Preview only show first 10 pages with watermark. For full document please download

Xtralis Integrated Security

   EMBED


Share

Transcript

Xtralis Integrated Security S3000 RDCU 2 Reader / Door Control Unit Key Benefits • Full IP, with power-over-Ethernet (12 or 24 V, depending on the slot type) • Full system redundancy • Power/Control for two doors by one RDCU 2 with the 2-door interface plugin • Supports Wiegand readers or data and clock readers for two doors when using the 2-door PCB Description The RDCU 2 IP reader/door control unit is one of several network devices that make up the S3000 Access Control system, taking full advantage of the existing vantage of the IT network infrastructure and low cost structured cabling system (CAT5e or CAT6). • Connects with RS-485 readers when using the RS-485 bus • Plug-and-use technology • Spanning Tree Protocol The RDCU 2 is a single door controller with two Wiegand reader connections that allow for both read-in and read-out applications. All door functions are connected and powered utilising the RDCU’s PoE capability, including most door strikes and locking mechanisms. An optional relay is available for heavy duty locks and gate operators. • Internal fail safe control The RDCU 2 supports plug-and-use technology, Power-over-Ethernet, strong encrypted TCP/IP communication (SSL), automatic IP assignment (via LPU), and optional Li-polymer battery pack. • Mechanical tamper switch for the housing The S3000 access control system is fully interoperable with the Xtralis 3000 Series family of products, including the FastTrace 2/2E for video and audio recording and transmission, the V3500 for mass storage and archiving, and the V3001 for video wall applications. Xtralis Security Solution product family • SSL data encryption • IT network standards • Real Time Clock • Standalone mode: when RDCU 2 is unable to communicate with the LPU, it will fall back on its standalone mode and use its last known internal data for access control Xtralis Integrated Security S3000 RDCU 2 Reader / Door Control Unit Configuration Specifications DCU - Door Control Unit RDR - IP Card Reader IP Door control with SSL encryption plus door power/ control The only IP Card reader with SSL encryption on the market Operating temperature -10 °C to +55 °C Relative humidity 91 % non-condensing Dimensions PCB = 165 x 110 mm Housing = 303 x 205 x 60 mm Power supply unit 9–28 VDC (PoE: 12 or 24 VDC, depending on the RDCU usage) See RDCU 2 consumption Consumption PCB • Main PCB: max 150 mA (with 12 V, relays not active, without readers) • 2-door interface: negligible when relays not active • GPIO PCB: negligible when relays not active • GPIO Extension PCB: negligible when relays not active LAN connection 10/100 Mbps Flash memory 128 kB (1 Gbit) DDR2 memory 512 Mbit Add-on card With PCB option (for 2 doors) = 4 reader heads USB connection USB port available to upgrade ‘on the scene’ with a USB key Maximum lock(s) current max. 2 A (1 A per door) Relay contacts max. 28 VDC / 1 A Relay coil 5 VDC / 140 mW → 28 mA (12 mA @ 12 VDC) (PoE) RDR (PoE) RDR S3000 System Standard Switched Building Network supporting PoE and STP RDCU 2 (PoE) LPU - Local Processing Units (PoE) IP backbone providing centralised intelligence and dual network redundancy RDCU 2 - IP Reader/Door Control Unit For use with Wiegand Readers plus door power/control IOCU - Input/Output Control Unit IP I/O with 16 inputs and 8 relay outputs Block Diagram (Optional) Door 1 Door 2 Contact Contact (Optional) Request Request to Exit 1 to Exit 2 Built-in Tamper 12/24 VDC Out Controller 12/24 VDC In (Optional use PoE extractor) Lock 1 Lock 2 (Optional) Ethernet Wiegand Channel 0 Wiegand Channel 1 CPU 12 VDC (max 100 mA) For each reader Wiegand Channel 2 Wiegand Channel 3 TCP / IP SSL Interface Host Table Power to Readers & Door Strike Relay Output (Optional) Ordering Information RDCU 2 unit (1-door) 49840900 RDCU 2 unit including 2-door interface 49840910 PoE 12 V set 39544380 PoE 24 V set 39544390 RDCU 2 GPIO set 39544470 RDCU 2 GPIO extension set 39544490 www.xtralis.com UK and Europe +44 1442 242 330 D-A-CH +49 431 23284 1 The Americas +1 781 740 2223 Middle East +962 6 588 5622 Asia +86 21 5240 0077 Australia and New Zealand +61 3 9936 7000 The contents of this document are provided on an “as is” basis. No representation or warranty (either express or implied) is made as to the completeness, accuracy or reliability of the contents of this document. The manufacturer reserves the right to change designs or specifications without obligation and without further notice. Except as otherwise provided, all warranties, express or implied, including without limitation any implied warranties of merchantability and fitness for a particular purpose are expressly excluded. Xtralis, Xtralis logo, The Sooner You Know, VESDA, ICAM, ECO, OSID, HeiTel, ADPRO, IntrusionTrace, and LoiterTrace are trademarks and/or registered trademarks of Xtralis and/or its subsidiaries in the United States and/or other countries. Other brand names mentioned herein are for identification purposes only and may be trademarks of their respective holder(s). Your use of this document does not constitute or create a licence or any other right to use the name and/or trademark and/or label. This document is subject to copyright owned by Xtralis. You agree not to copy, communicate to the public, adapt, distribute, transfer, sell, modify or publish any contents of this document without the express prior written consent of Xtralis. Doc. no. 27702_01