Www.zkteco.com

   EMBED


Share

Transcript

www.ZKTeco.com Safety Precautions What’s in a Box Product PIN Diagram LED indicators Product Dimensions Installation of Panel with Casing Wiring Legend Power Wiring Diagram FR1200 Connection Weigand Connection Exit button Connection Lock connection Door Sensor Connection Aux. Input Connection Aux. Output Connection Ethernet Connection RS485 Connection DIP switch settings Electrical Specifications Troubleshooting Specifications 1 02 04 06 06 07 08 09 10 11 12 12 13 13 15 15 16 17 18 19 20 21 1Safety Precautions The list below is to keep user’s safety and prevent any loss. Please read carefully before installation. 01 Do not install the device in an area subject to direct sun light, Humidity or dust 04 Be careful not to let liquid like water, drinks or chemicals leak inside the device. 02 03 Do not place the device next to heating equipments Do not place a magnet near the product. Magnetic objects such as magnet, CRT, TV, monitor or speaker may damage the device. 05 06 Clean the device often to remove dust on it 2 Do not let children touch the device without supervision. Safety Precautions The list below is to keep user’s safety and prevent any loss. Please read carefully before installation. 07 08 Do not drop the device. 10 Do not damage the device 09 Do not disassemble, repair or alter the device. 11 Do not use the device for any other purpose than specified. 12 In cleaning, do not splash water on the device but wipe it out with smooth cloth or towel. 3 Contact your nearest dealer in case of a trouble or problem. Product Contents Basic Contents Wall Mounting Screws – 2 pcs. Wall Plugs– 2 pcs. Screw Driver – 2 pcs. Software CD Inbio260 4 Surge Suppressing Diode– 4 pcs. InBio Installation Guide Product Contents Optional accessories Weigand Card Reader ZK4500 FP Enrollment reader Prox Card Card Enroller 5 FR1200 FP Reader K1-1 Exit Button Inbio Metal Case RS485 convertor Product PIN Diagram LED indicators SD Card Slot LINK LED Ethernet Port ACT LED Aux Input 1 LINK (Green) LED solid green indicates TCP/IP communication is normal ACT (Yellow) Flashing LED indicates data communication is in progress EXT RS485 (Yellow & Green) Flashing LED indicates data communication in progress PC RS485 (Yellow & Green) Flashing LED indicates data communication is in progress POWER (Red) Flashing LED indicates the panel is powered on. RUN (Green) Flashing LED indicates that panel is in normal working mode CARD (Yellow) Flashing LED indicates that the card is read by the panel. Aux Input 2 FR1200 Fingerprint Reader DIP Switch State Indictor PC RS485 Port Aux Output 1 #1 Door Exit Button #1 Door Card Reader1 Aux Output 2 #1 Door Sensor #1 Door Card Reader2 #1 Door Lock #2 Door Sensor #2 Door Lock Lock Power #2 Door Exit Button #2 Door Card Reader1 Inbio Power #2 Door Card Reader2 6 Product Dimension Inbio260 106mm (4.17in.) 106mm (4.17in.) 36mm (1.42in.) Dimensions(L*W*H):185.1× 106× 36(mm) 7.29× 4.17× 1.42(inches) 185.1mm (7.29in.) InBio-Casing 330mm (13.0in.) 330mm (13.0in.) 90.5mm (3.56in.) Dimensions(L*W*H): 400 *90.5*330(mm) 15.7× 13.0× 3.56(inches) 400mm (15.7in.) 7 Installation of Panel & Case Metal Case 8 Wire Legend Infrared sensors FR1200 Inbio-Case #1Exit Button #1Card Reader1 #2 Exit Switch #2 Card Reader1 DC Detector 12V DC Power 12V Network RS485 Convertor Floodlight Alarm Normally Close Lock Normally Open Lock Power Supply 9 Power wiring diagram Without Backup Battery AC Inbio260 110-220V AC Switching power supply With Backup Battery AC Inbio260 110-220V + Backup Battery - AC Switching power supply 10 FR1200 Connection 12V DC 12V DC #1 FR1200 DIP Switch Setting For FR1200 Device ID #2 FR1200 #3 FR1200 #4 FR1200 Important Notes 1. There are six DIP switches on the back of FR1200 , Switches 1-4 is for RS485 address , switch 5 is reserved , switch 6 is for reducing noise on long RS485 cable. 