Preview only show first 10 pages with watermark. For full document please download

каталог продукции Zelio Count (pdf 1408 Kb) (, 1.37 Mb)

   EMBED


Share

Transcript

5/0 Contents 0 5 - Zelio Count - counters Selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5/2 1 Presentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5/4 Electromechanical and electronic totalising counters 1 Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5/6 1 References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5/7 Electronic totalising counters, hour counters, chronometers 24 x 48, 6 or 8 digits, LCD 1 Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5/8 1 References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5/9 Electronic totalising counters, 24 x 48, 8 digits, LCD 1 Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5/10 1 References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5/11 Electronic total/partial impulse counters, 24 x 48, 8 digits, LCD 1 Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5/12 1 References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5/13 Electromechanical preset counters, 5 digits 1 Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5/14 1 References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5/15 Electromechanical and electronic totalising timers 1 Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5/16 1 References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5/17 Electronic hour counters, 24 x 48, 6 digits, LCD 1 Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5/18 1 References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5/19 Electronic preselection and multifunction counters, 48 x 48, 6 digits, LCD or LED 1 Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5/20 1 References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5/21 5/1 5 Selection guide 5 5 Zelio Count - counters 5 Function Totalising counters Display type Mechanical Font panel dimensions (h x w) in mm 20 x 30 31 x 41.5 50 x 60 24 x 48 Number of display digits 6 digits 5 or 6 digits (depending on model) 6 or 6 digits (depending on model) 8 digits Maximum counting frequency 25 Hz 10 or 20 Hz (depending on model) 10 or 25 Hz (depending on model) 30 Hz or 7.5 kHz 40 Hz or 7.5 kHz Input type Contact Volt-free contact or transistor Volt-free Voltage contact, level transistor or voltage level Output type – Reset type Without Manual or without (depending on model) Manual or without Manual or transistor Manual, volt-free contact or transistor Supply voltage 1 24 V 1 24 V, 1 48 V, 2 115 V 1 24 V, 2 115 V Lithium battery Display capacity 0...999 999 0...99 999 or 0...9 999 999 (depending on model) 0...999 999 or 0...99 999 999 (depending on model) Time ranges – Number of presets or partial count – References XBK XBK T60000U00M T50000U11M XBK T70000U00M Pages 5/7 5/2 LCD Manual or voltage level 0...99 999 999 XBK XBK RC RC T60000U11M T81030U33E 87 610 340 87 610 050 XBK T80000U00M 5/9 5/11 5 Total/partial impulse counters Preselection counters 5 Hour counters Mechanical Mulltifunction: - preselection, - tachometer, - chronometer, - totalising counter, - batch counter. LCD LCD or LED 48 x 48 75 x 60 48 x 48 24 x 48 5 digits 7 digits 8 digits 14 or 100 Hz 25 Hz – Volt-free contact, transistor or voltage level (depending on model) Contact (20 VA / 220 V / 1A max) Contact Contact (volt free) – Manual or Manual and electrical Without 1 24 V 2 24 V, 2 115 V, 2 230 V 0...99 999 – Manual and volt-free contact and transistor or voltage (depending on model) 0...99 999 999 (0...999 999 for partial counting) 0...99 999.99 h 1 – RC 87 610 240 RC 87 610 250 XBK P50100110M XBK H70000001M 5/13 5/15 5/17 6 digits 5 kHz or 2.5 kHz if counting on 2 inputs Volt-free contact Voltage level or transistor Volt-free contact Transistor or voltage 1 or 2 transistors and 1 or 2 changeover relays Transistor or manual with electrical interlocking facility Manual or voltage level Manual, volt-free contact or transistor Manual, electrical or automatic 1 24 V, 2 115 V, 2 230 V Lithium battery - 99 999...999 999 0...999 999.99 h 0…99 999.9 h 0…99 