Transcript
WITH BRITA, I OPTIMISE WATER PROFESSIONALLY An overview of our products
Filter management app Download our free of charge BRITA Professional FilterManager app and get a reminder for your next filter exchange – automatically, wherever you are. For smartphone and tablets. For more information please visit: www.professional.brita.net / app
IntelliBypass® technology with
IntelliBypass
A largely volumetric-flow-independent bypass water percentage ensures constant water quality, also for low flow rates (for small-volume drinks such as espresso). The IntelliBypass® supports: consistently high water quality the best taste by improving the development of the aromas of food and drinks secure machine protection and thus the reduction of additional repair costs
Content Products PURITY C Quell ST PURITY Finest C500 PURITY Fresh C50 PURITY C1000 AC
4 6 8 10
PURITY Quell ST PURITY Finest PURITY Steam PURITY 1200 Clean PURITY 1200 Clean Extra
12 14 16 18 20
AquaVend Cool Aqua Aroma Aqua Aroma Crema
22 24 26
Remote display FlowMeter 10 – 100 A FlowMeter 100 – 700 A
28 30 31
Bypass and capacity tables PURITY C Quell ST PURITY Quell ST PURITY Finest PURITY Finest C500 PURITY Steam PURITY 1200 Clean PURITY 1200 Clean Extra
32 40 41 42 43 44 45
Certifications
46
Only drinking quality water may be used as the water supply for BRITA water filters.
3
An overview of our products Product
Sizes
Capacity /operational life Operating position
PURITY C Quell ST
PURITY Finest C
PURITY Fresh C
PURITY C AC
PURITY Quell ST
C50 C150 C300 C500 C1100
C500
C50
C1000
450 600 1200
960 – 11,500 l
3,414 l
12,000 l
10,000 l
4,217 –13,187 l
horizontal and vertical
vertical
horizontal and vertical
horizontal and vertical
horizontal and vertical
4
6
8
10
12
Application Coffee
Vending
Combi steamers
Conventional ovens
Dishwashers
Cooler
Page
PURITY Finest
PURITY Steam
PURITY Clean
PURITY Clean Extra
600 1200
450 600 1200
1200
1200
12,000 l
5,000 l
4,400 – 8,150 l 3,680 – 10,800 l vertical
horizontal and vertical
horizontal and vertical
horizontal and vertical
14
16
18
20
AquaVend Cool
AquaAroma
AquaAroma Crema
approx, 5,000 l or 6 months
81 – 242 l
80 – 220 l
22
24
26
PURITY C Quell ST Technology Decarbonisation
The ideal solution for all those who want to fulfil the highest quality expectations.
with
IntelliBypass
The PURITY C Quell ST, with five different filter sizes, stands for a reliable reduction in carbonate hardness and thus in substances leading to lime scale deposits. In addition it reduces unwanted taste and aroma elements and particles and thereby ensures optimum product quality and long operational life of the machine. At the same time, the PURITY C Quell ST filters impress with their simple handling and fitting even in tight installa tion conditions.
4
PURITY C Quell ST
C50
C150
C300
C500
C1100
Filter head PURITY C 0 – 70 % with variable bypass Capacity1 with a carbonate hardness of 10 °dH Coffee / espresso / vending machines (bypass setting 40 %)
960 l
2,408 l
4,000 l
6,800 l
11,500 l
Capacity1 with a carbonate hardness of 10 °dH Combi steamers and conventional ovens (bypass setting 10 %)
660 l
1,656 l
2,750 l
4,675 l
7,906 l
831 l
2,086 l
3,464 l
5,889 l
9,960 l
600 l
1,505 l
2,500 l
4,250 l
7,188 l
Filter head PURITY C 30 % with fixed bypass Capacity1 with a carbonate hardness of 10 °dH Filter head PURITY C 0 % with fixed bypass Capacity1 with a carbonate hardness of 10 °dH
Comparable capacity according to DIN 18879-1:2007: The comparable capacity is a standardised indicator to facilitate comparison of different filters. The comparable capacity is determined under extreme conditions. Normally the usable capacity in practical operation is clearly higher than the comparable capacity and may vary greatly depending on the usage conditions Comparable capacity
435 l
1,278 l
Max. operating pressure
2,199 l
4,125 l
8,670 l
8.6 bar
Water intake temperature
4 – 30 °C
Nominal flow Pressure loss at nominal flow
60 l / h
100 l / h
0.25 bar
0.5 bar
Dimensions (W / D / H) with filter head
119 / 108 / 268 mm
Weight (dry/wet)
1.0 / 1.6 kg 1.8 / 2.8 kg 2.8 / 4.2 kg 4.6 / 6.9 kg 7.7 / 12.5 kg
Connections (input / output) Operating position Operation
117 / 104 / 125 / 119 / 144 / 144 / 184 / 184 / 419 mm 466 mm 557 mm 557 mm G 3 / 8" or John Guest* 8 mm horizontal and vertical
use after inhouse softening units possible
The capacities given have been tested and calculated on the basis of normal application and machine conditions. Due to external influences (e.g. variations in raw water quality and/or machine type), deviations from these results can occur. * Not available in Switzerland 1
You can find further bypass and capacity information on pages 32 – 39.
5
PURITY Finest C500 Technology Softening
The ideal solution for those who want to offer their consumers a unique espresso experience.
with
IntelliBypass
PURITY Finest optimised water, with its ideal mineral composition, releases the typical aromas from the ground coffee beans and supports the develop ment of the authentic espresso taste. In addition, the water ensures a stable crema with a colour and consistency not achieved before, making the espresso and coffee specialities a particu lar pleasure. At the same time, the PURITY Finest C filter impresses with its simple handling and fitting even in tight installation conditions.
