GREATER COIL FAN MOTOR POWER JUNCTION BOX CONTACTOR GROUND LUG POWER TERMINAL BLOCK H3 H2 H4 BLUE TRANSFORMER JUNCTION BOX FUSE BLOCK RED 480V TRANSFORMER 240V X4 X2 X3 X1 H1 FUSED DISCONNECT SWITCH 480V/60Hz/3 Ø POWER SUPPLY SHOWN * ELECTRIC UNIT HEATER WIRING DIAGRAMS TIME DELAY RELAY COIL 240V 480V LIMIT CONTROL FAN MOTOR FUSE HEATING ELEMENTS CONTACTOR THERM FUSE GROUND LUG FUSED DISCONNECT SWITCH (BY OTHERS) 480V/60Hz/3 Ø POWER SUPPLY SHOWN 2-424.4 — WIRING DIAGRAMS MODELS HER, VE, PTE (THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK) 15 For SERVICE contact your local qualified installation and service contractor or appropriate utility company. As Modine Manufacturing Company has a continuous product improvement program, it reserves the right to change design and specifications without notice. Commercial HVAC&R Division • Modine Manufacturing Company • 1500 DeKoven Avenue • Racine, Wisconsin 53403-2552 Tel: 1.800.828.4328 (HEAT) • www.modine.com © Modine Manufacturing Company 2005 5/05 - Litho in USA