Preview only show first 10 pages with watermark. For full document please download

Zip-usb-mp Interface Between A Usb Port And An Mp

   EMBED


Share

Transcript

Operating instructions ZIP-USB-MP ZIP-USB-MP Interface between a USB port and an MP interface Table of Contents Safety note 2 Product features 2 Power supply Driver Master/monitor mode switch Connection Functions of the LEDs Technical data 2 2 2 2 2 2 Wiring diagrams 3 Local connection via the service socket on the MF/MP or LON actuator with ZK1-GEN cable Local connection via the connection cable on the MF/MP or LON actuator with ZK2-GEN cable Connection to the MP-Bus with ZK2-GEN cable Connection to the MP-Bus via the MP master with ZKS-MP cable www.belimo.com T9-ZIP-USB-MP • en • v1.2 • 08.2010 • Subject to changes 3 3 4 5 /5 .. .. . ZIP-USB-MP Operating instructions Safety note ! For connecting to PC USB ports and BELIMO 24 V actuators (supplied with SELV or US class 2 voltage) only. Product features The ZIP-USB-MP is a potential-free interface between the USB port on a PC and the BELIMO MP-Bus. It is used to connect the Belimo PC-Tool either to the MP-Bus or directly to a parameterisable MFT actuator. .. .. .. Power supply Driver Master/monitor mode switch .. .. .. .. .. .. .. . Note For devices without slide switch the mode switching is made by BELIMO PC-Tool. The ZIP-USB-MP is supplied with voltage by the USB port. A driver must be installed on the PC in order to use the ZIP-USB-MP. This driver can be downloaded from the Belimo website (Download section). Once the driver has been installed, the ZIPUSB-MP is logged in on the PC as a virtual COM port. Master mode (MA position of the slide switch) The slide switch on the ZIP-USB-MP must be set to “MA” (master = factory setting) in order to configure and parameterise the actuators with the Belimo PC-Tool. MP-Bus monitor mode (MO position of the slide switch) The slide switch on the ZIP-USB-MP must be set to “MO” (monitor) in order to carry out analyses and diagnostics on the MP-Bus (“MP-Bus monitoring”). Connection The connection for the USB cable is located on the USB side. An USB 2.0 cable with an A to B connector (length 1 m) is supplied with the ZIP-USB-MP. On the MP bus side of the device are two female connectors connected in parallel (1 x 3-pole Weidmüller socket, 1x RJ12 socket). The connector that is used depends on the application. Pin configuration Functions of the LEDs Technical data .. .. .. Operating temperature: Non-operating temperature: EMC: Connection: Driver: Weight: /5 PJ12 Pin 1: MP-bus Pin 2: Enable Pin 3: GND Pin 1: not connected Pin 2: GND Pin 3: not connected Pin 4: MP Pin 5: Enable Pin 6: not connected Initialized Device has been initialized by the PC (Windows) Data Flashes when MP-Bus is communicating Enable PC-Tool is MP-Master .. .. .. Weidmüller 0 … +50° C, non-condensing –40 … +80° C CE according to 2004/108/EC USB 2.0: USB connection cable (length 1 m) with A to B plug supplied MP-bus: Belimo ZK… connection cable according to the pin configuration Latest version on the BELIMO website 160 g (incl. USB cable) T9-ZIP-USB-MP • en • v1.2 • 08.2010 • Subject to changes www.belimo.com ZIP-USB-MP Operating instructions Wiring diagram 1 Local connection via the service socket on the MF/MP or LON actuator with ZK1-GEN cable USB USB 2.0 cable with A to B plug RJ11 (4/6) ZK1-GEN BELIMO PC-Tool Note The mode switch must be set to “MA” (master). 