6
PURITY Finest
C500
Capacity1 with a total hardness of 10 °dH and 0% bypass2
3,414 l
Max. operating pressure
8.6 bar
Water intake temperature
4 – 30 °C
Flow at 1 bar pressure loss
140 l / h
Nominal flow
100 l / h
Pressure loss at nominal flow
0.5 bar
Dimensions (W / D / H) Filter head with filter cartridge
144 / 144 / 557 mm
Weight (dry / wet) Connections (input / output)
4.6 / 6.9 kg G 3 / 8" or John Guest* 8 mm
Operating position
vertical
The capacities given have been tested and calculated on the basis of normal application and machine conditions. Due to external influences (e.g. variations in raw water quality and / or machine type), deviations from these results can occur. 2 PURITY Finest C500 cartridges must be operated with a bypass setting of 0 %. * Not available in Switzerland 1
You can find further bypass and capacity information on page 42.
7
PURITY Fresh C50 Technology Activated carbon filtration
Along with the optimised quality of the water, the machine is also protected and a large proportion of the negative influences caused by the properties of the water can be eliminated.
The PURITY Fresh C50 was specifically developed for soft water areas with high particle densities. The activated carbon mixture reliably retains these particles from the machine and end product and ensures a clear, fresh taste.
8
PURITY Fresh Capacity1
C50 12,000 l
Max. operating pressure
8.6 bar
Water intake temperature
4 – 30 °C
Flow at 1 bar pressure loss
160 l / h
Nominal flow Pressure loss at nominal flow Empty filter cartridge volume Dimensions (W / D / H) with filter head Weight (dry / wet) Connections (input / output) Operating position
60 l / h 0.25 bar 1 l 119 / 108 / 268 mm 0.7 / 1.5 kg G 3 / 8" or John Guest* 8 mm horizontal and vertical
The capacities given have been tested and calculated on the basis of normal application and machine conditions. Due to external influences (e.g. variations in raw water quality and / or machine type), deviations from these results can occur. *Not available in Switzerland
1
9
PURITY C1000 AC Technology Activated carbon filtration
The optimum filter medium for water dispensers.
The PURITY C1000 AC, with the fine pores in its activated carbon block, filters unwanted taste and aroma elements out of the water, in particular small particles down to 0.5 μm in accordance with NSF standard 42, as well as any contamination caused by the installation
10
PURITY Capacity1
C1000 AC 10,000 l
Max. operating pressure
8.6 bar
Water intake temperature
4 – 30 °C
Operating flow range and associated pressure loss
30 – 180 l / h / 0.2 – 1.4 bar
Flow at 1 bar pressure loss Chlorine reduction
140 l / h DIN EN 14898 Klasse 1 (> 90 %)
Chlorine reduction
NSF 42 Class I (50 %)
Particle retention
NSF 42 Class I (0.5 μm)
Dimensions (W / D / H) with filter head Weight (dry / wet) Connections (input / output) Operating position
109 / 93 / 238 mm 0.5 / 1.0 kg G 3 / 8" or John Guest* 8 mm horizontal and vertical
The capacities given have been tested and calculated on the basis of normal application and machine conditions. Due to external influences (e.g. variations in raw water quality and / or machine type), deviations from these results can occur. *Not available in Switzerland 1
11
PURITY Quell ST Technology Decarbonisation
The ideal solution for those who want to fulfil the highest quality expectations.
with
IntelliBypass
The PURITY C Quell ST uses three different filter sizes to provide a reliable reduction in carbonate hardness and thus in substances forming limescale, as well as unwanted taste and aroma elements and particles. As a result, it ensures optimum product quality and the long operational life of machines. The filters in the PURITY Quell ST series are always the right decision if high flow rates are required.
12
PURITY Quell ST Capacity1 with a carbonate hardness of 10 °dH Coffee / espresso / vending machines (bypass setting 40 %)
450
600
1200
4,217 l
7,207 l
13,187 l
Comparable capacity according to DIN 18879-1:2007: The comparable capacity is a standardised indicator to facilitate comparison of different filters. The comparable capacity is determined under extreme conditions. Normally the usable capacity in practical operation is clearly higher than the comparable capacity and may vary greatly depending on the usage conditions. Comparable capacity
2,240 l
4,420 l
Max. operating pressure
6.9 bar
Water intake temperature
4 – 30 °C
Flow at 1 bar pressure loss Nominal flow Pressure loss at nominal flow Dimensions (height / width) Weight (dry/wet) Connections (input / output) Operating position Operation 1
7,253 l
350 l / h 60 l / h
120 l / h
0.12 bar
0.36 bar
0.32 bar
408 / 249 mm
520 / 249 mm
550 / 288 mm
12 / 15 kg
18 / 24 kg
10 / 12 kg
G 1" / G 3/4" horizontal and vertical
use after inhouse softening units possible
The capacities given have been tested and calculated on the basis of normal application and machine conditions. Due to external influences (e.g. variations in raw water quality and / or machine type), deviations from these results can occur.
You can find further bypass and capacity information on page 40.
13
PURITY Finest Technology Softening
The ideal solution for those who want to offer their consumers a unique espresso experience.
with
IntelliBypass
PURITY Finest optimised water, with its ideal mineral composition, releases the typical aromas from the ground coffee beans and thus supports the development of the authentic espresso taste. In addition, the water ensures a stable crema with a colour and consistency not achieved before, making espresso and coffee specialities a particular pleasure. The filters in the PURITY Finest series are always the right decision if high flow rates are required.