999.9 min 0…99 999.9 s 0…99 h 59 min 59 s 1 or 2 XBK H81000033E RC 87 610 150 RC 87 610 440 XBK P61130G31E 5/19 5/9 5/21 5/3 5 Presentation 5 Zelio Count - counters Introduction Counters, associated with detection products (photo-electric detectors, inductive sensors, limit switches, etc) or dialogue products (pushbuttons, selector switches, etc) can be used to provide an additional control system function: counting. Functions Counters complement the range of display units and operator dialogue terminals by offering simple display and entry functions. They are fully compatible with detection and human-machine interface products. Technologies The range is divided into two technologies: - electromechanical, which is more suitable for slow counting applications of around 10 Hz, - electronic (LCD or LED display) which is suitable for counting frequencies of around 1 kHz. The Zelio count range covers all counting functions. There are various product families: - totalising counters, - preselection counters, - hour counters, - tachometers, - batch counters. . 5 Totalising counters Totalising counters are used for counting events from electrical pulses or contacts. The value is displayed and updated in increments at each new pulse or contact. They are unidirectional. Applications 1 In automatic mode The totalising counter performs this function in conjunction with a photo-electric detector, inductive sensor or limit switch, which detects the passing of a part and translates this by adding one unit to the number of parts counted by the totalising counter. 1 In manual mode The totalising counter performs this operation in conjunction with a pushbutton. Pressing the button adds one unit to the value displayed. This system can be used with a ticket dispenser or a manual assembly station. Preselection counters Preselection counters are used for counting events from electrical pulses or contacts. The value is displayed and updated by adding or subtracting at each new pulse. They allow manual entry of a preset value. When this preset value is reached, they send an electrical signal. They can be used for upcounting or downcounting. Supply Applications Signals Stop belt 5/4 Limit switch Upcounting or downcounting the number of parts. The preselection counter counts the number of parts in the same way as a totalising counter. When the selected value is reached, the preselection counter, in conjunction with various sensors, sends a signal to trigger actions such as stopping a machine or conveyor belt. 5 Presentation (continued) 5 Zelio Count - counters 5 Hour counters Hour counters (also called timers or chronometers) are used to count and display times in different formats and with different modes depending on the type of counter used. Oven Applications 1 Duration of an oven heating time, 1 Use of a machine, n time and in hours, in order to perform maintenance. Tachometers Tachometers are used for measuring speed (linear or rotary), rates (in minutes or hours) or flow (volumetric). The tachometer receives pulses at a frequency to be measured. A scale factor allows the required values to be displayed (speeds, rates, flows, etc.) Applications 1 Automatic control of conveyor belt speed, 1 Flow measurement, Batch counters Batch counters are used for counting a number of parts per batch and counting a total number of batches; they send a signal each time the preset value is reached. Example OUT 2 Supply In B In A Stop belt OUT 1 On a packing line, 50 capsules are to be counted into containers and 10 containers placed into a carton. P1 : number of batches (10) P2 : number of capsules (50). Example: packing 50 capsules per container and grouping 10 containers in cartons. 