MC-SFP-10km www.lynnelec.com 1310 nm Single-mode Transceiver, 10.5dB margin Small Form Pluggable (SFP), 3.3 V 1.0625Gbd Fiber Channel/1.25 Gigabit Ethernet Features  Compliant with IEEE802.3z Gigabit Ethernet Standard  Compliant with Fiber Channel 100-SM-LC-L standard  Industry standard small form pluggable (SFP) package  Duplex LC connector  Differential LVPECL inputs and outputs  Single power supply 3.3V  TTL signal detect indicator  Hot Pluggable  Class 1 laser product complies with EN 60825-1  RoHS compliant Application  Distributed multi-processing  Switch to switch interface  High speed I/O for file server  Bus extension application  Channel extender, data storage Ordering Information PART NUMBER MC-SFP-10Km INPUT/OUTPUT AC/AC Absolute Maximum Ratings PARAMETER Storage Temperature Supply Voltage Input Voltage Output Current Operating Current SIGNAL DETECT TTL SYMBOL TS Vcc VIN Io IOP MIN 40 0.5 0.5 ----- VOLTAGE 3.3V MAX 85 6.0 Vcc 50 400 TEC Opitx Solutions Division of Lynn Electronics Corp. 154 Railroad Drive • Ivyland, PA. 18974 TEMPERATURE 0°C to 70 °C UNITS °C V V mA mA NOTE MC-SFP-10km www.lynnelec.com 1310 nm Single-mode Transceiver, 10.5dB margin Small Form Pluggable (SFP), 3.3 V 1.0625Gbd Fiber Channel/1.25 Gigabit Ethernet Recommended Operating Conditions PARAMETER Ambient Operating Temperature Supply Voltage Supply Current SYMBOL TAMB Vcc ITX + IRX MIN 0 3.1 --- MAX 70 3.5 300 UNITS °C V mA NOTE Transmitter Electro-optical Characteristics Vcc = 3.1 V to 3.5 V, TA = 0 °C to 70 °C PARAMETER SYMBOL Output Optical Power Pout 9/125 μm fiber Extinction Ratio ER Center Wavelength C   Spectral Width (RMS) Rise/Fall Time, (2080%) Tr , f Relative Intensity Noise RIN Total Jitter TJ Output Eye Max. Pout TX-DISABLE Asserted POFF Differential Input Voltage VDIFF Transmit Fault Output-Low TX_FAULTL Transmit Fault Output-High TX_FAULTH TX_DISABLE Assert Time t_off TX_DISABLE Negate Time t_on Time to initialize, include reset of t_init TX_FAULT TX_FAULT from fault to assertion t_fault TX_DISABLE time to start reset t_reset MIN TYP. MAX UNITS NOTE 9.5 --- 3 dBm Average 9 1270 ----------0.65 0.0 2.4 ----- ----dB 1310 1355 nm --2.5 nm --260 ps --120 dB/Hz --227 ps Compliant with IEEE802.3z --35 dBm --2.0 V --0.5 V --VCC V μs --10 --1 ms --- --- 300 ms --10 ----- 100 --- μs μs TEC Opitx Solutions Division of Lynn Electronics Corp. 154 Railroad Drive • Ivyland, PA. 18974 MC-SFP-10km www.lynnelec.com 1310 nm Single-mode Transceiver, 10.5dB margin Small Form Pluggable (SFP), 3.3 V 1.0625Gbd Fiber Channel/1.25 Gigabit Ethernet Receiver Electro-optical Characteristics Vcc = 3.1 V to 3.5 V, TA = 0 °C to 70 °C PARAMETER SYMBOL MIN TYP. MAX UNITS NOTE Optical Input Power-maximum PIN 3 ----dBm BER < 1012 Optical Input Power-minimum 20 BER < 1012 PIN ----dBm (Sensitivity) Operating Center Wavelength C 1260 --1610 nm Optical Return Loss ORL 12 ----dB Receiver Electrical 3dB Upper ------1500 MHz Cutoff Frequency Signal Detect-Asserted ----20 dBm PA Signal Detect-Deasserted 31 ----dBm PD Stressed Receiver Sensitivity Note 1, 2 ----14.4 dBm Differential Output Voltage VDIFF 0.37 --2.0 V Data Output Rise, Fall Time T r, f ----0.35 ns (2080%) Receiver Loss of Signal Output RX_LOSL 0 --0.5 V Voltage-Low