14
PURITY Finest Capacity1 with a total hardness of 10 °dH (bypass setting 0%2)
600
1200
4,400 l
8,150 l
Comparable capacity according to DIN 18879-1:2007: The comparable capacity is a standardised indicator to facilitate comparison of different filters. The comparable capacity is determined under extreme conditions. Normally the usable capacity in practical operation is clearly higher than the comparable capacity and may vary greatly depending on the usage conditions. Comparable capacity
3,038 l
5,566 l
Max. operating pressure
6.9 bar
Water intake temperature
4 – 30 °C
Flow at 1 bar pressure loss
350 l / h
Nominal flow Pressure loss at nominal flow Dimensions (height / width) Weight (dry / wet)
120 l / h 0.36 bar
0.32 bar
520 / 249 mm
550 / 288 mm
12 / 15 kg
Connections (input / output) Operating position
18 / 24 kg G 1" / G 3 / 4" vertical
he capacities given have been tested and calculated on the basis of normal application and T machine conditions. Due to external influences (e.g. variations in raw water quality and / or machine type), deviations from these results can occur. 2 PURITY Finest cartridges must be operated with a bypass setting of 0 %. 1
You can find further bypass and capacity information on page 41.
15
PURITY Steam Technology Decarbonisation
The ideal solution for preparing unique dishes in machines that work smoothly and provide the highest performance over a long period. Benefit from the bypass setting specifically adapted for different steamers ensuring improved flow performance.
with
IntelliBypass
The PURITY Steam with its filter media specifically tailored to the requirements of steam cooking and baking, removes ions that cause limescale from the water as well as chlorine and particles. The result is a partial demineralised water of the highest quality. The machines are protected even longer against limescale deposits.
16
PURITY Steam
450
600
1200
Capacity1 with a carbonate hardness of 10 °dH 3,680 l 5,771 l 10,800 l (bypass position 1) Comparable capacity according to DIN 18879-1:2007: The comparable capacity is a standardised indicator to facilitate comparison of different filters. The comparable capacity is determined under extreme conditions. Normally the usable capacity in practical operation is clearly higher than the comparable capacity and may vary greatly depending on the usage conditions. Comparable capacity
Bypass setting
4,734 l
Max. operating pressure
6.9 bar
Water intake temperature
4 – 30 °C
Flow at 1 bar pressure loss
500 l / h
Nominal flow
120 l / h
Pressure loss at nominal flow
0.36 bar
Dimensions (height / width) Weight (dry / wet) Connections (input / output) Operating position Operation 1
2,754 l
9,521 l
Position 0: All devices in areas with an extremely high water hardness level (KH ≥ 22 °dH) Position 1: Combi ovens and conventional ovens with direct injection system Position 2: Combi ovens and conventional ovens with boiler system Position 3: All devices in soft water areas (KH ≤ 7 °dH)
408 / 249 mm
520 / 249 mm
550 / 288 mm
10 / 12 kg
12 / 15 kg
18 / 24 kg
G 1" / G 3/4" horizontal and vertical
use after inhouse softening units possible
he capacities given have been tested and T calculated on the basis of normal application and machine conditions. Due to external influences (e.g. variations in raw water quality and / or machine type), deviations from these results can occur.
You can find further bypass and capacity information on page 43.
17
PURITY 1200 Clean Technology Partial demineralisation
The ideal solution for professional washing of cutlery, glass and crockery directly at the bar. For feed water with high carbonate hardness and unproblematic additional mineral content.
with
IntelliBypass
The PURITY 1200 Clean removes the ions that cause limescale and particles from the feed water in a targeted way. The result is partially demineralised water for ideal washing results.
18
PURITY Clean Capacity1 with a carbonate hardness of 10 °dH (bypass setting 0 %)
12,000 l
Max. operating pressure
6 bar
Water intake temperature
4 – 60 °C
Flow at 1 bar pressure loss
850 l / h
Nominal flow
300 l / h
Pressure loss at nominal flow Dimensions (height / width) Weight (dry / wet) Connections (input / output) Operating position 1
1200
0.45 bar 550 / 288 mm 18 / 24 kg G 1" / G 3 / 4" horizontal and vertical
he capacities given have been tested and calculated on the basis of normal application and T machine conditions. Due to external influences (e.g. variations in raw water quality and / or machine type), deviations from these results can occur.
You can find further bypass and capacity information on page 44.
19
PURITY 1200 Clean Extra Technology Total demineralisation
The ideal solution for the professional washing of high-quality cutlery, superior glasses and fine crockery directly at the bar. For raw water with high carbonate hardness and a high level of additional mineral content.
with
IntelliBypass
The PURITY 1200 Clean Extra removes particles and ions that cause limescale, marks and streaks from the raw water in a targeted way. The result is total demineralised water for first-class washing results.
20
PURITY Clean Extra Capacity1 with a total hardness of 10 °dH (bypass setting 0 %)
5,000 l
Max. operating pressure
6 bar
Water intake temperature
4 – 60 °C
Flow at 1 bar pressure loss
850 l / h
Nominal flow
300 l / h
Pressure loss at nominal flow Dimensions (height / width) Weight (dry/wet) Connections (input / output) Operating position 1
1200
0.45 bar 550 / 288 mm 18 / 24 kg G 1" / G 3/4" horizontal and vertical
he capacities given have been tested and calculated on the basis of normal application and T machine conditions. Due to external influences (e.g. variations in raw water quality and / or machine type), deviations from these results can occur.
You can find further bypass and capacity information on page 45.
21
AquaVend Cool Technology Activated carbon filtration for cold-water applications
Activated carbon filters for reliable reduction of all unwanted taste and aroma elements.
The activated carbon fibre filter provides consistently high water quality, independent of the local conditions. It also retains particles and thus provides perfect protection for the machine.
