Xyr 5000 Wg500/wa500

   EMBED


Share

Transcript

XYR 5000 WG500/WA500 Wireless Gauge and Absolute Pressure Transmitters 34-XY-03-51 9/2006 Europe PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE Function The WG/A510 is part of the XYR 5000 family of wireless products. These transmitters cover a wide pressure range, and can be used to monitor a variety of processes and assets in hazardous and remote areas. Since there are no wires to run, the transmitter can be installed and operational in minutes, quickly providing information about the variable being monitored. The Smart Response Manager allows the transmitter to adapt to changing process conditions, allowing greater visibility to process variation. Smart Response Manager allows the user to set thresholds which, when exceeded, cause the transmitter to adjust sampling and data transmission rates. The transmitter combines a high accuracy piezoresistive sensor with a Radio Frequency (RF) transceiver operating in the 868MHz ISM license-free band. Communication is a digital protocol, using Frequency Hopping Spread Spectrum (FHSS). FHSS ensures data integrity by continually switching the carrier wave over a wide range of frequencies. Power is supplied by a C size 3.6 V lithium battery, with an expected lifetime of up to five years. Enjoy the benefits of wireless technology today: • Improve Product Quality • Ensure High Uptime • Reduce Maintenance and Operational Costs • Meet Regulatory Requirements • Enhance Flexibility Wireless Transmitters Base Radio MODELS Gauge Pressure Model # UPPER RANGE LIMIT PSIG/BAR OVERLOAD LIMIT PSIG/BAR DIAPHRAGM/BODY MATERIAL (wetted parts) WG511 0 – 30/2.1 60/4.1 316L SS/316 SS WG512 0 – 250/17.2 500/34.5 316L SS/316 SS WG513 0 – 1000/69 2000/137.9 316L SS/316 SS WG514 0 – 5000/344.7 12000/827.4 17-4 pH/316 SS Absolute Pressure Model # UPPER RANGE LIMIT PSIA/BAR OVERLOAD LIMIT PSIA/BAR DIAPHRAGM MATERIAL WA515 0 – 30/2.1 60/4.1 316L SS/316 SS WA516 0 – 250/17.2 500/34.5 316L SS/316 SS Remote Gauge Pressure without Yagi Model # UPPER RANGE LIMIT PSIG/BAR OVERLOAD LIMIT PSIG/BAR DIAPHRAGM/BODY MATERIAL (wetted parts) WG521 0 – 30/2.1 60/4.1 316L SS/216 SS WG522 0 – 250/17.2 500/34.5 316L SS/216 SS WG523 0 – 1000/69 2000/137.9 316L SS/216 SS WG524 0 – 5000/344.7 12000/827.4 17-4 pH/316 SS WG525 0 – 100/6.9 200/13.8 316L SS/216 SS WG526 0 – 15/1.03 30/2.1 316L SS/216 SS Remote Gauge Pressure with Yagi Model # UPPER RANGE LIMIT PSIG/BAR OVERLOAD LIMIT PSIG/BAR DIAPHRAGM/BODY MATERIAL (wetted parts) WG561 0 – 30/2.1 60/4.1 316L SS/216 SS WG562 0 – 250/17.2 500/34.5 316L SS/216 SS WG563 0 – 1000/69 2000/137.9 316L SS/216 SS WG564 0 – 5000/344.7 12000/827.4 17-4 pH/316 SS WG565 0 – 100/6.9 200/13.8 316L SS/216 SS WG566 0 – 15/1.03 30/2.1 316L SS/216 SS Page 2 of 8 WIRELESS GENERAL SPECIFICATIONS (Europe) Wireless Communication 869.4 to 869.65 MHz Frequency Hopping Spread Spectrum (FHSS) Every data block transmitted is verified (CRC check) and acknowledged by the Base Radio. RF Transmit Power 10 dBm (10 mW), 6-8 dBm typical (7.8 to 9 dBm) Data Rate 4.8 Kbps. Update 5 seconds @ 4.8 Kbps. Antenna Omnidirectional Yagi Directional Internal 3” omni-directional, ¼ wave, monopole. Signal Range Up to 2000 feet (600 meters) from Base Radio with clear line of sight.