Transcript
XMC Solid State Memory Card Product Manual V1.0
2009-03-01
XMC 固态存储卡产品手册
Revision History Released Version
Date
Description
Beta1
2010-3-1
First Edition
Copyright
XMC 固态存储卡产品手册
参考 ANSI/VITA 47-2005, Environments, Design and Construction, Safety, and Quality for Plug-In Units VITA 48.0 (Draft) Mechanical Specifications for Microcomputers Using Enhanced Ruggedized Design Implementation (ERDI) IEEE STD 1386-2001, IEEE Standard for a Common Mezzanine Card Family: CMC ANSI/VITA 42-2005, Standard for XMC Card Family
XMC 固态存储卡产品手册
Contents Content ............................................................................ Error! Bookmark not defined. 1. Overview ....................................................................................................................... 5 2. Details ........................................................................................................................... 7 2.1 Parameters ................................................................................................................. 7 2.2 Functional Diagram .................................................................................................... 9 2.3 Function Instruction .................................................................................................... 7 2.4 Destruction Function................................................................................................. 11 2.4 Performance Table ................................................................................................... 11 3. Installation Instruction ................................................................................................. 13 3.1 Hardware Installation ................................................................................................ 13 3.2 X86 Platform BIOS RAID Configuration ................................................................... 14 3.3 Drivers Installation .................................................................................................... 16 3.4 Partition Configuration .............................................................................................. 16 3.5 Boot-up Configuration .............................................................................................. 17 4. Selection Guide .......................................................................................................... 18 4.1 Selection Table ......................................................................................................... 18 4.2 Optional Accessories ................................................................................................ 18 5、Caution ....................................................................... Error! Bookmark not defined.
XMC 固态存储卡产品手册
1. Overview Runcore Hurricane Series, the first generation of XMC solid state storage card, is generally in accordance with standard design VITA 42, using air cooling single card form, support two types of flash storage media – SLC and MLC, capacity range - 32GB~128GB (SLC)and 32GB~512GB(MLC)respectively. RCH-I-MU3 series XMC solid state storage card is made of PCIe-SATA bridge chip and two SATA solid-state memory cell, which both of them support RAID functionality, is also compatible with 1-Lane 2.5Gb / s PCIe Transfer Protocol. It provides two equal sets of SATA SSD storage spaces, each set of space’s write and read speed is up to 70MB/S. Using different operating system like Window, Linux and Vxworks, it then enable to do RAID0 (Stripe) and RAID1 (Mirror) mode of data transmission, which also provides the features such as superior performance and data security. Under the RAID0 (stripe) mode of data transition, its speed is up to 120MB/S.
The storage card is using the industrial level of SATA SSD controller, which provides a reliable ECC standard. Using flash as the storage medium, it has a quite working performance. The storage is using a “Loss balance algorithm” and “bad block management techniques” to ensure that the users can access accurately and consistently. Flash’s life is generally restricted by the number of times of accessing. In order to extend the life of the hard disk, one key self-destruction has integrated the benefits of “balance of loss of special algorithm” and “bad block management algorithm”, which ensure that the hard disk read and write cycles will cover all of the flash memory area. This algorithm can eliminate the repeated operation in one single memory area, which prevents the flash memory blocks in advance by “wear and tear”. Without power supplied, data in Runcore’s solid state disk storage can still maintain up to 10 years validity. Under any certain circumstances, stored data can extend the retention period and there would not be any sudden loss. Compared with the mechanical hard drive, RCH-I-HU3 series XMC solid state storage card does not use any mechanical parts. It has a superior performance, high reliability and
XMC 固态存储卡产品手册
low power consumption. It is able to adapt to a variety of flexible environment, which also has a broad application prospects in military aerospace defense.
