Preview only show first 10 pages with watermark. For full document please download

X:\ufficio Tecnico\documentazione\secur 3\manuali

   EMBED


Share

Transcript

Securlift sagl Viale Serfontana 12 CH - 6834 Morbio Inferiore Switzerland Tel. +41 (0)91 682 7681 Fax +41 (0)91 682 6154 [email protected] www.securlift.com INDEX INTRODUCTION ................................................................................................................................................... 2 SYSTEM DESCRIPTION ......................................................................................................................................... 2 TECHNICAL SPECIFICATIONS ................................................................................................................................ 3 TOPOGRAPHIC DRAWINGS ................................................................................................................................. 5 CABINETS .......................................................................................................................................................... 13 INTERNAL LAYOUT ............................................................................................................................................ 19 PRELIMINARY TEST............................................................................................................................................ 20 INSULATION TEST INSTRUCTION ....................................................................................................................... 21 DZSM–DOOR ZONE SAFETY MODULE TEST INSTRUCTION ................................................................................. 22 EN-81 – A3 AMENDMENT .................................................................................................................................. 23 ELGO LIMAX – ABSOLUTE POSITIONING SYSTEM .............................................................................................. 27 SEC-3Q – CONTROLLER MOTHER BOARD .......................................................................................................... 28 SEC-3AUX – BOARD WITH AUXILIARY RELAY ..................................................................................................... 33 SEC-3KBD – USER INTERFACE BOARD ................................................................................................................ 35 SEC-3S – SAFETY CIRCUIT BOARD ...................................................................................................................... 37 SEC-3C – CAR BOARD ........................................................................................................................................ 40 SEC-3TRG – COP BOARD .................................................................................................................................... 43 SEC-3I/O – CALLS EXTENSION BOARD................................................................................................................ 45 SEC-3 SUPPLY – SUPPLY AND BRAKE BOARD ..................................................................................................... 47 SEC-2L – FLOOR NODE BOARD........................................................................................................................... 50 SEC-2LPI – LANDING DISPLAY BOARD ................................................................................................................ 54 SEC-2FDR – ALARM BATTERY CHARGER ............................................................................................................ 55 MANUAL RESCUE INSTRUCTION........................................................................................................................ 57 HELPY L300 – TELEPHONE DIALER ..................................................................................................................... 59 LEGENDA ........................................................................................................................................................... 60 SOFTWARE DOWNLOADING ............................................................................................................................. 66 SOFTWARE UPDATING BY USB MEMORY STICK ................................................................................................ 69 V3F SPEED SELECTION ....................................................................................................................................... 70 X:\Ufficio Tecnico\DOCUMENTAZIONE\SECUR 3\Manuali\IM_SEC3_01.08_en.docx - 12/06/2014 follows: IM_SEC3_01.08_en.docx Introduction The SECUR 3 modular system allowed our designers to develop innovative and reliable microprocessor based controllers. This system assigns to peripheral co-processors the activation of related inputs and outputs. In this application every node of the system is connected by a simple two-wire connection. The serial communication system which is used between boards in car and in control panel is based on CAN (CONTROLLER AREA NETWORK). The protocol follows the ISO-IS 11898 rules for high speed transmission (over 125 Kbit/sec), and the ISO-IS 11519-2 for low speed transmission (up to 125 kbit/sec). The CAN network layout is a multi-master. In other words the unit that needs to send an information takes possess of the bus and send its message, which is received and decoded by the receiving units. If more units need contemporarily the bus for transmission, automatically the highest priority will be assigned. If one of the verification gives a negative result the message will be repeated. This is SECUR 3, a technologically advanced system. System description The SECUR 3 system is composed by the combination of the following electronic boards:  SEC-3Q: controller mother board. It is the base of the system, and holds:  SEC-3AUX: board with auxiliary relay  SEC-3IO: additional inputs and outputs board (calls, etc.)  SEC-3S: the safety circuit supervision board  SEC-3C: car roof board. It handles the communication between car and controller, and holds:  SEC-3I/O: additional inputs and outputs board (calls, etc.)  SEC-3TRG: is the COP board; collects all car commands and signalisations and transmit them to SEC3C board; it may be located both inside COP or in the connection box on car roof  SEC-2L: the landing node board. It handles the landing calls and signalisation, in serial mode, and holds:  SEC-2LPI: the driver for position indicators at landing (in serial mode only)  SEC-2FDR: the alarm battery charger and alarm handling. 2/70 follows: IM_SEC3_01.08_en.docx Technical specifications BASIC SPECIFICATION  Modular system up to 32 floors (64 services).  MB96F338U microprocessor  CAN (Controller Area Network) serial transmission with speed up to 125 kbit/sec. Connection through CAN from controller to:  Car, landings, inverter Interfaces  Removable user interface for parameter setting and controller diagnostic:  SECUR 3 system parameters  fault codes and diagnostic visualisation programming  date/time setting  special functionalities (rescue drive, door  inverter programming and diagnoistic commands, calls, etc.)  