5/5 5 Characteristics 5 Zelio Count - counters 5 Electromechanical and electronic totalising counters Counter type Display type XBK T totalising counters Mechanical Electronic LCD Totalising counter with mechanical display Totalising counter with LCD display Characteristics Function Supply voltage V Consumption W/VA Maximum counting frequency Hz 1 24 ± 10 % 1 48 ± 10 % 2 115 ± 10 % Lithium battery XBK T50000U10M and XBK T50000U08M – and XBK T70000U00M: 1.5 XBK T50000U11M and XBK T60000U10M and XBK T80000U00M: 2.5 XBK T60000U11M: 2.75 XBK T60000U00M: 0.155 10, 20, 25 30 or 7500 Backup capacity Permanent 7 years Number of digits 5, 6, 7 or 8 8 Display capacity 5 digits: 0…99 999 6 digits: 0…999 999 7 digits: 0…9 999 999 8 digits: 0…99 999 999 4 8 digits: 0…99 999 999 Counting mode Adding Reset type Manual or without Adding (Input resistance: 50 Ω) Manual or transistor with Reset key locking facility Digit height Inputs 5 mm Function Counting Type Contact Amplitude 7 31 41 Volt-free contact or transistor: 5 V or NPN 0.7 V PNP ± 40 V max 1 V – – ms 10 except XBK T60000U10M and XBK T80000U00M : 200 – Conforming to standards EN 50081-2, EN 50082-2 Product certifications cUR us except XBK T60000U00M EN 50081-2, EN 50082-2 EN 61010 – Mechanical life (in millions of pulses) Minimum pulse time 15 at 30 Hz, 0.07 at 7.5 kHz Environment Temperature Operation °C - 10…+ 50 except XBK T60000U00M: - 10...+ 70 Storage °C - 20…+ 60 except XBK T60000U00M: - 40…+ 85 Degree of protection Conforming to IEC/EN 60529 IP 40 except XBK T60000U00M: IP 65 IP 54 Vibration resistance Conforming to IEC/EN 60068-2-6 5 gn (10 to 150 Hz) 1 gn (10 to 150 Hz) Shock resistance Conforming to IEC/EN 60068-2-27 30 gn (6 ms) 10 gn (18 ms) Protection against electric shocks Mounting and fixing Conforming to IEC/EN 60536 Class II Connection References : page 5/7 5/6 Dimensions : page 5/7 Flush-mounting Flush-mounting housing, fixed by a clamp By AMP lugs on a connection box Screw terminal block Schemes : page 5/7 Zelio Count - counters References, dimensions, schemes 5 Electromechanical and electronic totalising counters 5 References 560825 560824 Supply voltage Number of display digits V Maximum counting frequency Hz Reset type Reference Weight kg Counters with mechanical display XBK T50000U11M 1 24 5 20 Manual XBK T50000U10M 0.100 6 25 Without XBK T60000U00M 0.030 25 Manual XBK T60000U10M 0.150 7 20 Without XBK T70000U00M 0.100 8 25 Without XBK T80000U00M 0.150 5 20 Without XBK T50000U08M 0.100 5 10 Manual XBK T50000U11M 0.100 6 10 Manual XBK T60000U11M 0.030 Manual or transistor XBK T81030U33E 0.050 560827 560826 XBK T60000U00M 5 1 48 2 115 XBK T70000U00M 802818 560828 XBK T60000U1 M Counters with LCD display Lithium battery 8 30 or 7500 XBK T81030U33E XBK T80000U00M Dimensions XBK T50000U11M, XBK T70000U00M Flush-mounting Flush-mounting XBK T60000U00M e 20 27 31 38,5 75 XBK T60000U11M 27 42,3 88 94 29,5 50 38 60 +0,2 Common flush-mounting 50 38 XBK T80000U00M 88 101,5 5 30 33,7 41,5 64,2 14,2 e 60 = = 55 Flush-mounting XBK T81030U33E 24 22+0,3 e 32 48 40 45+0,6 e: panel thickness, 1 mm < e < 2.5 mm Schemes XBK T50000U11M, XBK T70000U00M –/+ XBK T80000U00M, XBK T60000U11M + XBK T60000U10M + XBK T80000U00M 1 PNP 1 2 2 2 – + Reset key locking facility 1 1 –/+ XBK T81030U33E 2 – + – – 4 3 2 1 Reset Count 0V Keylock 4 3 2 1 Reset Count 0V Keylock 4 3 2 1 Reset Count 0V Keylock Volt-free contact NPN 4 3 2 1 Reset Count 0V Keylock Characteristics : page 5/6 5/7 Characteristics 5 Zelio Count - counters Electronic totalising counters, hour counters, chronometers, 24 x 48, 6 or 8 digits, LCD Counter type RC 87 610 340 RC 87 610 440 Impulse counter Solid state 8 digit LCD 7 0…99 999 999 – Hour counter/chronometer Solid state 6 digit LCD 7 – 0…99 999.9 h 0…99 999.9 min 0…99 999.9 s 0…99 h 59 min 59 s Quartz (precision ± 50 ppm) Yes 5 years Technical characteristics Functions Solid state input Display Digit height Counting capacity Time ranges mm – – 8 years Time base Possibility of reloading current value Supply Life 1 lithium battery Input characteristics Volt-free contact Slow input In.L Volt-free contact or transistor 5 Fast input In.H – Maximum counting frequency T OFF T ON Current output Leakage current in OFF state Residual voltage NPN collector Maximum counting frequency T OFF T ON Level 0 Level 1 Current consumption Hz ms ms µA µA V NPN open collector ms kHz µs µs V V mA Reset to zero : Reset Enable reset 40 max 12 min 12 min 52 max 0.2 max 0.4 max – 7 max 70 min 70 min 0…1 4…30 6 max at 24 V Volt-free contact or transistor 12 