Section 10 COAXIAL CABLE and FITTINGS SUMMARY RF CABLE ASSEMBLIES ÂÂ Custom Cable Assemblies ÂÂ Standard Cable Sets COAXIAL CABLE CABLE FITTINGS ÂÂ 7/8" Flexible Foam Dielectric, 50 Ohm ÂÂ Hoisting Stocking Grips ÂÂ 1/2" Flexible Foam Dielectric, 50 Ohm ÂÂ Bird-Proof Stainless Steel Braid ÂÂ 1/2" Super Flexible Foam Dielectric, 50 Ohm ÂÂ Snap-In Cable Hangers ÂÂ RU400 Low Loss, 50 Ohm ÂÂ Angle Adapters ÂÂ RU400-75 Low Loss, 75 Ohm ÂÂ Cleats ÂÂ RG213 MIL-SPEC, 50 Ohm ÂÂ PVC Cable Hangers ÂÂ RG214/U Double Shielded, 50 Ohm ÂÂ Trimming Tools ÂÂ RG223 Double Silver Braided, Low PIM, 50 Ohm ÂÂ Crimp Tools ÂÂ RG58 MIL-SPEC Low Loss Solid Core, 50 Ohm ÂÂ Stainless Steel Cable Tie Tensioner Tool ÂÂ RG58 A/U MIL-SPEC Stranded, 50 Ohm ÂÂ RG174A/U MIL SPEC Miniature, 50 Ohm ÂÂ RG316 Teflon Insulated Miniature, 50 Ohm ÂÂ RG142 Teflon Insulated Miniature, 50 Ohm ÂÂ RG11A/U Single Screened, 75 Ohm ÂÂ RG59 B/U MIL-SPEC, 75 Ohm ZCG Scalar, Head Office, 1 Hall Street, PO Box 7, Lindenow, Victoria, 3865, Australia Telephone (03) 5157-1203, Fax (03) 5157-1641 [email protected] www.zcg.com.au Section 10 RF CABLE ASSEMBLIES COAXIAL CABLE and FITTINGS Updated 24 November 2011 – Page 1 of 2 – ZCG Scalar can assemble RF cable sets from basic patch leads up to high-end base station and broadcast antenna feeder cables. 99 Practically any combination of cables and connectors are available – from Miniature through to Corrugated. You may specify your own custom requirements, or select from our standard range of coaxial cable assemblies. 99 Glued heat shrink on connector terminations. Quantity discounts are available. Contact us for pricing. CUSTOM CABLE ASSEMBLIES 99 Strain relief on connector terminations is available. 99 Stainless steel braid for bird-proofing is available. Simply specify your requirements as follows : 1) Coaxial Cable type. (e.g. 1/2", RU400, RG213, etc.) 2) Cable length. (e.g. 5 metres.) 99 Separate bagging and specialised part numbering as required. 3) Connector to be fitted on end A. (e.g. N-Male.) 4) Connector to be fitted on end B. (e.g. 7/16” DIN Male.) 5) Any special requirements. (e.g. Strain Relief, Stainless Steel Braid, etc.) 6) The total number of these cable sets you require. STANDARD CABLE SETS 7/8" FLEXIBLE FOAM DIELECTRIC, 50 OHM ORDER CODE Length Connector A Connector B CA106-S-N-78-78-E12 6 metres 7/8” EIA 7/8” EIA CA120-S-N-NM-NM-E12 20 metres N-Male N-Male 1/2" FLEXIBLE FOAM DIELECTRIC, 50 OHM ORDER CODE Length Connector A Connector B CA101-7-S-N-NM-NM-E11 1.75 metres N-Male N-Male CA102-S-N-NM-NM-E11 2 metres N-Male N-Male CA102-4-S-N-NM-NM-E11 2.45 metres N-Male N-Male CA102-5-S-N-NM-NM-E11 2.5 metres N-Male N-Male CA103-S-N-NM-NM-E11 3 metres N-Male N-Male CA103-S-N-NM-NF-E11 3 metres N-Male N-Female CA104-S-N-78-78-E11 4 metres 7/8” EIA 7/8” EIA CA125-S-N-NM-NM-E11 25 metres N-Male N-Male CA130-S-N-NM-NF-E11 30 metres N-Male N-Female 1/2" SUPER FLEXIBLE FOAM DIELECTRIC, 50 OHM ORDER CODE Length Connector A Connector B CA104-S-N-NM-DM-E13 4 metres N-Male 7/16” DIN Male RU400 LOW LOSS, 50 OHM ORDER CODE Length Connector A Connector B CA115-S-N-NM-NM-E7 15 metres N-Male N-Male ZCG Scalar, Head Office, 7 Hall Street, PO Box 7, Lindenow, Victoria, 3865, Australia Telephone (03) 5157-1203, Fax (03) 5157-1641 [email protected] www.zcg.com.au Section 10 RF CABLE ASSEMBLIES COAXIAL CABLE and FITTINGS Updated 24 November 2011 – Page 1 of 2 – ZCG Scalar can assemble RF cable sets from basic patch leads up to high-end base station and broadcast antenna feeder cables. 99 Practically any combination of cables and connectors are available – from Miniature through to Corrugated. You may specify your own custom requirements, or select from our standard range of coaxial cable assemblies. 99 Glued heat shrink on connector terminations. Quantity discounts are available. Contact us for pricing. CUSTOM CABLE ASSEMBLIES 99 Strain relief on connector terminations is available. 99 Stainless steel braid for bird-proofing is available. Simply specify your requirements as follows : 1) Coaxial Cable type. (e.g. 1/2", RU400, RG213, etc.) 2) Cable length. (e.g. 5 metres.) 99 Separate bagging and specialised part numbering as required. 3) Connector to be fitted on end A. (e.g. N-Male.) 4) Connector to be fitted on end B. (e.g. 7/16” DIN Male.) 5) Any special requirements. (e.g. Strain Relief, Stainless Steel Braid, etc.) 6) The total number of these cable sets you require. STANDARD CABLE SETS 7/8" FLEXIBLE FOAM DIELECTRIC, 50 OHM ORDER CODE Length Connector A Connector B CA106-S-N-78-78-E12 6 metres 7/8” EIA 7/8” EIA CA120-S-N-NM-NM-E12 20 metres N-Male N-Male 1/2" FLEXIBLE FOAM DIELECTRIC, 50 OHM ORDER CODE Length Connector A Connector B CA101-7-S-N-NM-NM-E11 1.75 metres N-Male N-Male CA102-S-N-NM-NM-E11 2 metres N-Male N-Male CA102-4-S-N-NM-NM-E11 2.45 metres N-Male N-Male CA102-5-S-N-NM-NM-E11 2.5 metres N-Male N-Male CA103-S-N-NM-NM-E11 3 metres N-Male N-Male CA103-S-N-NM-NF-E11 3 metres N-Male N-Female CA104-S-N-78-78-E11 4 metres 7/8” EIA 7/8” EIA CA125-S-N-NM-NM-E11 25 metres N-Male N-Male CA130-S-N-NM-NF-E11 30 metres N-Male N-Female 1/2" SUPER FLEXIBLE FOAM DIELECTRIC, 50 OHM ORDER CODE Length Connector A Connector B CA104-S-N-NM-DM-E13 4 metres N-Male 7/16” DIN