22
AquaVend Cool Capacity1 / operational life
1
5,000 l or 6 months
Filter cartridge dimensions (W / D / H)
68 / 68 / 162 mm
Complete system dimensions (W / D / H) without head attachments
69 / 69 / 191 mm
Installation dimensions (W / D / H)
69 / 69 / 215 mm
Operating pressure
2 – 8 bar
Water intake temperature
4 – 30 °C
Particle filtration
> 0.5 μm
The capacities given have been tested and calculated on the basis of normal application and machine conditions. Due to external influences (e.g. variations in raw water quality and / or machine type), deviations from these results can occur.
23
AquaAroma Technology Decarbonisation
Cartridge for use in coffee machines with Tank Fill system (gravity operation).
AquaAroma filter cartridges are suitable for use directly in the water tank in a specially designed or retro-fitted tank system, and for mobile coffee machines with an integrated water tank.
24
AquaAroma Cartridge cup diameter
89.6 mm
Height cartridge cup
36.2 mm
Water intake temperature
4 – 30 °C
Typical capacity – taking account of the local carbonate hardness Carbonate hardness °dH
Capacity in litres *
Cups 130 ml
Cups 150 ml
6
242
1,860
1,610
8
181
1,390
1,210 970
10
145
1,120
12
120
930
810
14
103
800
690
16
90
700
600
18
81
620
540
* The capacities given are standard values that can vary depending on the composition of the feed water. We would be pleased to provide individual recommendations.
25
AquaAroma Crema Technology Decarbonisation
Cartridges for use in coffee machines with an integrated water tank (suction operation).
In the AquaAroma Crema filter cartridges, the water is sucked through the cartridge. To fix the cartridge in the tank, no additional brackets are required.
Various adapter solutions for retrofitting as well as a bracket for the cartridge in coffee machines are available.
26
AquaAroma Crema Cartridge cup dimensions (W / D / H)
42.8 / 106.9 / 60.8 mm
Water intake temperature
4 – 30 °C
Typical capacity – taking account of the local carbonate hardness Setting Aroma ring
Capacity* in litres
Cups 35 ml
Cups 150 ml
Level A
220
6,300
1,470
Level B
150
4,300
1,000
Level C
80
2,300
540
* The capacities given are standard values that can vary depending on the composition of the feed water. We would be pleased to provide individual recommendations.
27
Remote display
With the remote display, the customer can see all operating parameters at any time and has more flexibility in the location of the system
The remote display set increases the convenience of operation and ensures a better overview of the water filtration. Once mounted and connected to the filter system head, the remote unit remains on the wall with the display attached and offers clarity about consumption, settings and replacement dates.
28
Remote display Remote display (L / W / H) Cable length PURITY remote display Cable length remote display – machine Data interface transmission rate
138 / 48 / 103 mm approx. 2 m max. 10 m 9,600 Baud
Electrical supply
From display unit battery
Switching current
max. 50 m ADC
Degree of protection remote display (only for wall mounting) Screw size for cover
IPX 4 Torx T6
The remote display can only be used in connection with a filter that is equipped with measurement and display electronics.
29
FlowMeter 10 – 100 A
With the FlowMeter, consumption data and replacement dates can be displayed conveniently at eye level.
The FlowMeter increases the convenience of operation and ensures a better overview of the water filtration. Once installed, the device remains on the filter head and provides clarity about consumption and replacement dates. FlowMeter 10 – 100 A Display unit (L / W / H) 62 / 50 / 17 mm Flow range Flow deviation Operating pressure
Sensor (L / W / H) 81.5 / 43 / 46 mm 10 – 100 l / h ± 5 % max. 8 bar
Pressure loss with flow of 100 l / h
< 0.2 bar
Water intake temperature
4 – 30 °C
Ambient temperature operation / storage / transport Battery Degree of protection display unit (only for wall mounting) Degree of protection Sensor
0 – 60 °C Button cell 3 VDC, type CR2032 IPX 4 IPX 8
Cable length
max. 1.5 m
Inlet connection
G 3 / 8" nut
Outlet connection 30
G 3 / 8"
FlowMeter 100 – 700 A
FlowMeter 100 – 700 A Display unit (L / W / H) 62 / 50 / 17 mm
Sensor (L / W / H) 81 / 43 / 46 mm
Flow range
100 – 700 l / h
Flow deviation
± max. 5 %
Operating pressure
max. 8 bar
Pressure loss with flow of 100 l / h
< 0.2 bar
Water intake temperature
4 – 30 °C
Ambient temperature operation / storage / transport Battery Degree of protection display unit (only for wall mounting) Degree of protection Sensor Cable length Inlet connection Outlet connection
0 – 60 °C Button cell 3 VDC, type CR2032 IPX 4 IPX 8 max. 1.5 m G 3 / 4" with integrated O-ring washer G 3 / 4" nut 31
Bypass and capacity tables PURITY C50 Quell ST filter heads PURITY C 0 – 70 % with variable bypass Coffee/espresso machines and vending machines PURITY C50 Quell ST