minimum Front panel 1 1 1 1 Start/Stop input 40 ms minimum (terminals 3-5) 1 Reset input 100 ms minimum (terminals 1-3) 1 Prog. input (terminals 3-4) 1 enable Reset input (terminals 1-2) – – – – – – – – – – – – – 100 minimum Electromagnetic environment characteristics Radiated field Fast transients Damped oscillatory wave Electrostatic discharge Conforming to IEC 1000-4-3 Conforming to IEC 1000-4-4 Conforming to IEC 255-4 Conforming to IEC 1000-2-6 Level 3, 10 V/M, 26 MHz to 1 GHz Level 3, 1 kV Level 3, 1 kV Level 3, 8 kV Operating characteristics Conforming to standards Product certifications Material Connection by screw terminals on back of the device Clamping capacity Fixing Degree of protection Temperature limits Operation Storage References : page 5/9 5/8 Dimensions : page 5/9 mm2 °C °C VDE 0110, IEC 664, 348, 255.4, 255.5, 801.2, 801.4 cULus, CSA Self-extinguishing 5 terminals 2 x 1.5 By yoke IP 64 0…+ 55 - 25…+ 70 Schemes : page 5/9 5 Zelio Count - counters References, dimensions, schemes 5 5 Electronic totalising counters, hour counters, chronometers, 24 x 48, 6 or 8 digits, LCD References 1 1 2 2 1 2 2 Totalising counters, LCD 24 x 48 Description Reference Impulse counter RC 87 610 340 Weight kg 0.060 Hour counter/chronometer RC 87 610 440 0.060 560814 8 or 6 digits LCD display, digit height 7 mm Totalising counter: 7 kHz and 40 Hz inputs maximum counting capacity : 99 999 999 impulses Hour counter/chronometer: start/stop inputs 4 time ranges: - 99 999.9 hours - 99 999.9 min - 99 999.9 s - 99 h 59 min 59 s 1 Powered by lithium battery: 2 reset from front panel or remote reset Accessories RC 87 610 340 Description Dimensions Adaptors for panel cut-out Reference Weight kg 0.006 0.008 0.011 25 x 50 mm (dimensions 29 x 54 mm) RC 26 546 829 45 x 45 mm (dimensions 52 x 52 mm) RC 26 546 830 Ø 50 mm (dimensions Ø 73 mm) RC 26 546 831 Dimensions RC 87 610 140 Panel cut-out 48 + 0,5 44,8 - 0 44,6 5 20 22 RC 26 546 829 RC 26 546 830 RC 26 546 831 52 54 73 48 3,5 8 48 Ø4,4 Ø8,4 24 24 52 24 48 29 30 + 0,3 -0 24 37,3 21,8 3,2 60 ˚ 60 ˚ Schemes RC 87 610 340 1 2 3 4 RC 87 610 440 5 5 4 2108 En.R 4 In. H Reset Terminals 1 - Reset input 2 - Enable Reset 3 - Slow counting 4 - 0V 5 - Fast counting 2 3 4 3 2108 2108 H 2 1 Enable Reset input Start/Stop input Prog. Reset 1,4,5 5 2108 2 In. L 1 Slow counting input and reset 3,1 4 Fast counting input Enable Reset input 2108 H Enable Prog. Reset Reset Start/Stop 100 ms Terminals 1 - Reset input 2 - Enable Reset 3 - Common 4 - Prog. 5 - Start/Stop Characteristics : page 5/8 5/9 Characteristics 5 Zelio Count - counters Electronic totalising counters, 24 x 48, 8 digits, LCD Technical characteristics Function Display Digit height Counting capacity mm Impulse counter 8 digit LCD 7 0…99 999 999 Input characteristics Counter type Input type Voltage Terminals 4 - 5 Terminals 5 - 6 V V RC 87 610 050 1 slow counting input / 5…50 48…240 V V Inhibited Enabled / 5…50 48…240 Hz 40 ms ms V kΩ 12 12 2 1 2 Reset characteristics (1) Front panel Voltage DIP switch n° 2 to OFF DIP switch n° 2 to ON Terminals 2 - 3 Terminals 1 - 2 2 1 2 Counting speed characteristics Counting speed (slow counting) Slow counting (minimum impulse duration) Low level High level Input levels Input impedance 1 4…30 3.5 min Supply characteristics 5 2 alkaline batteries 1 lithium battery Life Life 4 years 8 years Supply can be switched off via DIP switch n° 1 located on the underside of the device General characteristics Conforming to standards Product certifications Material Connection Clamping capacity Mounting method Front panel degree of protection Temperature limits Operation Storage Insulation resistance Conforming to IEC 255.5 Dielectric strength Conforming to IEC 255.5 mm2 °C °C MΩ VDE 0110, IEC 664, 348, 255.4, 255.5, 801.2, 801.4 cULus, CSA Self-extinguishing By 6 screw terminals on back of the device 2 x 1.5 By yoke IP 66 -10…+ 55 -20…+ 70 100 ( 500 V) 2000 V/50 Hz/1 min 1 (1) The reset is galvanically isolated from the counting input. References : page 5/11 5/10 Dimensions : page 5/11 Schemes : pages 5/11 and 5/23 5 Zelio Count - counters References, dimensions, schemes 