Male RU400 LOW LOSS, 50 OHM ORDER CODE Length Connector A Connector B CA115-S-N-NM-NM-E7 15 metres N-Male N-Male ZCG Scalar, Head Office, 7 Hall Street, PO Box 7, Lindenow, Victoria, 3865, Australia Telephone (03) 5157-1203, Fax (03) 5157-1641 [email protected] www.zcg.com.au Section 10 COAXIAL CABLE and FITTINGS ZCG7850 7/8" Flexible Foam Dielectric Coaxial Cable, 50 Ohm Updated 23 February 2011 Compare the specifications and attenuation performance of our 7/8" flexible foam dielectric 50 ohm coaxial cable with any other brand on the market and your choice will become clear. Available in cut lengths the Order Code is ZCG7850. To reduce the price per metre purchase the full 500 metre roll; Order Code ZCG7850-500. ZCG Scalar, Head Office, 1 Hall Street, PO Box 7, Lindenow, Victoria, 3865, Australia Telephone (03) 5157-1203, Fax (03) 5157-1641 [email protected] www.zcg.com.au Section 10 COAXIAL CABLE and FITTINGS ZCG1250 ½" Flexible Foam Dielectric Coaxial Cable, 50 Ohm Updated 23 February 2011 Our ½” flexible foam dielectric 50 ohm coaxial cable has specifications and attenuation performance to match or surpass all other brands. This is a high quality cable. Look no further. Available in cut lengths the Order Code is ZCG1250. To reduce the price per metre purchase the full 500 metre roll; Order Code ZCG1250-500. ZCG Scalar, Head Office, 1 Hall Street, PO Box 7, Lindenow, Victoria, 3865, Australia Telephone (03) 5157-1203, Fax (03) 5157-1641 [email protected] www.zcg.com.au Section 10 COAXIAL CABLE and FITTINGS ZCG1250SF ½" Super Flexible Foam Dielectric Coaxial Cable, 50 Ohm Updated 23 February 2011 The specifications and attenuation performance of our ½" Super Flexible foam dielectric 50 ohm coaxial cable are comparable with any other brand available. A fine choice whenever super flexible cable is required. Available in cut lengths the Order Code is ZCG1250SF. To reduce the price per metre purchase the full 500 metre roll; Order Code ZCG1250SF-500. ZCG Scalar, Head Office, 1 Hall Street, PO Box 7, Lindenow, Victoria, 3865, Australia Telephone (03) 5157-1203, Fax (03) 5157-1641 [email protected] www.zcg.com.au Section 10 COAXIAL CABLE and FITTINGS RU400 Low Loss Coaxial Cable, 50 Ohm Updated 22 November 2011 For those longer cable runs or the higher frequency range, this 50 ohm RU400 cable will provide the low attenuation performance you require. This is a high quality cable equivalent to, and in some cases better than, all other 400 series coaxial cables available on the market today. Available in cut lengths, the Order Code is 7890. To reduce the price per metre, purchase a full roll : 7890-100 is the 100 metre roll. 7890-300 is the large 300 metre roll. Construction Specifications RU400 Low Loss 50 Ohm (7890) Centre Conductor Bare Copper, 2.74 mm Dielectric Foamed Polyethylene (PE), 7.24 mm 1st Outer Conductor Sealed APA Tape, 7.37 mm 2nd Outer Conductor Tinned Copper Braiding, 8.17 mm, 98% Coverage Jacket Black Polyethylene (PE), 10.30 mm diameter. Mechanical Specifications Minimum Bend Radius 72.1 mm Weight 14.6 kg per 100 metres Operating Temperature -40OC to +85OC Electrical Specifications Impedance 50 Ohms (± 3 Ohms) Nominal Capacitance 78 pF/m Velocity of Propogation 85% DC Resistance Inner Conductor 3.06 Ohms/km Outer Conductor 5.41 Ohms/km Loop 8.47 Ohms/km Attenuation Frequency Per 100 metres 150 MHz 5.64 dB 1000 Watts 220 MHz 6.79 dB 830 Watts 450 MHz 10.24 dB 550 Watts 900 MHz 14.72 dB 380 Watts 1500 MHz 19.21 dB 1800 MHz 21.22 dB 2000 MHz 22.66 dB 2400 MHz 25.65 dB ZCG Scalar, Head Office, 1 Hall Street, PO Box 7, Lindenow, Victoria, 3865, Australia Telephone (03) 5157-1203, Fax (03) 5157-1641 [email protected] www.zcg.com.au Maximum Power Section 10 COAXIAL CABLE and FITTINGS RU400-75 Low Loss Coaxial Cable, 75 Ohm Updated 22 November 2011 RU400-75 is a high quality 75 ohm coaxial cable which delivers excellent low attenuation performance. This cable is therefore ideally suited for those longer cable runs or the higher frequency range. Available in cut lengths, the Order Code is 8121. To reduce the price per metre, purchase the full 300 metre roll; Order Code 8121-300. Construction Specifications RU400-75 Cable, 75 Ohm (8121) Centre Conductor Solid Copper, 1.65 mm Dielectric Foamed Polyethylene (PE), 7.24 mm 1st Outer Conductor Aluminium Tape, 7.39 mm 2nd Outer Conductor Tinned Copper Braiding, 8.13 mm Jacket Black Polyethylene (PE), 10.29 mm diameter. Mechanical Specifications Minimum Bend Radius Installation : 25.4 mm. Repeated : 101.6 mm Weight 10 kg per 100 metres Operating Temperature -40OC to +85OC Electrical Specifications Impedance 75 Ohms Nominal Capacitance 52.3 pF/m Velocity of Propogation 85% DC Resistance Maximum Frequency Inner Conductor 8.20 Ohms/km Outer Conductor 7.30 Ohms/km 2,500 MHz Attenuation Frequency Per 100 metres Maximum Power 30 MHz 2.1 dB 2,990 Watts 50 MHz 2.7 dB 2,331 Watts 150 MHz 4.8 dB 1,320 Watts 220 MHz 5.8 dB 1,080 Watts 450 MHz 8.4 dB 740 Watts 900 MHz 12.1 dB 520 Watts 1,500 MHz 16.0 dB 390 Watts 1,800 MHz 17.6 dB 350 Watts 2,000 MHz 18.7 dB 330 Watts 2,500 MHz 21.1 dB 300 Watts ZCG Scalar, Head Office, 1 Hall Street, PO Box 7, Lindenow, Victoria, 3865, Australia Telephone (03) 5157-1203, Fax (03) 5157-1641 [email protected] www.zcg.com.au Section 10 RG213 MIL SPEC Coaxial Cable RF MAX Brand, 50 Ohm COAXIAL CABLE and FITTINGS Updated 23 February 2011 RG213 is a common everyday cable useful for both VHF and UHF applications. Our RF MAX brand 50 ohm RG213 MIL SPEC coaxial cable is available in either cut lengths or at a reduced price per metre by the full roll. For cut lengths per metre the Order Code is 7800. A full 100 metre roll is available. Order 7800-100. Enquire regarding the availability of the large 305 metre roll. The Order Code is 7800-300. Construction Specifications, RF MAX RG213 Cable (7800) Centre Conductor Bare Copper, 7 Strand x 0.75 mm Dielectric Solid Polyethylene (PE), 7.24 mm diameter Outer Conductor Bare Copper Braid Jacket Black Polyethylene, 10.30 mm outside diameter Mechanical Specifications Minimum Bend Radius 55.5 mm Weight 15.3 kg per 100 metres Operating Temperature -40OC to +85OC Electrical Specifications Impedance 50 Ohms (± 2 Ohms) Maximum Frequency 1 GHz Nominal Capacitance 100.7 pF/m Velocity of Propogation 66 % Attenuation Frequency Per 100 metres 50 MHz 4.80 dB 1500 Watts 100 MHz 6.68 dB 975 Watts 400 MHz 14.19 dB 450 Watts 700 MHz 22.00 dB 300 Watts 900 MHz 26.57 dB 250 Watts 1000 MHz 27.50 dB 230 Watts ZCG Scalar, Head Office, 1 Hall Street, PO Box 7, Lindenow, Victoria, 3865, Australia Telephone (03) 5157-1203, Fax (03) 5157-1641 [email protected] www.zcg.com.au Maximum Power Section 10 COAXIAL CABLE and FITTINGS RG213U Coaxial Cable Huber & Suhner Brand, 50 Ohm 500 metre roll Updated 23 February 2011 RG213 is a common everyday cable useful for both VHF and UHF applications. A recognised brand in the industry, Huber and Suhner 50 ohm RG213U coaxial cable is available in a full 500 metre roll. The Order Code is 7800-500. Construction Specifications, Huber & Suhner RG213U Cable Centre Conductor Copper, 7 Strand, 2.25 mm diameter Dielectric Polyethylene (PE), 7.28 mm diameter Outer Conductor Copper Braid, 96% Coverage, 8.1 mm diameter Jacket Black PVC II (non-migration), 10.3 mm diameter ± 0.1 Mechanical Specifications Bend Radius Static 55 mm, Repeated 100 mm (max 50 bends) Weight 15.3 kg per 100 metres Operating Temperature -40OC to +85OC Electrical Specifications Impedance 50 Ohms (± 2 Ohms) Maximum Frequency 1 GHz Capacitance 100.7 pF/m Velocity of Propogation 66 % Signal Delay 5.03 nS/m Shielding Effectiveness > 40 dB up to 1 GHz Max Operating Voltage 5 kV rms at sea level Test Voltage 10 kV rms (50 Hz/1 min) Attenuation Frequency Per 100 metres Maximum Power 50 MHz 4 dB 1860 Watts 100 MHz 6 dB 1316 Watts 200 MHz 9 dB 930 Watts 300 MHz 12 dB 760 Watts 400 MHz 14 dB 658 Watts 500 MHz 16 dB 588 Watts 600 MHz 18 dB 537 Watts 700 MHz 19 dB 497 Watts 800 MHz 21 dB 465 Watts 900 MHz 23 dB 439 Watts 1000 MHz 24 dB 416 Watts ZCG Scalar, Head Office, 1 Hall Street, PO Box 7, Lindenow, Victoria, 3865, Australia Telephone (03) 5157-1203, Fax (03) 5157-1641 [email protected] www.zcg.com.au Section 10 COAXIAL CABLE and FITTINGS RG214/U Double Shielded Coaxial Cable RF MAX Brand, 50 Ohm Updated 23 February 2011 Our RF MAX brand of double shielded 50 ohm RG214/U coaxial cable offers equivalent construction quality and performance to other “name” brands available. Compare the specifications. RG214/U is commonly used in test leads and quality installations requiring low PIM and cross talk. Available in cut lengths per metre, the Order Code is 7808. Purchase a full 100 metre roll to reduce the price per metre even further. Order 7808-100. Construction Specifications, RF MAX RG214/U Cable (7808) Centre Conductor Silver Plated Copper, 7 Strand, 2.24 mm Dielectric Solid Polyethylene (PE), 7.25 mm (± 0.02 mm) 1st Braid Coverage 96% Tinned Copper Braiding 2nd Braid Coverage 98% Tinned Copper Braiding Jacket Black PVC, 1.10 mm thick, 10.8 mm diam (± 0.10 mm) Mechanical Specifications Bend Radius Static 55 mm, Dynamic 162 mm Weight 18.5 kg per 100 metres Operating Temperature -40OC to +85OC Electrical Specifications Impedance 50 Ohms (± 3 Ohms) Maximum Frequency 6 GHz Nominal Capacitance 100 pF/m (± 3 pF/m) Velocity of Propogation 66 % Sparker Test 4,000 VAC Dielectric Strength Conductor to Shield : 10,000 VDC Attenuation Frequency Per 100 metres 100 MHz 1028 Watts 200 MHz 9 dB 727 Watts 300 MHz 12 dB 593 Watts 400 MHz 14 dB 514 Watts 500 MHz 16 dB 460 Watts 600 MHz 18 dB 420 Watts 800 MHz 21 dB 353 Watts 850 MHz 22 dB 353 Watts 900 MHz 23 dB 343 Watts 1000 MHz 24 dB 325 Watts 1800 MHz 35 dB 242 Watts 2000 MHz 38 dB 230 Watts 2400 MHz 43 dB 210 Watts 3000 MHz 50 dB 188 Watts 4000 MHz 61 dB 163 Watts 5000 MHz 72 dB 145 Watts 6000 MHz 82 dB 133 Watts ZCG Scalar, Head Office, 1 Hall Street, PO Box 7, Lindenow, Victoria, 3865, Australia Telephone (03) 5157-1203, Fax (03) 5157-1641 [email protected] www.zcg.com.au Maximum Power 5 dB Section 10 RG214/U Double Shielded Coaxial Cable Huber and Suhner Brand, 50 Ohm COAXIAL CABLE and FITTINGS Updated 23 February 2011 This double shielded 50 ohm RG214/U coaxial cable is manufactured by Huber and Suhner, a well recognised brand in the industry. RG214/U is commonly used in test leads and quality installations requiring low PIM and cross talk. Available in cut lengths, the Order Code is 