Transcript
XSM40 CAR
111 80
Power clamp compact body total protection 16 intergrated sensing side mounting central 6DIA H7 arm
33
20±0.02
33
7DIA
Maximum air pressure 8 BAR. Normal working 5 BAR Dry air is permissable Restricters must be used in conjunction with cylinder
91
±0.1
CAL
20±0.1
44 105°
Torque 85Nm at 5BAR Weight 2.3kg Arm options CA Center arm CAR Center arm right CAL Center arm left Sensing options NS No Sensing MC Magnetic Cylinder (for magnetic switch) ES1 Inductive Switches (1 outlet) Opening Angles 30°,45°,60°,75°,90°, 105°
22±0.1 25±0.2
27
49±0.05 55±0.05
A View arrow A
20±0.02 4
7.5±0.1
8N9
32±0.02 23±0.1
40
25
+0.1
275
6 H7 x 8
M6x10
See order guide for further information
M6 x 8
±0.1
216
35±0.1
1/ BSP 8
XSM240 50
90° 22±0.2
SANDFIELD ENGINEERING Co. Ltd. Sandy Lane, Stourport, Worcestershire, DY13 9LG. England. Tel: 01299 823158 Fax: 01299 827011
4
14/07/06
XSM25/40-HO 10 DIA
Power clamp, hand applied, compact body, total protection, intergrated sensing, side mounting.
Note:The handle is supplied loose and can be fitted on both sides of the clamp
Maximum air pressure 8 BAR Normal working 5 BAR Dry air is permissable Restricters must be used in conjunction with cylinder Weight: XSM25 XSM40
D
C 105°
1.7kg 2.7kg
Handle Options The handle is supplied loose and can be fitted on both sides of the clamp left (as shown) or the right. The handle is a fixed handle, it remains in the clamp position until the clamp is opened by air. It is possible to unclamp before air backup.
A°
B
E
5/3 Valve required for central positioning See order guide for further information
A
B
C
D
E
XSM25 HO
115°
31
132
90
26
XSM40 HO
113°
31
142
98
27
The handle can be adjusted through 360° to suit the desired operating position
SANDFIELD ENGINEERING Co. Ltd. Sandy Lane, Stourport, Worcestershire, DY13 9QB. England. Tel: 01299 823158 Fax: 01299 827011
5
14/07/06
XSM25/40-L
Locking Quadrant Power clamp, slim line body, total protection, intergrated sensing, side mounting. Locking Quadrant Retains clamp arm in open position without air supply. If the air supply is removed from the clamp when in the open position, for any reason: safety, circuit design, hand applied applications, supply failure, the clamp arm will not fall closed.
B
Right Hand Mounting shown (LR)
A
Typical application: Hand applied clamps with opening angles of less than 90 degrees(or when mounted at an angle) When the pneumatic valve moves into the neutral position to allow hand application. Options: 1. 25 & 40 bore clamps 2. Standard & hand applied clamps 3. Left Hand or Right Hand mounting See order guide for further information Left Hand Mounting (LL)
Note: Locking Quadrant is mounted on the opposite side to the handle
A XSM25 L
37.5
42
XSM40 L
44
44.5
SANDFIELD ENGINEERING Co. Ltd. Sandy Lane, Stourport, Worcestershire, DY13 9QB. England. Tel: 01299 823158 Fax: 01299 827011
6
B
07/06
XSM25/40 Order code guide for XSM25 & 40 power clamp products example showing the break down of the order code:
XSM
1
40
Clamp type
ES1
CA
HO
090
LL
Clamp Arm Type
Totally protected compact slimline with intergrated switching side mounting
CA Centre 'U' arm XSM40 only: CAR Right 'U' arm CAL Left 'U' arm
Clamp Arm Position 1 2
Hand Applied
Clamp arm horizontal Clamp arm vertical
HO Handle can be fitted fitted on the left or the right of the clamp as standard, without modification
Cylinder Diameter 25 Bore 40 Bore
Opening Angle
Ordering example: XSM140-ES1-CA-090 XSM
1 40 ES1 CA HO 090 LR
Totally protected slimline with intergrated switching side mounting Clamp arm horizontal 40 Bore Inductive switch (1 outlet) Centre arm Hand Applied 90° Opening Locking quadrant on right side of clamp
Sensing
XSM125 XSM225
30, 45, 60, 75, 90,105 30, 45, 60,75, 96
XSM140 XSM240
30, 45, 60, 75, 90,105 30, 45, 60,75, 90
NS No sensing MC Magnetic cylinder ES1 Inductive switch (1 outlet)
Locking Quadrant LL LR
SANDFIELD ENGINEERING Co. Ltd. Sandy Lane, Stourport, Worcestershire, DY13 9LG. England. Tel: 01299 823158 Fax: 01299 827011
7
Mounted left side Mounted right side
14/07/06