5 Electronic totalising counters, 24 x 48, 8 digits, LCD 5 References 560812 1 LCD display, 8 digits, digit height 7 mm 1 Powered by alkaline batteries or lithium battery 1 Counting inputs : solid state (3 4…30 V) or voltage (up to 3/4 240 V) 1 Dimensions DIN - 24 x 48 mm 1 Reset on front panel or external with inhibit facility Totalising counters, LCD 24 x 48 Description Reference Voltage input, lithium battery Weight kg 0.065 RC 87 610 050 Accessories Description Dimensions Adaptors for panel cut-out RC 87 610 050 Reference 25 x 50 mm (dimensions 29 x 54 mm) RC 26 546 829 Weight kg 0.002 45 x 45 mm (dimensions 52 x 52 mm) RC 26 546 830 0.008 Ø 50 mm (dimensions Ø 73 mm) 0.011 RC 26 546 831 Dimensions RC 87 610 050 Panel cut-out (Max. thickness 10 mm) 1 unit 48 + 0,6 30 44,8 - 0 + 0,3 -0 44,6 20 22 24 64 21,8 3 4 units 5 RC 26 546 829 RC 26 546 830 52 54 48 3,5 73 8 48 Ø4,4 Ø8,4 24 24 52 24 48 29 RC 26 546 831 60 ˚ 60 ˚ Schemes (other schemes on page 5/23) RC 87 610 050 1 2 3 48. 5. 240V 50V a a/c Reset inputs 4 5 6 48. 5. 50V 240V a/c 2 21 Terminals 1 - Reset 48…240 V 2 - 0 V reset 3 - Reset / 5…50 V 4 - / 5…50 V 5-0V 48…240 V 6- 21 26 a Start/stop inputs Characteristics : page 5/10 5/11 Characteristics, schemes Zelio Count - counters 5 Electronic total/partial impulse counters, 24 x 48, 8 digits, LCD Technical characteristics Function Display Digit height Counting capacity Impulse counter 8 digit LCD 7 0…99 999 999 mm Input characteristics Counter type Input type Minimum time closed Voltage Terminals 4 - 5 Terminals 5 - 6 ms V V RC 87 610 240 1 counting input by volt-free contact or NPN or PNP open-collector transistor (terminals 3 - 4) 40 – – RC 87 610 250 1 galvanically isolated counting input ms V V Partial counter always enabled Volt-free contact or NPN or PNP open-collector transistor (terminals 1 - 2) 40 40 – / 5…50 – 48…240 Hz ms ms ms ms 14 or 100 35 35 5 5 – 2 / 1 5…50 2 48…240 Reset to zero characteristics (1) Front panel External (total counter) Minimum time closed Voltage Terminals 2 - 3 Terminals 1 - 2 2 1 2 Counting input characteristics Counting speed (selectable with DIP switch n° 4) Slow counting (minimum Low level impulse duration) High level Fast counting (minimum Low level impulse duration) High level 5 14 Supply characteristics 1 lithium battery Life 5 years Supply can be switched off via DIP switch n° 3 located on the underside of the device General characteristics Conforming to standards Product certifications Material Connection Clamping capacity Fixing Front panel degree of protection Temperatures Operation Storage (1) The reset is galvanically isolated from the counting input. VDE 0110, IEC 664, IEC 48, IEC 255.4, IEC 255.5, IEC 801.2, IEC 801.4 cULus, CSA Self-extinguishing By 6 screw terminals on back of the device 2 x 1.5 By yoke IP 66 - 10…+ 55 - 20…+ 70 mm2 °C °C Schemes (other schemes on pages 5/22 and 5/23) RC 87 610 240 1 2 3 4 RC 87 610 250 5 6 1 NC NC Counting inputs 5/12 a/c General reset inputs Terminals 1 - General reset input 2 - General reset common 3 - Count common 4 - Counting 5 - Not connected 6 - Not connected References : page 5/13 3 48. 5. 240V 50V a General reset inputs 2 2 21 4 5 6 48. 5. 50V 240V a/c a Counting inputs Terminals 48…240 V 1 - Reset 2 - General reset common 3 - Reset / 5…50 V 4 - / 5…50 V 5 - Count common 648…240 V 21 26 Dimensions : page 5/13 5 Zelio Count - counters References, dimensions 5 5 Electronic total/partial impulse counters, 24 x 48, 8 digits, LCD References 1 Partial or total count display 1 Counting capacity : 2 partial : 0…999 999 2 total : 0…99 999 999 1 Counting inputs and reset inputs : 2 RC 87 610 240 : solid state 2 RC 87 610 250 : voltage 1 Decimal point 1 Integral module for voltage inputs (4 / 3 5…50 V, 4 48…240 V) 1 Powered by lithium battery. Life : 5 years 1 Front panel reset for "partial" count 1 Front panel or electrical reset for total count 1 Accessories for panel cut-out 25 x 50, 45 x 45, Ø 50 Total/partial impulse counters, LCD 24 x 48 Description Reference Solid state input RC 87 610 240 Weight kg 0.060 Voltage input RC 87 610 250 0.065 560813 Accessories Description