8300. Construction Specifications, Huber & Suhner RG214/U Cable (8300) Inner Conductor Copper Silver Plated, Strand-07, 2.25 mm Dielectric Solid Polyethylene (PE), 7.28 mm Outer Conductor Copper Silver Plated, Braid 93% coverage, 8 mm Outer Conductor Copper Silver Plated, Braid 95% coverage, 8.7 mm Jacket Black PVC II (non migration), 10.8 mm (± 0.15 mm) Mechanical Specifications Bend Radius Static 55 mm, Dynamic 162 mm Weight 18.5 kg per 100 metres Operating Temperature -40OC to +85OC Electrical Specifications Impedance 50 Ohms (± 2 Ohms) Maximum Frequency 6 GHz Capacitance 101 pF/m Velocity of Propogation 66 % Signal Delay 5.03 nS/m Shielding Effectiveness > 71 dB up to 6 GHz Max Operating Voltage 5 kV rms at sea level Attenuation Frequency Per 100 metres 300 MHz 12 dB 593 Watts 600 MHz 18 dB 420 Watts 900 MHz 23 dB 343 Watts 1200 MHz 27 dB 297 Watts 1500 MHz 31 dB 265 Watts 1800 MHz 35 dB 242 Watts 2100 MHz 39 dB 224 Watts 2400 MHz 43 dB 210 Watts 2700 MHz 46 dB 198 Watts 3000 MHz 50 dB 188 Watts 3300 MHz 53 dB 179 Watts 3600 MHz 57 dB 171 Watts 3900 MHz 60 dB 165 Watts 4200 MHz 63 dB 159 Watts 4500 MHz 66 dB 153 Watts 4800 MHz 69 dB 148 Watts 5100 MHz 73 dB 144 Watts 5400 MHz 76 dB 140 Watts 5700 MHz 79 dB 136 Watts 6000 MHz 82 dB 133 Watts ZCG Scalar, Head Office, 1 Hall Street, PO Box 7, Lindenow, Victoria, 3865, Australia Telephone (03) 5157-1203, Fax (03) 5157-1641 [email protected] www.zcg.com.au Maximum Power Section 10 RG223 Double Silver Braided Coaxial Cable Low PIM, 50 Ohm COAXIAL CABLE and FITTINGS Updated 23 February 2011 RG223 is a double silver braided 50 ohm coaxial cable with a silver plated copper inner line. This construction delivers genuine Low PIM performance. RG223 cable is therefore an excellent choice for use in Phasing Harnesses and Cable Sets. Available in cut lengths, the Order Code is 7887. A 100 metre roll is available at a reduced price per metre. The full roll Order Code is 7887-100. Construction Specifications for RG223 Cable (7887) Inner Conductor Silver Plated Copper Wire, 0.88 mm Dielectric Solid Polyethylene (PE), 2.95 mm Outer Conductor Double Silver Braid, 3.60 mm and 4.20 mm Overall Braid Tinned Copper, 96% coverage Jacket Black PVC, 5.40 mm outside diameter Mechanical Specifications Bend Radius Once: 30 mm Weight 5.5 kg per 100 metres Repeated: 55 mm Operating Temperature -40OC to +70OC Electrical Specifications Cutoff Frequency 5 GHz Velocity of Propogation 66.3 % Signal Delay 5.03 nS/m Impedance 50 Ohms Capacitance 100.7 pF/m Shielding Effectiveness > 85 dB DC Resistance Inner Conductor: 27.7 ohms/km Outer Conductor: 6.7 ohms/km Attenuation Frequency Per 100 metres 30 MHz 8.0 dB 10 MHz 1,000 Watts 50 MHz 9.0 dB 50 MHz 450 Watts 100 MHz 10.66 dB 100 MHz 400 Watts 150 MHz 15.30 dB 200 MHz 300 Watts 220 MHz 25.20 dB 400 MHz 200 Watts 450 MHz 30.50 dB 1000 MHz 150 Watts 900 MHz 40.70 dB 3000 MHz 80 Watts 1500 MHz 55.40 dB 5000 MHz 40 Watts 1800 MHz 65.30 dB 2000 MHz 70.10 dB 2500 MHz 85.10 dB ZCG Scalar, Head Office, 1 Hall Street, PO Box 7, Lindenow, Victoria, 3865, Australia Telephone (03) 5157-1203, Fax (03) 5157-1641 [email protected] www.zcg.com.au Maximum Power Section 10 RG58 Low Loss Solid Core MIL SPEC Coaxial Cable, 50 Ohm COAXIAL CABLE and FITTINGS Updated 23 February 2011 RG58 low loss solid core MIL SPEC 50 ohm coaxial cable is particularly useful for applications such as cellular mobile phone antenna installations. A broad selection of connectors are available. Available in cut lengths, the Order Code is 7839. Otherwise, both a 100 metre and 300 metre roll are available at reduced prices per metre. The full roll Order Codes are 7839-100 and 7839-300 respectively. A WHITE jacketed RG58 low loss cable is also in stock. Order 7839W for cut lengths, or 7839W-300 for a full 300 metre roll. Construction Specifications RG58 Low Loss, 50 Ohm (7839) Centre Conductor Solid Bare Copper, 1.02 mm Dielectric Foamed Polyethylene (PE) Outer Conductor Aluminium Tape Overall Braid Tinned Copper, 95% Coverage Jacket Black Polyethylene (PE), 4.95 mm outside diameter. Mechanical Specifications Minimum Bend Radius 12.7 mm Weight 3 kg per 100 metres Operating Temperature -40OC to +85OC Electrical Specifications Impedance 50 Ohms (± 2 Ohms) Nominal Capacitance 79.7 pF/m Velocity of Propogation 80% Attenuation Frequency Per 100 metres 30 MHz Maximum Power 10 MHz 1,000 Watts 50 MHz 8.1 dB 50 MHz 450 Watts 100 MHz 12.0 dB 100 MHz 300 Watts 150 MHz 14.1 dB 200 MHz 200 Watts 220 MHz 17.1 dB 400 MHz 135 Watts 450 MHz 24.6 dB 1,000 MHz 80 Watts 900 MHz 35.0 dB 3,000 MHz 40 Watts 5,000 MHz 20 Watts 1,500 MHz 45.6 dB 1,800 MHz 50.1 dB 2,000 MHz 53.0 dB 2,500 MHz 59.5 dB ZCG Scalar, Head Office, 1 Hall Street, PO Box 7, Lindenow, Victoria, 3865, Australia Telephone (03) 5157-1203, Fax (03) 5157-1641 [email protected] www.zcg.com.au 6.3 dB Section 10 RG58A/U Stranded MIL SPEC Coaxial Cable, 50 Ohm COAXIAL CABLE and FITTINGS Updated 23 February 2011 RG58A/U Stranded MIL SPEC 50 Ohm coaxial cable is suitable for low power applications in the lower frequency range, such as UHF CB 477 MHz communications. A broad selection of connectors are available. Available in cut lengths, the Order Code is 7803. Otherwise, both a 100 metre and 300 metre