Receiver Loss of Signal Output RX_LOSH 2.4 --VCC V Voltage-High Receiver Loss of Signal Assert μs tA,RX_LOS ----100 Time (off to on) Receiver Loss of Signal Assert μs tD,RX_LOS ----100 Time (on to off) 12 Note 1: Measured with conformance test signal at TP3 for BER = 10 at the eye center. Note 2: Measured with a transmit signal having a 9 dB extinction ratio. If another extinction ratio is used, the Stressed receiver sensitivity should be corrected for the extinction ratio penalty. TEC Opitx Solutions Division of Lynn Electronics Corp. 154 Railroad Drive • Ivyland, PA. 18974 MC-SFP-10km 1310 nm Single-mode Transceiver, 10.5dB margin Small Form Pluggable (SFP), 3.3 V 1.0625Gbd Fiber Channel/1.25 Gigabit Ethernet www.lynnelec.com Block Diagram of Transceiver ELECTRICAL SUBASSEMBLY DATA DATA/ LD Driver & Fault Sense LASER TX_DISABLE TX_FAULT OPTICAL SUBASSEMBLIES (0) (1) MOD_DEF DUPLEX SC RECEPTACLE (2) DATA DATA/ POST-Amp & LOS Detect RREAMPLIFIER IC RX_LOS Photo Diode TOP VIEW (Label side) Transmitter Section The transmitter section consists of a 1310 nm InGaAsP laser in an eye safe optical subassembly (OSA) which mates to the fiber cable. The laser OSA is driven by a LD driver IC which converts differential input LVPECL logic signals into an analog laser driving current. TX_FAULT When sensing an improper power level in the laser driver, the SFP set this signal high and turns off the Laser. TX_FAULT can be reset with the TX_DISABLE line. The signal is in TTL level. TX_DISABLE The TX_DISABLE signal is high (TTL logic “1”) to turn off the laser output. The laser will turn on within 1ms when TX_DISABLE is low (TTL logic “0”). Receiver Section The receiver utilizes an InGaAs PIN photodiode mounted together with a trans-impedance preamplifier IC in an OSA. This OSA is connected to a circuit providing post-amplification quantization, and optical signal detection. Receive Loss (RX_LOS) The RX_LOS is high (logic “1”) when there is no incoming light from the companion transceiver. This signal is normally used by the system for the diagnostic purpose. The signal is operated in TTL level. TEC Opitx Solutions Division of Lynn Electronics Corp. 154 Railroad Drive • Ivyland, PA. 18974 MC-SFP-10km 1310 nm Single-mode Transceiver, 10.5dB margin Small Form Pluggable (SFP), 3.3 V 1.0625Gbd Fiber Channel/1.25 Gigabit Ethernet www.lynnelec.com Typical BER Performance of Receiver versus Input Optical Power Level 1.E-04 1.E-05 1.E-06 BER 1.E-07 1.E-08 1.E-09 1.E-10 1.E-11 1.E-12 -2.5 -2 -1.5 -1 -0.5 0 0.5 Relative Input Optical Power (dB) The figure shows the relationship between typical trade-off of BER and Relative Input Optical Power. Besides the required BER =1  1012 of the Gigabit Ethernet Physical Layer Standard, the transceiver can be operated at other BitError-Rate conditions. The Relative Input Optical Power in dB is referenced to the actual sensitivity of the device. For BER conditions better than 1  1012, more input signal is needed (+dB). Eye Diagram Transmitter Receiver Signal pattern: PRBS 7 Signal pattern: PRBS 7 Input Power: 20 dBm TEC Opitx Solutions Division of Lynn Electronics Corp. 154 Railroad Drive • Ivyland, PA. 18974 MC-SFP-10km www.lynnelec.com 1310 nm Single-mode Transceiver, 10.5dB margin