24 V GND USB ..A-MF ..A-MP ..D2-MP ..ALON ..D2LON 2 1 Wiring diagram 2 USB USB 2.0 cable with A to B plug ~ T Local connection via the connection cable on the MF/MP or LON actuator with ZK2-GEN cable AC 24 V _ + DC 24 V RJ11 (4/6) ZK2-GEN BELIMO PC-Tool MP white = GND GND green = MP blue not connected Note The mode switch must be set to “MA” (master). USB 1 5 2 ~ T ..LON ..MFT(2) A-MF ..ALON ..A-MP ..D2LON ..D2-MP U5 / MP _ + Wiring diagram 3 Connection to the MP-Bus with ZK2-GEN cable Mode switch set to “MA” (master) The mode switch on the ZIP-USB-MP must be set to “MA” (master = factory setting) in order to use the PC-Tool as the MP master. – To parameterise actuators via the MP-Bus – To select setpoints for simulating actuators via the MP-Bus – To link sensors connected to the MP actuators – To record graphic trends USB USB 2.0 cable with A to B plug Pos. MA = Master RJ11 (4/6) MP-Master DDC Controller UK.. Gateway ZK2-GEN BELIMO PC-Tool GND 24 V MP white = GND green = MP blue not connected GND USB Connection to master interrupted MP more actuators (max. 8) 1 2 ..A-MP ..D2-MP ..MFT(2) www.belimo.com 5 1 2 ..A-MP ..D2-MP ..MFT(2) 5 1 2 ..A-MP ..D2-MP ..MFT(2) T9-ZIP-USB-MP • en • v1.2 • 08.2010 • Subject to changes 5 1 2 ..A-MP ..D2-MP ..MFT(2) 5 1 2 ..A-MP ..D2-MP ..MFT(2) 5 1 2 5 ..A-MP ..D2-MP ..MFT(2) /5 ZIP-USB-MP Operating instructions Wiring diagram 4 Connection to the MP-Bus with ZK2-GEN cable Mode switch set to “MO” (monitor) The mode switch on the ZIP-USB-MP must be set to “MO” (monitor) in order to use the PC-Tool as an MP analyser for diagnostics in the MP-Bus network. – To test MP communication with the MP-Monitor Tool (module of PC-Tool V3.x) USB USB 2.0 cable with A to B plug Pos. MO = Monitor RJ11 (4/6) MP-Master DDC Controller UK.. Gateway ZK2-GEN BELIMO PC-Tool GND 24 V MP white = GND green = MP blue not connected GND Note The mode switch must first be set to “MO” before the MP-Monitor can be opened in the PC-Tool. USB MP more actuators (max. 8) 1 2 ..A-MP ..D2-MP ..MFT(2) /5 5 1 2 ..A-MP ..D2-MP ..MFT(2) 5 1 2 ..A-MP ..D2-MP ..MFT(2) T9-ZIP-USB-MP • en • v1.2 • 08.2010 • Subject to changes 5 1 2 ..A-MP ..D2-MP ..MFT(2) 5 1 2 ..A-MP ..D2-MP ..MFT(2) 5 1 2 5 ..A-MP ..D2-MP ..MFT(2) www.belimo.com ZIP-USB-MP Operating instructions Wiring diagram 5 Connection to the MP-Bus via the MP master with ZKS-MP cable Mode switch set to “MA” (master) Connection to the MP-Bus via the MP master mit Kabel ZKS-MP Mode switch set to “MO” (monitor) The mode switch on the ZIP-USB-MP must be set to “MA” (master = factory setting) in order to use the PC-Tool as the MP master. – To parameterise actuators via the MP-Bus – To select setpoints for simulating actuators via the MP-Bus – To link sensors connected to the MP actuators – To record graphic trends The mode switch on the ZIP-USB-MP must be set to “MO” (monitor) in order to use the PC-Tool as an MP analyser for diagnostics in the MP-Bus network. – To test MP communication with the MP-Monitor Tool (module of PC-Tool V3.x) UK 24LON /EIB USB MFT -H Pos. MA = Master Pos. MO = Monitor USB 2.0 cable with A to B plug MP-Com . 0V 24V Y U /MP LonTalk a b BELIMO PC-Tool Power 0V 24V n.c. 3 pol ~ T AC 24 V _ + DC 24 V Note The mode switch must first be set to “MO” before the MP-Monitor can be opened in the PC-Tool. ZKS-MP USB more actuators (max. 8) 1 2 ..A-MP ..D2-MP ..MFT(2) www.belimo.com 5 1 2 ..A-MP ..D2-MP ..MFT(2) 5 1 2 ..A-MP ..D2-MP ..MFT(2) T9-ZIP-USB-MP • en • v1.2 • 08.2010 • Subject to changes 5 1 2 ..A-MP ..D2-MP ..MFT(2) 5 1 2 ..A-MP ..D2-MP ..MFT(2) 5 1 2 5 ..A-MP ..D2-MP ..MFT(2) /5