Preview only show first 10 pages with watermark. For full document please download

Wise-7901 Spec Eng

   EMBED


Share

Transcript

WISE (Web Inside, Smart Engine) I/O Expansion Boards 1 Features Ethernet I/O Modules Built-in Web Server for IF-THEN-ELSE rule setting Built-in IF-THEN-ELSE rule enigne for logic operation No more programming. Just click and get done! Support IO, Counter, Timer, Email operations Modbus/TCP Protocol for SCADA Software Seamless Integration IEEE 802.3af-compliant Power over Ethernet (PoE) 10/100 Base-TX Ethernet I/O expansion bus WISE-7901/WISE-7901D Support DI/DO X-Boards: X107, X109, X110, X111 Support Multi-Function X-Boards: X202, X203, X303, X304, X305, X308, X310, X324 User-defined I/O Expansion PoE Module Introduction WISE (Web Inside, Smart Engine) is a product series developed by ICP DAS that functions as control units for use in remote logic control and monitoring in various industrial applications. WISE offers a user-friendly and intuitive web site interface that allows users to implement IF-THEN-ELSE control logic on controllers just a few clicks away; no programming is required. With its powerful and easy-to-use features, it will minimize the learning curve, shorten time to market and dramatically reduce the effort and cost spent on system development. WISE-7901 follows IEEE 802.3af-compliant (classification, Class 1) Power over Ethernet (PoE) specification. It allows receiving power from PoE enabled network by Ethernet pairs (Category 5 Ethernet cable). This feature provides greater flexibility and higher efficiency therefore simplifying systems design, saving space, reducing cables and eliminating the requirement for dedicated electrical outlets. Meanwhile, in case under a non-PoE environment, WISE-7901 will still be able to receive power from auxiliary power sources like AC adapters or battery, etc. This module WISE-7901 supports Modbus/TCP protocol to make seamless integration with SCADA software available. It supports an I/O expansion bus to implement various I/O functions such as D/I, D/O, A/D, D/A according to the using X-Board. 3 Applications Building Automation, Factory Automation, Machine Automation, Remote Maintenance, Remote diagnosis and Testing Equipment, etc. WISE-790x Series (Web based PoE) Specifications Models WISE-7901 CPU 16-bit CPU SRAM 512 KB Flash 512 KB EEPROM 16 KB NVRAM 31 Bytes OS MiniOS7 RTC (Real Time Clock) RTC Provide seconds, minutes, hours, date of week/month; month and year, valid from 1980 to 2079 64-bit Hardware Serial Number Yes Watchdog Timers Yes (0.8 second) Communication Ports Ethernet RJ-45 x 1, 10/100 Base-TX Ethernet Controller (Auto-negotiating, Auto_MDIX, LED indicators) COM 1 No (Unsupported by WISE firmware) COM 2 No (Unsupported by WISE firmware) LED Indicator Yes (Red) System LED CF LED Display - Special Indicator PoE LED (Green) 5-digit 7-segment LED display Hardware Expansion Yes I/O Expansion Bus Mechanical WISE-7901 Dimensions (W x H x D) 72 mm x 123 mm x 35 mm Installation DIN-Rail or Wall Mounting Environmental Operating Temperature -25 ~ +75 °C Storage Temperature -40 ~ +80 °C Ambient Relative Humidity 5 ~ 90% RH (non-condensing) Power Protection Power reverse