roll are available at reduced prices per metre. The full roll Order Codes are 7803-100 and 7803-300 respectively. Construction Specifications RG58A/U Stranded, 50 Ohm (7803) Centre Conductor Tinned Copper, 19 Strand, each 0.18 mm Dielectric Polyethylene (PE) Overall Braid Tinned Copper Jacket Black PVC, 4.95 mm outside diameter. Mechanical Specifications Minimum Bend Radius 12.7 mm Weight 3 kg per 100 metres Operating Temperature -40OC to +85OC Electrical Specifications Impedance 50 Ohms Nominal Capacitance 93.5 pF/m Velocity of Propogation 66% Attenuation Frequency Per 100 metres 30 MHz 7.60 dB 10 MHz 1,000 Watts 50 MHz 10.90 dB 50 MHz 425 Watts 100 MHz 17.48 dB 100 MHz 290 Watts 400 MHz 33.08 dB 200 MHz 190 Watts 450 MHz 35.67 dB 400 MHz 105 Watts 700 MHz 56.20 dB 1,000 MHz 60 Watts 800 MHz 61.06 dB 3,000 MHz 25 Watts 900 MHz 65.92 dB 5,000 MHz 20 Watts 1,000 MHz 70.80 dB ZCG Scalar, Head Office, 1 Hall Street, PO Box 7, Lindenow, Victoria, 3865, Australia Telephone (03) 5157-1203, Fax (03) 5157-1641 [email protected] www.zcg.com.au Maximum Power Section 10 RG174A/U Miniature MIL SPEC Coaxial Cable, 50 Ohm COAXIAL CABLE and FITTINGS Updated 23 February 2011 RG174A/U is a miniature MIL SPEC 50 ohm coaxial cable useful for frequencies up to 1 GHz. Typical uses include connecting electronic and telecommunications equipment or measuring instruments. Available in cut lengths, the Order Code is 7877. A 500 metre roll is also available at a reduced price per metre. The 500 metre roll Order Code is 7877-500. Construction Specifications RG174A/U Miniature, 50 Ohm (7877) Centre Conductor Copper Plated 7 Strand Steel, 0.48 mm Dielectric Polyethylene (PE), 1.48 mm Overall Braid Tinned Plated Copper Jacket Black PVC, 2.80 mm outside diameter. Mechanical Specifications Minimum Bend Radius 15.0 mm Weight 1.2 kg per 100 metres Operating Temperature -40OC to +85OC Electrical Specifications Impedance 50 Ohms Nominal Capacitance 100.7 pF/m Velocity of Propogation 66% Attenuation Frequency Per 100 metres 20 dB 50 MHz 160 Watts 100 MHz 29 dB 100 MHz 80 Watts 200 MHz 42 dB 200 MHz 80 Watts 300 MHz 52 dB 400 MHz 61 dB 400 MHz 60 Watts 500 MHz 69 dB 600 MHz 76 dB 700 MHz 82 dB 800 MHz 89 dB 900 MHz 95 dB 1,000 MHz 101 dB 1,000 MHz 35 Watts ZCG Scalar, Head Office, 1 Hall Street, PO Box 7, Lindenow, Victoria, 3865, Australia Telephone (03) 5157-1203, Fax (03) 5157-1641 [email protected] www.zcg.com.au Maximum Power 50 MHz Section 10 RG316 Teflon Insulated Miniature Coaxial Cable, 50 Ohm COAXIAL CABLE and FITTINGS Updated 13 January 2012 RG316 miniature 50 ohm coaxial cable has a silver plated copper clad steel centre conductor with a teflon dielectric. Teflon insulated coaxial cable assemblies offer superior phase and high temperature stability. RG316 is frequently installed in sensitive areas with minimal space. Typical examples include avionics equipment bays, medical systems, phased antenna arrays and 2-way communication infrastructure. This cable is also particularly useful for 50 ohm data link applications up to 3 GHz. Available in cut lengths, the Order Code is 7853. Construction Specifications RG316 Miniature, 50 Ohm (7853) Centre Conductor Silver Plated Copper Clad Steel, 7 strand x 0.17 mm Dielectric Teflon PTFE, 1.52 mm Overall Braid Silver Plated Copper, 1.95 mm Jacket Teflon FEP, 2.50 mm outside diameter. Mechanical Specifications Minimum Bend Radius 13.0 mm Operating Temperature -55OC to +200OC Electrical Specifications Impedance 50 Ohms Nominal Capacitance 96.45 pF/m Velocity of Propogation 70% Maximum Voltage 1,200 VMS Maximum Frequency 3 GHz Attenuation Frequency Per 100 metres 100 MHz 26.2 dB 400 MHz 53.1 dB 1,000 MHz 85.6 dB 3,000 MHz 153.2 dB ZCG Scalar, Head Office, 7 Hall Street, PO Box 7, Lindenow, Victoria, 3865, Australia Telephone (03) 5157-1203, Fax (03) 5157-1641 [email protected] www.zcg.com.au Section 10 RG142 Teflon Insulated Miniature Coaxial Cable, 50 Ohm COAXIAL CABLE and FITTINGS Updated 13 January 2012 RG142 miniature 50 ohm coaxial cable has a silver plated copper clad steel centre conductor with a teflon dielectric. Teflon insulated coaxial cable assemblies offer superior phase and high temperature stability. RG142 is frequently installed in sensitive areas with minimal space. Typical examples include avionics equipment bays, medical systems, phased antenna arrays and 2-way communication infrastructure. This cable is also particularly useful for 50 ohm data link applications up to 8 GHz. Available in cut lengths, the Order Code is 7823. Construction Specifications RG142 Miniature, 50 Ohm (7823) Centre Conductor Silver Plated Copper Clad Steel, 0.94 mm diameter Dielectric Teflon PTFE, 2.95 mm Outer Conductor Silver Plated Copper Double Braid, 3.95 mm diameter Jacket Teflon FEP, 4.95 mm outside diameter. Mechanical Specifications Minimum Bend Radius 25 mm Operating Temperature -55OC to +200OC Electrical Specifications Impedance 50 Ohms Nominal Capacitance 96.45 pF/m Velocity of Propogation 70% Maximum Voltage 1,900 VMS Maximum Frequency 8 GHz Attenuation Frequency Per 100 metres 100 MHz 13.0 dB 400 MHz 29.0 dB 1,000 MHz 47.0 dB 3,000 MHz 89.0 dB ZCG Scalar, Head Office, 7 Hall Street, PO Box 7, Lindenow, Victoria, 3865, Australia Telephone (03) 5157-1203, Fax (03) 5157-1641 [email protected] www.zcg.com.au Section 10 RG11A/U Single Screened Coaxial Cable Huber & Suhner Brand, 75 Ohm COAXIAL CABLE and FITTINGS Updated 23 February 2011 RG11A/U is a single screened 75 ohm coaxial cable manufactured by Huber and Suhner, a well recognised brand in the industry. When compared to 75 ohm RG59B/U, this cable offers both better attenuation performance and higher power ratings. Therefore RG11A/U is the preferred choice for those longer cable runs or the higher frequency and power ranges. Available in cut lengths, the Order Code is 7801. Construction Specifications for RG11A/U Cable, 75 Ohm (7801) Inner Conductor Copper, Tinned Plated, Strand-07, 1.2 mm Dielectric Solid Polyethylene (PE), 7.25 mm Outer Conductor Copper Braid, 96% coverage, 8.1 mm Jacket Black PVC II (non-migration), 10.3 mm (± 0.1 mm) Mechanical Specifications Bend Radius Static 55 mm, Dynamic 154 mm Weight 13.3 kg per 100 metres Operating Temperature -25OC to +85OC Electrical Specifications Max Operating Frequency 1 GHz Velocity of Propogation 66 % Signal Delay 5.03 nS/m Impedance 75 Ohms Capacitance 67 pF/m Maximum Voltage 5 kV rms at sea level Attenuation Frequency Per 100 metres 4 dB 1279 Watts 100 MHz 6 dB 904 Watts 150 MHz 8 dB 738 Watts 200 MHz 9 dB 640 Watts 250 MHz 10 dB 572 Watts 300 MHz 11 dB 522 Watts 350 MHz 12 dB 483 Watts 400 MHz 13 dB 452 Watts 450 MHz 14 dB 426 Watts 500 MHz 15 dB 404 Watts 550 MHz 16 dB 386 Watts 600 MHz 17 dB 369 Watts 650 MHz 17 dB 355 Watts 700 MHz 18 dB 342 Watts 750 MHz 19 dB 330 Watts 800 MHz 20 dB 320 Watts 850 MHz 20 dB 310 Watts 900 MHz 21 dB 301 Watts 950 MHz 22 dB 293 Watts 1000 MHz 22 dB 286 Watts ZCG Scalar, Head Office, 1 Hall Street, PO Box 7, Lindenow, Victoria, 3865, Australia Telephone (03) 5157-1203, Fax (03) 5157-1641 [email protected] www.zcg.com.au Maximum Power Rating 50 MHz Section 10 RG59B/U MIL SPEC Coaxial Cable, 75 Ohm COAXIAL CABLE and FITTINGS Updated 23 February 2011 RG59B/U is a common everyday use MIL SPEC coaxial cable for 75 ohm applications, particularly television. Available in cut lengths, the Order Code is 7807. A 100 metre roll is available at a reduced price per metre. The full roll Order Code is 7807-100. Construction Specifications RG59B/U Cable, 75 Ohm (7807) Centre Conductor Bare Copper, 0.58 mm Dielectric Polyethylene (PE), 3.64 mm Overall Braid Bare Copper Jacket Black PVC, 6.10 mm outside diameter. Mechanical Specifications Minimum Bend Radius 35.0 mm Weight 5 kg per 100 metres Operating Temperature -40OC to +85OC Electrical Specifications Impedance 75 Ohms Nominal Capacitance 67.7 pF/m Velocity of Propogation 66% Attenuation Frequency Per 100 metres 8 dB 50 MHz 540 Watts 100 MHz 11 dB 100 MHz 270 Watts 200 MHz 16 dB 200 MHz 270 Watts 300 MHz 20 dB 400 MHz 23 dB 400 MHz 185 Watts 500 MHz 26 dB 600 MHz 29 dB 700 MHz 32 dB 800 MHz 34 dB 900 MHz 37 dB 1,000 MHz 39 dB 1,000 MHz 110 Watts ZCG Scalar, Head Office, 1 Hall Street, PO Box 7, Lindenow, Victoria, 3865, Australia Telephone (03) 5157-1203, Fax (03) 5157-1641 [email protected] www.zcg.com.au Maximum Power 50 MHz Section 10 COAXIAL CABLE and FITTINGS Hoisting Stocking Grips Updated 23 February 2011 Pulling coaxial cable into position has never been easier with these Hoisting Stocking Grips. Hoisting Stockings provide a reliable cable installation method which ensures neither the external cable jacket, foam dielectric or centre core is damaged during the hoisting process. These stockings are re-useable time and time again. The stocking is laced around coaxial cable over a 30 cm (1 foot) length. The single or double eyelets allow a high pulling force with the least amount of stress to the coaxial cable. Order Code : HS7850 Hoisting Stocking Grip for 7/8” Flexible Foam Dielectric Cable, Non-magnetic tin coated bronze, single eye, split mesh, lace closing. Order Code : HS1250 Hoisting Stocking Grip for 1/2” Flexible Foam Dielectric Cable or 1/2” Super Flexible Foam Dielectric Cable, Non-magnetic tin coated bronze, double eye, split mesh, lace closing ZCG Scalar, Head Office, 1 Hall Street, PO Box 7, Lindenow, Victoria, 3865, Australia Telephone (03) 5157-1203, Fax (03) 5157-1641 [email protected] www.zcg.com.au Section 10 COAXIAL CABLE and FITTINGS Bird-Proof Stainless Steel Braid Updated 24 November 2011 Birds gnawing at your antenna feeder cable can cause serious problems eventually resulting in system failure. The most effective solution is to feed vulnerable sections of cable through stainless steel braid which will provide the ultimate protection against all such bird damage. The braid ends can be secured with stainless steel hose clamps. Stainless steel bird-proof braid is highly flexible and will survive long term in the harshest of environments. ÂÂ Stainless steel braid 6 mm in diameter will suit RG58, RG59 and other smaller cables. The Order Code is 7860. ÂÂ Larger 10 mm diameter stainless steel braid is suitable for protecting ½" flexible foam dielectric, RU400, RG213 and similar size coaxial cables. The Order Code is 7860-2. ÂÂ To protect 7/8" flexible foam dielectric coaxial cable, use 22 mm diameter braid. Order Code 7860-3. This braid is available in either cut lengths or a full 25 