Preview only show first 10 pages with watermark. For full document please download

Ypp-heat Pump For Swimming Pool

   EMBED


Share

Transcript

heating systems YPP Heat pump for swimming pool YPP-A and YPP-C 7 to 120 heating systems YPP-Heat pump for swimming pool YPP-A and YPP-C 7 to 120 A complete range from 7 kW to 116 kW Features YPP-A-22T • The cheapest solution to heat the water of your outdoor or indoor swimming pool with a high COP around 5. •A  large range available to heat from a spa till a 25-metre long pool with 2 ranges: - YPP-A with axial fans (7-23 kW) - YPP-C with centrifugal fans to be installed inside the building (29-116 kW) (consult us for more details) • Special scroll plate heat exchanger in TITANIUM (fig. 1) •“  PLUG and PLAY” units with very easy electric and water connections without opening the unit. •W  ell-protected units with mechanical flow switch, high and low pressure automatic pressostat and Gold-Fins coil (for small YPP-A). •T  hermodynamic defrost system with 4-way valve included to heat till –15°C outside temperature. • As an accessory, 2 sizes of detached titanium plate heat exchanger to be connected between a standard heat pump (as YLHA units) and the pool installation. • A water pump is not included since the filtration pump of the pool installation can be used instead (fig. 2). YPP-A-39T Special Scroll Plate Heat Exchanger In Titanium (fig.1) 100% Titanium Bigger exchange surface Inalterable metal Better COP Compatible with all kind of water treatment (salt, chlorine…) Section Scroll plate heat exchanger Easy Working (fig.2) 1. When the filtration pump starts, the mechanical flow switch unlocks the YPP. Technical local Chemical treatment 3. The compressor stops if either the set temperature is reached or the filtration cycle stops. Filter Pump From the pool by johnson controls Heat pump 2. If the cleaned-water temperature is 1 °C below the set temperature, the compressor starts. Back to the pool NB: as option, we can force the filtration cycle to start each 2 hours to heat more often. YPP-Heat pump for swimming pool YPP-A and YPP-C 7 to 120 Technical features : YPP-A range Horizontal air discharge Models Codes Working conditions Heating capacity Total input power COP Working conditions Heating capacity Total input power COP Working conditions Heating capacity Total input power COP Sound pressure level Lp at 10m Voltage / Phases / Frequency Running current Electric cable section Fuse Net weight Dimensions YPP-A-7M S687800408 kW kW 7.1 1.2 5.8 kW kW 6.9 1.4 4.9 kW kW dB(A) 6.2 1.6 4.0 44 A mm2 A kg Height Width Depth 7.1 2.5 12 56 653 866 373 YPP-A-10M YPP-A-14M YPP-A-17M YPP-A-14T YPP-A-17T S687800808 S687801808 S687903108 S687901908 S687903309 At 15° C air temperature; 15° C inlet water temperature; 18° C outlet water temperature 10.7 14.5 20.4 15.0 20.8 1.8 2.4 3.5 2.5 3.9 6.0 6.0 5.9 6.1 5.4 At 15° C air temperature; 24° C inlet water temperature; 27° C outlet water temperature 10.5 14.3 20.0 14.7 20.5 2.1 2.8 4.1 2.9 4.5 5.0 5.0 4.9 5.1 4.5 At 15° C air temperature; 27° C inlet water temperature; 30° C outlet water temperature 9.4 12.7 17.9 13.1 18.3 2.3 3.1 4.5 3.2 5.0 4.1 4.1 4.0 4.2 3.7 44 46 48 46 48 230 - 1 - 50 400 - 3 - 50 11.1 15.8 20 5.6 8.8 4 4 4 2.5 2.5 16 20 25 12 16 95 118 140 118 143 762 965 1270 965 1270 905 460 YPP-A-22T S687804109 YPP-A-39T YPP-A-45T YPP-A-56T YPP-A-73T YPP-A-91T S687915700 S687916000 S687916400 S687917200 S687917700 At 15° C air temperature; 24° C inlet water temperature; 27° C outlet water temperature 38.0 43.0 55.0 71.0 88.0 7.9 10.0 12.2 16.1 20.0 4.8 4.3 4.5 4.4 4.4 400 - 3 - 50 19.3 25.5 2 x 13.9 2 x 19.3 2 x 25.5 6 10 16 25 32 40 50 63 80 276 342 450 495 610 1180 1 230 1 180 894 1 644 1 629 1 284 2 019 220 m3 270 m3 350 m3 450 m3 550 m3 YPP-A-120T S687919000 23.8 4.7 5.1 23.4 5.4 4.3 20.9 6.0 3.5 48 8.8 2.5 16 143 1270 Vertical air discharge (preliminary data) Models Codes Working conditions Heating capacity Total input power COP Voltage / Phases / Frequency Running current Electric cable section Fuse Net weight YPP-A-30T S687914800 kW kW 29.0 5.9 4.9 V A mm2 A kg Height Width Depth Dimensions 13.9 4 25 268 1 028 Maximum pool size orientation 180 m3 Accessory of pool plate heat exchanger Pool size in m3 Secondary circuit Secondary circuit temperature Heating capacity in kW Net weight Dimensions E-COM-YPP0901 10 °C 20 °C 30 °C kg Height Width Depth 2 x 28 25 80 940 1 452 1 976 2 454 700 m3 Quick Selection Guide of YPP units Primary circuit Models Codes 116.0 25.8 4.5 ET-NU 20 ET-NU 42 689200200 689200600 Primary circuit 50 °C 70 °C 80 °C 50 °C 70 °C 80 °C 14 22 27 31 49 58 11 20 24 24 42 52 8 17 21 17 35 45 4 4.5 197 197 493 648 166 166 Manufacturer reserves the rights to change specifications without prior notice. YPP 7M YPP 10 M YPP 14 M/T YPP 17 M/T YPP 22 T 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 Cold and nordic climate Temperate climate Mediterranean climate Tropical climate Note: this calculation is for an outdoor private pool of 1.5 metre depth open from april to september with a thermic cover. Contact with us if you have others parameters like a public pool, without cover, used all year long, etc… © 2010 Johnson Controls, Inc. www.johnsoncontrols.com Printed on recycled paper E-CAT-YPP-2010 http://www.johnsoncontrols.co.uk/unitary