Preview only show first 10 pages with watermark. For full document please download

Xg2128 E1 Ber Tester Quick Start Manual

   EMBED


Share

Transcript

10/L1, 493 Riversdale Road Camberwell VIC 3124 – Australia P: 1300 468 469 | E: [email protected] | www.telecomtest.com.au XG2128 E1 BER Tester Quick Start Manual Front panel Tx(75 Ω) DC12V Input Jack Tx/Rx(120 Ω) Rx( 75 Ω) USB Port LCD Display LED Alarm and Status Indicators Functional Keyboard 2009-11-13 2 Side panel DC12V Input Jack USB Port 75 Ω (Rx) Unbalance Interface (L9) 2009-11-13 120 Ω Balance Interface (RJ45) 75 Ω (Tx) Unbalance Interface (L9) 3 Back panel Disassembly-proof Label Back Cover (put in battery) Serial Number Label 2009-11-13 4 LED Indicators 2009-11-13 5 Functional Keyboard Soft keys Setting, Result, Storage, Page up, page down, left&up, right&down key Other keys Single Error insert key, Start/Stop key 2009-11-13 Backlight, Power key 6 Connect cables  75 ohm unbalance Self-loop Test (L9) 2009-11-13 7 Connect cables  75 ohm unbalance Connect to device (L9 or BNC) Connect to device (L9 or BNC) 2009-11-13 8 Connect Cables  120 ohm balance Connect to device (Clamps Red: Tx Yellow: Rx) RJ45 2009-11-13 9 Operate E1 BER Tester  Press SETTING key and F1, F2, F3, F4, page up, down, left&up, right&down keys to revise the settings according to practical use Revise the settings like mode, line code, interface, framing, polarity, test pattern, etc. Press SETTING key and F1, F2, F3, F4 keys to revise settings according to the transmission line and the functions you require to test 2009-11-13 10 Operate E1 BER Tester Press F1, F2, F3 to switch between these 3 modes 2009-11-13 11 Operate E1 BER Tester  Press right&down key to the position as below: Press F1, F2 to switch between 75 Ω and 120 Ω 2009-11-13 12 Operate E1 BER Tester  Other settings in this page are revised in the same way as above, then press page down key: This shows page 2. Please revise the settings accordingly 2009-11-13 13 Operate E1 BER Tester  Press page down key: This shows page 3. Please revise the settings accordingly 2009-11-13 14 Operate E1 BER Tester  After settings, press START key to begin the test. Press START key to begin the test 2009-11-13 15 Operate E1 BER Tester This shows the test is started. Please click RESULT key to view the test results. No signal and shows in Yellow This LED lights up in green when starting test 2009-11-13 16 Operate E1 BER Tester  And then press RESULT key to view results These LED indicators also show the results if there is something wrong with the transmission line Press RESULT key to view the test results 2009-11-13 17 Operate E1 BER Tester Press F1, F2, F3, F4 key to view the results. 2009-11-13 18 Operate E1 BER Tester  Stop the test and save the records Click F1 and store the record in the tester. You can input the record name and save the record. 2009-11-13 19 Operate E1 BER Tester  Press OTHER key and then F1,F2,F3,F4 key to switch to PC Communication PC COMM 2009-11-13 20 Operate E1 BER Tester  In PC COMMUNICATION, set the USB port to ON state, upload the test records to PC Set the USB Port to ON state, and then connect tester to PC to upload the records Press F1, F2 key to set ON or OFF 2009-11-13 21 Operate E1 BER Tester Warning: In PC COMMUNICATATION, do not plug/unplug USB cable when the tester is on. 2009-11-13 22 View records on PC 2009-11-13 23 Print out records 2009-11-13 24 E1 BER Tester and accessories 2009-11-13 25