Transcript
9656_0235_05_XSeries_Spec Sheet_A4_Layout 1 3/1/12 12:35 PM Page 1
9656_0235_05_XSeries_Spec 9656_0235_05_XSeries_SpecSheet_A4_Layout Sheet_A4_Layout1 13/1/12 3/1/1212:35 12:35PM PMPage Page1 1
X Series
X X Series Series
Technical Specifications:
Technical Technical Specifications: Specifications:
Xtremely Small, Light, and Powerful
Xtremely XtremelySmall, Small,Light, Light,and andPowerful Powerful
TM
•
TMTM
At less than 12 pounds/6 kilograms, the X Series is about half the size and weight of other full-featured devices.
•
full-featured full-featureddevices. devices.
Its large, bright screen allows for simultaneous viewing of four traces, all 12 ECG leads, or static and dynamic 12-lead views on a “split screen”.
•
•
The device also incorporates the latest, most advanced and most complete monitoring capabilities,
®® ®® including including“gold “goldstandard” standard”Masimo Masimo rainbow rainbow SET SETPulse PulseCO-Oximetry CO-Oximetryand andWelch WelchAllyn’s Allyn’sRapid Rapid
NIBP technology to improve accuracy and reliability.
NIBP NIBPtechnology technologytotoimprove improveaccuracy accuracyand andreliability. reliability.
CPR Dashboard
TM
CPR CPRwith withConfidence Confidence
provides real-time numeric depth and rate values and has a CPR timer
that thatswitches switchestotoan anidle idletimer timerwhen whencompressions compressionsare arestopped. stopped.The Therelease releaseindicator indicatorand andthe the
perfusion performance indicator (PPI) also help maximize CPR performance.
perfusion perfusionperformance performanceindicator indicator(PPI) (PPI)also alsohelp helpmaximize maximizeCPR CPRperformance. performance.
See-Thru CPR® (unique to ZOLL®) helps minimize the duration of interruptions by filtering out artifact,
®® ®® • •See-Thru See-ThruCPR CPR (unique (uniquetotoZOLL ZOLL ) )helps helpsminimize minimizethe theduration durationofofinterruptions interruptionsbybyfiltering filteringout outartifact, artifact,
allowing allowingyou youtotosee seeorganized organizedunderlying underlyingrhythms rhythmsduring duringCPR. CPR. Unsurpassed Unsurpassed12-lead 12-leadData DataCollection Collectionand andCommunications CommunicationsCapabilities Capabilities
The X Series is the first monitor/defibrillator with integrated WiFi. Bluetooth and USB cellular ®
modem capabilities are standard as well.
•
TMTM • •CPR CPRDashboard Dashboard provides providesreal-time real-timenumeric numericdepth depthand andrate ratevalues valuesand andhas hasaaCPR CPRtimer timer
that switches to an idle timer when compressions are stopped. The release indicator and the
Unsurpassed 12-lead Data Collection and Communications Capabilities
•
• •The Thedevice devicealso alsoincorporates incorporatesthe thelatest, latest,most mostadvanced advancedand andmost mostcomplete completemonitoring monitoringcapabilities, capabilities,
including “gold standard” Masimo® rainbow® SET Pulse CO-Oximetry and Welch Allyn’s Rapid
allowing you to see organized underlying rhythms during CPR.
•
• •ItsItslarge, large,bright brightscreen screenallows allowsfor forsimultaneous simultaneousviewing viewingofoffour fourtraces, traces,allall12 12ECG ECGleads, leads,
ororstatic staticand anddynamic dynamic12-lead 12-leadviews viewson onaa“split “splitscreen” screen” ..
CPR with Confidence •
• •At Atless lessthan than12 12pounds/6 pounds/6kilograms, kilograms,the theX XSeries Seriesisisabout abouthalf halfthe thesize sizeand andweight weightofofother other
In conjunction with the new RescueNet® Link EMS communications system, patient data can be
®® • •The TheX XSeries Seriesisisthe thefirst firstmonitor/defibrillator monitor/defibrillatorwith withintegrated integratedWiFi. WiFi.Bluetooth Bluetooth and andUSB USBcellular cellular
modem modemcapabilities capabilitiesare arestandard standardasaswell. well. ®® • •InInconjunction conjunctionwith withthe thenew newRescueNet RescueNet Link LinkEMS EMScommunications communicationssystem, system,patient patientdata datacan canbe be
automatically uploaded and streamed* to remote displays in ambulances, hospitals, and
* *totoremote automatically automaticallyuploaded uploadedand andstreamed streamed remotedisplays displaysininambulances, ambulances,hospitals, hospitals,and and
communication centers while the rescuer cares for the patient on scene and in transit.
communication communicationcenters centerswhile whilethe therescuer rescuercares caresfor forthe thepatient patienton onscene sceneand andinintransit. transit.