Dimensions Adaptors for panel cut-out Reference 25 x 50 mm (dimensions 29 x 54 mm) RC 26 546 829 Weight kg 0.002 45 x 45 mm (dimensions 52 x 52 mm) RC 26 546 830 0.008 Ø 50 mm (dimensions Ø 73 mm) 0.011 RC 87 610 240 RC 26 546 831 Dimensions RC 87 610 210 Panel cut-out (Max. thickness 10mm) 1 unit 48 + 0,6 RC 26 546 829 20 RC 26 546 831 52 48 73 8 48 Ø4,4 Ø8,4 24 24 52 24 3,5 60 Characteristics : page 5/12 5 + 0,3 -0 22 RC 26 546 830 54 48 29 30 44,8 - 0 44,6 24 64 21,8 3 4 units ˚ 60 ˚ Schemes : page 5/12 5/13 Characteristics 5 Zelio Count - counters Electromechanical preset counters, 5 digits Counter type Display type XBK P5 preset counters Mechanical Characteristics Function Preset counters Supply voltage V 1 24 ± 10 % Consumption W 2.5 Maximum counting frequency Hz 25 Number of digits 5 Display capacity 0 to 99 999 Digit height 5 mm 4 Number of presets 1 Preset display Adding (continuous) or subtracting (non continuous) Counting mode Adding or subtracting Reset Adding from zero or subtracting from the preset value Reset type Manual or manual and electrical Type of input signals Contact (20 VA/220 V/1 A max) Output type Contact (volt-free) Connection By AMP lugs on a connection box Environment Conforming to standards EN 50081-2 and EN 50082-2, EN 61010 Product certifications Temperature 555 55M : CSA (pending) 555 55M : UL/CSA (pending) Operation °C XBK P5 D XBK P5 U - 10…+ 50 Storage °C - 40…+ 85 Degree of protection Conforming to IEC 60529 IP 40 Vibration resistance Conforming to IEC 60068-2-6 5 gn (10 to 150 Hz) Shock resistance Conforming to IEC 60068-2-27 30 gn (6 ms) Protection against electric shocks Mounting and fixing Conforming to IEC 60536 Class II References : page 5/15 Dimensions : page 5/15 5/14 Removable and flush-mounting Fixing by screws on front panel Schemes : page 5/15 5 Zelio Count - counters References, dimensions, schemes 5 Electromechanical preset counters, 5 digits 5 560838 References Supply voltage V Number Counting Number of of display frequency presets digits Hz Reset type Reference Weight kg Subtracting preset counters with mechanical display 1 24 5 25 1 XBK P50100D10M 0.200 Manual and electrical XBK P50100D20M 0.240 Manual XBK P50100U10M 0.200 Manual and electrical XBK P50100U20M 0.240 560839 XBK P50100D10M Manual Adding preset counters with mechanical display 1 24 5 25 1 XBK P50100U50M Dimensions XBK P50100U10M Common flush-mounting 5 60 55 75 63 88,5 102,2 60 4 88,5 102,2 75 63 4 XBK P50100D10M = = 55 Schemes XBK P50100D10M, XBK P50100U10M + 1 31 2 1 22 21 31 2 20 32 32 21 20 22 – Characteristics : page 5/14 5/15 Characteristics 5 Zelio Count - counters 5 Electromechanical and electronic totalising timers Timer type Display type XBK H totalising timers Mechanical Electronic LCD Totalising timer with mechanical display Totalising timer with LCD display Characteristics Function Supply voltage V Consumption VA 2 24 ± 10 % 50 Hz 2 115 ± 10 % 50 Hz 2 230 ± 10 % 50 Hz Lithium battery – Backup capacity XBK H70000001M: 0.56 XBK H70000002M: 1 XBK H70000004M: 0.08 Permanent Number of digits 7 8 Precision of display 0 to 99 999.99 h 0 to 999 999.99 h 5 7 Digit height mm Counting mode Adding 1/100 of an hour Reset type Without Inputs 7 years Manual or transistor with Reset key locking facility Function Enable Type Contact Transistor: PNP – ± EN 50081-2, EN 50082-2, VDE 0435 UR recognized EN 50081-2, EN 50082-2 EN 61010 – Amplitude V 1 40 V max 3 1 5 V or NPN 4 1 0.7 V Environment Conforming to standards 5 Product certifications Temperature Operation °C - 10…+ 50 Storage °C - 25…+ 70 - 20…+ 60 Degree of protection Conforming to IEC/EN 60529 IP 65 IP 54 Vibration resistance Conforming to IEC/EN 60068-2-6 3 gn (10 to 150 Hz) 1 gn (10 to 150 Hz) Shock resistance Conforming to IEC/EN 60068-2-27 30 gn (11 ms) 10 gn (18 ms) Protection against electric shocks Mounting and fixing Conforming to IEC/EN 60536 Class II Flush-mounting unit fixed by a self-locking clamp Connection References : page 5/17 5/16 Screw terminal block Dimensions : page 5/17 Zelio Count - counters References, dimensions, schemes 5 Electromechanical and electronic totalising timers 5 