Small Form Pluggable (SFP), 3.3 V 1.0625Gbd Fiber Channel/1.25 Gigabit Ethernet Dimensions DIMENSIONS ARE IN MILLIMETERS ALL DIMENSIONS ARE 0.2mm UNLESS OTHERWISE SPECIFIED Unit: mm TEC Opitx Solutions Division of Lynn Electronics Corp. 154 Railroad Drive • Ivyland, PA. 18974 MC-SFP-10km 1310 nm Single-mode Transceiver, 10.5dB margin Small Form Pluggable (SFP), 3.3 V 1.0625Gbd Fiber Channel/1.25 Gigabit Ethernet www.lynnelec.com SFP host board mechanical layout      L A S   L A S LEGEND A S S  1.PADS AND VIAS ARE CHASSIS GROUND 2.THROUGH HOLES, PLATING OPTIONAL 3.HATCHED AREA DENOTES COMPONENT AND TRACE KEEPOUT(EXCEPT CHASSIS GROUND) 4.AREA DENOTES COMPONENT KEEPOUT (TRACES ALLOWED) DIMENSIONS ARE IN MILLIMETERS A S S A S S Unit: mm TEC Opitx Solutions Division of Lynn Electronics Corp. 154 Railroad Drive • Ivyland, PA. 18974 MC-SFP-10km 1310 nm Single-mode Transceiver, 10.5dB margin Small Form Pluggable (SFP), 3.3 V 1.0625Gbd Fiber Channel/1.25 Gigabit Ethernet www.lynnelec.com Assembly drawing 1.7¡ Ó 0.9 3.5¡ Ó 0.3 41.73¡ Ó 0.5 PCB 9.8 MAX 11.0 REF. 15.25¡ 0Ó.1 10.4¡Ó0.1 CAGE ASSEMBLY 0.4¡Ó0.1 BELOW PCB 15.0 MAX BEZEL 16.25¡ Ó 0.1 MSA-SPECIFIED BEZEL PCB DIMENSIONS ARE IN MILLIMETERS Unit: mm TEC Opitx Solutions Division of Lynn Electronics Corp. 154 Railroad Drive • Ivyland, PA. 18974 MC-SFP-10km www.lynnelec.com 1310 nm Single-mode Transceiver, 10.5dB margin Small Form Pluggable (SFP), 3.3 V 1.0625Gbd Fiber Channel/1.25 Gigabit Ethernet Pin Assignment Pin-Out PIN 11 PIN 20 PIN 10 PIN 1 Pin 1 2 Signal Name TGND TX_FAULT Transmit Ground Transmit Fault Description 3 4 TX_DISABLE MOD_DEF (2) Transmit Disable SDA Serial Data Signal 5 6 7 MOD_DEF (1) MOD_DEF (0) RATE SELECT SCL Serial Clock Signal TTL Low Open Circuit 8 9 RX_LOS RGND Receiver Loss of Signal, TTL High, open collector Receiver Ground 10 11 RGND RGND Receiver Ground Receiver Ground 12 13 RX RX+ Receive Data Bar, Differential PECL, ac coupled Receive Data, Differential PECL, ac coupled 14 15 RGND VCCR Receiver Ground Receiver Power Supply 16 17 VCCT TGND Transmitter Power Supply Transmitter Ground 18 19 20 TX+ TX TGND Transmit Data, Differential PCEL, ac coupled Transmit Data Bar, Differential PCEL, ac coupled Transmitter Ground TEC Opitx Solutions Division of Lynn Electronics Corp. 154 Railroad Drive • Ivyland, PA. 18974 MC-SFP-10km www.lynnelec.com 1310 nm Single-mode Transceiver, 10.5dB margin Small Form Pluggable (SFP), 3.3 V 1.0625Gbd Fiber Channel/1.25 Gigabit Ethernet Eye Safety Mark The MC-SFP series single mode transceiver is a class 1 laser product. It complies with EN 60825-1 and FDA 21 CFR 1040.10 and 1040.11. In order to meet laser safety requirements the transceiver shall be operated within the Absolute Maximum Ratings. Required Mark Class 1 Laser Product Complies with 21 CFR 1040.10 and 1040.11 Caution All adjustments have been done at the factory before the shipment of the devices. No maintenance and user serviceable part is required. Tampering with and modifying the performance of the device will result in voided product warranty. Note : All information contained in this document is subject to change without notice. TEC Opitx Solutions Division of Lynn Electronics Corp. 154 Railroad Drive • Ivyland, PA. 18974