* • • • • Length: 18”. Gain: 6 dBd. Weight: 1.5 lbs. Polarization: Vertical. Up to 5000 feet (1500 meters) from Base Radio with clear line of sight.* *Actual range may vary depending on site topography. SELF DIAGNOSTICS Self-checking software and hardware that identifies and reports out of spec conditions, and field unit low battery voltage. SITE SURVEY TOOLS RSSI Received Signal Strength Indicator displays the RF signal strength in one of seven ranges. Link Test Link Test measures the wireless link performance of a transmitter running in normal operating mode. This function looks at wireless performance in both directions, from the transmitter to base radio and vice versa and assigns a rating to that performance or quality of signal. FEATURES Automatic Re-transmit The field unit checks with the base radio to insure successful receipt of data. If data was not received, the transmitter retries on the next RF cycle. Ensures communication confidence in the harshest of industrial environments. At the maximum transmit rate this feature is inactive. Battery Life Saver To save conserve battery power, all field units will attempt to synchronize with the network using the following technique: Time 0 – 1 minute 1 – 10 minutes 10 – 30 minutes 30 – 60 minutes 1 – 12 hours 12 – 24 hours 24 – 36 hours 36 – 48 hours 48 + hours Page 3 of 8 Field Unit Synchronization Attempts and Attempt Delay Continuous Synchronization attempts One attempt with a 10 second delay between attempts One attempt with a 30 second delay between attempts One attempt with a 1-minute delay between attempts Three-attempt burst with a 5-minute delay between attempts Three-attempt burst with a 10-minute delay between attempts Three-attempt burst with a 30-minute delay between attempts Three-attempt burst with a 1-hour delay between attempts Three-attempt burst with a 2-hour delay between attempts OPERATING/STORAGE CONDITIONS 99% RH (non-condensing). Humidity Temperature Ambient Sensor: -40 to +230°F (-40 to +110°C) Ambient Electronics: -40 to +185°F (-40 to +85°C) Process fluid: -40 to +250°F (-40 to +121°C) Display (Full visibility): -4 to +158°F (-20 to +70°C) Display (Reduced visibility): -40 to +185°F (-40 to +85°C) Storage: -58 to +185°F (-50 to +85°C). DEVICE CONFIGURATION Parameter Configuration Configuration Panel • RF Channel Setup: 1 to 4 • Baud Rate: 4.8 Kbps. • RF ID: 1 to 49. • Password. • Tag Name (up to 21 characters). • Normal Transmit Rate: (5 sec, 10 sec, 15 sec, 20 sec, 40 sec, 1 min). • Normal Sampling Rate: (1–10 sec, 15 sec, 20 sec, 30 sec, 1 min). • Abnormal Transmit Rate: (5 sec, 10 sec, 15 sec, 20 sec, 40 sec, 1 min). • Abnormal Sampling Rate: (1–10 sec, 15 sec, 20 sec, 30 sec). • Pressure Normal Upper Value: Disabled/Enabled. Enabled to change Sampling and Transmit rates during abnormal process conditions. • Pressure Normal Lower Value: Disabled/Enabled. Enabled to change Sampling and Transmit rates during abnormal process conditions. • Engineering Units: PSI, bar, mBar, Pa, kPa, Torr, Atm, inH20, inHg, ftH20, mmHg, g/cm2, kg/cm2. • Pressure Zero. • Offset: User defined