The X Series acquires, stores, and transmits 12-leads to ZOLL's easy-to-use and economical RescueNet 12-Lead and RescueNet MedGate 12-Lead management systems.
• •The TheX XSeries Seriesacquires, acquires,stores, stores,and andtransmits transmits12-leads 12-leadstotoZOLL's ZOLL'seasy-to-use easy-to-useand andeconomical economical
RescueNet RescueNet12-Lead 12-Leadand andRescueNet RescueNetMedGate MedGate12-Lead 12-Leadmanagement managementsystems. systems.
9656_0235_05_XSeries_Spec Sheet_A4_Layout 1 3/1/12 12:35 PM Page 2
General Weight: 11.7 lbs. (5.3 kg) with battery and paper Dimensions: 8.9 in (22.6 cm) x 10.4 in (26.4 cm) x 7.9 in (20.1 cm) Enclosure Protection: Solid Foreign Object: IEC 60529, IP5X Water: IEC 60529, IPX5 Operating: Temperature: 0 to 50°C Humidity: 15 to 95% RH (non-condensing) Vibration: MIL-STD 810G, Method 514.6, 4.4.2 Procedure II EN ISO 9919 (per IEC 60068-2.64) EN 1789 for ambulance. RTCA/DO-160G (multiple helicopter frequencies) Shock: IEC 60068-2-27, 100g, 6 ms half sine Drop: EN 1789, 30-inch functional drop, IEC 60601-1, tested at 2 meters Altitude: -170 m to 4572 m (-557 feet to 15,000 feet) Monitor/Display Size: 6.5 in (16.56 cm) diagonal Input: 3-lead, 5-lead, or 12-lead patient cable, paddles, or multifunction electrodes Type: Color LCD, 640 x 480 pixels, 800 MCD Sweep Speed: 25 mm/sec or 50 mm/sec (user selectable) Lead Selections: Paddles (Pads), I, II, III, AVR, AVL, AVF, V1-6 Frequency Response: (user selectable) 0.67 – 20 Hz Limited mode 0.67 – 40 Hz Monitor mode 0.25 – 40 Hz Filtered diagnostic mode 0.05 – 150 Hz Diagnostic mode Defibrillator Waveform: Rectilinear Biphasic™ Energy Selections: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 15, 20, 30, 50, 70, 85, 100, 120, 150, 200 joules Energy Display: Display indicates selected and delivered energy Charge Time: Less than 7 seconds with a new, fully charged battery Charge Controls: Front panel and on apex paddle Pads/Paddles: Hands-free pads and external adult and pediatric paddles. Adult paddles slide off to expose pediatric paddles. Synchronized Mode: Synchronizes defibrillator pulse to patient’s R wave. “SYNC” message displayed on monitor and markers shown on both monitor and recorded ECG. Meets Clause 104 Pads of AAMI OneStep Pediatric Electrode enableDF80. the R Series to automatically adjust to proper pediatric energy levels.
Patient Modes User Selectable: Adult, Pediatric, Neonate. Automatically sets configurable defaults for alarm limits, defibrillation energy, and NIBP settings. Trends (on-screen) Tabular numeric format All parameters trended/viewable Trend Intervals: 1, 5, 10, 15, 30, 60 minutes Duration: 24 hours at 1-minute intervals Snapshots: Minimum of 32 (12 seconds of pre- and post-button press) Quick-access trend display via quickaccess button Memory Capacity A combination of 24 hours of trends at 1-minute intervals, 1000 time-stamped events, and 32 snapshots, including monitor, defibrillator, pacer, and treatment snapshots Pacer Type: External transcutaneous pacing Pulse Types: Rectilinear, constant current Pulse Width: 40 ms ± 2 ms Pacer Rate: 30 – 180 bpm ± 1.5% Output Current: 0 – 140 mA ± 5% or 5 mA, whichever is greater Modes: Demand and Fixed CPR CPR Feedback Technology See-Thru CPR®: Artifact filtering Real CPR Help® : Real-time