USB port for SW update and parameters backup  Serial port for local or remote monitoring Drives Hydraulic lift:  Power units: all  direct starting, star/delta starting, soft starter      Traction lift: Asynchronous motors Gearless Synchronous motors AC 1 / 2 speed V3F open loop (up to 1 m/s) V3F closed loop (up to 2.5 m/s) Logic  Push button  Down collective, Up collective, Full collective  Multiplex (up to 4 lift group) Doors  automatic, semi-automatic, swing doors  single, double access  contemporary or selective door opening   parking either with opened or closed doors door operators type: all   auto-dialer SMS automatic transmission in case of alarms Emergency devices  manual lowering emergency feature (standard on MRL Gearless installation)  automatic emergency device for lowering and doors opening 3/70 follows: IM_SEC3_01.08_en.docx Signalisation  24 VDC – 1W per output  Gong / voice announcer in 4 languages (standard) – other languages upon request  car position indication: 1 wire per floor, 7 segment, dot matrix, LCD binary  Other signalisation:  car busy/coming  hall lanterns - gong  car here  overload  car call registered  out of service  landing call registered  fire recall/fireman’s drive  car direction Protections All SECUR 3 input/outputs are protected against:  over-voltage (up to 125 VDC)  electro-magnetic interferences (according to EN standards)  motor temperature protection: thermistors or thermal relay    over current – short circuit lack/reverse phase max. run time ELECTRICAL SPECIFICATIONS Mains supply:  standard: 220V, 230V, 380V, 400V – 3 phase - 50 Hz.  optional: monophase 220V, 230V, 240V, 3 phase 208V, 415V – 50/60Hz. Brake supply:  standard: 200 VDC  optional: any other voltage Valves supply:  standard: 48 VDC  optional: all Safety circuit with optoisolators:  standard: 230 VAC – 48VDC  optional: 110VAC Shaft positioning system  bistable - monostable magnetic switches  absolute encoder by magnetic band Options  overload and full load function  short floor functions  car / landing priority  car light – fan timer  fire recall      advance door opening fireman’s drive floor access by code or iButton out of service remote monitoring    EN81/73 EN81/80 CE marking - 89/336/EEC e 93/68/EEC directives EN 50081-1 electromagnetic emissions EN 50082-2 electromagnetic immunity Certificate of conformity N. 490002 Norms       EN81/1; EN81/2  A3 amendment EN81/21 EN81/70 95/16/CE Legge 13 – DM 236 EN81/72    4/70 follows: IM_SEC3_01.08_en.docx Topographic drawings 5/70 follows: IM_SEC3_01.08_en.docx 6/70 follows: IM_SEC3_01.08_en.docx 7/70 follows: IM_SEC3_01.08_en.docx 8/70 follows: IM_SEC3_01.08_en.docx 9/70 follows: IM_SEC3_01.08_en.docx 10/70 follows: IM_SEC3_01.08_en.docx 11/70 follows: IM_SEC3_01.08_en.docx 12/70 follows: IM_SEC3_01.08_en.docx Cabinets 13/70 follows: IM_SEC3_01.08_en.docx 14/70 follows: IM_SEC3_01.08_en.docx 15/70 follows: IM_SEC3_01.08_en.docx 16/70 follows: IM_SEC3_01.08_en.docx 17/70 follows: IM_SEC3_01.08_en.docx 18/70 follows: IM_SEC3_01.08_en.docx Internal layout Control panelovra Car roof connection box 19/70 follows: IM_SEC3_01.08_en.docx Preliminary test In order to perform preliminary test a TEMPORARY command box has to be connected to controller, strictly following the below diagram. ! DO NOT USE THE PRE-WIRED INSPECTION BOX DELIVERED WITH THE CONTROLLER ! Do not install the car roof box (board SEC-3C) Referring to installation electric drawings, connect following circuits: a) Mains supply - terminals M1,M2,M3 (ref. page 1) b) Motor supply – terminals M4,M5,M6 (U,V,W – ref. page 1) c) Brake supply (if traction lift) – terminals 50 e 51 (ref. page 4), or BR+ e BR- (ref. page 22) d) Valves supply (if hydraulic lift) – (ref. page 4) e) temporary command box, by a suitable travelling cable ATTENTION: do not use the pre-wired inspection box f) motor thermal protection (ref. page 1) g) all the ground/earth connections to all devices h) bridge out connection related to non existing devices (ref. page 3) i) remove wire between P1/1 – P1/4 on controller board (SEC-3Q) Following verifications has to be performed: j) check all supply voltages k) check that controller display shows RECALL l) check that safety circuit led’s on board SEC-3S (SUPPLY, SHAFT, CAR , SWING DOORS, CAR DOORS, LOCKS) are lit while pressing RUN and UP or DOWN buttons on the command box. ATTENTION After the preliminary test is finished, restore all connection to the original condition, carefully checking the safety circuit. 20/70 follows: IM_SEC3_01.08_en.docx Insulation test instruction Preliminary operation:  Insulation test have to be performed after complete and correct functional test of the lift have been made.  Position the car between two floors and check that all doors are closed.  Check that AM circuit breaker (on control panel) is closed.  Switch off the mains (both power and light supply).  Remove all yellow/green wires from earth bar, except those connected to metal parts and to earth disperser.  Disconnect yellow/green wire from terminal 100, in controller and in car connection box.  Disconnect yellow/green wire from terminal 100 in the emergency battery drive SEC-3EBD  Remove connector P8 on SEC-3Q board.  Remove connector CAL on SEC-3FDR board.  Remove all connections from inverter (if provided).  Remove all connections between controllers (if multiplex lift group) and perform complete test procedure on every single lift. Insulation measures: By a 500V insulation tester, check resistance values between terminals according following table. Measured values (in megaOhm) must be higher than 0.5 MΩ. POWER CIRCUIT LIGHT CIRCUIT * DOOR CIRCUIT ALARM CIRCUIT M1 M4 (U) LC/L LV/L MPA/1 CAL/6 SAFETY CIRCUIT SQ1/3 SQ2/9 100 >0,5 >0,5 >0,5 >0,5 >0,5 >0,5 >0,5 >0,5 >0,5 >0,5 >0,5 >0,5 >0,5 >0,5 terminals EARTH (PE) * POWER CIRCUIT M1; M4 LIGHT CIRCUIT LC/L; LV/L DOOR CIRCUIT MPA/1 ALARM CIRCUIT CAL/6 (*) >0,5 Note: with 230VAC or mains voltage door operator supply do not run the test between POWER CIRCUIT and DOOR CIRCUIT. Restore all modified connections when finished. 21/70 follows: IM_SEC3_01.08_en.docx DZSM–Door Zone Safety Module Test Instruction When ADO (advance door open) and/or ACL (re-levelling) are provided, a Safety Module is fitted inside the controller. The safety module allows the car movement inside door zone with door open, for relevelling or advance door opening purpose. In order to test the device proceed as follows: Verify controller software reviosion = 02.52D or further Verify parameter 02.16 = Yes [DZSM Control] normal functional test  place the car at bottom floor and keep the door open  move the car by the manual lowering button or by opening the brake, in order to exit one of the floor magnets (ref. schematic drawing, pages 5 and 91)  pump or motor starts and car is moved until IU and ID will lit st 1 channel missing simulation  keep the door open  remove IU wire from terminal SC3/2  the car moves upward until it exit the door zone; then the car stops, and display shows [DZSM ERROR!]  