offset will be transmitted instead of actual value. • Trim: Applies a user-defined one- or two-point correction curve to the actual value. Integrated LCD display with membrane switch buttons for local configuration. LCD display is 7-digit (alternating) high contrast, anti-reflective monochrome. Display cycles between pressure level and RF status. PERFORMANCE Accuracy (linearity and hysteresis) ±0.1% FS over temperature. Combined Zero and Span Stability Less than ±0.1% of sensor URL per year @ 21°C (70°F). Resolution 24-bit A/D converter. Page 4 of 8 PHYSICAL SPECIFICATIONS Process connections 1/2" - NPTM. Base Material (bob-wetted) 304 SS Electronic Housing GE Lexan. V0 Rating and UV Stable. Vibration and Shock Certified per IEC EN 60068-2-6 (Vibration), and EN 60068-2-27 (Shock). Random Vibration Certified to withstand 6 g’s, 15 minutes per axis from 9 – 500 Hz. Net weight Pressure w/o Yagi Pressure w/Yagi Remote Sensor w/o Yagi Remote Sensor w/Yagi 1 kg (2 lbs.) 1.8 kg (3.5 lbs.) 6.7 kg (13 lbs.) 7.7 kg (15 lbs.) Electromagnetic Compatibility (CE Compliance) Operates within Specifications in fields from 80 to 1,000 MHz with Field Strengths to 10 V/m. Meets EN 50082-1 General Immunity Standard and EN 55011 Compatibility Emissions Standard. APPROVALS Environmental protection NEMA 4X, IP 65 Combined FM/CSA FM – Explosion proof - Class I, Div. 1, Groups B,C,D, T5,T6, Enclosure 4X Dust-Ignition proof - Class II, III, Div. 1, Groups E,F,G, T5,T6, Enclosure 4X CSA - Explosion proof - Class I, Div. 1, Groups B,C,D, T5, Enclosure 4X Dust-Ignition proof - Class II, III, Div. 1, Groups E,F,G, T5, Enclosure 4X Combined CE/ATEX CE EMC Conformity, ETSI EN 300 489-1 Intrinsically Safe, Zone 0/1: Ex II 1 G EEx ia IIC T4, T5, T6 Non-Sparking, Zone 2: Ex II 3 G EEx nA, IIC T6 Page 5 of 8 DIMENSIONS 97.5/3.84 97.5/3.84 116.5/4.59 172.2/6.78 mm/inches Integral 584mm/23” Nominal 3.04m/10’ Nominal 3.04m/10’ Nominal ½” NPT Male Remote Sensor w/Yagi Page 6 of 8 Remote Sensor Model Selection Guide XYR 5000 Wireless Gauge & Absolute Pressure Transmitters Model Selection Guide 34-XY-16-01 Issue 6 Instructions Select the desired key number. Key Number I (Approvals) _____ - __ KEY NUMBER Selection Description Span Gauge Pressure Transmitter 0 - 30 psig (2 bar) WG511 Gauge Pressure Transmitter 0 - 250 psig (17.2 bar) WG512 Gauge Pressure Transmitter 0 - 1000 psig (69 bar) WG513 Gauge Pressure Transmitter 0 - 5000 psig (345 bar) WG514 Absolute Pressure Transmitter 0 - 30 psia (2 bar-abs) WA515 Absolute Pressure Transmitter 0 - 250 psia (17.2 bar-abs) WA516 Availability TABLE I - CERTIFICATION OPTIONS Location or Classification Certificate Approval Type Combined FM & CSA Intrinsically CL I, II, III, Div 1, Gp A,B,C,D,E,F,G T4; Safe CL I, Zone 0, AEx ia IIC T4; Enclosure Type 4X Nonincendive Class I, Div 2, Groups A,B,C,D; Suitable for CL II, III, Div 2, Groups F,G, T4; Intrinsically Safe Nonincendive CL I, Zone 2, AEx nA IIC T4; Enclosure Type 4X CL I, II, III, Div 1, Gp A,B,C,D,E,F,G T3; CL I, Zone 0, Ex ia IIC T4; Enclosure Type 4X Class I, Div 2, Groups A,B,C,D; Suitable for CL II, III, Div 2, Groups F,G, T3; CL I, Zone 2, Ex n IIC T4; Enclosure Type 4X Ex II 1 G