depth and rate feedback CPR Dashboard™: Numeric readout of depth and rate, release indicator, perfusion performance indicator (PPI) ECG Cable Detection: Automatic 3-, 5-, 12-lead ECG Input: 3-lead cable, 5-lead cable, 12-lead cable, paddles, therapy cable Leads: I, II, III, AVR, AVL, AVF, V1 – V6 Heart Rate Range: 30 – 300 bpm Heart Rate Accuracy: ± 3 bpm or 3% Pacer Detection and Display ECG Sizes: 0.125, 0.25, 0.5, 1, 2, 4 cm/mV, and auto-ranging Sweep Speed: 25 mm/sec, 50 mm/sec Masimo® SET SpO2 Saturation Range: 1 – 100% Saturation Accuracy: Oxygen saturation during no-motion conditions: Adults, Pediatrics: 70 – 100%, ± 2 digits 0 – 69%, unspecified Neonates: 70 – 100%, ± 3 digits 0 – 69%, unspecified Oxygen saturation during motion conditions Adults, Pediatrics: 70 – 100%, ± 3 digits 0 – 69%, unspecified Neonates: 70 – 100%, ± 3 digits 0 – 69%, unspecified Oxygen saturation during low-perfusion conditions: Adults, Pediatrics 70 – 100%, ± 2 digits 0 – 69%, unspecified Neonates, 70 – 100%, ± 3 digits 0 – 69%, unspecified
9656_0235_05_XSeries_Spec 9656_0235_05_XSeries_SpecSheet_A4_Layout Sheet_A4_Layout1 13/1/12 3/1/1212:35 12:35PM PMPage Page2 2
Pulse Rate Range: 25 – 240 bpm Pulse rate during no-motion conditions: Adults, Pediatrics, Neonates: 25 – 240 ± 3 digits Pulse rate during motion conditions Adults, Pediatrics, Neonates: 25 – 240 ± 5 digits SpO2 Average time setting: 4, 8 (default), 16 seconds Masimo rainbow® SET SpCO® Range: 0 – 99% Accuracy: 1 – 40% ± 3 digits Masimo rainbow® SET SpMet® Range: 0 – 99% Accuracy: 1 – 15% ± 1 digits Non-Invasive Blood Pressure (NIBP) Smartcuf® and Sure BP® NIBP technology Measurement Intervals: Automatic 1-, 2-, 3-, 5-, 10-, 15-, 30-, 60-minute, and manual quick-action NIBP Start/Stop button TurboCuf: 5 min of repeated NIBP readings Display: Systolic, diastolic, mean. Viewable on-screen with large numerics. Cuff Overpressure Protection Typical Measurement Time: 30 – 45 sec (on deflation) 15 – 30 sec – Sure BP (on inflation) Standard Cuff Sizes: Neonate #1 – #5, Infant, Small Child, Small Adult, Adult Long, Large Adult, Thigh Default Cuff Inflation Pressure: Adults: 160 mmHg Pediatrics: 120 mmHg Neonates: 90 mmHg Pressure Measurement Range: Systolic: 20 – 260 mmHg Diastolic: 10 – 220 mmHg Mean: 13 – 230 mmHg Maximum Cuff Inflation Pressure: Adults: 270 mmHg Pediatrics: 170 mmHg Neonates: 130 mmHg EtCO2 Range: 0 – 150 mmHg Accuracy: 0 – 38: ± 2 mmHg 39 – 150: ± 5% + .08% mmHg >38 Respiration Range: 0 – 149 breaths per minute Respiration Rate Accuracy: 0 – 70 bpm ± 1 bpm 71 – 120 bpm ± 2 bpm 121 – 149 bpm ± 3 bpm Flow rate: 50 ml/min -7.5 + 15 ml/min Typical response time: 2.9 seconds Maximum response time: 3.9 seconds Impedance Pneumography Displayed Data: Numeric breath rate, Impedance waveform Breath Rate Range: Adult, Pediatric: 2 to 150 breaths/minute. Neonates: 3 to 150 breaths/minute. Breath Rate Accuracy: 2% or ± 2, whichever is greater Displayed Breath Rate: Average of last 10 breath-to-breath rates
A D VA N C I N G R E S U S C I T A T I O N. T O D A Y. ® ZOLL Medical Corporation Worldwide Headquarters 269 Mill Road Chelmsford, MA 01824 978-421-9655 800-348-9011 www.zoll.com For subsidiary addresses and fax numbers, as well as other global locations, please go to www.zoll.com/contacts.