in order to put the lift back in service restor connections, then press and hold the CLEAR button during 3 sec., then switch off the mains switch. nd 2 channel missing simulation  keep the door open  remove IZ wire from terminal SC3/4  move the car by the manual lowering button or by opening the brake, in order to exit both IU and ID floor magnets (ref. schematic drawing, pages 5 and 91)  car stand witout any movement, as the IZ door zone detection is missing  wait until DTS (drive time supervision) elapses o connect back wire to SC3/4; car remains standing as the error has been registered by the SEC-3Q board  in order to put the lift in service press the CLEAR button during 3 sec., then switch off the mains switch. st 1 channel sticking simulation  bridge out terminals SC3/2 – SC3/5  register a call  at arrival to destination floor led K1 remains off, and device will not allow relevelling with open door, displays shows [DZSM ERROR!]  perss CLEAR during 3 seconds to restore nd 2 channel sticking simulation  bridge out terminals SC3/4 – SC3/5  register a call  at arrival to destination floor led K1 remains off, and device will not allow relevelling with open door, displays shows [DZSM ERROR!]  perss CLEAR during 3 seconds to restore ref. functional drawing - page 5 – F.005.xxx 22/70 follows: IM_SEC3_01.08_en.docx EN-81 – A3 amendment Functionality test of the brake monitoring  For traction elevators with double brake microswitch This procedure can be applied on systems with FUJI drives only. CONDITIONS TO START THE TEST: ELEVATOR INSTALLED AND WORKING CORRECTLY TEST INSTRUCTION: 1. Make sure that the brake monitoring is activated, by checking that the parameter 02.31 is set to “2brake” 2. Test of brake 1: a. Register a call by the SEC-3KBD keypad b. During the drive, remove wire from terminal P14/1 (IN1) on SEC-3AUX board (in order to simulate a failure in brake 1). c. The drive must complete normally. After arrival at destination the elevator will be set OUT OF SERVICE and error message “ERR:BRK1 STOP” appears on the display d. Make sure that no calls are accepted anymore. e. Reconnect wire to terminal P14/1 f. Reset the system by pressing CLEAR button on the keyboard until the error message is cleared. 3. Test of brake 2: a. Register a call by the SEC-3KBD keypad b. During the drive, remove wire from terminal P14/1 (IN1) on SEC-3AUX board (in order to simulate a failure in brake 1). c. The drive must complete normally. After arrival at destination the elevator will be set OUT OF SERVICE and error message “ERR:BRK1 STOP” appears on the display d. Make sure that no call is accepted anymore. e. Reconnect wire to terminal P14/1 f. Reset the system by pressing CLEAR button on the keyboard until the error message is cleared. Note: if the test is performed while the car is at the floor, the error message is shown, but the system is not set out of service The test must be done before the activation of the elevator for the public and during the periodical checks. 23/70 follows: IM_SEC3_01.08_en.docx Tests of the A3 device with Door Zone Safety Module (DZSM) In order to test the correct operation of the safety device against uncontrolled movement an “A3 test kit” is provided. It operates on the safety circuit and simulates the opening of the landing doors outside the unlocking zone (test applicable only with the DZSM safety module). CONDITIONS TO START THE TEST: ELEVATOR INSTALLED AND WORKING CORRECTLY TEST INSTRUCTION: 1. Register a call by the SEC-3KBD keypad 2. Wait for the standby condition, i.e. the system is stationary with closed doors (led 1 2 3 4 5 6 lit on board SEC-3S) 3. Open the AM switch (to remove voltage from the safety circuit) 4. CONNECT THE A3 TEST KIT PROVIDED BY SECURLIFT 5. Set parameter 02.33 to "TEST” 6. Close the AM switch 7. Register a call by the SEC-3KBD keypad 8. The elevator starts moving and the controller sets the nominal speed 9. IF THE SAFETY SYSTEM WORKS CORRECTLY, THE ELEVATOR STARTS MOVING AND IS BLOCKED AS SOON AS IT LEAVES THE DOOR UNLOCKING ZONE. 10. Open the landing door by the emergency key and check the movement carried out by the car 11. To reset the system in working condition: a. close the landing door b. remove the A3 test kit c. restore the original connections d. press for 5 sec the Clear button on the SEC-3KDB keypad e. Return the parameter 02.33 to "Yes" f. press the RESET button on the SEC-3Q main board NOTE: The test system provided by SECURLIFT maintains the same safety level of the normal operating condition. The speed of the system reached at the moment you open the security contact depends on the speed reached by the car, and therefore by the acceleration that occurs in the 20cm of floor zone. The speed programmed for the A3 test is the same as the one set during normal operation. The test must be performed prior to first installation of the system, and during periodic checks. 24/70 follows: IM_SEC3_01.08_en.docx Electrical connection of the A3 test Kit 25/70 follows: IM_SEC3_01.08_en.docx Safety chain after insertion of the A3 test kit 26/70 follows: IM_SEC3_01.08_en.docx ELGO LIMAX – absolute positioning system Following procedures have to be performed only after lift installation is completed, with all safeties installed and checked. 1. 2. 3. 4. 5. Connect programming keypad to SEC-3Q board by the RJ45 cable Check parameter 01.02 – Number of stops [ nn] Check parameter 02.01 – Lift Type =  [Trac.Dig] if traction lift  [Hydr.Dig] if hydraulic lift Check parameter 07.01 - Encoder Type = [Limax2] Insert value in parameter 07.11 - Range Synch.: a) Rated speed = 0.63m/s 07.11 = 750mm b) Rated speed = 1m/s 07.11 = 1300mm c) Rated speed = 1.6m/s 07.11 = 2200mm 6. HYDRAULIC LIFT ONLY Verify default values: 09.01 = 100 09.02 = 1000 09.03 = 1000 09.04 = 1000 09.05 = 1000 Exit and save 7. SET floors levels 7.1. Go on car roof, connect programming tool to CAN1:A by a suitable CAN cable 27/70 follows: IM_SEC3_01.08_en.docx 7.2. Set parameter 07.04 – Floors Setup = [SETTING]; press M then to confirm; display shows P01 [00000] 7.3. Move the car to bottom floor level. Down run will be in inspection mode only, at low speed. 7.4. With car at bottom floor level press M; the level is registered and the system is now ready for second floor level acquisition; 7.5. Move the car in inspection mode to second floor level; press M; display shows the registered level for second floor and gets ready for next floor; 7.6. Move to next floor; each time by pressing M floor level is registered (stopping accuracy is not important). 7.7. Once the penultimate floor is registered next up run (to top floor) will be in inspection mode only, at low speed 7.8. Once top floor level is registered display shows End – save Eeprom 8. HYDRAULIC LIFT ONLY 8.1. Register some calls in UP direction, and verify on the display the stopping error. 8.1.1. To correct negative errors insert a negative correction at parameter 07.08 8.1.2. To correct positive errors insert a positive correction at parameter 07.08 8.2. Register some calls in UP direction, and verify on the display the stopping error. 