2. Set the odd number for IN reader, and the even number for OUT reader(for eg. For two readers for one door- the RS485 address 1 is for IN reader, RS485 address 2 is for OUT reader ) 3. If FR1200 is powered from Inbio260 panel ,the length of wire should be less than 100 meters or 330 ft. 4. The External RS485 interface can supply maximum 500mA current , The FR1200’s startup current is 240mA. So Inbio260 only can only power two FR1200s. 5. If the cable length is more than 200 meters or 600 ft , the number 6 switch should be ON as below Distance More than 200 meters 11 Weigand Connection Beeper Green LED Weigand D1 Weigand D0 GND DC+(6-14V) Weigand Card Reader Exit Button Connection 12V DC Power Supply DV12V(+) DV12V(-) BUT NO GND COM NC ZK ABK Exit Button Notice: separate power supply 12 K1-1 Exit Switch Lock Connection For Normally Open -Lock powered from panel power supply FR107 GND 12V DC Sensor Sensor GND 12V DC FR107 For Normally Closed -Lock powered from panel power supply 12V DC GND Sensor Sensor GND 12V DC 13 Lock Connection Switching Wet Contact to Dry Contact Important Notes: InBio is set to supply lock power by default from built-in power supply , If you want to use external power supply , you must take the following steps 1. Take apart the cover of inbio460 2. Select the desired lock relay and find its jumpers 3. Take off the jumpers and change to 4. Connect the lock as shown in the diagram below. Steps: Detach from Rail Inbio260 5 1 5 Changed Setting Lock Relay Remove Top Cover 5 1 Jumpers Terminals 1 5 1 Default Setting Connecting a Lock with External Power supply GND 12V DC FR107 SEN SEN GND 14 12V DC Auxiliary Input/Output Aux. Input Connection Smoke Detector 12V DC GND COM NO NC Aux. output Connection Alarm 12V DC GND COM NO NC 15 Ethernet Connection Important Notes: TCP/IP 1. Both 10Base-T and 100Base-T are supported 2. The cable length must be less than 100 meters or 330 ft. ZK4500 Enrollment reader CR10 Card Issuer 3. For more than 100 meters , please use HUB to amplify the signal The CR10 and ZK4500 are connected to the server using USB connection. Direct connection To connect Inbio260 with a PC directly, connect both devices with a straight network cable. As the Inbio260 supports auto MDI/MDIX , it is not necessary to use a crossover type cable. ZK4500 Enrollment reader CR10 Card Issuer 16 RS485 Connection #63 Inbio260 #1 Inbio260 Important Notes Do's and Dont's for RS 485 connection 1. RS485 communication wires should be a shielded or twisted pair cable. RS485 communication wires should be connected in a bus cascade instead of a star form, to achieve a better shielding effect by reducing signal reflection during communications. 2. A single 485 bus can be connected with 63 access control panels at the most, but preferably less than 32 panels should be connected. 3. To eliminate signal attenuation in communication cables and suppress interference, if the bus is longer than 200 meters, set the number 8 DIP switch to the ON position. This is equivalent to a parallel connection of one 120ohm resistance between the 485+ and 485- lines. Distance More than 200 meters #1 Inbio260 RS485RS485+ GND #* Inbio260 17 DIP Switch Setting Introduction RS485 Address 1. Number 1-6 are reserved to set the device number for RS485 communication. The code is binary, and the numbering starts from left to right. When the switch is set to ON position, it indicates 1 (on); when the switch is set downwards, it indicates 0 (off). For example, to set a device number 39=1+2+4+32, which corresponds to the binary code 111001, put number 1, 2, 3, and 6 to ON position, as illustrated below. 2. For more details, please check the table at the end of this document Restore factory setting Terminal Resistance 1. If you forget the inBio IP address or the device does not work normally, you can use the number 7 terminal to restore inbio260 to factory default settings. The parameters which gets reset are device IP address, communication password ,gateway ,subnet mask. 2. The switch is OFF by default. When it is moved upwards and downwards for three times within 10 seconds and finally returned to OFF position, the factory settings will be restored after the access control panel is restarted. 1. Number 8 is for setting the RS485 termination resistance. Putting the switch to ON position is equivalent to parallel connection of a 120ohm termination resistance between 485+ and 4852. As shown in diagram below, for more info please read RS485 connection important notes 1 times 2 times 3 times OFF 120ohm 18 Electrical Specification Min. Typ. Max. Notes 9.6 12 14.4 Use regulated DC power adaptor only Working power supply Voltage(V) Current(A) 2 Electronic lock relay output Switching voltage(V) 36V Switching Current(A) 2 Use regulated DC power adaptor only Auxiliary relay output Switching voltage(V) 36V Switching Current(A) 1.25 Use regulated DC power adaptor only Switch Aux. input VIH (V) TBD VIL (V) TBD Pull-up resistance (Ω) 4.7k The input ports are pulled up with 4.7k resistors WEIGAND Input Voltage(V) 10.8 12 Current(mA) 13.5 500 ZK Electronic lock Voltage(V) Current(mA) 10.8 12 13.2 500 19 Troubleshooting 1.     