Preview only show first 10 pages with watermark. For full document please download

X632 Model V800acm Light-duty Adjustable Ceiling Mount

   EMBED


Share

Transcript

X632 MODEL V800ACM LIGHT-DUTY ADJUSTABLE CEILING MOUNT Copyright © 2000 Vicon Industries Inc. All rights reserved. Product specifications subject to change without notice. Vicon and its logo are registered trademarks of Vicon Industries Inc. VICON INDUSTRIES INC., 89 ARKAY DRIVE, HAUPPAUGE, NEW YORK 11788 TEL: 631-952-CCTV (2288) FAX: 631-951-CCTV (2288) TOLL FREE: 800-645-9116 24-Hour Technical Support: 800-34-VICON (800-348-4266) UK: 44/(0) 1489-566300 INFOFAX: 1-800-287-1207 WEB: www.vicon-cctv.com Vicon part no. 8006-8632-01-01 Rev 800 Section 7 Introduction The information in this manual covers the installation of Model V800ACM Light-Duty Adjustable Ceiling Mount. This unit should be installed by a qualified technician using approved materials in accordance with national, state and local codes. Read these instructions through completely before attempting installation. Model V800ACM Light-Duty Adjustable Ceiling Mount, constructed of light gray high-impact plastic, is designed to support camera/housing combinations weighing up to 7.5 pounds (3.4 kg). The mount is used for ceiling installation and the adjustable head features a locking knob for vertical movement and can be set for any normal camera angle. The body of the mount can be rotated a full 360° to adjust horizontal positioning. Installation Unpacking and Inspection All Vicon equipment is tested and inspected before leaving the factory. It is the carrier's responsibility to deliver the equipment in the same condition as it left the factory. Inspection For Visible Damage Immediately inspect the cartons upon delivery. Make a note of any visible damage on all copies of the carrier's freight bill. Make sure the carrier's agent (the person making the delivery) signs the note on all copies of the bill. If the agent does not have claim forms, contact the carrier's office. Inspection For Concealed Damage As soon as possible after delivery, unpack the unit and inspect it for concealed damage. Do not discard the carton or packing materials. If the unit is damaged, contact the carrier immediately and request forms for filing a damage claim. Make arrangements for a representative of the carrier to inspect the damaged equipment. If the equipment must be returned for repair, follow the Shipping Instructions at the end of this manual. Installation Procedure The V800ACM should be secured to studs or beams rather than directly to plaster or gypsum wallboard (sheetrock). If the mount is to be attached to a blind structure such as concrete block, use masonry screws with expandable plugs or the appropriate hardware with a pullout strength of no less than 150 lb each. Use steel fasteners in all installations. Note: Never use screws in the end grain of wood. Refer to Figure 1 as a guide for installation. 1. 2. Attach the base to the ceiling using two (2) number 8 or number 10 fasteners. Attach the camera/housing to the platform and adjust as required. Using the captive ¼-20 screw, tighten the adjusting knob only enough to securely fix the camera position. Do not overtighten. X632 Rev 800 V800ACM Ceiling Mount Introduction • 1 3. 4. Rotate the mount body for correct horizontal positioning. If readjusting the camera position in tilt is necessary, loosen the adjusting knob and reposition the camera. Do not force the camera. Figure 1 Outline Drawing/Installation Diagram Maintenance The V800ACM requires no maintenance. 2 • Maintenance X632 Rev 800 V800ACM Ceiling Mount Shipping Instructions Use the following procedure when returning a unit to the factory: 1. Call or write Vicon for a Return Authorization (R.A.) at one of the locations listed below. Record the name of the Vicon employee who issued the R.A. Vicon Industries Inc. 89 Arkay Drive Hauppauge, NY 11788 Phone: 631-952-CCTV (2288); Toll-Free: 1-800-645-9116; Fax: 631-951-CCTV (2288) For service or returns from countries in Europe, contact: Vicon Industries Ltd Brunel Way Fareham, PO15 5TX United Kingdom Phone: 44/(0)1489/566300; Fax: 44/(0)1489/566322 2. Attach a sheet of paper to the unit with the following information: a. Name and address of the company returning the unit b. Name of the Vicon employee who issued the R.A. c. R. A. number d. Brief description of the installation e. Complete description of the problem and circumstances under which it occurs f. Unit’s original date of purchase, if still under warranty 3. Pack the unit carefully. Use the original shipping carton or its equivalent for maximum protection. 4. Mark the R.A. number on the outside of the carton on the shipping label. X632 Rev 800 V800ACM Ceiling Mount Shipping Instructions • 1 Technical Information MECHANICAL Mounting: Two No. 8 or No. 10 screws. Type: Adjustable. Angular Movement: Vertical: ±90°. Horizontal: 360°. Application: Indoor. Load Rating: 7.5 lb (3.4 kg). Dimensions: Height: 6.2 in. (157 mm). Width: 3.5 in. (89 mm). Weight: 0.5 lb (0.2 kg). Construction: High-impact plastic. Finish: Light gray. X632 Rev 800 V800ACM Ceiling Mount Technical Information • 3