8.2.1. To correct negative errors insert a negative correction at parameter 07.08 8.2.2. To correct positive errors insert a positive correction at parameter 07.08 9. TRACTION LIFT ONLY 9.1. Back to machine room – controller; connect programming tool to SEC-3Q board 9.2. Enter parameter 07.05 and press M then to confirm 9.3. Wait for the aquisition of the four speed decelaration (High - Int.High - Int.Low - Low); perss M 9.4. back to 07.01; press M 9.5. in menu 09 it is possible to check the registered slow down distances; exit and save. 10. Floors level fine setting 10.1. connect keypad to CAN1:A board by appropriate CAN cable; bring keypad inside the car; 10.2. set parameter 07.04 [RegFLOOR]; exit and save 10.3. place calls to every floor by the keypad (or  + M) 10.4. at every floor check stopping accuracy: a) if car stops low: by insert the error space (+ in millimeters) b) if car stops high: by  insert the error space (- in millimeters) c) press M to confirm modification 10.5. when finished, enter programming mode, set parameter 07.04 [No]; exit and save 11. Additional ajdustements  07.06 - A.D.Open Space = 150mm  07.07 - Range stop = 00040mm (traction)  07.08 - Range stop UP = 040mm (hydr.)  07.09 - Range stop DN = 040mm (hydr.)  07.10 - Range Relevel. = 060mm  07.12 - Range StopRelev. = 010mm (traction)  07.13 – Range StopRel.UP = 010mm (hydr.)  07.14 – Range StopRel.DN = 010mm (hydr.) 12. RE-LEVELLING adjustment (if present) Once stopping accuracy has been adjusted, reduce re-levelling space: 07.10 = 20mm Start the relevelling drive and adjust stopping accuracy as stated at point 8, but acting on parameter 07.12 (traction) or 07.13 e 07.14 (hydraulic). 28/70 follows: IM_SEC3_01.08_en.docx SEC-3Q – controller mother board SEC-3Q is the main board of the system, located inside the control panel. 29/70 follows: IM_SEC3_01.08_en.docx Dip switch SW1 PRG = always OFF WD = Watch Dog enable – always ON CAN2 = CAN termination. Refer to installation drawing – page 90. Dip switch SW2 DOOR = doors disable CALL = landing calls disable S1 = future use S2 = automatic calls test LED’s In the following tables all LED symbols are shown with power ON, with car parked at bottom floor, after reset drive has been accomplished.  = lit  = off  = blinking CAN1 RX/TX to car OK PBC  TX Keypad KBD CAN2 RX/TX to landings OK OK  Alarm installation blocked CAN3 RX/TX inverter OK E Alarm present +24 24 VDC   UP direction +5V 5 VDC   Danger speed alarm OK  Outputs OK   Speed pre-alarm OK Speed OK   DOWN direction Buttons RESET = makes a complete reset of the board, as if the power supply is switched off. Errors that may disable the lift operation (e.g. final limit switch, drive time supervision), are not cleared. S1 = in RECALL mode execute an UP run. S2 = in RECALL mode execute a DOWN run. Emergency alert While executing an emergency rescue, by just the brake opening function, board shows car direction (led’s  and ), and its speed by led’s:  = alarm danger speed - with beep with run stopping  = pre-alarm speed OK = safe speed 30/70 follows: IM_SEC3_01.08_en.docx Connectors On-board connectors are located in order to group all signals depending on their address (car, shaft, machine room). Connectors name and pin numbering are printed on the board as follows:  AUX Connection to board with auxiliary  USB USB plug relay SEC-3AUX  PRG software download  SCB connection to SEC-3S safety circuit  RS232 remote connection board P1 (RECALL inputs) P2 (load inputs) 1 NORM  Normal (= Recall) NC 1 OLD  Overload NC 2 I_UP  Inspection UP NC 2 FLD  Full load NO 3 I_DN  Inspection DOWN NC 3 MLD  Minimum load NO 4 GND 4 +24 VDC 5 GND P3 (various I/O) P4 (encoder) 1 FID  Fire racall NO 1 A  encoder A 2 FRD  Fireman’s drive NO 2 A encoder /A 3 OSS  Out of service NO 3 B  encoder B 4 IN1  not used 4 B encoder /B 5 OLI  Overload output 5 do not connect! +24VDC 6 OSI  out of service output 6 encoder – GND 7 ISP  INSPECTION/RECALL output. 8 AF  Alarm filter 9 +24 VDC 10 GND P5 (status inputs) P6 (drive outputs) 1 ZSP  Zero speed NC 1 RLV  Re-levelling 2 RDY  Inverter READY NC 2 EME  Emergency start 3 V3F OK  Inverter FAULT NC 3 BRK  Brake 4 EME  Emergency NO 4 MAIN  Main contactor 5 END EME  Emergency End 5 common 6 OCL  Car light 6 common 7 SP  Start Permit 8 +24 VDC 9 GND P7 (supervision input) P8 (supply) 1 MRM T  Machine room temperat. NC 1 +24 VDC - Can2 2 MOT T  Motor temperature NC 2 +24 VDC - Emergency 3 GND 3 +24 VDC - General 4 GND 31/70 follows: IM_SEC3_01.08_en.docx CAN1 (serial connection to car) 1 2 3 4 5 6 CH  CAN high CL CAN low +24 VDC GND +24 VDC GND CAN3 (serial connection to inverter) CAN2 (serial connection to landings and multiplex) 1 CH  CAN high 2 CL CAN low 3 +24 VDC 4 GND 5 +24 VDC 6 GND DOM (DOM option–door opening monitoring) 1 future use 2 future use 1 CH  CAN high 2 CL CAN low 3 +24 VDC 4 GND 5 +24 VDC 6 GND LED’s which are monitoring relay are connected in series to relay coil. 32/70 follows: IM_SEC3_01.08_en.docx SEC-3AUX – board with auxiliary relay SEC-3AUX board increases mother board functionalities. It is optionally used for door control, hydraulic valves drive, inverter interface. 33/70 follows: IM_SEC3_01.08_en.docx Connectors AUX = connection to SEC-3Q board P11 (supervision inputs) 1 OIL P  Oil pressure 2 OIL T  Oil temperature 3 GND 1 2 3 4 5 6 7 8 9 HIGH  LOW  INSP  UP  DN  STAR  MAIN  comune comune P13 (drive outputs) High speed Low speed Inspection speed UP command DOWN command STAR contactor MAIN contactor       P12 (outputs) Out of service A side door OPEN command A side door CLOSE command B side door OPEN command B side door CLOSE command Retiring ramp 1 2 3 4 5 6 7 OSI OP A CL A OP B CL B CAM GND 1 2 3 4 P14 IN1 Reduced HEADROOM IN2 Reduced PIT +24 VDC GND 34/70 follows: IM_SEC3_01.08_en.docx SEC-3KBD – user interface board SEC-3KBD is the user interface. It allows monitoring an programming of the system. At power-on the display shows software revision index, software revision date and motor drive code. Please refer to PM (programming manual) for detailed parameter list. 35/70 follows: IM_SEC3_01.08_en.docx Connectors On-board connector (PBC) allows connection to SEC-3Q board by a standard RJ45 serial cable. Trimmers Trimmer PT1 adjusts the LCD contrast. Buttons When in normal mode:  : OPEN door command  : CLOSE door command  : increase destination floor  : decrease destination floor  M : register a call to selected destination floor  Clear = if pressed during 3 sec. clears the error that are disabling the lift operation. Obviously, if the error still persists, the lift will be disabled again. When in recall mode:  : sets UP direction, in inspection speed  : sets DOWN direction, in inspection speed Programming To enter PROGRAM MODE:  press and hold M button for 3”; display will shows menu 00 “QUIT”  press or to scroll menus  press M to enter selected menu  press: scroll parameters forward  press: scroll parameters forward  press: increase parameter value  press: decrease parameter value  press M to exit menu To exit PROGRAM MODE:  press Back per andare al menù 00 – “ESCI”  press M  press M  press : save modification  press : don’t save modification Monitoring Perss M +  to scroll info pages:  CALLS (car side A, car side B, down side A, down side B, up side A, up side B)  CAR inputs (SEC-3C car board led’s and connectors monitoring)  SHAFT signals (IU – ID)  SOFTWARE revisions (controller, car, landind A and B side)  ENCODER (with digital shaft only)  GROUP (duplex, triplex, quadruplex) 36/70 follows: IM_SEC3_01.08_en.docx SEC-3S – safety circuit board SEC-3S board is the interface to all devices related to safety circuit. 