Preview only show first 10 pages with watermark. For full document please download

Www.telmor.pl Distribution Amplifiers Who-x29

   EMBED


Share

Transcript

Distribution amplifiers ISO 9001 CERTIFIED WHO-x29  IP64 RoHS Series of WHO-x29 amplifiers has been designed for professional multimedia cable TV networks which uses transmission in reverse path. Depending on output level there are two variants of amplifier. Usage of replaceable configuration modules allows wide choice of settings, according requirements. Basic variant of amplifier is not equipped with any configuration modules – they have to be ordered separately.  GaAs hybrid Power Doubler output stage.  High output level – 129dBuv  Easy configuration - universal JXP plug-in modules.  Active or passive plug-in return path module.  Input / Output double overvoltage protection.  Remote power supply transferable to any output.  Robust, shock resistant metal housing. Technical parameters may be changed without earlier notice GZT TELKOM-TELMOR SP. Z O.O, ul. Mickiewicza 5/7, 80-425 Gdańsk, Poland tel. +48 58 690-93-21, fax. +48 58 690-93-88, e-mail: [email protected] www.telmor.pl TECHNICAL SPECIFICATION FORWARD PATH WHO-829 WHO-929 Frequency range MHz Gain Gain characteristic flatness Max. output level: (DIN 45004B) Max. output level: - CTB @ 60dB for CENELEC (42 channels) with an interstage equalization ±6dB - CSO @ 60dB for CENELEC (42 channels) with an interstage equalization ±6dB Input attenuator Input equalizer Interstage attenuator dB dB dBuV 47-1000 55-1000 75-1000 87-1000 39 ±0,75 129 dBuV 114 dBuV 114 dB dB dB adjustable 0..20 plug-in JXP 0..20 adjustable 0..20 plug-in JXP 0..20 plug-in JXP 0..10 dB dB plug-in JMP, EQI -3, ,-6 -9, -12 -20 < 6,5 dB dB 20 20 @ 40MHz -1,5dB / oct. Interstage equalizer Input Output Test Point Noise factor Return loss at all Inputs / Outputs: - in the frequency range of 5 ÷ 40MHz - in the frequency range of 40 ÷ 1000MHz RETURN PATH Frequency range MHz Gain – measured at amplifier IN / OUT Gain characteristic flatness Max. output level - DIN 45004B Output attenuator Output equalizer Input Test Signal dB dB dBuV dB dB dB Type Noise factor (max.) OTHERS Operating voltage Power consumption (passive return path) Power supply method Current consumption at 30V AC / 90V AC Transfer of current from Input / Output Input connector (standard) Output connector (standard) Protection class Operational temperature range Weight Dimension (W x H x D) 5-30 5-42 5-55 5-65 -2,5 / 20 ±1 118 adjustable 0.. 20 adjustable 0.. 20 plug-in JXP 0..20 plug-in JXP 0..20 dB -20 Active module – EQA Passive Module – EQP (module for specification bandwidth) 6,0 V AC / Hz W / A A / / / °C kg mm 30..90 / 50-60 (sinusoid or trapezoid) 13,5 Remote from any Input / Output 0,8 5 / 0,25 7 5,8” or PG11 5,8” or PG11 IP64 -20…+60 1,4 196 x 134 x 84 / Technical parameters may be changed without earlier notice GZT TELKOM-TELMOR SP. Z O.O, ul. Mickiewicza 5/7, 80-425 Gdańsk, Poland tel. +48 58 690-93-21, fax. +48 58 690-93-88, e-mail: [email protected] www.telmor.pl