X-SENS
SENSORS FOR X-AIRCONTROL ZONE MODULES AND OTHER EQUIPMENT Components for the measurement and recording of various quantities and conditions in systems for single room control and centralised control – such as X-AIRCONTROL Combined temperature and humidity sensor Dew point monitor Air quality sensor Motion detector Splitter
APPLICATION Application Type X-SENS sensors for use with X-AIRCONTROL and other control systems Can be connected to X-AIR-ZMO zone modules and X-AIR-ZMAS master modules Duct temperature sensor for supply and extract air Combined temperature and humidity sensor for extract air ducts Air quality sensor used as a duct sensor for measuring the concentration of volatile organic compounds (VOC) Air quality sensor for measuring the CO2 content in the room air and, when used as a room sensor, for measuring the humidity Dew point monitor for chilled ceilings etc. Motion detector (occupancy) Four-way splitter for the connection of four sensors or control panels (Modbus)
DESCRIPTION Variants TEMP-RH-EXH: Combined temperature and humidity sensor for extract air TEMP-PT1000: Duct temperature sensor (PT1000) VOC: Air quality sensor (VOC) CO2-RH: Combined CO2 and humidity sensor DEWPT: Dew point monitor PIR-SM: 180° motion detector PIR-FM: 360° motion detector SPLITTER: Four-way splitter for the connection of four sensors or control panels (Modbus)
Maintenance Maintenance-free as construction and materials are not subject to wear Checking and cleaning is recommended, in particular if the device is used in a room or in an extract air duct Regular cleaning from dust is recommended
TECHNISCHE INFORMATIE
Function, Technical data, Quick sizing, Specification text, Order code FUNCTION X-AIRCONTROL zone
① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨
Zone module Temperature sensor Air quality sensor Motion detector Humidity sensor Control panel Cooling, e.g. with an active chilled beam Heating, e.g. with a heating coil Volume flow control
SPECIFICATION TEXT Components for the measurement and recording of various quantities and conditions in systems for single room control and centralised control – such as X-AIRCONTROL
ORDER CODE
Type X-SENS
Variant Sensor
TEMP-RH-EXH
Combined temperature and humidity sensor for extract air
TEMP-PT1000
Duct temperature sensor (PT1000)
VOC
Air quality sensor (VOC)
CO2-RH
Combined CO2 and humidity sensor
DEWPT
Dew point monitor
PIR-SM
180° motion detector
PIR-FM
360° motion detector
SPLITTER
Four-way splitter for the connection of four sensors or control panels (Modbus)
Attachments, Dimensions and weight, Product details
X-SENS-TEMP-EXH
X-SENS-VOC
X-SENS-PIR-SM
Homepage > Producten > Regelsystemen > Demand-based room control with X-AIRCONTROL > Sensor systems > X-SENS
Home Contacten Imprint Leverings- en betalingsvoorwaarden Privacy Disclaimer 10-09-2017 © TROX Nederland B.V.
Homepage > Producten > Regelsystemen > Demand-based room control with X-AIRCONTROL > Sensor systems > X-SENS
ATTACHMENTS X-SENS-DEWPT
Installation details, Basic information and nomenclature INSTALLATION DETAILS Installation and commissioning X-SENS-TEMP-RH-EXH, X-SENS-TEMP-PT1000 Choose a suitable place for the sensor to mount it inside a duct Use the cable to connect the sensor to the zone module The zone module automatically recognises the sensor (plug and play)
Home Contacten Imprint Leverings- en betalingsvoorwaarden Privacy Disclaimer 10-09-2017 © TROX Nederland B.V.
Homepage > Producten > Regelsystemen > Demand-based room control with X-AIRCONTROL > Sensor systems > X-SENS
X-SENS-VOC Choose a suitable place for the air quality sensor to mount it inside a duct Use the cable to connect the sensor to the zone module The zone module automatically recognises the air quality sensor (plug and play)
X-SENS-CO2-RH Mount the lower part of the casing to a junction box or to the wall Connect the wires Attach the upper part of the casing The zone module automatically recognises the air quality sensor (plug and play)
X-SENS-PIR-SM Ensure that the installation location is suitable for the 180° operational range and for the detection range Wall installation: Preferably 1.1 to 2.2 m above the floor (4 m max.) Connect the wires Mount the lower part of the casing to a junction box or to the wall Put the cover on Configure the 'motion detector' function on the zone module
X-SENS-PIR-FM Ensure that the installation location is suitable for the 360° operational range and for the detection range Ceiling installation: Preferably 2.5 to 3.0 m above the floor (10 m max.) Connect the wires Fix the lower part of the casing to the ceiling Attach the upper part of the casing and the cover plate Configure the 'motion detector' function on the zone module
X-SENS-DEWPT The sensor casing should be fixed in the coldest area of the chilled surface (measurement location) The installation area may be flat or curved (chilled ceiling or circular duct) Fix the casing to the wall Connect the wires
Home Contacten Imprint Leverings- en betalingsvoorwaarden Privacy Disclaimer 10-09-2017 © TROX Nederland B.V.
Homepage > Producten > Regelsystemen > Demand-based room control with X-AIRCONTROL > Sensor systems > X-SENS
Configure the 'dew point monitor' function on the zone module
X-SENS-SPLITTER Mount the splitter onto a mounting rail Plug in the data cable to the zone module (RJ12 plug) Plug in the data cables to the sensors and actuators and to the control panel (RJ12) The maximum cable length is 30 m.
TROX Nederland B.V.
Online-Services
Service-Hotlines
Orderstatus (My TROX-NET)
TROX Nederland B.V.
Uw contactpersoon Online service contact formulier
Tel.: +31 (0)183 767 300 Fax : +31 (0)183 767 399 Contact
Aanvraag prijslijst TROX klimaat Levertijden: productietijd+2 werkdagen Veersteeg 11, 4212 LR Spijk Postbus 225, 4200 AE Gorinchem Tel.: +31 (0)183 767300 Fax.: +31 (0)183 767399 Email:
[email protected]
Home Contacten Imprint Leverings- en betalingsvoorwaarden Privacy Disclaimer 10-09-2017 © TROX Nederland B.V.