37/70 follows: IM_SEC3_01.08_en.docx LED’s In the following tables all LED symbols are shown with power ON, with car parked at bottom floor, after reset drive has been accomplished.  = lit  = off  = blinking SUPPLY  safety circuit START: AM TR  future use circuit braker, phase DZM  future use supervision, pit stop sw., OSG IU   UP magnetic switch rope tensioner ID   DOWN magnetic switch SHAFT  shaft static safety circuit: final IZ  DOOR ZONE magnetic switch limit sw., buffers, OSG, etc. IM  Car at floor magnetic switch CAR  car safety circuit: stop sw., inspection sw., safety gear sw. SWING DOORS  landing swing doors safety circuit CAR DOORS  car door safety contact LOCKS  landing doors locks contacts Connectors  SCB = connessione alla scheda SEC-3Q SH1 (shaft) 1 SUPPLY PST: Pit Stop Switch SHAFT FLS: X: Final Limit Switches buffers Overspeed Governor 3 5 7 SH2 (landing doors) 1 3 5 SWING DOORS PM: manual landing swing doors LOCKS CP: landing doors locks 7 1 CAR 3 5 CAR DOORS 7 9 SC1 (car) SGS: Safety Gear Switch CAR: Inspection box LPK: Car Locking Pin CPC: Car Door Contact RB/RDF: Recall Drive Switch 38/70 follows: IM_SEC3_01.08_en.docx 1 2 3 4 5 IM IU  ID  IZ GND SC3 (monostable shaft switches) CAR AT FLOOR magnetic switch UP magnetic switch DOWN magnetic switch DOOR ZONE magnetic switch SM1 (machine room safeties) 1 3 4 6 1 3 5 BRK: manual brake switch OSG: Overspeed Governor SQ1 (controller interface) common Safety Circuit Start common SQ2 (recall drive) 1 3 5 7 5 RDF RB - RDF Safety Circuit End SQ3 (ADO-ACL safeties) 1 3 4 6 DZSM T30 – TH - TR SQ4 (ADO-ACL safety module interface) 1 2 3 4 5 6 7 8 9 10 11 12 1 2 UP sensor output DOWN sensor output DOOR ZONE sensor output DOOR ZONE output controlled by  SEC-3Q DZSM control GND +24 VDC GND IM (car at floor sensor) LED supply IM 39/70 follows: IM_SEC3_01.08_en.docx SEC-3C – car board SEC-3C is the interface between controller and all car devices. Dip switches WD = Watch Dog enable - always ON PRG = always OFF Jumper J3 = not used 40/70 follows: IM_SEC3_01.08_en.docx LED In the following tables all LED symbols are shown with power ON, with car parked at bottom floor, after reset drive has been accomplished.  = lit  = off  = blinking STS  +24V  24 VDC (fuse F1) TX Serial transmission +24V 24 VDC RX  Serial reception +5V 5 VDC     outputs overload OK outputs OK Buttons RESET = makes a complete reset of the board, as if the power supply is switched off. = if in inspection mode – open the doors = if in inspection mode – close the doors Connectors  CAN1IN - CAN1OUT = serial communication connectors C2A (door A) C2B (door B) 1 OL A  OPEN limit switch NC 1 OL B  OPEN limit switch NC 2 CL A  CLOSE limit switch NC 2 CL B  CLOSE limit switch NC 3 CFL A  Safety edge NC 3 CFL B  Safety edge NC 4 GND 4 GND 5 SD A Inspection 5 SD B Inspection 6 “ “ 6 “ “ 7 CL A  CLOSE command NO 7 CL B  CLOSE command NO 8 “ “ 8 “ “ 9 OP A  OPEN command NO 9 OP B  OPEN command NO 10 “ “ 10 “ “ 11 +24 VDC 11 +24 VDC 12 GND 12 GND C3A (photocell A) C3B (photocell B) 1 PH A  photocell contact NC 1 PH B  photocell contact NC 2 GND 2 GND 3 +24 VDC photocell supply 3 +24 VDC photocell supply 4 GND 4 GND C4 (inspection inputs) C7 (synchronisation inputs) 1 NORM. Normal ( = Inspection) NC 1 RU  UP synchr. sw. NC 2 IUP  Inspection UP NC 2 RD  DOWN synchr. sw NO 3 IDN  Inspection DOWN NC 3 GND 4 GND C6 (load inputs) CAN1OUT (serial ling to COP – SEC-3 TRG) 1 OLD  Overload NC 1 CH – CAN high 2 FLD  Full load NO 2 CL – CAN low 3 MLD Minimum load NO 3 +24 VDC 4 +24 VDC 4 GND 5 GND 5 +24VDC 6 GND 41/70 follows: IM_SEC3_01.08_en.docx 1 2 3 4 5 6 7 8 9 10 C12 (various I/O) IN1 future use IN2 future use IN3 future use IN4 future use OUT1 FIRE fire/fireman’s OUT2 PRL Landing priority OUT3 ALF Alarm filter – Easy Alarm OUT4 VIS SEGNALAZIONE VISITATORI +24 VDC GND 1 2 3 4 5 6 CAN1IN (serial link to controller – SEC-3Q) CH – CAN high CL – CAN low +24 VDC GND +24VDC GND LED’s which are monitoring relay are connected in series to the relay coil. 42/70 follows: IM_SEC3_01.08_en.docx SEC-3TRG – COP board SEC3-TRG is the Car Operation Panel board. It collect sall the calls and drives all the signalizations. 43/70 follows: IM_SEC3_01.08_en.docx Connectors CT9 1 O_EME In Emergency output OVR Overload 2 O_GNG aux. Gong output 3 FRD2  2nd Fireman’s key NC 4 IN calls disable input 5 +24 VDC 6 GND CT11 (uscite posizione cabina) 1 a segment a bin 1 dec 1st floor 2 b segment b bin 2 dec 2nd floor 3 c segment c bin 4 dec 3rd floor 4 d segment d bin 8 dec 4th floor 5 e segment e bin 16 dec 5th floor 6 f segment f bin 32 dec 6th floor 7 g segment g dec 7th floor 8 O_OVR overload output (with 7 segmenti Minus symbol) dec 8th floor 9 +24 VDC 10 GND CT8 (options) 1 FRD Fireman’s key switch 2 STOP & OSS:  STOP/OSS input 3 PRC  Car Priority key switch 4 O_FIRE  Fire/Fireman’s output 5 OSI Out of Service output 6 O_PRC Priority call output 7 +24VDC 8 GND BST LCD interface 1 TX OUT 2 RX IN future use 3 +24VDC 4 GND CAN1 IN (serial link to SEC-3C) GRAPHIC DISPLAY interface Future use 1 2 3 4 CT10 UPD: UP direction arrow DND: DOWN direction arrow +24 VDC GND 1 2 3 4 5 6 7 8 9 10 CT4 door open door close +12VDC +12VDC emergency light alarm button intercom + (alarm sent) intercom – +12VDC -12VDC CT3 (ISE inputs) intercom + (alarm sent) intercom – alarm button luce emergenza alarm received +12V //not used// +12VDC -12VDC CT6 1 +12VDC 2 alarm sent 3 alarm received 4 -12VDC iB 1 iButton key 2 GND PX1 & PX2 (car calls IN-OUT) PX1: 1-8 floors side A PX2: 9-16 floor side A Or 1-8 floor side B 1 2 3 4 5 6 7 8 44/70 follows: IM_SEC3_01.08_en.docx SEC-3I/O – calls extension board SEC-3I/O board is the interface for car calls (over 16 services) or for some special function. Each board collects up to 8 calls. Appropriate setting of dip-switches configures the board function. LED’s In the following tables all LED symbols are shown with power ON, with car parked at bottom floor, after reset drive has been accomplished.  = lit  = off  = blinking PX (additional car calls - dip 3 ON) PX (additional car calls - dip 4 ON) 1  Car call 17 1  Car call 25 2  Car call 18 2  Car call 26 3  Car call 19 3  Car call 27 4  Car call 20 4  Car call 28 5  Car call 21 5  Car call 29 6  Car call 22 6  Car call 30 7  Car call 23 7  Car call 31 8  Car call 24 8  Car call 32 9 +24 VDC lamps common 9 +24 VDC lamps common 10 GND buttons common 10 GND buttons common 1 2 3 4 5 6 7 8 9 10 PX (additional car calls - dip 5 ON)  Car call 33  Car call 34  Car call 35  Car call 36  Car call 37  Car call 38  Car call 39  Car call 40 +24 VDC lamps common GND buttons common 1 2 3 4 5 6 7 8 9 10 45/70 PX (additional car calls - dip 6 ON)  Car call 41  Car call 42  Car call 43  Car call 44  Car call 45  Car call 46  Car call 47  Car call 48 +24 VDC lamps common GND buttons common follows: IM_SEC3_01.08_en.docx 1 2 3 4 5 6 7 8 9 10 PX (smoke detector - dip 3 ON)  floor 1  floor 2  floor 3  floor 4  floor 5  floor 6  floor 7  floor 8 +24 VDC GND common 46/70 follows: IM_SEC3_01.08_en.docx SEC-3 SUPPLY – supply and brake board Sec-3SUPPLY has following functions:  Provides al the voltage supplies to controller  Handle brake opening and closing  Reduce brake heating and power consumption (eco-brake)  Keeps batteries charged and monitored  execute the assisted emergency drive (movement check, speed check, safety circuit check) by opening the brake in case mains power failure 47/70 follows: IM_SEC3_01.08_en.docx Normal mode Provides all necessary power supplies for the correct installation functioning. Handles the brake opening controlled by the contactors and by the drive. Maintains in charge two batteries 12V 7AH ( in series) and monitor their status; in case of missing or flat/damaged batteries the board gives an alert beep. Signalisations  LED D2   LED D5   LED D10   LED D14   LED D58   LED D61   LED D60   LED D57   LED D56   OUT1   OUT2  24VDC ok (shaft – CAN2) 24 VDC ok (Controller/Car – CAN1) battery charger ok brake opening 5VDC ok microprocessor OK (lampeggiante) not used not used hardware fault (switch the board off and then on) relay output - connector SF7 (not used) relay output - connector SF7 (not used) Connectors ST1/1 400 VAC IN ST1/3 ST2/1 230 VAC DOORS IN ST2/2 ST3/1 23 VAC IN ST3/2 SF1/1 400 VAC OUT SF1/3 SF2/1 230 VAC PORTE OUT SF2/3 SF3/1 SF3/2 SF3/3 SF3/4 CAN 2 EME CAN 1 GND ST3/3 19 VAC CAR IN ST3/4 ST3/5 19 VAC SHAFT IN ST3/6 ST4/1 SF4/1 S1 T1 OUT 230 VAC SAFETY CIRCUIT OUT ST4/3 SF4/2 ST4/1 SF4/1 S1 T1 OUT ST4/3 ST5/1 230 VAC INVERTER LOGIC IN ST5/2 230 VAC SAFETY CIRCUIT OUT SF4/2 SF5/1 SF5/2 SF5/3 SF5/4 SF5/5 SF5/6 48/70 SAFETY CIRCUIT END SAFETY CIRCUIT END KP/13 KP1/13 BARKE DRIVE OUT BARKE DRIVE OUT follows: IM_SEC3_01.08_en.docx ST6/1 SF6/1 230 VAC SAFETY CIRCUIT IN NOT USED ST6/2 SF6/3 SF6/5 EMERGENCY BUTTON ST7 SF6/6 SF7/1 SF7/2 SF7/3 SF7/4 SF7/5 SF7/6 SF8 16 VAC OUT COM NO NC COM NO NC RELAY OUTPUTS IM – CAR AT FLOOR SP1 SP2 SP3 230 VAC INVERTER LOGIC OUT 200 VDC BRAKE OUT 24 VDC BATTERY SF9 SF10/1 SF10/2 SF10/3 SF10/4 SF11/1 IM (CAR AT FLOOR) 4TH POLE 24 VDC (BT+) GND EMERGENCY KEY SP4/1 SP4/2 SP4/3 SP4/4 A B VDC GND ENCODER REPETITION SF11/2 SF12/1 SF12/2 SF12/3 SF12/4 A B VDC GND ENCODER REPETITION Dip switches SETTING ROPING RESOLUTION PPR PULLEY Ø mm. FREQUENCY Hz. 1:1 1:1 1:1 1:1 1:1 1:1 1:1 1:1 1:2 1:2 1:2 1:2 1:2 1:2 1:2 1:2 512 1024 2048 4096 512 1024 2048 4096 512 1024 2048 4096 512 1024 2048 4096 210 210 210 210 320 320 320 320 210 210 210 210 320 320 320 320 233 466 932 1864 153 306 611 1223 466 932 1864 3727 306 611 1223 2446 1 PTA0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 49/70 DIP-SWITCH 2 3 PTA1 PTA2 0 0 0 0 0 1 0 1 1 0 1 0 1 1 1 1 0 0 0 0 0 1 0 1 1 0 1 0 1 1 1 1 4 PTA3 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 VALUE bin. 0 8 4 12 2 10 6 14 1 9 5 13 3 11 7 15 follows: IM_SEC3_01.08_en.docx SEC-2L – floor node board SEC-3L is the landing interface board. It collects landing calls, buttons and key switches, and drives all landing signalisations. 50/70 follows: IM_SEC3_01.08_en.docx Dip switch SW1 1 2 3 4 5 6 7 8 ID floor - bin 1 ID floor - bin 2 ID floor - bin 4 ID floor - bin 8 ID floor - bin 16 ID floor - bin 32 side B selection (if selective openings doors) WD = Watch Dog enable – always ON 51/70 follows: IM_SEC3_01.08_en.docx SW2 1 2 3 4 ID lift - bin 1 ID lift - bin 2 ID lift - bin 3 PRG = always OFF Jumper CAN = REFER to installation drawings – page 90. LED’s In the following tables all LED symbols are shown with power ON, with car parked at bottom floor, after reset drive has been accomplished.  = lit  = off  = blinking  =  Ouputs overload RX =  OK =  outputs OK AL =  serial communication alarm +5V =  Connectors  CAN UP – CAN DN = serial connection to controller and/or to other floor nodes  CPI = car position indicator interface board  PRG = software downloading  UPB – DNB = connection to landing call buttons  PKH = option inputs  OUT = option outputs  HLL = hall lanterns and gong output 52/70 follows: IM_SEC3_01.08_en.docx 1 2 3 4 5 6 1 2 3 4 1 2 3 4 5 CAN UP (supply and serial link) CAN H CAN L +24 VDC GND +24 VDC GND UPB (up button) up CALL input (+) up REGISTERED output (-) up REGISTERED (+24 VDC) up CALL (GND) PKH (option inputs) PRL – Priority call OSS – Out of Service key LOL – call disable VIS – visitors delivery FET/FEB – Floor Extension (Top/Bottom) Car preference call 1 2 3 4 5 6 1 2 3 4 1 2 3 4 5 6 6 7 +24 VDC 8 GND HLL (hall lanterns and gong output) 1 LAL - UP lantern 2 LAL - DOWN lantern 3 FET/FEB – Car preference call accepted 4 VIS – visitors delivery 5 +24 VDC 6 GND 53/70 CAN DN (supply and serial link) CAN H CAN L +24 VDC GND +24 VDC GND DNB (down button/call) down CALL input (+) down REGISTERED output (-) down REGISTERED (+24 VDC) down CALL (GND) OUT (option output) OSI – Out of Service indication HSL – car Here indication Fireman’s drive indication FLD – Full Load indication BEEP – EN 81-70 +24 VDC follows: IM_SEC3_01.08_en.docx SEC-2LPI – Landing display board SEC-2LPI is the car position indicator driver at landings, when serial landing connection is used. It fits on the SEC-2L board by connector CPI. DSP (car position output) 1 a segment a bin 1 2 b segment b bin 2 3 c segment c bin 4 4 d segment d bin 8 5 e segment e bin 16 6 f segment f bin 32 7 g segment g 8 G segment G 9 +24 VDC 10 GND dec 1st floor dec 2nd floor dec 3rd floor dec 4th floor dec 5th floor dec 6th floor dec 7th floor dec 8th floor 54/70 follows: IM_SEC3_01.08_en.docx SEC-2FDR – alarm battery charger SEC-2FDR SEC-2FDR is the alarm interface board, and provides for battery charge and check. Jumper J1 = selects the battery size to be charged:  open = 2.2 Ah  closed = 7 Ah J2 = selects the car emergency light output contact (CAL/4):  1-2 = never use  2-3 = emergency light enabled with mains failure J3 = selects the alarm contact to be interfaced with autodialler device (TEL/3 – TEL/4):  1-2 = N.O. contact  2-3 = N.C. contact J4 = enables the battery check function:  open= RESET the “BATTERY LOW” signalisation”  closed= normal operation LED’s LED symbols are shown with power ON. BATT. OK  battery status check SUPPLY  light mains supply OK (230 VAC) Buttons S1 = reset (cancel) the alarm signalisation at landings. Anyway the signal disappear after 30’. 