Leads: Lead I (RA – LA), Lead II (RA – LL) Sweep Speed: 3.13, 6.25, 12.5 mm/sec Alarm Settings: High, low, and no breath rate alarm Invasive Pressure Three Channels Pressure Range: -30 – 300 mmHg Pulse Rate Measurement Range: 25 – 250 bpm Formats: S/D, S/D (M), (M) user selectable User-Selectable Labels: P1, P2, P3, ABP, AO, ART, CVP, BAP, FAP, LAP, PAP, RAP, UAP, UVP, ICP Transducer Requirements: 5M µV/V/mmHg Zero Adjustment: ± 200 mmHg Numeric Pressure Accuracy: ± 2 mmHg or 2% reading, whichever is greater of reading, plus transducer error Transducer Connector: Standard 6-pin AAMI Temperature Two YSI 400/700 series-compatible channels Range: 0 – 50°C (32 – 122°F) Units: °C or °F Display: T1, T2, and Delta temp Accuracy: ± 0.1°C (± 0.06°F) from 10 – 50°C (50 – 122°F) ± 0.2°C (± 0.11°F) from 0 – 10°C (32 – 50°F) Printer Type: High-resolution thermal array Annotation: Time, date, ECG lead, ECG gain, heart rate, defibrillation, and pacing parameters and treatment summary events Paper Width: 80 mm Paper Speed: 25 mm/sec, 50 mm/sec Delay: 6 seconds Frequency Response: Automatically set to monitor’s frequency response Record Modes: Manual and automatic (user configurable) Print Option Single waveform or a combination up to 3, on alarm, snapshots, treatment summary report, and trend summary Battery Type: Rechargeable lithium-ion, 11.1 Vdc, 6.6 Ah, 73 Wh Capacity: With a new, fully charged battery operating at room temperature: At least 6 hours of continuous monitoring of ECG, SpO2, CO2, 3 invasive pressure channels, and 2 channels of temperature, with NIBP measurements every 15 minutes and 10 200-joule shocks. 300 shocks at 200 joules with fully charged new battery at room temperature. At least 3.5 hours pacing, with ECG, SPO2, CO2, three invasive pressures, temperature, NIBP every 15 minutes and pacing at 180 ppm, and 140 mA. AC Power Adapter: 100 – 240 VAC 50, 60 Hz, 2A 100 – 115 VAC 400Hz, 2A
General General 11.7 11.7 lbs.lbs. (5.3 (5.3 kg)kg) with with battery battery Weight: Weight: paper paper and and 8.98.9 in in (22.6 (22.6 cm)cm)x 10.4 x 10.4 in in Dimensions: Dimensions: (26.4 (26.4 cm)cm)x 7.9 x 7.9 in in (20.1 (20.1 cm)cm) Protection: Protection: Solid Solid Foreign Foreign Object: Object: Enclosure Enclosure 60529, 60529, IP5X IP5X IECIEC IECIEC 60529, 60529, IPX5 IPX5 Water: Water: Operating: Operating: Temperature: Temperature: 50°C 50°C 0 to 0 to 1515 to to 95% 95% RHRH Humidity: Humidity: (non-condensing) (non-condensing) MIL-STD MIL-STD 810G, 810G, Method Method 514.6, 514.6, Vibration: Vibration: Procedure Procedure II II 4.4.2 4.4.2 ISOISO 9919 9919 (per (per IECIEC 60068-2.64) 60068-2.64) ENEN ENEN 1789 1789 forfor ambulance. ambulance. RTCA/DO-160G RTCA/DO-160G helicopter helicopter frequencies) frequencies) (multiple (multiple IECIEC 60068-2-27, 60068-2-27, 100g, 100g, 6 ms 6 ms half half sine sine Shock: Shock: Drop: Drop: ENEN 1789, 1789, 30-inch 30-inch functional functional drop, drop, IECIEC 60601-1, 60601-1, tested tested at at 2 meters 2 meters -170 -170 mm to to 4572 4572 mm Altitude: Altitude: feet feet to to 15,000 15,000 feet) feet) (-557 (-557 Monitor/Display Monitor/Display Size: Size: 6.56.5 in in (16.56 (16.56 cm)cm) diagonal diagonal Input: Input: 3-lead, 3-lead, 5-lead, 5-lead, or or 12-lead 12-lead patient patient paddles, paddles, or or multifunction multifunction electrodes electrodes cable, cable, Color Color LCD, LCD, 640 640 x 480 x 480 pixels, pixels, Type: Type: 800 800 MCD MCD Speed: Speed: 2525 mm/sec mm/sec or or 5050 mm/sec mm/sec Sweep Sweep selectable) selectable) (user (user Lead Lead Selections: Selections: Paddles Paddles (Pads), (Pads), I, II, I, II, III,III, AVR, AVR, AVL, AVL, AVF, AVF, V1-6 V1-6 Response: Response: Frequency Frequency selectable) selectable) (user (user 0.67 0.67 – 20 – 20 HzHz Limited Limited mode mode 0.67 0.67 – 40 – 40 HzHz Monitor Monitor mode mode – 40 – 40 HzHz Filtered Filtered diagnostic diagnostic mode mode 0.25 0.25 0.05 0.05 – 150 – 150 HzHz Diagnostic Diagnostic mode mode Defibrillator Defibrillator Waveform: Waveform: Rectilinear Rectilinear Biphasic™ Biphasic™ Energy Energy Selections: Selections: 1, 1, 2, 2, 3, 3, 4, 4, 5, 5, 6, 6, 7, 7, 8, 8, 9, 9, 10,10, 15,15, 20,20, 30,30, 50,50, 70,70, 85,85, 100, 100, 120, 120, 150, 150, 200 200 joules joules Energy Energy Display: Display: Display Display indicates indicates selected selected and and delivered delivered energy energy Charge Charge Time: Time: Less Less than than 7 seconds 7 seconds with with aa new, new, fully fully charged charged battery battery Charge Charge Controls: Controls: Front Front panel panel and and onon apex apex paddle paddle Pads/Paddles: Pads/Paddles: Hands-free Hands-free pads pads and and external external adult adult and and pediatric pediatric paddles. paddles. Adult Adult paddles paddles slide slide offoff to to expose expose pediatric pediatric paddles. paddles. Synchronized Synchronized Mode: Mode: Synchronizes Synchronizes defibrillator defibrillator pulse pulse to to patient’s patient’s R wave. R wave. “SYNC” “SYNC” message message displayed displayed onon monitor monitor and and markers markers shown shown onon both both monitor monitor and and recorded recorded ECG. ECG. Meets Meets Clause Clause 104 104 of Pads of AAMI AAMI DF80. DF80. OneStep OneStep Pediatric Pediatric Electrode Electrode Pads enable enable the the R Series R Series to to automatically automatically adjust adjust to to proper proper pedipediatric atric energy energy levels. levels.
Modes Modes Patient Patient User User Selectable: Selectable: Adult, Adult, Pediatric, Pediatric, Neonate. Neonate. sets sets configurable configurable defaults defaults Automatically Automatically alarm alarm limits, limits, defibrillation defibrillation energy, energy, and and forfor settings. settings. NIBP NIBP (on-screen) (on-screen) Trends Trends Tabular Tabular numeric numeric format format parameters parameters trended/viewable trended/viewable AllAll Intervals: Intervals: 1, 1, 5, 5, 10,10, 15,15, 30,30, 6060 minutes minutes Trend Trend Duration: Duration: 2424 hours hours at at 1-minute 1-minute intervals intervals Snapshots: Snapshots: Minimum Minimum of of 3232 (12(12 seconds seconds prepreand and post-button post-button press) press) of of trend trend display display viavia quickquickQuick-access Quick-access access access button button Memory Memory Capacity Capacity of of 2424 hours hours of of trends trends at at A combination A combination intervals, intervals, 1000 1000 time-stamped time-stamped 1-minute 1-minute and and 3232 snapshots, snapshots, including including monitor, monitor, events, events, defibrillator, defibrillator, pacer, pacer, and and treatment treatment snapshots snapshots Pacer Pacer External External transcutaneous transcutaneous pacing pacing Type: Type: Types: Types: Rectilinear, Rectilinear, constant constant current current Pulse Pulse Pulse Pulse Width: Width: 4040 msms ± 2± ms 2 ms Pacer Pacer Rate: Rate: 3030 – 180 – 180 bpm bpm ± 1.5% ± 1.5% Current: Current: 0 –0 140 – 140 mAmA ± 5% ± 5% or or 5 mA, 5 mA, Output Output is is greater greater whichever whichever Modes: Modes: Demand Demand and and Fixed Fixed CPR CPR CPR CPR Feedback Feedback Technology Technology ®: ® CPR CPR Artifact filtering filtering See-Thru See-Thru : Artifact ® ® CPR CPR Help Help: Real-time depth depth and and rate rate Real Real : Real-time feedback feedback ™:™Numeric Dashboard Dashboard readout readout of of depth depth CPR CPR : Numeric rate, rate, release release indicator, indicator, perfusion perfusion and and performance performance indicator indicator (PPI) (PPI) ECG ECG Detection: Detection: Automatic Automatic 3-,3-, 5-,5-, Cable Cable 12-lead 12-lead ECG ECG Input: Input: 3-lead 3-lead cable, cable, 5-lead 5-lead cable, cable, cable, cable, paddles, paddles, therapy therapy cable cable 12-lead 12-lead Leads: Leads: I, II, I, II, III,III, AVR, AVR, AVL, AVL, AVF, AVF, V1V1 – V6 – V6 Heart Heart Rate Rate Range: Range: 3030 – 300 – 300 bpm bpm Heart Heart Rate Rate Accuracy: Accuracy: ± 3± bpm 3 bpm or or 3%3% Pacer Pacer Detection Detection and and Display Display ECG ECG Sizes: Sizes: 0.125, 0.125, 0.25, 0.25, 0.5, 0.5, 1, 1, 2, 2, 4 cm/mV, 4 cm/mV, and and auto-ranging auto-ranging Sweep Sweep Speed: Speed: 2525 mm/sec, mm/sec, 5050 mm/sec mm/sec ® SET ® SET Masimo Masimo SpO SpO 2 2 Saturation Saturation Range: Range: 1 –1 100% – 100% Saturation Saturation Accuracy: Accuracy: Oxygen Oxygen saturation saturation during during no-motion no-motion conditions: conditions: Adults, Adults, Pediatrics: Pediatrics: 7070 – 100%, – 100%, ± 2± digits 2 digits 0 –0 69%, – 69%, unspecified unspecified Neonates: Neonates: 7070 – 100%, – 100%, ± 3± digits 3 digits 0 –0 69%, – 69%, unspecified unspecified Oxygen Oxygen saturation saturation during during motion motion conditions conditions Adults, Adults, Pediatrics: Pediatrics: 7070 – 100%, – 100%, ± 3± digits 3 digits 0 –0 69%, – 69%, unspecified unspecified Neonates: Neonates: 7070 – 100%, – 100%, ± 3± digits 3 digits 0 –0 69%, – 69%, unspecified unspecified Oxygen Oxygen saturation saturation during during low-perfusion low-perfusion conditions: conditions: Adults, Adults, Pediatrics Pediatrics 7070 – 100%, – 100%, ± 2± digits 2 digits 0 –0 69%, – 69%, unspecified unspecified Neonates, Neonates, 7070 – 100%, – 100%, ± 3± digits 3 digits 0 –0 69%, – 69%, unspecified unspecified
Rate Rate Range: Range: 2525 – 240 – 240 bpm bpm Pulse Pulse Pulse Pulse rate rate during during no-motion no-motion conditions: conditions: Pediatrics, Pediatrics, Adults, Adults, 2525 – 240 – 240 ± 3± digits 3 digits Neonates: Neonates: rate rate during during motion motion conditions conditions Pulse Pulse Adults, Adults, Pediatrics, Pediatrics, 2525 – 240 – 240 ± 5± digits 5 digits Neonates: Neonates: SpO SpO time time setting: setting: Average 2 2Average 4, 4, 8 (default), 8 (default), 1616 seconds seconds ® SET ® SET ® ® Masimo Masimo rainbow rainbow SpCO SpCO Range: Range: 0 –0 99% – 99% 1 –1 40% – 40% ± 3± digits 3 digits Accuracy: Accuracy: ® SET ® SET ® ® rainbow rainbow SpMet SpMet Masimo Masimo 0 –0 99% – 99% Range: Range: Accuracy: Accuracy: 1 –1 15% – 15% ± 1± digits 1 digits