Carbonate hardness in °dH
Recommended bypass setting in %
Capacity in litres
Cup 130 ml
Cup 150 ml
Cup 180 ml
4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35
70 70 70 60 50 50 40 40 30 30 30 30 30 30 30 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20
1,900 1,900 1,900 1,821 1,425 1,267 960 873 693 640 594 554 520 489 462 387 368 350 334 320 306 294 283 272 263 253 245 237 230 223 216 210
14,615 14,615 14,615 14,011 10,962 9,744 7,385 6,713 5,330 4,920 4,568 4,264 3,997 3,762 3,553 2,976 2,827 2,692 2,570 2,458 2,356 2,262 2,175 2,094 2,019 1,950 1,885 1,824 1,767 1,713 1,663 1,615
12,667 12,667 12,667 12,143 9,500 8,444 6,400 5,818 4,619 4,264 3,959 3,695 3,464 3,261 3,079 2,579 2,450 2,333 2,227 2,130 2,042 1,960 1,885 1,815 1,750 1,690 1,633 1,581 1,531 1,485 1,441 1,400
10,556 10,556 10,556 10,119 7,917 7,037 5,333 4,848 3,849 3,553 3,299 3,079 2,887 2,717 2,566 2,149 2,042 1,944 1,856 1,775 1,701 1,633 1,571 1,512 1,458 1,408 1,361 1,317 1,276 1,237 1,201 1,167
The capacities given have been tested and calculated on the basis of normal application and machine conditions. Due to external influences (e.g. variations in raw water quality and / or machine type), deviations from these results can occur. 32
PURITY C150 Quell ST filter heads PURITY C 0 – 70 % with variable bypass Coffee/espresso machines and vending machines PURITY C150 Quell ST
Carbonate hardness in °dH
Recommended bypass setting in %
Capacity in litres
Cup 130 ml
Cup 150 ml
Cup 180 ml
4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35
70 70 70 60 50 50 40 40 30 30 30 30 30 30 30 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20
4,766 4,766 4,766 4,569 3,574 3,177 2,408 2,189 1,738 1,604 1,490 1,390 1,303 1,227 1,159 970 922 878 838 802 768 737 709 683 658 636 615 595 576 559 542 527
36,660 36,660 36,660 35,144 27,495 24,440 18,523 16,839 13,369 12,340 11,459 10,695 10,026 9,437 8,912 7,464 7,091 6,753 6,446 6,166 5,909 5,673 5,455 5,252 5,065 4,890 4,727 4,575 4,432 4,297 4,171 4,052
31,772 31,772 31,772 30,458 23,829 21,181 16,053 14,594 11,586 10,695 9,931 9,269 8,690 8,178 7,724 6,469 6,145 5,853 5,587 5,344 5,121 4,916 4,727 4,552 4,390 4,238 4,097 3,965 3,841 3,724 3,615 3,512
26,477 26,477 26,477 25,382 19,858 17,651 13,378 12,162 9,655 8,912 8,276 7,724 7,241 6,815 6,437 5,391 5,121 4,877 4,656 4,453 4,268 4,097 3,939 3,793 3,658 3,532 3,414 3,304 3,201 3,104 3,012 2,926
The capacities given have been tested and calculated on the basis of normal application and machine conditions. Due to external influences (e.g. variations in raw water quality and / or machine type), deviations from these results can occur. 33
PURITY C300 Quell ST filter heads PURITY C 0 – 70 % with variable bypass Coffee/espresso machines and vending machines PURITY C300 Quell ST
Carbonate hardness in °dH
Recommended bypass setting in %
Capacity in litres
Cup 130 ml
Cup 150 ml
Cup 180 ml
4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35
70 70 70 60 50 50 40 40 30 30 30 30 30 30 30 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20
7,917 7,917 7,917 7,589 5,938 5,278 4,000 3,636 2,887 2,665 2,474 2,310 2,165 2,038 1,925 1,612 1,531 1,458 1,392 1,332 1,276 1,225 1,178 1,134 1,094 1,056 1,021 988 957 928 901 875
60,897 60,897 60,897 58,379 45,673 40,598 30,769 27,972 22,207 20,499 19,035 17,766 16,655 15,676 14,805 12,399 11,779 11,218 10,708 10,242 9,816 9,423 9,061 8,725 8,413 8,123 7,853 7,599 7,362 7,139 6,929 6,731
52,778 52,778 52,778 50,595 39,583 35,185 26,667 24,242 19,246 17,766 16,497 15,397 14,435 13,585 12,831 10,746 10,208 9,722 9,280 8,877 8,507 8,167 7,853 7,562 7,292 7,040 6,806 6,586 6,380 6,187 6,005 5,833
43,981 43,981 43,981 42,163 32,986 29,321 22,222 20,202 16,038 14,805 13,747 12,831 12,029 11,321 10,692 8,955 8,507 8,102 7,734 7,397 7,089 6,806 6,544 6,301 6,076 5,867 5,671 5,488 5,317 5,156 5,004 4,861
The capacities given have been tested and calculated on the basis of normal application and machine conditions. Due to external influences (e.g. variations in raw water quality and / or machine type), deviations from these results can occur. 34
PURITY C500 Quell ST filter heads PURITY C 0 – 70 % with variable bypass Coffee/espresso machines and vending machines PURITY C500 Quell ST
Carbonate hardness in °dH
Recommended bypass setting in %
Capacity in litres
Cup 130 ml
Cup 150 ml
Cup 180 ml
4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35
70 70 70 60 50 50 40 40 30 30 30 30 30 30 30 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20
13,458 13,458 13,458 12,902 10,094 8,972 6,800 6,182 4,908 4,530 4,207 3,926 3,681 3,464 3,272 2,740 2,603 2,479 2,366 2,264 2,169 2,083 2,002 1,928 1,859 1,795 1,735 1,679 1,627 1,578 1,531 1,488