References 560844 Supply voltage Number of display digits V Mains supply frequency Hz Reset type Reference Weight kg Timers with mechanical display 2 24 7 50 Without XBK H70000004M 0.060 2 115 7 50 Without XBK H70000001M 0.060 2 230 7 50 Without XBK H70000002M 0.060 Number of display digits Display mode Reset type Reference XBK H70000001M 802818 Supply voltage V Weight kg Timers with LCD display Lithium battery 8 XBK-H81000033E 1/100 of an hour Manual or transistor XBK H81000033E 0.050 Dimensions XBK H70000001M Flush-mounting 5 48 45 e 48 54,5 62,5 45 e: panel thickness, 1 mm < e < 2.5 mm Flush-mounting XBK H81000033E 24 22+0,3 e 32 48 40 45+0,6 Schemes XBK H81000033E Reset key locking facility + PNP – + 4 3 2 1 Reset Count 0V Keylock 4 3 2 1 Reset Count 0V Keylock Reset Count 0V Keylock Volt-free contact NPN – 4 3 2 1 4 3 2 1 Reset Count 0V Keylock Characteristics : page 5/16 5/17 Characteristics 5 Zelio Count - counters Electronic hour counters, 24 x 48, 6 digits, LCD Technical characteristics Function Display Digit height Time ranges mm Time base Possibility of reloading current value Hour counter 6 digit LCD 7 0…99 999.9 h 0…99 999.9 min 0…99 999.9 s 0…99 h 59 min 59 s Quartz (precision ± 50 ppm) Yes Input characteristics Counter type Input type Voltage Minimum impulse time Terminals 4 - 5 Terminals 5 - 6 2 1 V V ms ms RC 87 610 150 1 start/stop input / 5…50 48…240 - 50/60 Hz 50 35 ms V V Inhibited Enabled 100 / 5…50 48…240 - 50/60 Hz 2 1 2 Reset characteristics (1) Front panel Minimum impulse time Voltage DIP switch n° 2 to OFF DIP switch n° 2 to ON Terminals 2 - 3 Terminals 1 - 2 2 1 2 Supply characteristics 1 lithium battery 5 Life 5 years Supply can be switched off via DIP switch n° 1 located on the underside of the device General characteristics Conforming to standards Product certifications Material Temperature limits Operation Storage Front panel degree of protection Mounting method Connection Clamping capacity (1) The reset is galvanically isolated from the counting input. References : page 5/19 5/18 Dimensions : page 5/19 °C °C VDE 0110, IEC 664, 348, 55.4, 255.5, 801.2, 801.4 cULus, CSA Self-extinguishing -10…+ 55 -20…+ 70 mm2 IP 66 By yoke By 6 screw terminals on back of the device 2 x 1.5 Schemes : page 5/19 5 Zelio Count - counters References, dimensions, schemes 5 Electronic hour counters, 24 x 48, 6 digits, LCD 5 References 1 Counting inputs and reset inputs : solid state or voltage Hour counters, LCD 24 x 48 1 Integral module for voltage inputs(4 or 3 5…50 V, Description 4 48…240 V) Solid state input 1 4 time ranges : 2 99 999.9 h - 99 999.9 min 2 99 999.9 s - 99 h 59 min 59 s 1 Possibility of reloading current value 1 Powered by lithium battery. Life 5 years 1 Reset on front panel or external with inhibit facility Accessories 560815 Description Reference RC 87 610 150 Dimensions Adaptors for panel cut-out Weight kg 0,065 Reference Weight kg 0.002 0.008 0.011 25 x 50 mm (dimensions 29 x 54 mm) RC 26 546 829 45 x 45 mm (dimensions 52 x 52 mm) RC 26 546 830 Ø 50 mm (dimensions Ø 73 mm) RC 26 546 831 RC 87 610 150 Dimensions RC 87 610 150 Panel cut-out (Max. thickness 10 mm) 1 unit 48 30 44,8 + 0,3 -0 44,6 20 22 24 64 21,8 3 4 units + 0,6 -0 5 RC 26 546 829 RC 26 546 830 73 52 54 48 3,5 48 8 24 48 Ø8,4 24 24 Ø4,4 52 29 RC 26 546 831 60 ˚ 60 ˚ Schemes (other schemes on page 5/23) RC 87 610 150 1 2 3 48. 5. 240V 50V a a/c A Reset inputs 4 5 6 48. 5. 50V 240V a/c 2 21 Terminals 1 - Reset 48…240 V 2 - Reset common 3 - Reset / 5…50 V 4 - / 5…50 V 5 - Start/stop common 48…240 V 6- 21 26 a B Start/stop inputs Characteristics : page 5/18 5/19 Characteristics 5 Zelio Count - counters Electronic preselection and multifunction counters, 48 x 48, 6 digits, LCD or LED Counter type Display type Preselection XBK P6 LCD or LED Characteristics Functions Mulltifunction Supply voltage Preselection counters, tachometer, chronometer, totalising counter, batch counter. V Sensor supply voltage Consumption Maximum counting frequency Hz 5000 (2500 for bi-directional counting) Number of digits 6 Display capacity - 99 9999 to 999 999 Digit height 5 1 24 or 2 230 ± 10 % or 2 115 ± 10 % 1 12 to 24 (50 mA max) for XBK P65530G32E or XBK P65530G31E 150 mA 1 24 V, 50mA 2 230 V or 2 115 V mm 7.6 (LED) or 9 (LCD) Number of presets 1 or 2 Preset display Non continuous Counting mode Reset 5 programmable modes : - single counter input, - single counter with phase discriminator, - differential inputs, - summing inputs, - counting direction inputs. (Counter input resistance 5 kΩ) 2 modes : reset to zero and reset to preset value Reset type Manual, electrical and automatic Output type Relay,changeover (response time 5 ms) : 5 V < Uc < 30 V 5 V < Uc < 250 V 10 mA < I < 1 A 12…24 V, 10 mA max Transistor PNP : 17 at 30 Hz 0.1 at 5 KHz 1 2 Minimum duration of counting pulse ms 1 2 1 Environment Conforming to standards EN 50081-2 and EN 50082-2, EN 61010 Product certifications cURus Temperature Operation °C - 0…+ 50 Storage °C - 20…+ 70 Degree of protection Conforming to IEC 60529 IP 65 Vibration resistance Conforming to IEC 60068-2-6 1 gn (10 to 150 Hz) Shock resistance Conforming to IEC 60068-2-27 10 gn (18 ms) Protection against electric shocks Mounting and fixing Conforming to IEC 60536 Class II Flush-mounting unit and fixing by a self-locking clamp with setscrews Connection References : page 5/21 5/20 Screw terminal block Dimensions : page 5/21 Schemes : page 5/21 5 Zelio Count - counters References, dimensions, schemes 5 Electronic preselection and multifunction counters, 48 x 48, 6 digits, LCD or LED 5 References 560820 Supply voltage Number of display digits V Counting frequency Number of presets Reference kHz Weight kg Manual, electrical and automatic reset Preselection counters with LCD display 1 24 2 115 2 230 560821 XBK P61130G31E 6 5 6 5 6 5 1 2 1 2 1 2 XBK P61130G30E XBK P61230G30E XBK P61130G31E XBK P61230G31E XBK P61130G32E XBK P61230G32E 0.150 0.150 0.250 0.250 0.250 0.250 XBK P62130G30E XBK P62230G30E XBK P62130G32E XBK P62230G32E 0.150 0.150 0.250 0.250 Preselection counters with LED display 1 24 2 230 XBK P62130G31E 6 5 6 5 1 2 1 2 Dimensions XBK P61130G31E Flush-mounting 48 45 e 5 48 93,5 45 101,7 Schemes XBK P61130G31E c 12 V + c 24 V c 24 V + 2-wire sensor types XS, XU 1 3 2-wire sensor types XS, XU XBK P61130G31E default configuration (PNP) R = 1 kΩ 0V – 1 Load 2 a 230 V a 115 V 3 XBK P61130G31E default configuration (PNP) 2 0V – 2-wire sensor types XS, XU 2 10 to 30 V 1 Power supply R = 1 kΩ 10 3 XBK P61130G31E or G31E default configuration (PNP) 2 c 24 V + 11 2-wire sensor or photocell relay or limit switch or pushbutton a a 230 V a 115 V 5-wire sensor types XS, XU 1 (NO) or (NC) a 13 A1 Control relay A2 type CA2 Common 10 1 17 14 3 XBK P61130G31E default configuration (PNP) 3 XBK P61130G31E or G31E default configuration (PNP) 11 0V – 2 16 Characteristics : page 5/20 5/21 Schemes 5 Zelio Count - counters Counters 24 x 48 Connection schemes RC 87 610 240 Description Fast counting input Voltage 4-30 V Counting and general reset input 3 4 + Volt-free contact 2 1 NPN transistor or 3-wire NPN proximity sensor (1) 4-30 V + 3 2 4 1 NPN 0V PNP transistor or 3-wire PNP proximity sensor (1) 5 2 1 2-wire proximity sensor 4-30 V 4 R (2) 3 0V 4-30 V 4 R (2) 0V (1) For sensor with leakage current ≤ 0.1 mA. (2) R = 470 Ω / 2 Ω for a 2-wire sensor with leakage current ≤ 1.5 mA. References : page 5/13 5/22 3 5 Schemes (continued) 5 Zelio Count - counters 5 Counters 24 x 48 Connection schemes (continued) RC 87 610 050, RC 87 610 150, RC 87 610 250 Description Counting input RC 87 610 050, RC 87 610 250 Start/Stop input RC 87 610 150 Reset RC 87 610 050, RC 87 610 150, RC 87 610 250 Voltage 4 ~ 5-50 V / 48-240 V 48-240 V 5 ~ 1 ~ 2 ~ 5-50 V / 6 3 Live contact 4 ~ 48-240 V~ 5-50 V /= NPN transistor or 3-wire NPN proximity sensor (1) 48-240 V 5 1 ~ 2 ~ 5-50 V / 6 5-50 V 3 5-50 V + + PNP 4 3 2 5 0V PNP transistor or 3-wire PNP proximity sensor (1) PNP 0V 5-50 V 5-50 V + 4 + 3 2 5 0V 0V 2-wire proximity sensor 30 V 5 NPN NPN 30 V max max 3 4 R (2) R (2) 2 5 0V 0V 30 V maxi 30 V maxi 4 3 R (2) 0V R (2) 5 0V 2 (1) For sensor with leakage current ≤ 0.1 mA. (2) R = 470 Ω / 2 Ω for a 2-wire sensor with leakage current ≤ 1.5 mA. References : pages 5/11 to 5/19 5/23