XMC 固态存储卡产品手册
2. Details
2.1 Parameter Table
project
parameter Physical specification
Interface
XMC Pn5
Dimension WxL
74mmx149mm
Height
10mm
Weight
<100g
Identifiable SSD
2*SATA
Voltage
3.3V
Operating Power
<5.5W
Static Power
<1.2W Capacity SLC: 16GB~64GB1
SSD Capacity
MLC: 16GB~256GB SLC: 32GB~128GB2
Total Capacity
MLC: 32GB~512GB Performance Single disk Sustained
SLC 70MB/s
MLC 70MB/s
SLC 90MB/s
MLC 90MB/s
SLC 120MB/s
MLC 120MB/s
Write Speed Single Disk Sustained Read Speed RAID0 Sustained Write Speed
XMC 固态存储卡产品手册
RAID0 Sustained
SLC 120MB/s
MLC 120MB/s
Read Speed Compatibility Transfer protocol
PCI Express Base Specification Revision 1.0a 1-lane 2.5Gbit/s PCI Express
Driver
Driver support for Windows 98, Windows Millennium, Windows NT 4.0, Windows 2000, XP, Windows 2003, Netware 5.1, 6.0, 6.5, Red Hat Linux 8.0, 9.0, SuSE Linux 8.1, 8.2 and United Linux 1.0; Optional for Vxworks
Load type
Air cooled mezzanine cards with faceplate I/O compatible with Air cooled host card and Conduction cooled host card with removable rib Environment
Operating
(﹣20℃~﹢70℃) industrial level
Temperature
(﹣40℃~﹢85℃)
Humidity
10% - 90% RH
Altitude
12200m
Thermal
IEEE 1386-2001 (Air Cooled)
Standard
MIL-STD-810F\GJB150\GJB322A-98 Data security
ECC
12bit/512Byte
Life Reliability
10Year@500GB/day SLC 3Year@500GB/day MLC
Data security
One key self-destruction (speed 5GB/S)
RAID Configuration
Software RAID0、RAID1
MTBF
1,000,000 hours
XMC 固态存储卡产品手册
Standards
MIL-STD-810F\GJB150\GJB322A-98
*1、128GB Available @ Q3 2010 *2、256GB Available @ Q3 2010
2.2 Functional Diagram
XMC solid state storage card is made of two parts: PCIe Sata-RAID controller and two sets of SATA SSD. RAID controller PCIe industry protocol standard, is using the single channel transmission mode, and can be effectively compatible with a variety of computer platforms and operating systems. In addition, it can support these two kinds of configuration mode - both RAID0 and RAID1. These two sets of SATA SSD controller manage the 16 NAND Flash, compatible with SLC and MLC type of card with a maximum total capacity of up to 512GB, and provides a fast data elimination function keys.
XMC 固态存储卡产品手册
2.3 Function instruction
Thermal side Fixed hole
Destruction switch
LED2
3.3V key hole
LED1
LED3
LED4
Destruction key
Items
Function
Description
LED1
Memory Card
Read/Write Indicator light operation
Reader Instructions
XMC 固态存储卡产品手册
LED2
SSD0 status
Valid SSD0 for RAID configuration light status
indicator LED3
SSD0 status
Valid SSD1 for RAID configuration light status
indicator LED4
Destruction Status
If the destruction switch is ON, the indicator light will OFF
Indicator
and eliminate
Destruction
Self-Destruction
When the switch is ON, the destruction function is
Switch
Switch
enabled When the switch is OFF, the destruction function is disabled
Destruction
Destruction trigger
Key
button
Press the button to start the destruction function.
2.4 Destruction Function
The Destruction controller will trigger the destruction function, this process will quickly clear all of the data stored in the flash devices. This can be performed to different type of data even confidential data and will not cause any damage to the SSD. This method is simple and effective. Destruction speeds is up to 5GB / s, and can be applied to various fields with data security requirements. Destruction Mode Operation: 1、 Connect to a power supply, to make the board in a working condition; 2、 Switch ON, to enable the destruction function – LED4 will lit; 3、 Press the destruction key for 1 second, and hold it for about a second; 4、 As the memory card is in destruction state, it has a destruction rate of 5GB/s; 5、 When the destruction function is completed, SSD0 and SSD1 already in non-partitioned condition;
XMC 固态存储卡产品手册
2.4 Performance Table
XMC memory card, by making RAID0 configuration, has sustained read and write speeds of up to 140MB/s and 150MB/s. The following table shows a typical platform in the CPCIe sustained read and write 1。 SSD0 Read/
SSD1 Read /
RAID0 Read /
RAID1 Read /
Write Speed
Write Speed
Write Speed
Write Speed
64GB MLC
124/83
125/89
144/152
128/57
128GB MLC
122/89
122/89
148/144
125/58
256GB MLC
122/94
122/93
144/154
121/55
32GB SLC
123/99
123/100
149/145
122/59
64GB SLC
120/99
119/93
149/147
122/58
128GB SLC
123/114
123/114
147/160
126/60
Flash type
*1、The practical performance differs as the number of card and application platform varies
Test platform
NI PXIe-1062Q
Motherboard
NI PXIE-8130
Chipset
AMD Hammer DDR2 IML & nVIDIA nForce Pro3600
CPU
AMD TL-66
Memory
PC2-5300 DDR 1GB
HBA card
CPCIe HBA card
Operating System
WindowsXP
Hardware Configuration
Use BIOS for RAID configuration
Software Test Application
ATTO Bench32
Software configuration
Use BIOS for Raid configuration
XMC 固态存储卡产品手册
3. Installation guide
3.1 Hardware installation
1、Depending on the application requirements, select the XMC board, which must meet the standard of air cooling structure, or according to section 2.3 to provide heat in the cooling side of metal strips. CPCIe Carrier board as shown:
2、XMC card will be completely assembled in the right side direction of the carrier board, and fasten the screws.
