Ww-fbcb23 (opti-core Pre-term.trunk Cable Assemblies Bulletin

   EMBED


Share

Transcript

Opti-Core ® Traditional Trunk Cable Assemblies Opti-Core ® Traditional Trunk Cable Assemblies allow for rapid deployment of high-density permanent links in a single assembly for data center applications requiring quick infrastructure deployment, such as main, horizontal, and zone distribution areas. These trunk cable assemblies optimize cabling routing requirements to ensure efficient use of pathway space and significantly reduce installation time and cost. They are built with traditional simplex and duplex connectivity (LC, SC, and ST), provide compatibility, flexibility, and system performance in all permanent link applications. Opti-Core® Traditional Trunk Cable Assemblies are factory terminated and tested to deliver verified optical performance and reliability for improved network integrity. 10Gig™ versions provide 10 Gb/s network performance up to 300 meters for OM3 and up to 550 meters for OM4 per IEEE 802.3ae 10 GbE standard while maintaining compatibility with legacy systems. Key Features Benefits Application specific designs Tailor configuration and breakout construction to application requirements to minimize waste, optimize cable management, speed deployment, and improve flexibility and manageability for lower installation costs Factory terminated Provides a quick-to-deploy, scalable solution to improve reliability and reduce installation time and cost 100% tested (test data supplied) Assures verified optical performance for improved network integrity Traditional connectors (LC, SC, and ST) High-density cable Provide design flexibility for all connectivity types throughout the data center Wide range of fiber cable configurations Support 10 Gb/s (OM3), (OM4), multimode (OM1 or OM2), and singlemode (OS1 and proposed OS2) permanent link elements in the data center to provide design flexibility for all connectivity types Uses pathway space more efficiently to improve manageability and reduce installation costs Te c h n i c a l I n f o r m a t i o n • Connectivity meets or exceeds TIA/EIA-568-B.3 and ISO/IEC 11801 performance requirements • Jacketed cable is compliant with UL1666 Optical Fiber Nonconductive Riser (OFNR), NFPA 262 Optical Fiber Nonconductive Plenum (OFNP), or IEC-60332 Low Smoke Zero Halogen (LSZH) flame rating • Insertion loss per mated pair: 0.10dB typical, 0.30dB max. (multimode); 0.25dB typical, 0.50dB max. (singlemode) • 10Gig™ laser optimized fiber is tested per IEEE 802.3ae 10 GbE to support network transmission speeds up to 10 Gb/s for link lengths up to 300 meters for OM3 and up to 550 meters for OM4 at 850nm w w w. p a n d u i t . c o m Opti-Core ® Traditional Trunk Cable Assemblies Tr u n k C a b l e A s s e m b l y D e t a i l Cable Assembly Length Pulling Eye Pulling Sock Breakout Legs (900µm Buffered or 2mm Upjacket Fiber) Connectors Connector Stagger^ Breakout Length: 39" (1m) Std.‡ Typical Cable End Detail Ordering Information Example description: Fiber Indoor Unarmored Cable, Plenum rated Multimode OM1 12-Fiber SC Simplex to SC Simplex 100 feet with Pulling Eye on End 'A, 2mm Upjacket Fiber Example: F S P 6 1 2 3 3 F 1 0 0 A 2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 – Fiber F - Fiber Cable 2 – Cable Type S = Indoor Unarmored Cable P = Indoor Armored Cable 3 – Flame/Smoke Rating R = OFNR P = OFNP L = LSZH 4 – Fiber Type 6 = 62.5/125µm Multimode OM1 5 = 50/125µm Multimode OM2 X = 300 meter reach 10Gig™ Multimode OM3 9 = Singlemode OS1/OS2 Z = 550 meter reach 10Gig™ Multimode OM4 (12 fiber only) 5 and 6 – Fiber Count 12, 24, 36, 48, 72, 96 or 1A = 144 fibers 7 (End ‘A’) and 8 (End ‘B’) – Connector Styles Select one style for each end, listing lower number first, number before letter, or alphabetically 1 = LC simplex, L = LC duplex, 2 = ST, 3 = SC simplex, S = SC duplex or N = Pigtail (End ‘B’ only) 9 – Unit of Measure F = Feet M = Meters 10, 11 and 12 – Length1 Length in Unit of Measure selected (up to 999 feet, 300m) 13 – End(s) Detail2 N = No Pulling Eye A = Pulling Eye on End ‘A’ B = Pulling Eye on End ‘B’ 14 – Breakout Construction Blank = 900µm Buffered Fiber (standard) 2 = 2mm Upjacket Fiber ^Connector stagger on pulling eye end only. ‡Standard breakout lengths up to 72-fibers are 39 inches (1m) from the final breakout. Breakout lengths for 96 and 144 fibers for 900µm buffered fiber are 44 inches (1.12m) for 96-fibers, and 51.5 inches (1.3m) for 144-fibers. Breakout lengths are 39 inches (1m) from the sub-unit for all 2mm upjacket fiber counts. Breakout length tolerances are +2 inches (5.1cm)/-0 for 900µm buffered fiber, and +3 inches (7.6cm)/-0 for 2mm upjacket fiber. Notes: 1. Available in lengths up to 999 feet (300m). Cable assembly lengths are measured as distance between the furthest connector tips. Length tolerance is +4 feet (1.2m)/-0. 2. Standard breakout is 900µm buffered fiber; 2mm upjacket breakout is also available. 3. For hybrid solutions (mixed fiber types), odd fiber counts (those not listed), other fiber types (those not listed) or special cable constructions/ratings/colors availability, consult Panduit. WORLDWIDE SUBSIDIARIES AND SALES OFFICES PANDUIT CANADA Markham, Ontario [email protected] Phone: 800.777.3300 PANDUIT EUROPE LTD. London, UK [email protected] Phone: 44.20.8601.7200 PANDUIT SINGAPORE PTE. LTD. Republic of Singapore [email protected] Phone: 65.6305.7575 PANDUIT JAPAN Tokyo, Japan [email protected] Phone: 81.3.6863.6000 PANDUIT LATIN AMERICA Guadalajara, Mexico [email protected] Phone: 52.33.3777.6000 PANDUIT AUSTRALIA PTY. LTD. Victoria, Australia [email protected] Phone: 61.3.9794.9020 For a copy of Panduit product warranties, log on to www.panduit.com/warranty For more information Visit us at www.panduit.com Contact Customer Service by email: [email protected] or by phone: 800.777.3300 and reference FBCB23 ©2011 Panduit Corp. ALL RIGHTS RESERVED. Product Bulletin Number WW-FBCB23 2/2011