polarity protection Frame Ground Yes (for ESD Protection) Input Range 1-3-? WISE-7901D CPU Module +12 ~ +48 VDC Power over Ethernet (PoE) IEEE 802.3af Class 1 Power Consumption 1.5 W ICP DAS CO., LTD 2.5 W Professional Provider of High Quality Industrial Computer Products and Data Acquisition System 型錄書名(目前未定,暫用Remote I/O Catalog) Software Specifications Functions 3 IF conditions with AND or OR operators 36 IF-THEN-ELSE Logic Rules 3 THEN actions and 3 ELSE actions 48 Internal Registers Hold temporary variables and read/write data via Modbus/TCP address. 12 Timers Delay / Timing functions. 12 Schedules Setup prescheduled routine tasks. 12 Emails Send Email messages to pre-set Email receivers. 12 CGI Commands Send pre-set CGI commands. 12 Recipes Set up THEN/ELSE action groups. 8 P2P remote modules Set up the connection information for the remote WISE modules. Modbus/TCP Protocol Real time control and monitoring I/O channels and system status of controllers via SCADA software. =、>、<、>=、<=(value) =、>、<、>=、<=(value)、Change Timeout、Not Timeout In Range、Out of Range DI、AI、DI counter、DO counter、IR Enable、Disable THEN / DO Channel AO Channel Internal Register DI Counter DO Counter Timer Schedule Email CGI Commands Recipe P2P Rule Status WISE IF-THEN-ELSE Rule Engine N/A CAN_L N/A 3 Link/Act 23 23 RL5 COM E1 E1 COM1 L1 IN5 1 IN4 RL4 COM Change the value Reset Start、Stop Send Execute DO(On/Off)、AO、IR Enable、Disable RL4 NO RL3 COM RL3 NO RL2 COM Pin Assignment 23 - 22 - 21 - 20 - 19 - 18 - 17 - 16 - 15 - 14 - 13 - 12 - 01 CTS1 02 RTS1 03 RxD1 04 TxD1 05 INIT* 06 D2+ 07 D2- 08 (R)+Vs 11 - 09 (B)GND 10 - L2 PAC -7186EXD-CAN L3 IN3 IN2 IN1 IN0 RL1 COM RL1 NO RL0 COM RL0 NO (R)Vs+ N/A 9 10 10 N/A L1 (B)GND L2 CPU: 80186-80 09 CAN: Support CAN 2.0A/2.0B E1: Ethernet 10/100 Base TX COM1: RS-232 COM2: RS-485 RL2 NO IN.COM L3 COM2 01 MiniOS 7 RL5 NO E1 WISE-7901 10/100M ELSE Actions ON、OFF、Pulse Output Terminal No. 5 N/A 2 4 CAN_H N/A 1 CAN_L N/A 3 5 N/A 2 Pin Assignment 4 CAN_H 1 Pin Assignment Terminal No. 1 IF Conditions ON、OFF、ON to OFF、OFF to ON、Change Dimensions (Unit: mm) Wiring & Boarding 3 35.0 (R)+Vs D2- D2+ INIT* TxD1 RxD1 RTS1 CTS1 RS-485 Network GND 10 ~ 30 VDC 10.9 31.7 35.4 123.0 101.2 56.0 31.7 8.0 RS-232 Device 10.9 32.3 59.2 72.0 Left Side View Front View 35 Bottom View CF X-Board User-defined I/O Expansion PoE Module (RoHS) WISE-7901D User-defined I/O Expansion PoE Module with LED Display (RoHS) Accessories GPSU06U-6 24V/0.25A, 6 W Power Supply MDR-20-24 NS-205 CR 24V/1A, 24 W Power Supply with DIN-Rail Mounting Unmanaged 5-Port Industrial Ethernet Switch (RoHS) NS-205PSE CR I/O Expansion Boards Unmanaged 5-Port Industrial PoE Ethernet Switch (RoHS) Other add-on expansion boards: X107, X109, X110, X111, X202, X203, X303, X304, X305, X308, X310, X324 Email: [email protected] WISE-7901 Ordering Information WISE-7901 Website: http://wise.icpdas.com WISE-790x Series (Web based PoE) Ethernet Internet Intranet COM2 (B)GND 9 1 49.8 COM1 Ethernet I/O Modules DI Channel AI Channel Internal Register DI Counter DO Counter Timer Schedule P2P Rule Status Access Web server on WISE controllers to edit and upload logic rules through web browser. Rule Configuration Website 1-3-?