103,526 103,526 103,526 99,245 77,644 69,017 52,308 47,552 37,752 34,848 32,359 30,201 28,314 26,648 25,168 21,078 20,024 19,071 18,204 17,412 16,687 16,019 15,403 14,833 14,303 13,810 13,349 12,919 12,515 12,136 11,779 11,442
89,722 89,722 89,722 86,012 67,292 59,815 45,333 41,212 32,718 30,201 28,044 26,175 24,539 23,095 21,812 18,268 17,354 16,528 15,777 15,091 14,462 13,883 13,349 12,855 12,396 11,968 11,569 11,196 10,846 10,518 10,208 9,917
74,769 74,769 74,769 71,677 56,076 49,846 37,778 34,343 27,265 25,168 23,370 21,812 20,449 19,246 18,177 15,223 14,462 13,773 13,147 12,575 12,052 11,569 11,124 10,712 10,330 9,974 9,641 9,330 9,039 8,765 8,507 8,264
The capacities given have been tested and calculated on the basis of normal application and machine conditions. Due to external influences (e.g. variations in raw water quality and / or machine type), deviations from these results can occur. 35
PURITY C1100 Quell ST filter heads PURITY C 0 – 70 % with variable bypass Coffee / espresso machines and vending machines PURITY C1100 Quell ST
Carbonate hardness in °dH
Recommended bypass setting in %
Capacity in litres
Cup 130 ml
Cup 150 ml
Cup 180 ml
4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35
70 70 70 60 50 50 40 40 30 30 30 30 30 30 30 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20
22,760 22,760 22,760 21,819 17,070 15,174 11,500 10,455 8,300 7,661 7,114 6,640 6,225 5,859 5,533 4,634 4,402 4,193 4,002 3,828 3,669 3,522 3,386 3,261 3,145 3,036 2,935 2,840 2,751 2,668 2,590 2,516
175,080 175,080 175,080 167,840 131,310 116,720 88,462 80,420 63,845 58,934 54,724 51,076 47,884 45,067 42,563 35,647 33,864 32,252 30,786 29,447 28,220 27,091 26,049 25,085 24,189 23,355 22,576 21,848 21,165 20,524 19,920 19,351
151,736 151,736 151,736 145,461 113,802 101,157 76,667 69,697 55,332 51,076 47,428 44,266 41,499 39,058 36,888 30,894 29,349 27,951 26,681 25,521 24,457 23,479 22,576 21,740 20,964 20,241 19,566 18,935 18,343 17,787 17,264 16,771
126,447 126,447 126,447 121,218 94,835 84,298 63,889 58,081 46,110 42,563 39,523 36,888 34,583 32,548 30,740 25,745 24,457 23,293 22,234 21,267 20.381 19,566 18,813 18,117 17,470 16,867 16,305 15,779 15,286 14,823 14,387 13,976
The capacities given have been tested and calculated on the basis of normal application and machine conditions. Due to external influences (e.g. variations in raw water quality and / or machine type), deviations from these results can occur. 36
PURITY C Quell ST filter heads PURITY C 0 – 70 % with variable bypass Combi steamers / conventional ovens Carbonate Recommen hardness ded bypass in °dH setting in % 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35
10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10
PURITY C50 PURITY C150 PURITY C300 PURITY C500 PURITY C1100 Quell ST Quell ST Quell ST Quell ST Quell ST Capacity in litres 1,100 1,100 1.100 943 825 733 660 600 550 508 471 440 413 388 367 347 330 314 300 287 275 264 254 244 236 228 220 213 206 200 194 189
2,759 2,759 2,759 2,365 2,069 1,839 1,656 1,505 1,380 1,273 1,183 1,104 1,035 974 920 871 828 788 753 720 690 662 637 613 591 571 552 534 517 502 487 473
4,583 4,583 4,583 3,929 3,438 3,056 2,750 2,500 2,292 2,115 1,964 1,833 1,719 1,618 1,528 1,447 1,375 1,310 1,250 1,196 1,146 1,100 1,058 1,019 982 948 917 887 859 833 809 786
7,792 7,792 7,792 6,679 5,844 5,194 4,675 4,250 3,896 3,596 3,339 3,117 2,922 2,750 2,597 2,461 2,338 2,226 2,125 2,033 1,948 1,870 1,798 1,731 1,670 1,612 1,558 1,508 1,461 1,417 1,375 1,336
13,177 13,177 13,177 11,295 9,883 8,785 7,906 7,188 6,589 6,082 5,647 5,271 4,941 4,651 4,392 4,161 3,953 3,765 3,594 3,438 3,294 3,163 3,041 2,928 2,824 2,726 2,635 2,550 2,471 2,396 2,325 2,259
The capacities given have been tested and calculated on the basis of normal application and machine conditions. Due to external influences (e.g. variations in raw water quality and / or machine type), deviations from these results can occur. 37
PURITY C Quell ST filter heads PURITY C with fixed bypass 0 % Combi steamers / conventional ovens Carbonate hardness in °dH 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35
PURITY C50 Quell ST
PURITY C150 Quell ST
1,000 1,000 1,000 857 750 667 600 545 500 462 429 400 375 353 333 316 300 286 273 261 250 240 231 222 214 207 200 194 188 182 176 171
2,508 2,508 2,508 2,150 1,881 1,672 1,505 1,368 1,254 1,158 1,075 1,003 941 885 836 792 753 717 684 654 627 602 579 557 538 519 502 485 470 456 443 430
PURITY C300 Quell ST
PURITY C500 Quell ST
PURITY C1100 Quell ST
7,083 7,083 7,083 6,071 5,313 4,722 4,250 3,864 3,542 3,269 3,036 2,833 2,656 2,500 2,361 2,237 2,125 2,024 1,932 1,848 1,771 1,700 1,635 1,574 1,518 1,466 1,417 1,371 1,328 1,288 1,250 1,214
11,979 11,979 11,979 10,268 8,984 7,986 7,188 6,534 5,990 5,529 5,134 4,792 4,492 4,228 3,993 3,783 3,594 3,423 3,267 3,125 2,995 2,875 2,764 2,662 2,567 2,478 2,396 2,319 2,246 2,178 2,114 2,054