Fingerprint can not be read well or it takes too long. Check whether a finger or fingerprint sensor is stained with sweat, water, or dust Retry after cleaning the finger and fingerprint sensor with dry cloth. If a finger is way too dry, rub your finger on the palm and retry. Try to reset fingerprint sensor by pressing the reset button at the bottom of the reader 2. Fingerprint is matched but authorization keeps failing.  Check whether the user’ access is restricted.  Inquire with administrator whether the enrolled fingerprint has been deleted from the device for some reason. 3. How Many kinds of WEIGAND format can be supported.  The panel is set to read 26 bit by default.  However there are 9 other bit formats which can be selected from the software. In addition you can also define your custom bit format. 4.       How many verification modes can be support. Card Only Fingerprint Only Password Only Card plus fingerprint Card plus password Card or fingerprint 20 Reset Button Specification Communication RS485, Ethernet Baud Rate for RS485 9600-115200 baud Power Supply 12V DC, 3A Device Capacity Card capacity 30,000 ; Log events capacity 100,000 ; Finger capacity 3,000 LED Indicator Indication for communication, power, status and prox card Environment Operating Temp: 32-113 °F (0-45 °C) Number of doors controlled two door one way or two door two way Number of card readers supported 4 Number of FR1200 supported 4 FR1200 Sensor Fingerprint sensor 500dpi Optical / Optical sensor Types of readers supported 26-bit Weigand, others upon request Number of Inputs 6(2 Exit Device, 2Door Status, 2 AUX) Number of Outputs 4 (2- Form C relay for lock and 2- Form C relay for Aux output) Weight 7.8lbs (3.55kg) Enclosure Stainless Steel Mounting Wall Mount Dimensions (Bundle Only) 15.7in. × 3.56in.× 13.0in. 400mm(L) X 90.5mm(W) X 330mm(H) Dimensions ( Board Only) 8.89in.× 4.17in.× 1.42in. 226mm(L) X 106mm(W) X 36mm(H) CPU 32 bit 400MHz RAM 32MB Flash 128MB Certified 21 Operating Humidity: 20% to 80% PC485 Table Switch Setting Switch Setting Place Address Place Address 1 2 3 4 5 6 1 2 3 4 5 6 Address No. 1 2 4 8 16 32 Address No. 1 2 4 8 16 32 01 ON OFF OFF OFF OFF OFF 33 ON OFF OFF OFF OFF ON 02 OFF ON OFF OFF OFF OFF 34 OFF ON OFF OFF OFF ON 03 ON ON OFF OFF OFF OFF 35 ON ON OFF OFF OFF ON 04 OFF OFF ON OFF OFF OFF 36 OFF OFF ON OFF OFF ON 05 ON OFF ON OFF OFF OFF 37 ON OFF ON OFF OFF ON 06 OFF ON ON OFF OFF OFF 38 OFF ON ON OFF OFF ON 07 ON ON ON OFF OFF OFF 39 ON ON ON OFF OFF ON 08 OFF OFF OFF ON OFF OFF 40 OFF OFF OFF ON OFF ON 09 ON OFF OFF ON OFF OFF 41 ON OFF OFF ON OFF ON 10 OFF ON OFF ON OFF OFF 42 OFF ON OFF ON OFF ON 11 ON ON OFF ON OFF OFF 12 OFF OFF ON ON OFF OFF 43 ON ON OFF ON OFF ON 13 ON OFF ON ON OFF OFF 44 OFF OFF ON ON OFF ON 14 OFF ON ON ON OFF OFF 45 ON OFF ON ON OFF ON 15 ON ON ON ON OFF OFF 46 OFF ON ON ON OFF ON 16 OFF OFF OFF OFF ON OFF 47 ON ON ON ON OFF ON 17 ON OFF OFF OFF ON OFF 48 OFF OFF OFF OFF ON ON 49 ON OFF OFF OFF ON ON 50 OFF ON OFF OFF ON ON 51 ON ON OFF OFF ON ON 52 OFF OFF ON OFF ON ON 53 ON OFF ON OFF ON ON OFF ON ON OFF ON ON 18 19 20 21 22 OFF ON OFF ON OFF ON ON OFF OFF ON OFF OFF ON ON ON OFF OFF OFF OFF OFF ON ON ON ON ON OFF OFF OFF OFF OFF 23 ON ON ON OFF ON OFF 54 24 OFF OFF OFF ON ON OFF 55 ON ON ON OFF ON ON 25 ON OFF OFF ON ON OFF 56 OFF OFF OFF ON ON ON 26 OFF ON OFF ON ON OFF 57 ON OFF OFF ON ON ON OFF 58 OFF ON OFF ON ON ON ON ON OFF ON ON ON 27 ON ON OFF ON ON 28 OFF OFF ON ON ON OFF 59 29 ON OFF ON ON ON OFF 60 OFF OFF ON ON ON ON 30 OFF ON ON ON ON OFF 61 ON OFF ON ON ON ON 31 ON ON ON ON ON OFF 62 OFF ON ON ON ON ON 32 OFF OFF OFF OFF OFF ON 63 ON ON ON ON ON ON 22 Functions and specifications of the product are subject to change without notice due to quality enhancement or function update. For any inquiry for the product, please contact ZKTeco Inc . Copyright 2013 ZKTeco Inc. All right reserved. ZKTeco May, at any time and without notice , Make changes or improvements to the product and services offered and/or cease producing or commercializing them. ZK China : ZK Building, Wuhe Road, Gangtou, Bantian, Buji Town, Longgang District, Shenzhen China. Tel.: +86 755-89602345 [email protected] zkteco.com