EEx ia IIC T4; Ta -40 to 65° Ex II 3 G EEx nL, IIC T4; Ta -40 to 85° Enclosure IP 65 AG Multiple Marking** Int. Safe, Zone 0/1, 3G or Non-Sparking, Zone 2 * See ATEX installation requirements in the Operator's Manual. ** The user must determine the type of protection required for installation of the equipment. The user shall then check the box [?] adjacent to the type of protection used on the equipment certification label. Once a type of protection has been checked on the label, the equipment shall not then be reinstalled using any of the other certification type. ATEX* RESTRICTIONS Restriction Letter Table b Page 7 of 8 Available Only With Selection Mutually exclusive - select one Not Available With Table Selection b Model Selection Guide 34-XY-16-16 Issue 2 Instructions Select the desired key number. Key Number _____ I (Approvals) - __ KEY NUMBER Description Remote Sensor GP Transmitter Remote Sensor GP Transmitter Remote Sensor GP Transmitter Remote Sensor GP Transmitter Remote Sensor GP Transmitter Remote Sensor GP Transmitter Span 0 - 30 psig (2 bar) 0 - 250 psig (17.2 bar) 0 - 1000 psig (69 bar) 0 - 5000 psig (345 bar) 0 - 100 psig (6.9 bar) 0 - 15 psig (1 bar) Selection Remote Sensor GP Xmtr with Yagi antenna 0 - 30 psig (2 bar) WG561 Remote Sensor GP Xmtr with Yagi antenna 0 - 250 psig (17.2 bar) WG562 Remote Sensor GP Xmtr with Yagi antenna 0 - 1000 psig (69 bar) WG563 Remote Sensor GP Xmtr with Yagi antenna 0 - 5000 psig (345 bar) WG564 Remote Sensor GP Xmtr with Yagi antenna 0 - 100 psig (6.9 bar) WG565 Remote Sensor GP Xmtr with Yagi antenna 0 - 15 psig (1 bar) WG566 Availability WG521 WG522 WG523 WG524 WG525 WG526 c c c c TABLE I - CERTIFICATION OPTIONS Location or Classification Certificate Approval Type Intrinsically CL I, II, III, Div 1, Gp A,B,C,D,E,F,G T4; Safe CL I, Zone 0, AEx ia IIC T4; Enclosure Type 4X Nonincendive Class I, Div 2, Groups A,B,C,D; Suitable for CL II, III, Div 2, Groups F,G, T4; Combined FM & CSA AG CL I, Zone 2, AEx nA IIC T4; Enclosure Type 4X Intrinsically CL I, II, III, Div 1, Gp A,B,C,D,E,F,G T3; (CSA Pending) Safe CL I, Zone 0, Ex ia IIC T4; Enclosure Type 4X Nonincendive Class I, Div 2, Groups A,B,C,D; Suitable for CL II, III, Div 2, Groups F,G, T3; CL I, Zone 2, Ex n IIC T4; Enclosure Type 4X Multiple Marking** Ex II 1 G EEx ia IIC T4; Ta -40 to 65° ATEX* Int. Safe, Zone 0/1, or Ex II 3 G EEx nL, IIC T4; Ta -40 to 85° 3G Non-Sparking, Zone 2 Enclosure IP 65 * See ATEX installation requirements in the Operator's Manual. ** The user must determine the type of protection required for installation of the equipment. The user shall then check the box [?] adjacent to the type of protection used on the equipment certification label. Once a type of protection has been checked on the label, the equipment shall not then be reinstalled using any of the other certification type. RESTRICTIONS Restriction Letters b c Table Industrial Measurement and Control Honeywell International Inc. 2500 West Union Hills Drive Phoenix, Arizona 85027 Page 8 of 8 b Available Only With Not Available With Selection Table Selection Mutually exclusive - select one Consult Customer Service 800-343-0228 ©Honeywell International Inc.