Capacity in litres 4,167 4,167 4,167 3,571 3,125 2,778 2,500 2,273 2,083 1,923 1,786 1,667 1,563 1,471 1,389 1,316 1,250 1,190 1,136 1,087 1,042 1,000 962 926 893 862 833 806 781 758 735 714
The capacities given have been tested and calculated on the basis of normal application and machine conditions. Due to external influences (e.g. variations in raw water quality and / or machine type), deviations from these results can occur. 38
PURITY C Quell ST filter heads PURITY C with fixed bypass 30 % Coffee / espresso machines and vending machines Carbonate hardness in °dH 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35
PURITY C50 Quell ST
PURITY C150 Quell ST
1,386 1,386 1,386 1,188 1,039 924 831 756 693 640 594 554 520 489 462 438 416 396 378 361 346 333 320 308 297 287 277 268 260 252 245 238
3,476 3,476 3,476 2,979 2,607 2,317 2,086 1,896 1,738 1,604 1,490 1,390 1,303 1,227 1,159 1,098 1,043 993 948 907 869 834 802 772 745 719 695 673 652 632 613 596
PURITY C300 Quell ST
PURITY C500 Quell ST
PURITY C1100 Quell ST
9,815 9,815 9,815 8,413 7,362 6,544 5,889 5,354 4,908 4,530 4,207 3,926 3,681 3,464 3,272 3,100 2,945 2,804 2,677 2,561 2,454 2,356 2,265 2,181 2,103 2,031 1,963 1,900 1,840 1,785 1,732 1,683
16,600 16,600 16,600 14,228 12,450 11,066 9,960 9,054 8,300 7,661 7,114 6,640 6,225 5,859 5,533 5,242 4,980 4,743 4,527 4,330 4,150 3,984 3,831 3,689 3,557 3,434 3,320 3,213 3,112 3,018 2,929 2,846
Capacity in litres 5,774 5,774 5,774 4,949 4,330 3,849 3,464 3,149 2,887 2,665 2,474 2,310 2,165 2,038 1,925 1,823 1,732 1,650 1,575 1,506 1,443 1,386 1,332 1,283 1,237 1,195 1,155 1,118 1,083 1,050 1,019 990
The capacities given have been tested and calculated on the basis of normal application and machine conditions. Due to external influences (e.g. variations in raw water quality and / or machine type), deviations from these results can occur. 39
PURITY Quell ST Coffee / espresso machines and vending machines Carbonate hardness in °dH
Recommended bypass setting in %
4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 28 31 35
50 50 50 50 50 50 40 40 30 30 30 30 30 30 30 30 20 20 20 20 20 20 20 20 20
PURITY 450 Quell ST
PURITY 600 Quell ST
PURITY 1200 Quell ST
Capacity in litres 8,250 8,250 8,250 7,071 6,188 5,500 4,217 3,883 3,077 2,841 2,638 2,462 2,308 2,172 2,052 1,944 1,650 1,571 1,500 1,435 1,375 1,320 1,179 1,065 943
14,100 14,100 14,100 12,086 10,575 9,400 7,207 6,552 5,260 4,855 4,508 4,208 3,945 3,713 3,506 3,322 2,820 2,686 2,564 2,452 2,350 2,256 2,014 1,819 1,611
25,800 25,800 25,800 22,114 19,350 17,200 13,187 11,988 9,624 8,884 8,249 7,699 7,218 6,793 6,416 6,078 5,160 4,914 4,691 4,487 4,300 4,128 3,686 3,329 2,949
The capacities given have been tested and calculated on the basis of normal application and machine conditions. Due to external influences (e.g. variations in raw water quality and / or machine type), deviations from these results can occur.
40
PURITY Finest Coffee / espresso machines
Total hardness in °dH
Recommended bypass setting in %
4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
PURITY Finest 600
PURITY Finest 1200
Capacity in litres 7,333 7,333 7,333 6,286 5,500 4,889 4,400 4,000 3,667 3,385 3,143 2,933 2,750 2,588 2,444 2,316 2,200 2,095 2,000 1,913 1,833 1,760 1,692 1,630 1,571 1,517 1,467 1,419 1,375 1,333 1,294 1,257
13,583 13,583 13,583 11,643 10,188 9,056 8,150 7,409 6,792 6,269 5,821 5,433 5,094 4,794 4,528 4,289 4,075 3,881 3,705 3,543 3,396 3,260 3,135 3,019 2,911 2,810 2,717 2,629 2,547 2,470 2,397 2,329
The capacities given have been tested and calculated on the basis of normal application and machine conditions. Due to external influences (e.g. variations in raw water quality and / or machine type), deviations from these results can occur. 41
PURITY Finest C500 Coffee / espresso machines PURITY Finest C500
Total hardness in °dH
Recommended bypass setting in %
Capacity in litres
4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
5,690 5,690 5,690 4,877 4,268 3,793 3,414 3,104 2,845 2,626 2,439 2,276 2,134 2,008 1,897 1,797 1,707 1,626 1,552 1,484 1,423 1,366 1,313 1,264 1,219 1,177 1,138 1,101 1,067 1,035 1,004 975
The capacities given have been tested and calculated on the basis of normal application and machine conditions. Due to external influences (e.g. variations in raw water quality and / or machine type), deviations from these results can occur. 42
PURITY Steam Combi steamers / conventional ovens PURITY 450 Steam
PURITY 600 Steam
PURITY 1200 Steam
Capacity in litres
Carbonate hardness in °dH
0
1/ 2
3
0
1/ 2
3
0
1/ 2
3
4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 23 25 28 31 35
5,633 5,633 5,633 4,829 4,225 3,756 3,380 3,073 2,817 2,600 2,414 2,253 2,113 1,988 1,878 1,779 1,690 1,610 1,470 1,352 1,207 1,090 966
