MN2400 Size: AAA (LR03)
PLUS
Alkaline-Manganese Dioxide Battery
3.8 mm Max
10.5 mm 9.5 0.8 mm MIN. (+)
Nominal Voltage:
1.5 V
Operating Voltage
1.6 - 0.75V
Impedance:
250 m-ohm @ 1kHz
Typical Weight:
11 gm (0.4 oz.)
Typical Volume:
3.5 cm 3 (0.2 in.3 )
Terminals: Storage Temperature Range:
Flat o o -20 C to 35 C
Operating Temperature Range:
o o -20 C to 54 C o o (-4 F to 130 F)
ANSI: IEC:
24A LR03
44.5 mm 43.2
TYPICAL DISCHARGE CHARACTERISTICS AT 21°C (70°F) (–)
1.6 5.1 OHMS
1.5
Dimensions shown are IEC standards
10 OHMS 24 OHMS
1.4
43 OHMS 75 OHMS
Voltage
1.3 1.2 1.1 1 0.9 0.8
Berkshire Corporate Park Bethel, CT 06801 U.S.A. Telephone: Toll-free 1-800-544-5454 Internet: www.duracell.com
0
10
20
30
40
50
60
70
80
Service Hours
* Delivered capacity is dependent on the applied load, operating temperature and cut-off voltage. Please refer to the charts and discharge data shown for examples of the energy / service life that the battery will provide for various load conditions.
This data is subject to change. Performance information is typical. Contact Duracell for the latest information
6/08
90
Size: AAA (LR03)
PLUS
Alkaline-Manganese Dioxide Battery
TYPICAL CONSTANT CURRENT DISCHARGE CHARACTERISTICS AT 21°C (70°F) 1.6
10000 1.1 V 1.0 V 0.9 V
1000
TYPICAL DISCHARGE CHARACTERISTICS AT 21°C (70°F) 1.00 A
1.5
0.75 A
100
Voltage
Service Hours
Zn/MnO2
MN2400
10
1.4
0.50 A
1.3
0.25 A
1.2 1.1 1
1
0.9 0.1 1
10
100
0.8
1000
0
0.5
Discharge Current (mA)
1
1.5 2 2.5 Service Hours
3
3.5
4
TYPICAL DISCHARGE CHARACTERISTICS AT 21°C (70°F) 1.6
1.00 W
Voltage
1.5
0.75 W
1.4
0.50 W
1.3
0.25 W
TYPICAL DISCHARGE PERFORMANCE AT 21°C (70°F) 1.2
1.2
1
Amp Hours
1.1 1 0.9 0.8 0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
4 H/D
1 H/D
1 H/D
30 M/D
100
250
500
0.2
TYPICAL DC RESISTANCE CHARACTERISTICS AT 21°C (70°F) Low drain: 0.06A/1hr - 0.3A/1sec High drain: 0.6A/5min - 1.2A/1sec
1.6
0.6 0.4
0.9
Amp Hours
1.8
0.8
0 50
1.8
Discharge Current (mA) 1.6
Low drain 1.4 1.2
1.2 High drain
1
1
0.8
0.8
0.6
0.6
0.4
0.4
Low drain
0.2
0.2
High drain
0 0%
10%
20%
30%
40% 50% 60% Depth of Discharge
70%
80%
90%
DC Resistance
Closed Circuit Voltage
1.4
Berkshire Corporate Park Bethel, CT 06801 U.S.A. Telephone: Toll-free 1-800-544-5454 Internet: www.duracell.com
0 100%
* Delivered capacity is dependent on the applied load, operating temperature and cut-off voltage. Please refer to the charts and discharge data shown for examples of the energy / service life that the battery will provide for various load conditions.
This data is subject to change. Performance information is typical. Contact Duracell for the latest information
6/08