Overview ZXR10 3900A series L3 Intelligent Ethernet switches are box-like 1RU-high layer 3 routing switches. ZXR10 3900A series switches provide high density of FE Ethernet ports, complete L2 switching and L3 routing functionalities and enhanced POE/POE+ ability, which enable them to be deployed as access or convergence devices for intelligent campus networks. ZXR10 3900A Series L3 Intelligent Ethernet ZXR10 3900A offers the following switch Switch types: 3928A: 24*FE RJ45 + 2*GE SFP + 1*expansion slot
ZXR10 3928A
3928A-PS: 24*FE RJ45 POE/POE+ + 2*GE SFP + 1*expansion slot
ZXR10 3928A-PS
3928A-FI: 24*FE SFP + 2*GE SFP + 1*expansion slot
ZXR10 3928A-FI
3952A: 48*FE RJ45 + 4*GE SFP The expansion card slot can be equipped with one of following types of cards:
ZXR10 3952A
1*GE RJ45&1*GE SFP 2*GE RJ45 2*FE SFP 2*GE SFP
Advanced Features ZXR10 3900A has complete L2 switching and L3 routing capabilities; it supports POE, stacking and comprehensive security and reliability related features.
Full Service Support
ZXR10 3900A series switches support diversified VLAN features, including SuperVLAN, QinQ, selective QinQ, VLAN translation and PVLAN.
VLAN translation can be used to separate and distinguish services, while PVLAN can help restrict direct L2 communication between downlink ports.
QinQ and selective QinQ enable the administrator to distinguish users and services at the access side effectively.
ZXR10 3900A supports routing mechanisms including static routing, RIP, OSPF, IS-IS and BGP.
Multicast-based technologies like video-surveillance and videoconference are becoming more and more popular these days. ZXR10 3900A fully supports L2/L3 multicast, including IGMP snooping, Filtering, Proxy and Fastleave, MVR (Multicast VLAN Registration) and PIM-SM to facilitate the deployment of these services.
ZXR10 3900A supports MCE (multi-vrf CE), which means the capability to simulate multiple CEs to reduce the number of CE devices and reduce interface requirement for PE. Each virtual CE is separated from other virtual CE. User isolation and security guarantee can be implemented by multi-vrf CE.
Super Extensible Stacking
ZXR10 3900A supports super extensible stacking function; a working stack can accept new members or delete existing ones without service interruption. Network extensibility is enhanced as the user can freely increase the capacity of a single logical network node. N+1 redundancy for the master switch helps avoid single-point failure and reduce service breakdown. ZXR10 3900A series switch can provide long-distance (up to 120km) stacking solution. Access interfaces from different member switches can be used to form a logical smart group, fully leveraging the capacity of each single switch member and increasing the flexibility of network design.
Intelligent Power over Ethernet
All the electrical access interfaces of ZXR10 3928A-PS support POE and POE+, which go in line with 802.3af and 802.3at standards, and are compatible with PD equipment that doesn't support 802.3af and 802.3at. For POE, the power output per single interface can reach 15.4W; For POE+, the power output per single interface can reach 30W.
ZXR10 3900A supports assigning time-ranges for POE. During the time when power output is unnecessary, the POE function can be turned off to save energy for the customer.
Enhanced Reliability
Loop detection allows the switch to detect possible loops without the need to enable STP.
With UDLD (uni-Directional Link Detection), uni-directional link failure caused by wiring mistake or port failure can be detected.
ZXR10 3900A fully supports 802.3ad LACP (link aggregation control protocol) to provide redundancy in case link failure happens, and to broaden bandwidth.
When deployed in layer 2 environment, ZESR/ZESR+ (ZTE Ethernet Smart Ring) and ZESS (ZTE Ethernet Smart Switching) can be used to implement fast switchover in case of single point failure.
ZXR10 3900A supports both close ring ZESR and open ring ZESR+, which are both very good network redundancy solutions in ring topology networks.