55/70 follows: IM_SEC3_01.08_en.docx Connectors 1 2 1 2 DZI (car at floor indicazion) +  positive LED out -  negative LED out ALB (machinery alarm button) PH A alarm button N.O. +12 VDC 1 ALC 2 ALC 1 2 3 4 ALB (pit alarm button) 1 PH A alarm button 2 +12 VDC NO 1 2 3 4 ALB (lobby alarm button) 1 PH A alarm button 2 +12 VDC NO 1 2 3 4 1 2 3 4 5 6 1 2 3 4 5 6 7 8 TEL (combinatore telefonico) intercom 1 intercom 2 alarm output NO “ “ +12VDC autodialer supply -12 VDC TEL/1 TEL/2 CAL (car alarm wiring) intercom 1 intercom 2 alarm button emergency light car at floor sensor ISE/1 ISE/2 CAB CEL IM +12 VDC +12 VDC -12 VDC LR (car light relay pre-wiring) 1 LR/1 RLC relay contavt 2 LR/2 “ NO 1 2 3 4 5 6 ALC (alarm output) alarm output ISE (machinery intercom) ISE/1 intercom 1 ISE/2 intercom 2 +12VDC -12 VDC ISE (pit intercom) ISE/1 intercom 1 ISE/2 intercom 2 +12VDC -12 VDC ISE (lobby intercom) ISE/1 intercom 1 ISE/2 intercom 2 +12VDC -12 VDC SAL (shaft alarm wiring) ABE alarm bell -12 VDC “ ALI alarm signalisation at landings -12 VDC “ +12VDC -12 VDC 1 OCL/1 2 3 OCL/3 4 OCL/4 OCL (car light) NEUTRAL car ligh LIVE - automatic car light LIVE - permanent car light NO NC “ 1 LC/1 2 3 LC/3 56/70 N.O. LC (230 VAC supply) NEUTRAL LIVE 230 VAC follows: IM_SEC3_01.08_en.docx Manual rescue instruction AVAILABLE on BRUSHLESS GEARLESS only Nominal speed reference setting – to be performed at lift commissioning 1. Set rated speed in parameter 50.01 2. Reset parameter 50.02 by pressing and holding 3 sec. both and buttons 3. Set parameter 50.02 to “Yes” 4. Exit programming mode and save modification 5. Run the lift for a long travel, at full speed 6. Enter parameter 50.02 and set it to “No” 7. If direction shown is opppsite to run command inverti t at parameter 50.03 Rescue operation has to be performed by trained and qualified personnel 1. 2. Check that all the landing and cabin doors are closed Open the IG mains switch (fig.1), and if present open IMT switch also Fig. 1 3. 4. Turn and hold CFE key switch (fig.2) a. wait for the beep ends, , and while keepeng key turned Press PEE button (fig.2) fig. 2 57/70 follows: IM_SEC3_01.08_en.docx a. brake opens and car moves in the most favourable direction b. verify speed and direction by checking led’s on SEC-3Q board (fig.3)         = = = OK= = UP direction speed ALARM speed pre-alarm speed OK DOWN direction fig.3 if car is at floor already the brake will not open. If speed exceeds safety level “ = speed ALARM “ car will be automatically stopped. If floor level has not been reached (IM lit) do not leave key and button. Brake will open again, may be several times, until floor level will be reached. 5. Once arrived at nearest floor led IM on SEC-3S board (fig.4) will lit and car will automatically stop IM fig. 4 6. 7. Leave PEE button and CFE key (fig.2) then open landing and car door by the emergency key which is guarded in machine room in order to evacuate passengers. Then close and lock all the doors Inform the maintenance company. 58/70 follows: IM_SEC3_01.08_en.docx HELPY L300 – Telephone dialer Quick programming  Set telephone switch to “T” (tone) Enter programming mode  *0# Telephone numbers 21 01 1 2 . . . … 1st telephone number … # 21 02 1 2 . . . … 2nd telephone number … # …………… 21 12 1 2 . . . … 12th telephone number … # Identification code 45 0 # sets immediate link Automatic answer 64 5 answer after 5 rings 65 9 max. speech time 66 0 telephone network Elevator identification message 71 01  … talk …  Listen recorded message 72 01 … ascoltare … Quit programming mode *0#  To restore factory setting:  * 0 # 99 Collegamento modulo GSM (opzionale) Remove connector TEL on battery charger Enter programming mode board SEC-2FDR  *0# GSM network selection  open GSM module and autodialler unit 66 1 GSM telephone network  position jumpers JP11 and JP12 to 2-3 Quit programming mode inside autodialler (see page 27 on *0#  instruction manual)  place the antenna on GSM module  install SIM card inside GSM module  connect GSM module to autodialler by the supplied cord  close back GSM module and autodialler Connect back connector TEL on battery charger board SEC-2FDR To restore factory setting:  * 0 # 99 Use of device Interphone communication Remote-to-car communication Lift handset and talk normally to the car. Dial the elevator telephone number Active alarm cancelling Listen to identification message.  *0#  * 0 # 11 to talk with the car Help request from elevator  to finish communication Answer the call and listen to the elevator identification message. 0 to talk with the car 5 to repeat identification message 1 to send “help is coming” signal 9 to reset alarm status For further instruction on advanced use and programming please refer to Helpy L300. 59/70 follows: IM_SEC3_01.08_en.docx Legenda Electrical drawings uses the following abbreviations: DEVICES abbreviation 12:H 12:N ABE ALM-GER ALS AM AP ARP AUX BRK CAB CEG CEL CFE CFE CG CH. CL:A CL:B CRA CRC CSD1 CSU1 DCB DOB DP DSV DZI DZSM EA EB EBD H EBD T EME EMM EMM ESS EU EU F.. FAN FCA1 description HIGH speed valve DOWN valve ALARM bell Gervall UCM supply unit ALARM signal at landings (legge 13) SAFETY circuit braker Interruttore magneto/termico PAWL DEVICE Minicontattore PAWL DEVICE BALAUSTRADE contact Manual BRAKE lever contact Car ALARM button Contatto esclusione grembiule Car EMERGENCY LIGHT Emergency Brake opening key switch DYNATECH A3 release key switch Contatto grembiule Landing loks supervision contact (additional) A side door CLOSE contactor B side door CLOSE contactor Door open braking contact Door close braking contact Bistable sensor for down transit speed check Bistable sensor for up transit speed check DOOR CLOSE button DOOR OPEN button Minicontattore blocco Alta Velocità Discesa Bucher DSV-A3 valve CAR AT FLOOR signal Door Zone Safety Module HIGH speed valve DOWN – LOW speed valve Dispositivo emergenza x oleo Dispositivo emergenza x fune Segnalazione IN EMERGENZA Emergency contactor Mains/Emergency swap contactor – for SEC-3SULLY board SOFT STOP valve Landing locks control device Braker and release coil for landing locks control device Fuses FAN command Fine corsa addizionale 60/70 notes EN 81-21 EN 81-21 EN 81-21 follows: IM_SEC3_01.08_en.docx FCM FCM:D FCM:U FCU FCU:U FID FLS:D FLS:U FMK FRD GRR HIC HRS ID IF IG IGE ILC ILV IM IMT INSP. ISE C ISE L ISE MR ISE P ISE PC ISE PP ISE R IU IZ KAK KD KDB Ke Ke2 KF KFP KH KL KLF KLT KML KP KP1 KR1 KS INSPECTION limit switch DOWN INSPECTION limit switch UP INSPECTION limit switch FINAL-ADDITIONAL INSPECTION limit switch Fine corsa ulteriore discesa FIRE RECALL switch DOWN final limit switch UP final limit switch FIA module contact FIREMAN’S DRIVE SWITCH Gervall UCM emergency supply switch ALARM RECEIVED signal ALARM SENT signal DOWN monostable sensor Impulsore monostabile EMERGENZA Fermator MAINS power switch Emergency power switch CAR LIGHT main switch SHAFT LIGHT main switch Car at floor sensor Magnetic/Thermic mains switch INSPECTION drive switch Car intercom Lobby intercom Machine room intercom Pit intercom Fireman’s car intercom Fireman’s landing intercom Car roof intercom UP monostable sensor DOOR ZONE monostable sensor FIA module contact DOWN contactor Dynamic braking contactor (brushless/gearless) Contattore EMERGENZA Contattore ausiliario EMERGENZA BRAKE contactor Contattore ausiliario FRENO HIGH speed contactor LOW speed contactor Relè controllo PUNTONE in fossa Relè controllo PARAPETTO mobile Micro-levelling contactor MAIN contactor Auxiliary contactor Relè controllo SICUREZZE STAR contactor 61/70 EN 81-21 EN 81-21 EN 81-21 EN 81-21 EN 81-21 EN 81-21 EN 81-21 EN 81-21 follows: IM_SEC3_01.08_en.docx KT KTE KTN KU L10 LF LKP LOC… LT LV M.. MER MK MLD NORM OP:A OP:B OSG OSI OSS OST OST P PAL PE PEE PHR PRC PS PST PT PWD R30 RAB RB RCLC RD RDF RE REU RFA RFE RI RID RIU RIZ RKF RLC DELTA contactor Emergency voltage contactor Normal voltage contactor UP contactor Blain A3 valve PUNTONE in fossa Car LOCKING contact Car call disable contact/key/switch Contatto parapetto mobile Segnalazione OK in fossa Power terminal Dispositivi