Zk1090-9191-3xxx_en

   EMBED


Share

Transcript

Data sheet V1.0│ZK1090-9191-3xxx EtherCAT-Cable RJ45 plug, straight – RJ45 plug, straight PVC, 1x4xAWG26, fixed installation Connector Electrical data Rated voltage Rated current (ethernet) Shield Insulation resistance Mechanical data Installation size (M12, M8,...) Connector type (plug, socket) Configuration (straight, angled, open end) Contact type (male, female) Number of positions (face) Mating cycles Body color Body material Contact carrier color Contact material Contact plating Environmental data Operation temperature range in °C (°F) Protection level Head 1 8-pole, 160 V (according to IEC 61076-2-101) 1 A at 50°C yes ≥10 GΩ (according to IEC 60512-2) Head 1 RJ45 plug Head 2 8-pole, 160 V (according to IEC 61076-2-101) 1 A at 50°C yes ≥10 GΩ (according to IEC 60512-2) Head 2 RJ45 plug straight straight male 8 ≥750 black PC UL 94 V0 black CuZn Ni, Au gal. male 8 ≥750 black PC UL 94 V0 black CuZn Ni, Au gal. -40°C…+85°C (-40°F…185°F) -40°C…+85°C (-40°F…185°F) IP20 IP20 Beckhoff® and EtherCAT are registered trademarks of Beckhoff. Information is subject to change without notice and warranted only to the extent agreed in the terms of contract. Beckhoff Automation GmbH & Co.KG, Huelshorstweg 20, 33415 Verl, Germany, Tel.: +49 (0) 5246 963 0, Fax.: +49 (0) 5246 963 149, http://www.beckhoff.com Page 1 of 3 Data sheet V1.0│ZK1090-9191-3xxx Cable Electrical data Rated voltage Attenuation of shielding Insulation resistance Capacity unbalanced to ground Mutual capacitance Characteristic impedance Loop resistance Unbalanced resistance Test voltage wire/wire Test voltage wire/shield Signal running time Electrical parameters Mechanical data Cable structure Conductor construction Cross section max. Bending radius, moved max. Bending radius, fixed installation Weight Cable outer diameter Conductor material Optical covering factor of shielding Shielding Wall thickness of wire insulation Wall thickness of jacket Jacket color Jacket material Wire insulation material Wire insulation material Printing on the jacket Printing color Environmental data Operation temperature range, fixed installation Acid, lye and solvent resistance Other characteristics approvals 300 V ≥43 dB ≥500 MΩ/km 1600 pF/km 52 nF/km 100 Ω ± 5Ω (100MHz, EN 50289-1-11) 280 Ω/km 2% 2000 V 2000 V 5.3 ns/m Cat 5e, according to EN50288-2-2 star quad 7 x0.167 mm 0.14 mm² (AWG26) 7 x cable outer diameter 5 x cable outer diameter 33 kg/km (72.75 lb/1000ft) 4.9 mm ± 0.2 mm (0.193" ±0.0079”) copper 80 % Aluminium-clad foil, braiding of tinned copper wires 0.25 mm 0.85 mm green PVC (polyvinylchloride) white, yellow, blue, orange PE (polyethylene) "sequential length in metres" Industrial Ethernet Cat5 flex *E130266 AWM STYLE 2464 80 °C 300V *ZB9030 “month/year” “internal order number” black -40 °C up to 80 °C (-40 °F up to 176 °F) depends on medium, concentration, temperature and time flame resistant according to IEC60332-1-2, free from halogen according to DIN VDE 0472 part 815 UL-Style 2464 Beckhoff® and EtherCAT are registered trademarks of Beckhoff. Information is subject to change without notice and warranted only to the extent agreed in the terms of contract. Beckhoff Automation GmbH & Co.KG, Huelshorstweg 20, 33415 Verl, Germany, Tel.: +49 (0) 5246 963 0, Fax.: +49 (0) 5246 963 149, http://www.beckhoff.com Page 2 of 3 Data sheet V1.0│ZK1090-9191-3xxx Pinout Illustration A1 = B1 = 44.60 mm 44.60 mm Ordering information ZK1090-9191-3050 cable length (L) 5.00 m Beckhoff® and EtherCAT are registered trademarks of Beckhoff. Information is subject to change without notice and warranted only to the extent agreed in the terms of contract. Beckhoff Automation GmbH & Co.KG, Huelshorstweg 20, 33415 Verl, Germany, Tel.: +49 (0) 5246 963 0, Fax.: +49 (0) 5246 963 149, http://www.beckhoff.com Page 3 of 3