6,134 6,134 6,134 5,258 4,601 4,089 3,680 3,346 3,067 2,831 2,629 2,454 2,300 2,165 2,045 1,937 1,840 1,753 1,600 1,472 1,314 1,187 1,052
6,760 6,760 6,760 5,794 5,070 4,507 4,056 3,687 3,380 3,120 2,897 2,704 2,535 2,386 2,253 2,135 2,028 1,931 1,763 1,622 1,449 1,308 1,159
8,833 8,833 8,833 7,571 6,625 5,889 5,300 4,818 4,417 4,077 3,786 3,533 3,313 3,118 2,944 2,789 2,650 2,524 2,304 2,120 1,893 1,710 1,514
9,619 9,619 9,619 8,244 7,214 6,412 5,771 5,246 4,809 4,439 4,122 3,847 3,607 3,395 3,206 3,037 2,886 2,748 2,509 2,308 2,061 1,862 1,649
10,600 10,600 10,600 9,086 7,950 7,067 6,360 5,782 5,300 4,892 4,543 4,240 3,975 3,741 3,533 3,347 3,180 3,029 2,765 2,544 2,271 2,052 1,817
16,530 16,530 16,530 14,169 12,398 11,020 9,918 9,016 8,265 7,629 7,084 6,612 6,199 5,834 5,510 5,220 4,959 4,723 4,312 3,967 3,542 3,199 2,834
17,999 17,999 17,999 15,428 13,500 12,000 10,800 9,818 9,000 8,307 7,714 7,200 6,750 6,353 6,000 5,684 5,400 5,143 4,695 4,320 3,857 3,484 3,086
19,836 19,836 19,836 17,002 14,877 13,224 11,902 10,820 9,918 9,155 8,501 7,934 7,439 7,001 6,612 6,264 5,951 5,667 5,175 4,761 4,251 3,839 3,400
Bypass position
Bypass position
Bypass position
The capacities given have been tested and calculated on the basis of normal application and machine conditions. Due to external influences (e.g. variations in raw water quality and / or machine type), deviations from these results can occur.
43
PURITY Clean Dishwashers PURITY 1200 Clean Carbonate hardness in °dH 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 23 25 28 31 35
Bypass setting 0 %
Bypass setting 10 % Capacity in litres
30,000 24,000 20,000 17,143 15,000 13,333 12,000 10,909 10,000 9,231 8,571 8,000 7,500 7,059 6,667 6,316 6,000 5,714 5,217 4,800 4,286 3,871 3,429
32,667 26,133 21,778 18,667 16,333 14,519 13,067 11,879 10,889 10,051 9,333 8,711 8,167 7,686 7,259 6,877 6,533 6,222 5,681 5,227 4,667 4,215 3,733
The capacities given have been tested and calculated on the basis of normal application and machine conditions. Due to external influences (e.g. variations in raw water quality and / or machine type), deviations from these results can occur.
44
PURITY Clean Extra Dishwashers PURITY 1200 Clean Extra Total hardness in °dH 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 23 25 28 31 35
Bypass setting 0 %
Bypass setting 10 % Capacity in litres
12,500 10,000 8,333 7,143 6,250 5,556 5,000 4,545 4,167 3,846 3,571 3,333 3,125 2,941 2,778 2,632 2,500 2,381 2,174 2,000 1,786 1,613 1,429
13,611 10,889 9,074 7,778 6,806 6,049 5,444 4,949 4,537 4,188 3,889 3,630 3,403 3,203 3,025 2,865 2,722 2,593 2,367 2,178 1,944 1,756 1,556
The capacities given have been tested and calculated on the basis of normal application and machine conditions. Due to external influences (e.g. variations in raw water quality and / or machine type), deviations from these results can occur.
45
Certification
BRITA Professional strives to have all products certified worldwide. As well as the tests required by law, we also voluntarily subject ourselves to quality checks by independent institutions, with the goal of being able to supply you at all times with products that are a guarantee of safety and quality.
Germany Germany Safety checked, production monitored: “Plastic in drinking water / recommendations” test symbol issued by TÜV SÜD Product Service. ensure that no forbidden substances enter Provides a clear indication of the safety check and the drinking water. the monitoring of the production.
Great Britain and Northern Ireland Compliance with British Standard 6920 for materials in contact with drinking water.
46
Switzerland Approval for all point-of-use water filter systems – Schweizerischer Verein des Gas- und Wasserfaches (Swiss Association for the Gas and Water Professions).
Denmark Requirement for approval for products involving drinks and waste-water installations from the ETA – Danish board of European Technical Approval for Construction Products.
Russia and CIS countries Eurasian Customs Union conformity Russia / Belarus / Kazakhstan.
France Requirement for approval for harmlessness of all plastics and seals used / composition check of all materials used against French positive lists.
Norway Declaration of conformity in accordance with Norwegian production guidelines.
Australia AS / NZS 3497-1998 – Australian standard for drinking water treatment devices. Company annual production facility audits.
Italy Declaration of compliance pursuant to Regulation (EC) No 1935 / 2004 and DM 25 / 2012 on materials intended to come into contact with food.
02/15 blösch.partner PN: 1012934-004d
Headquarters BRITA GmbH Heinrich-Hertz-Straße 4 D – 65232 Taunusstein BRITA Water Filter Systems Ltd. BRITA House 9 Granville Way Bicester GB – Oxfordshire OX26 4JT tel.: +44 (0) 844 742 4990 fax: +44 (0) 844 742 4902
[email protected] www.brita.co.uk