Non-Invasive Non-Invasive Blood Blood Pressure Pressure (NIBP) (NIBP) ® and ® and ® NIBP ® NIBP Sure Sure BPBP technology technology Smartcuf Smartcuf Intervals: Intervals: Automatic Automatic 1-,1-, 2-,2-, Measurement Measurement 5-,5-, 10-, 10-, 15-, 15-, 30-, 30-, 60-minute, 60-minute, and and manual manual 3-,3-, quick-action quick-action NIBP NIBP Start/Stop Start/Stop button button 5 min 5 min of of repeated repeated NIBP NIBP readings readings TurboCuf: TurboCuf: Systolic, Systolic, diastolic, diastolic, mean. mean. Viewable Viewable Display: Display: on-screen on-screen with with large large numerics. numerics. Cuff Cuff Overpressure Overpressure Protection Protection Measurement Measurement Time: Time: Typical Typical – 45 – 45 secsec (on(on deflation) deflation) 3030 1515 – 30 – 30 secsec – Sure – Sure BPBP (on(on inflation) inflation) Standard Standard Cuff Cuff Sizes: Sizes: Neonate Neonate #1#1 – #5, – #5, Small Small Child, Child, Small Small Adult, Adult, Adult Adult Long, Long, Infant, Infant, Adult, Adult, Thigh Thigh Large Large Default Default Cuff Cuff Inflation Inflation Pressure: Pressure: 160 160 mmHg mmHg Adults: Adults: 120 120 mmHg mmHg Pediatrics: Pediatrics: Neonates: Neonates: 9090 mmHg mmHg Pressure Pressure Measurement Measurement Range: Range: 2020 – 260 – 260 mmHg mmHg Systolic: Systolic: 1010 – 220 – 220 mmHg mmHg Diastolic: Diastolic: 1313 – 230 – 230 mmHg mmHg Mean: Mean: Cuff Cuff Inflation Inflation Pressure: Pressure: Maximum Maximum Adults: Adults: 270 270 mmHg mmHg Pediatrics: Pediatrics: 170 170 mmHg mmHg Neonates: Neonates: 130 130 mmHg mmHg EtCO EtCO 2 2 Range: Range: 0 –0 150 – 150 mmHg mmHg Accuracy: Accuracy: 0 –0 38: – 38: ± 2± mmHg 2 mmHg 3939 – 150: – 150: ± 5% ± 5% + .08% + .08% mmHg mmHg >38 >38 Respiration Respiration Range: Range: 0 –0 149 – 149 breaths breaths perper minute minute Respiration Respiration Rate Rate Accuracy: Accuracy: 0 –0 70 – 70 bpm bpm ± 1± bpm 1 bpm 7171 – 120 – 120 bpm bpm ± 2± bpm 2 bpm 121 121 – 149 – 149 bpm bpm ± 3± bpm 3 bpm Flow Flow rate: rate: 5050 ml/min ml/min -7.5 -7.5 + 15 + 15 ml/min ml/min Typical Typical response response time: time: 2.92.9 seconds seconds Maximum Maximum response response time: time: 3.93.9 seconds seconds Impedance Impedance Pneumography Pneumography Displayed Displayed Data: Data: Numeric Numeric breath breath rate, rate, Impedance Impedance waveform waveform Breath Breath Rate Rate Range: Range: Adult, Adult, Pediatric: Pediatric: 2 to 2 to 150 150 breaths/minute. breaths/minute. Neonates: Neonates: 3 to 3 to 150 150 breaths/minute. breaths/minute. Breath Breath Rate Rate Accuracy: Accuracy: 2%2% or or ± 2, ± 2, whichever whichever is is greater greater Displayed Displayed Breath Breath Rate: Rate: Average Average of of last last 1010 breath-to-breath breath-to-breath rates rates
A AD DV V A ANNC CI N I NGG R RE S E SU US SC CI TI A TA T IT O I ONN . . ® ® TO T OD DA AY.Y. *Some capabilities will be available in future releases of compatible software
Specifications subject to change without notice. © 2012 ZOLL Medical Corporation. “Advancing Resuscitation. Today.”, CPR Dashboard, Rectilinear Biphasic, Real CPR Help, RescueNet, See-Thru CPR, X Series, and ZOLL are trademarks or registered trademarks of ZOLL Medical Corporation in the United States and/or other countries. Propaq, Smartcuf, and Sure BP are registered trademarks of Welch Allyn. Masimo, Rainbow, SET, SpCO, and SpMet are trademarks or registered trademarks of Masimo Corporation. All other trademarks are the property of their respective owners. Printed in U.S.A. 021210 9656-0235-05
ZOLL ZOLL Medical Medical Corporation Corporation Worldwide Worldwide Headquarters Headquarters 269 269 Mill Mill Road Road Chelmsford, Chelmsford, MA MA 01824 01824 978-421-9655 978-421-9655 800-348-9011 800-348-9011 www.zoll.com www.zoll.com ForFor subsidiary subsidiary addresses addresses and and faxfax numbers, numbers, asas well well asas other other global global locations, locations, please please gogo to to www.zoll.com/contacts. www.zoll.com/contacts.