XMC 固态存储卡产品手册
3、Installing the card into the computer system
3.2 X86 Platform BIOS RAID Configuration
In the X 86 platforms, you can manage and setup the RAID by using BIOS RAID tools. During system boot-up and loading of operating system, the following window will appear for about 5 seconds, and then press CTRL+S or F4 to enter BIOS RAID and configure the interface.
XMC 固态存储卡产品手册
RAID configuration tool interface is divided into four parts and a command line.
• In the main menu (upper left corner) of this window you can select what is going to be implemented: • Create RAID Set:will create a new RAID component or allocate new location to hard disk drive • Delete RAID Set:will delete the RAID component or remove the location from hard drive • Rebuild RAID 1 Set:after a replacement of a hard drive, re-create the RAID1 • Resolve Conflicts:after removing the hard disk, it will check for any errors in RAID
XMC 固态存储卡产品手册
configuration drive ports, and RAID components will restore the normal working condition. •Low Level Format:In removing a single hard drive does not format the hard drive nor allocate the remaining space. •Logical Drive Info:it will show only the actual allocation of the buffer space of each RAID configuration information, and do not allocate the SATA adapter on the physical drive. • Help section:In the upper right corner of the Help section, display context-sensitive help and status information. • Physical Drive:Lower-left corner displays connection to the SATA adapter on the hard disk type and the capacity. • Logical Drive:The lower right corner displays all hard drives connected to the controller • Shows RAID components and JBOD hard drive under the system BIOS • Spare hard disk, keeping the hard drive may lead to some conflict, and the BIOS may not recognize this as bad disk and it will be displayed at the bottom of this section. • Useful command can be found at the bottom of the command line: • Up and down arrows - to select a menu option or action • ESC - back to the previous menu • Enter – to select any highlighted word • Ctrl-E will exit configuration menu, depend on their operating condition.
3.3 Drivers Installation
Please select the CD-ROM Driver according to the corresponding operating system.
3.4 Partition Configuration
Based on RAID configuration and operating system, two completed SSD or two separate SSD can be identified after driver installation 1、 In Windows and Linux operating system, it will only identify BIOS RAID configuration but in the case of no BIOS RAID acknowledged in the RAID configuration, it will be acknowledged as two separate storage devices.
XMC 固态存储卡产品手册
2、 In the Vxworks system, it will be acknowledged as two separate storage devices. In the case of
two separate storage devices being acknowledged, it can use the software or
operating system to provide the tools to acknowledged RAID0 (Stripe) or RAID1 (Mirror) operation, to increase the performance or security. IN addition, it can be partitioned of formatted based on the application requirements after the equipments acknowledged it.
3.5 Boot-up Configuration
Memory card support the operating system to boot, the operating system installed can be used as guide for the memory card during the installation. 1. Computer boot-up, and enter the BIOS set-up.
2. Enter the BIOS boot option and set the memory card bootable device.
XMC 固态存储卡产品手册
4. Selection Guide 4.1 Selection Table
Model Products Type
Interface
Size
1st Generation RCH-I XMC Storage card
-M
Capacity
Medium
64 28 56
-M
U3 32 64 28
4.2 Optional Accessories
PCIe to XMC Adaptor
Model
RCB-XMC1-T2N
Standard
PCIe 1Lane
Software
None
Size
-S
Temp.
Destruction
C\I\W
I
XMC 固态存储卡产品手册
5、 、Caution
1、If the Destruction Function will not be used, place the switch into OFF-state to avoid it accidentally be switched.; 2、In inserting PMC carrier card to the memory card, please do not push it strong to avoid any damages on the connector; 3、