metre roll. ZCG Scalar, Head Office, 7 Hall Street, PO Box 7, Lindenow, Victoria, 3865, Australia Telephone (03) 5157-1203, Fax (03) 5157-1641 [email protected] www.zcg.com.au 7860 7860-2 7860-3 6 mm diam 10 mm diam 22 mm diam Section 10 Snap-In Cable Hangers Packs of 10 COAXIAL CABLE and FITTINGS Updated 27 November 2011 Available in Packs of 10, stainless steel Snap-In Cable Hangers provide a simple and secure method of installing 7/8" and 1/2" flexible foam dialectric coaxial cables to a tower or mast. ÂÂ SHC7850 is the Snap-In Hanger to suit 7/8" cable. ÂÂ SHC1250 is the size suitable for either 1/2" flexible or 1/2" super flexible coaxial cable. These hangers are easily pressed over the coaxial cable jacket which is gripped tight by the curved internal fingers with no slippage. Available in Packs of 10 SHC7850 SHC1250 Next, squeeze the curled snap-in fingers, insert the hanger into a 3/4" (19 mm) hole and release the fingers. There are three typical installation methods : 1. Where there are 3/4" holes available in the tower structure, simply insert the Snap-In Hangers into those holes. The tower member can be between 3.0 and 3.4 mm thick. 2. Where there no holes available, or the tower structure is thicker than 3.4 mm, then order stainless steel Angle Adaptors which bolt to the tower. Then insert the Snap-In Hanger into the Angle Adapter. 3/4" hole (19 mm) 3. Where the coaxial cable is being installed up a round mast, then order Stand-Off Adaptors which are secured tight by a strap. Then insert the Snap-In Hanger into the Stand-Off Adaptor. 6542 Stand-Off Adaptor (available separately) Angle Adapter (available separately) The Snap-In Hanger fingers securely lock the coaxial cable in position and resist side-to-side movement in high wind conditions. They are specifically designed to eliminate inadvertant “pop-outs” due to excessive galvanised or rounded edges on tower members. The stainless steel construction of these Snap-In Cable Hangers ensures a long service life in the most extreme weather conditions and highly corrosive environments. Stand-Off Adaptor clamps for these snap-in cable hangers are available to order separately. Constructed from grade 304 stainless steel, the order code is 6542. 6542 ZCG Scalar, Head Office, 7 Hall Street, PO Box 7, Lindenow, Victoria, 3865, Australia Telephone (03) 5157-1203, Fax (03) 5157-1641 [email protected] www.zcg.com.au Section 10 COAXIAL CABLE and FITTINGS PVC Cable Hanger Clamps Packs of 10 Updated 23 February 2011 PVC Cable Hanger Clamps are a modern solution to install 7/8" and 1/2" flexible foam dielectric coaxial cables neatly. Multiple runs of coaxial cable can be stacked in space saving configurations of one, two or three parallel rows. Each compact PVC Hanger Clamp holds one run of cable. It is recommended a clamp be placed at one metre intervals. The internal cable-gripping ridges press into the cable jacket to provide firm support in heavy wind and ice loading conditions. The two piece clamps mount to threaded rod with nuts and washers. (Not supplied.) The rod can screw into the threaded hole of either a Cleat or Angle Adapter.  It is important to select rod with the correct thread size :  1. If mounting these PVC Cable Hangers to a Cleat, then you will need M8–1.25 threaded rod. 2. If mounting to Angle Adapters, then use 3/8"–16UNC threaded rod. Available in packs of 10, these cable hanger clamps are manufactured from a durable UV weather resistant polypropylene which exceeds the recommended temperature parameters for coaxial cable. M8–1.25 threaded rod will screw directly into a Cleat. 3/8"–16UNC threaded rod will suit an Angle Adapter. Please note that threaded rod, nuts and washers are NOT supplied with packs of PVC Cable Hanger Clamps. HC7850 HC1250 Pack of 10 PVC Cable Hanger Clamps to suit 7/8" flexible foam dielectric coaxial cable Pack of 10 PVC Cable Hanger Clamps to suit 1/2" flexible or super flexible foam dielectric coaxial cable ZCG Scalar, Head Office, 1 Hall Street, PO Box 7, Lindenow, Victoria, 3865, Australia Telephone (03) 5157-1203, Fax (03) 5157-1641 [email protected] www.zcg.com.au Section 10 COAXIAL CABLE and FITTINGS Angle Adapters Kits of 10 Updated 23 February 2011 When installing 7/8" or 1/2" coaxial cable into position up a tower where there are no holes available to fit Cable Hangers, then Angle Adapters will provide the ideal solution. Available in Kits of 10, Angle Adapters bolt directly to a tower member up to 22 mm thick. They lock into place with toothed jaws and the 5 cm square head 3/8"–16UNC set screw bolt supplied. There is no need to drill any holes. The Angle Adapter offers two methods of mounting different Cable Hangers: 1. Insert a stainless steel Snap-In Cable Hanger into the 3/4" (19 mm) hole in the Angle Adapter. There are two 3/4" holes available, one in the back and another in the underside. 2. If using traditional Cable Hangers or threaded rod, then an insert, spring washer and shorter 3/8"–16UNC bolt is also supplied for fitting those to the Angle Adapter. This is a heavy duty, high strength mounting solution. The stainless steel construction of these Angle Adapters ensures long term survival in the harshest of weather conditions and highly corrosive environments. Kits include 10 stainless steel Angle Adapters together with the appropriate number of bolts, washers and inserts. The Order Code is ANGLE-AD. Angle Adapters bolt directly to a tower member up to 22 mm thick.   