controllo SERRATURE porte piano Bobina modulo FIA Contatto MINIMO CARICO Normal mode relay A side door OPEN contactor B side door OPEN contactor OVERSPEED GOVERNOR contact OUT of SERVICE signal OUT of SERVICE switch Overspeed governor remote test disable Connettore TEST limitatore velocità Pressostato di minima Pit ALARM button Ground terminals Emergency drive enable button Phase reversal/failure protection device Car priority switch Pressure contact Pit Stop switch Retiring ramp contactor Pawl device Speed < 0.30 m/s relay Car roof ALARM button RECALL drive enable button Car light supervision relay DOWN bistable synchronisation sensor RECALL drive switch Emergency drive relay EU (landing locks control device) release relay ALARM FILTER relay Montanari A3 relay INSPECTION relay DOWN sensor relay UP sensor relay DOOR ZONE relay Relè controllo FRENO Car light relay 62/70 EN 81-21 EN 81-21 follows: IM_SEC3_01.08_en.docx RLV RMAN ROS RP RR:A RR:B RRCH RSENS RSIC RTC RU RUN RVC SAM SEC-2ALM SEC-2ALM1 SEC-2ALM2 SEC-2ALMX SEC-2DOOR SEC-2FDR SEC-2L SEC-2LPI SEC-2OPT SEC-3AUX SEC-3C SEC-3EBD SEC-3I/O SEC-3Q SEC-3S SEC-3SPEED SEC-3SUPPLY SEC-3TRG SEM SGS SKP SKP SLS SM SST STOP T T30 TD TD1 TDR TE TFP Shaft light relay INSPECTION relay Relè FUORI SERVIZIO Fireman’s drive relay A door BRAKING RESISTOR B door BRAKING RESISTOR EU delay Timer DYNATECH A3 sensor relay Dynatech A3 safety circuit relay Overspeed governor rope tension contact UP bistable synchronisation sensor INSPECTION enable button FAN/LIGHT relay Selettore abilitazione MANUTENZIONE Safety circuit supply board 24VDC supply board 24VDC supply board Brake – Retiring Ramp supply board Door board Battery charger – alarm board Floor node board Landing display driver board I/O option board Auxiliary relay board Car roof board Emergency battery drive Calls extension board Controller mother board Safety circuit interface board Speed supervision board (> 1,6 m/s) Supplies and brake control board (gearless) COP board Emergency drive unit (hydraulic) SAFETY GEAR contact Contatto modulo FIA FIA module contact Fine corsa manutenzione Rilevatore fumi ai piani Soft –Starter device (hydraulic) STOP switch on inspection box Timer Speed < 0.30 m/s contactor DOWN contactor Auxiliary DOWN contactor Emergency inverter logic supply relay Emergency contactor Photocell contactor Brake – Retiring Ramp transformer 63/70 EN 81-21 follows: IM_SEC3_01.08_en.docx TH THR THR:H THR:L TINSP TKAK TKAK TMP TP TPT TR TRA TRC TRD TRF TRG TRM TRP TSD TV TVM UCM-100 VD VD2 VH VHD VHU VLD VLU VMD VML VMP VST VU VU/D X HIGH speed contactor Thermal relay Thermal relay for high speed winding Thermal relay for low speed winding Inspection contactor Minicontattore controllo modulo FIA FIA module contact SOFT STOP contactor Door transformer 3phase retiring ramp contactor Re-levelling contactor Trasformatore alimentazione PAWL DEVICE Trasformatore alimentazione centralina Moris DOMINO Transformer BRAKE transformer Gervall UCM transformer Main transformer Door transformer Contattore SICUREZZE STATICHE Cooling transformer SOFT STOP contactor GERVALL safety module DOWN valve A3 DOWN valve HIGH speed valve DOWN – HIGH speed valve UP – HIGH speed valve DOWN – LOW speed valve UP – LOW speed valve DOWN valve Levelling valve SOFT STOP valve STAR/DELTA valve; or START valve; or SOFT STOP valve UP valve UP/DOWN valve Buffer contact Car connectors abbreviation description CPC Car door contact Cont. Magn. Monostabili (IU - ID) + Cab. al piano e zona porte (IM SM IZ) Car Intercom – Alarm button – Emergency Light – Elarm Received signal Car Locking device A door supply 64/70 note follows: IM_SEC3_01.08_en.docx SGS SBM FPA FPB PT SPK CAN1 IN B door supply Car light/fan supply Car roof lighting Safety gera contact Inspection box safeties A door braking B door braking Retiring ramp Speech unit loudspeaker Controller-Car serial connection Shaft Connectors abbreviation description ABE Alarm bell AL Pit alarm button ALS Landing alarm signal BP Landing call buttons BRK Manual brake contact BZ Buzzer CP Landing locks contact DIA Car direction signals DNB Down call buttons DSP Car position indication FID Fire recall command FLS Final limit switch FRD Fireman’s drive command HLL Hall lanterns + gong ISE Intercom LV Pre-wired shaft light OSI Out of service signal OSS Out of service command OSV Overspeed governor remote command OUT Various outputs PKH Various inputs PM Swing doors preliminary contacts PR Car here signals PST Pit stop switch RTC Overspeed governor rope tension contact UPB UP call buttons X Buffer contact 65/70 note follows: IM_SEC3_01.08_en.docx Software downloading It is possible get the needed program following the link: http://mcu.emea.fujitsu.com/mcu_tool/software.htm FLASH PROGRAMMER 16FX software for Controller board. FLASH PROGRAMMER 16LX software for all other boards. SECUR 3 boards are on site programmable for easy updating. In order to download software please proceed as follows. 1. Install FLASH FX and LX in the computer 2. Start the correct FLASH.exe program 3. Connect SEC-2PRG cable between computer port (COM) and PRG connector on the board to be programmed 4. While pressing RESET button, set the board dip switches as follows:  WD = OFF  RS = OFF (if present)  PRG = ON  Release RESET button 5. Select the Target Microcontroller Select Target Microcontroller SEC-2L board = MB90F497/G SEC-3Q board = MB96F338R/U/Y SEC-3C board = MB90F345A/CA/AS/CAS SEC-3TRG board= MB90F345A/CA/AS/CAS SEC-3IO board= MB90F362E/ES/TES 66/70 follows: IM_SEC3_01.08_en.docx 6. Select “Crystal frequency” at 4MHz. Select “Crystal Frequency” a 4MHz. 7. Select COM port according to interface cable installation. Select COMport port Set COM1 67/70 follows: IM_SEC3_01.08_en.docx 8. Open file to be downloaded 9. Start downloading Start downloading RX and TX led’s blink. 68/70 follows: IM_SEC3_01.08_en.docx 10. While pressing the RESET button set the board dip switches SW1 as follows:  WD = ON  RS = ON (if present)  PRG = OFF 11. Set all default parameters (param. 98.02 = Yes) 12. Exit and save (param. 00.01 – Save changes - ok) 13. Enter programming again, check ALL parameters and set them according to installation. SOFTWARE UPDATING by USB memory stick 1. Switch OFF the mains, insert the USB key on the SEC-3Q board 2. Switch ON the mains 3. Using SEC-3KDB keypad select desired software revision to be loaded, then press M to start downloading. 4. Whwn finished the board go to normal mode automatically. 5. Load default parameters (param. 98.02 = Yes) 6. Exit and save (param. 00.01 – Save changes - ok) 7. Enter programming again, check ALL parameters and set them according to installation. 69/70 follows: IM_SEC3_01.08_en.docx V3F speed selection HIGH P3/1 High 50Hz - 1500rpm Intermediate High 40/50Hz - 1200/1500rpm Intermediate Low 30Hz - 900rpm Short floors 15Hz - 450rpm Reset 25Hz - 750rpm Inspection – Recall 20Hz - 600rpm Low 5Hz - 150rpm Zero 0Hz - 0rpm VACON terminals FUJI terminals LOW P3/2 INSP P3/3 VACON NXP VACON NXL FUJI    P2.2.7 P2.2.5 C11    P2.2.11 P2.2.9 C10    P2.2.12 P2.2.10 C08    P2.2.9 P2.2.7 C09    P2.2.13 P2.2.11 C05    P2.2.10 P2.2.8 C06    P2.2.8 P2.2.6 C07    P2.2.6 -- C04 70/70