*Some *Some capabilities capabilities will will bebe available available in in future future releases releases of of compatible compatible software software
Specifications Specifications subject subject to change to change without without notice. notice. ©© 2012 2012 ZOLL ZOLL Medical Medical Corporation. Corporation. “Advancing “Advancing Resuscitation. Resuscitation. Today.”, Today.”, CPRCPR Dashboard, Dashboard, Rectilinear Rectilinear Biphasic, Biphasic, Real Real CPRCPR Help, Help, RescueNet, RescueNet, See-Thru See-Thru CPR, CPR, X Series, X Series, andand ZOLL ZOLL areare trademarks trademarks or registered or registered trademarks trademarks of ZOLL of ZOLL Medical Medical Corporation Corporation in in thethe United United States States and/or and/or other other countries. countries. Propaq, Propaq, Smartcuf, Smartcuf, andand Sure Sure BP BP areare registered registered trademarks trademarks of Welch of Welch Allyn. Allyn. Masimo, Masimo, Rainbow, Rainbow, SET, SET, SpCO, SpCO, andand SpMet SpMet areare trademarks trademarks or registered or registered trademarks trademarks of Masimo of Masimo Corporation. Corporation. AllAll other other trademarks trademarks areare thethe property property of their of their respective respective owners. owners. Printed Printed in U.S.A. in U.S.A.021210 0212109656-0235-05 9656-0235-05
Lead Lead I (RA I (RA – LA), – LA), Lead Lead II (RA II (RA – LL) – LL) Leads: Leads: Sweep Sweep Speed: Speed: 3.13, 3.13, 6.25, 6.25, 12.5 12.5 mm/sec mm/sec Settings: Settings: High, High, low, low, and and nono breath breath Alarm Alarm alarm alarm rate rate Pressure Pressure Invasive Invasive Channels Channels Three Three Pressure Pressure Range: Range: -30-30 – 300 – 300 mmHg mmHg Rate Rate Measurement Measurement Range: Range: Pulse Pulse – 250 – 250 bpm bpm 2525 Formats: Formats: S/D, S/D, S/D S/D (M), (M), (M)(M) user user selectable selectable User-Selectable User-Selectable Labels: Labels: P1,P1, P2,P2, P3,P3, ABP, ABP, ART, ART, CVP, CVP, BAP, BAP, FAP, FAP, LAP, LAP, PAP, PAP, RAP, RAP, UAP, UAP, AO, AO, ICPICP UVP, UVP, Transducer Transducer Requirements: Requirements: µV/V/mmHg 5M5MµV/V/mmHg Adjustment: Adjustment: ± 200 ± 200 mmHg mmHg Zero Zero Pressure Pressure Accuracy: Accuracy: ± 2± mmHg 2 mmHg or or Numeric Numeric 2%2% reading, reading, whichever whichever is is greater greater of of reading, reading, transducer transducer error error plus plus Connector: Connector: Standard Standard 6-pin 6-pin Transducer Transducer AAMI AAMI Temperature Temperature Two Two YSIYSI 400/700 400/700 series-compatible series-compatible channels channels 0 –0 50°C – 50°C (32(32 – 122°F) – 122°F) Range: Range: °C°C or or °F°F Units: Units: Display: Display: T1,T1, T2,T2, and and Delta Delta temp temp Accuracy: Accuracy: ± 0.1°C ± 0.1°C(± (± 0.06°F) 0.06°F) from from 1010 – 50°C – 50°C – 122°F) – 122°F) ± 0.2°C ± 0.2°C (± (± 0.11°F) 0.11°F) from from 0 –0 10°C – 10°C (50(50 – 50°F) – 50°F) (32(32 Printer Printer Type: Type: High-resolution High-resolution thermal thermal array array Time, Time, date, date, ECG ECG lead, lead, ECG ECG gain, gain, Annotation: Annotation: rate, rate, defibrillation, defibrillation, and and pacing pacing heart heart parameters parameters and and treatment treatment summary summary events events Paper Paper Width: Width: 8080 mm mm Speed: Speed: 2525 mm/sec, mm/sec, 5050 mm/sec mm/sec Paper Paper 6 seconds 6 seconds Delay: Delay: Response: Response: Automatically Automatically setset Frequency Frequency monitor’s monitor’s frequency frequency response response to to Record Record Modes: Modes: Manual Manual and and automatic automatic (user (user configurable) configurable) Print Print Option Option Single Single waveform waveform or or a combinaa combination tion upup to to 3, 3, onon alarm, alarm, snapshots, snapshots, treatment treatment summary summary report, report, and and trend trend summary summary Battery Battery Type: Type: Rechargeable Rechargeable lithium-ion, lithium-ion, 11.1 11.1 Vdc, Vdc, 6.66.6 Ah,Ah, 7373 WhWh Capacity: Capacity: With With a new, a new, fully fully charged charged battery battery operating operating at at room room temperature: temperature: AtAt least least 6 hours 6 hours of of continuous continuous monitoring monitoring of of ECG, ECG, SpO SpO 2, CO 2, CO 2, 2, 3 invasive 3 invasive pressure pressure channels, channels, and and 2 channels 2 channels of of temperature, temperature, with with NIBP NIBP measurements measurements every every 1515 minutes minutes and and 1010 200-joule 200-joule shocks. shocks. 300 300 shocks shocks at at 200 200 joules joules with with fully fully charged charged new new battery battery at at room room temperature. temperature. AtAt least least 3.53.5 hours hours pacing, pacing, with with ECG, ECG, SPO SPO invasive invasive 2, CO 2, CO 2, three 2, three pressures, pressures, temperature, temperature, NIBP NIBP every every 1515 minutes minutes and and pacing pacing at at 180 180 ppm, ppm, and and 140 140 mA. mA. ACAC Power Power Adapter: Adapter: 100 100 – 240 – 240 VAC VAC 50,50, 6060 Hz,Hz, 2A2A 100 100 – 115 – 115 VAC VAC 400Hz, 400Hz, 2A2A