Zn/MnO2 MN2400 Size: AAA (LR03) PLUS Alkaline-Manganese Dioxide Battery 3.8 mm Max 10.5 mm 9.5 0.8 mm MIN. (+) Nominal Voltage: 1.5 V Operating Voltage 1.6 - 0.75V Impedance: 250 m-ohm @ 1kHz Typical Weight: 11 gm (0.4 oz.) Typical Volume: 3.5 cm 3 (0.2 in.3 ) Terminals: Storage Temperature Range: Flat o o -20 C to 35 C Operating Temperature Range: o o -20 C to 54 C o o (-4 F to 130 F) ANSI: IEC: 24A LR03 44.5 mm 43.2 TYPICAL DISCHARGE CHARACTERISTICS AT 21°C (70°F) (–) 1.6 5.1 OHMS 1.5 Dimensions shown are IEC standards 10 OHMS 24 OHMS 1.4 43 OHMS 75 OHMS Voltage 1.3 1.2 1.1 1 0.9 0.8 Berkshire Corporate Park Bethel, CT 06801 U.S.A. Telephone: Toll-free 1-800-544-5454 Internet: www.duracell.com 0 10 20 30 40 50 60 70 80 Service Hours * Delivered capacity is dependent on the applied load, operating temperature and cut-off voltage. Please refer to the charts and discharge data shown for examples of the energy / service life that the battery will provide for various load conditions. This data is subject to change. Performance information is typical. Contact Duracell for the latest information 6/08 90 Size: AAA (LR03) PLUS Alkaline-Manganese Dioxide Battery TYPICAL CONSTANT CURRENT DISCHARGE CHARACTERISTICS AT 21°C (70°F) 1.6 10000 1.1 V 1.0 V 0.9 V 1000 TYPICAL DISCHARGE CHARACTERISTICS AT 21°C (70°F) 1.00 A 1.5 0.75 A 100 Voltage Service Hours Zn/MnO2 MN2400 10 1.4 0.50 A 1.3 0.25 A 1.2 1.1 1 1 0.9 0.1 1 10 100 0.8 1000 0 0.5 Discharge Current (mA) 1 1.5 2 2.5 Service Hours 3 3.5 4 TYPICAL DISCHARGE CHARACTERISTICS AT 21°C (70°F) 1.6 1.00 W Voltage 1.5 0.75 W 1.4 0.50 W 1.3 0.25 W TYPICAL DISCHARGE PERFORMANCE AT 21°C (70°F) 1.2 1.2 1 Amp Hours 1.1 1 0.9 0.8 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 4 H/D 1 H/D 1 H/D 30 M/D 100 250 500 0.2 TYPICAL DC RESISTANCE CHARACTERISTICS AT 21°C (70°F) Low drain: 0.06A/1hr - 0.3A/1sec High drain: 0.6A/5min - 1.2A/1sec 1.6 0.6 0.4 0.9 Amp Hours 1.8 0.8 0 50 1.8 Discharge Current (mA) 1.6 Low drain 1.4 1.2 1.2 High drain 1 1 0.8 0.8 0.6 0.6 0.4 0.4 Low drain 0.2 0.2 High drain 0 0% 10% 20% 30% 40% 50% 60% Depth of Discharge 70% 80% 90% DC Resistance Closed Circuit Voltage 1.4 Berkshire Corporate Park Bethel, CT 06801 U.S.A. Telephone: Toll-free 1-800-544-5454 Internet: www.duracell.com 0 100% * Delivered capacity is dependent on the applied load, operating temperature and cut-off voltage. Please refer to the charts and discharge data shown for examples of the energy / service life that the battery will provide for various load conditions. This data is subject to change. Performance information is typical. Contact Duracell for the latest information 6/08