If using traditional Cable Hangers, then an insert, spring washer and shorter 3/8”–16UNC bolt is also supplied for fitting those to the Angle Adapter. Insert a Snap-In Cable Hanger into the 3/4” (19 mm) hole. ANGLE-AD : Kit of 10 Angle Adapters, bolts, washers and inserts. ZCG Scalar, Head Office, 1 Hall Street, PO Box 7, Lindenow, Victoria, 3865, Australia Telephone (03) 5157-1203, Fax (03) 5157-1641 [email protected] www.zcg.com.au Section 10 COAXIAL CABLE and FITTINGS Cleats Packs of 10 Updated 23 February 2011 Cleats can be used to mount Cable Hangers to a tower. The Cleat bolts onto a tower member up to 22 mm thick, either flat or angle iron, and is securely locked in position by the 35 mm long M6–1.0 Hex Head Set Screw. There is no need to drill any holes. A Cleat offers two methods of mounting different Cable Hangers : 1. Mount PVC Cable Hanger Clamps to M8–1.25 threaded rod with nuts and washers. This size rod will screw directly into the matching M8–1.25 threaded hole of a Cleat. 2. If using traditional Cable Hangers, then secure these to Cleats with short M8–1.25 bolts and spring washers. There are two M8–1.25 threaded holes available in the Cleat; one in the back and another in the underside. Cleats are constructed from metal alloy. 2 x M8–1.25 threaded holes Available in Packs of 10, the Order Code is RSB-310.  Mount PVC Cable Hanger Clamps to M8–1.25 threaded rod with nuts and washers. This size rod will screw directly into the M8–1.25 threaded hole of a Cleat. ZCG Scalar, Head Office, 1 Hall Street, PO Box 7, Lindenow, Victoria, 3865, Australia Telephone (03) 5157-1203, Fax (03) 5157-1641 [email protected] www.zcg.com.au  If using traditional Cable Hangers, then secure these to Cleats with short M8–1.25 bolts and spring washers. Section 10 COAXIAL CABLE and FITTINGS Trimming Tools Updated 23 February 2011 To prepare coaxial cable for fitting connectors, these Trimming Tools make the task quick, easy and neat. ÂÂ TT7850 is suitable for preparing 7/8" flexible foam dielectric coaxial cable, ÂÂ TT1250 suits 1/2" flexible foam dielectric coaxial cable, and ÂÂ TT1250SF suits 1/2" super flexible foam dielectric coaxial cable. A spare set of blades is included with each trimming tool. TT7850 Trimming Tool for 7/8" Flexible Foam Dielectric Cable ZCG Scalar, Head Office, 1 Hall Street, PO Box 7, Lindenow, Victoria, 3865, Australia Telephone (03) 5157-1203, Fax (03) 5157-1641 [email protected] www.zcg.com.au TT1250 Trimming Tool for 1/2" Flexible Foam Dielectric Cable Section 10 COAXIAL CABLE and FITTINGS Crimp Tools for Connectors Updated 24 November 2011 Having used various brands of Crimp Tools over the years, ZCG Scalar can highly recommend these 8.7" Hex Series Tools for fitting Crimp Connectors to the more common coaxial cable types listed below. SPECIFICATIONS HT336D2 SPECIFICATIONS HT336G Crimp Tool Handle Colour Dark Blue Crimp Tool Handle Colour Green Hex Diameters ± 0.1 0.068 inch 0.213 inch 0.256 inch 0.429 inch Hex Diameters ± 0.1 0.043 inch 0.068 inch 0.100 inch 0.137 inch 0.213 inch 0.255 inch Crimp both the SLEEVE and CENTRE PIN of connectors to suit these cables RG58 RG59 RG62 RG174 RG142 RG316 Fibre Optic Crimp both the SLEEVE and CENTRE PIN of connectors to suit these cables RG58 RG59 RG62 Crimp the SLEEVE ONLY of connectors to suit these cables RG8 RG11 RG213 RU400 1.72 mm 5.41 mm 6.50 mm 10.89 mm Please note that crimp connectors for these cables will have a Solder Pin ZCG Scalar, Head Office, 7 Hall Street, PO Box 7, Lindenow, Victoria, 3865, Australia Telephone (03) 5157-1203, Fax (03) 5157-1641 [email protected] www.zcg.com.au 1.09 mm 1.72 mm 2.54 mm 3.48 mm 5.41 mm 6.48 mm Section 10 COAXIAL CABLE and FITTINGS Stainless Steel Cable Tie Tensioner Tool Updated 23 February 2011 This Stainless Steel Cable Tie Tensioner Tool will : 99 Fit stainless steel cable ties quickly and easily, 99 Set the correct predetermined tension, and 99 Neatly cut off the tail. The high quality construction ensures a long service life. Order Code : 8125 Stainless Steel Cable Tie Tensioner Tool Stainless steel cable ties offer significant benefits over the black nylon type : 99 Superior strength. 99 Ideal for use indoors, outdoors or underground. 99 Resistant to corrosion, salt, acids, chemicals, radiation, extreme temperatures and all weather conditions. 99 Install with full confidence that the Grade 316 Stainless Steel will maintain integrity over many decades. Order Code Description 8117-2 Stainless Steel Grade 316 Cable Ties, 200 mm long x 4.6 mm, Bag of 100 8117-3 Stainless Steel Grade 316 Cable Ties, 240 mm long x 4.6 mm, Bag of 100 8117 Stainless Steel Grade 316 Cable Ties, 360 mm long x 4.6 mm, Bag of 100 8117-4 Stainless Steel Grade 316 Cable Ties, 450 mm long x 4.6 mm, Bag of 100 8117-5 Stainless Steel Grade 316 Cable Ties, 600 mm long x 4.6 mm, Bag of 100 ZCG Scalar, Head Office, 1 Hall Street, PO Box 7, Lindenow, Victoria, 3865, Australia Telephone (03) 5157-1203, Fax (03) 5157-1641 [email protected] www.zcg.com.au