ZESS is a very simple yet effective means to realize dual-homing purpose.
Compared with STP, the biggest advantage is that the link will switch and recover quickly when one way is disconnected and the switchover can be done in 50ms. ZESR/ZESR+ supports VLAN load balancing to enable efficient utilization of redundant links.
Enhanced Security
ZXR10 3900A supports diversified mechanisms to guarantee the security of the network:
CPU DDOS (Distributed Denial of Service) protection capability helps the equipment to mitigate the influence caused by attacks. The equipment itself won't be brought down, which ensures the network stability.
DAI (Dynamic ARP inspection) function and IP/MAC binding help prevent against DOS (Denial of Service) attacks.
802.1X can be used for authentication purpose. Working together with a policy server, the user control policy can be applied to 3900A after the authentication is done. Bandwidth limit/Qos strategy can thus be implemented automatically.
Enhanced routing protocol communications, including simple password test and MD5 authentication can be used to prevent the alteration of routing protocol interactions.
Traffic mirroring/analyzing functions like RMON (remote monitoring), SPAN (switched port analyzer), RSPAN (remote switched port analyzer) and sFlow help analyze real-time network condition.
Technical Specification Functions and Parameters Fixed interfaces Interface Combination
Basic
Expansion card (Number of expansion card slots*Type of expansion card) Backplane Capacity
3928A
3928A-PS
3928A-FI
3952A
24 FE RJ45 ports+2 GE SFP ports
24 FE RJ45 ports (POE/POE+)+2 GE SFP ports
24 FE SFP ports+2 GE SFP ports
48 FE RJ45 ports+4 GE SFP ports
1*(1 GE RJ45 port+1 GE SFP port)/1*2 GE RJ45 ports/1*2 FE SFP ports/1*2 GE SFP ports
48Gbps
48Gbps
48Gbps
-
48Gbps
Functions and Parameters Parameters
Features
Equipment Management
Physical Parameters
Switching Capacity Packet Forwarding Rate Route table Depth(host route number +subnet route number) MAC table Depth
3928A
3928A-PS
3928A-FI
3952A
12.8Gbps
12.8Gbps
12.8Gbps
17.6Gbps
9.6Mpps
9.6Mpps
9.6Mpps
13.2Mpps
4K+8K
16K
L2 Features
IEEE 802.1q VLAN, IEEE 802.1p, IEEE 802.3ad, STP, RSTP, MSTP, Selective QinQ, VLAN translation, PVLAN, DHCP Snooping, 802.1x
L3 Features
Static routing, RIP, OSPF, ISIS, BGP, MCE
Multicast
Administratively scoped multicast/IPTV, MVR, IGMP, IGMP Snooping, Filtering, Proxy and Fast Leave, PIM-SM, MSDP
QoS
Marking, modification of Qos priority and mapping between 802.1p, IP DSCP. 8 hardware-based queues per port, SP, WRR, SP+WRR queue scheduling mechanisms, Policing/shaping based on port/flow, Congestion avoidance mechanisms including WRED and Tail-Drop
Security
CPU anti-attack, CPU overload protection, Broadcast/Multicast/unknown Unicast suppression, STP Root Guard, BPDU guard, uRPF, RIP/OSPF/BGP MD5 encryption checking, IP source Guard
Reliability
LACP, ZESS, ZESR/ZESR+, VRRP
Enhanced Features
MFF,
Local management
RS232 Console (RJ45), Ethernet management port, CLI, Telnet, SSH, Local and remote(Radius/Tacacs+)authentication of user, Web management, SNMP, NetNumen U31, Cluster Management (ZGMP)
Stacking
MFF, Stacking, POE/POE+
MFF,
Stacking
MFF,
Stacking
43.6mm *442mm *280mm
43.6mm *442mm *280mm
43.6mm *442mm *280mm
43.6mm *442mm *360mm
Maximum Weight
3.5kg
5.9kg
4kg
4.5kg
DC power supply
-48V
-57V~-48V(POE:-5 7V~-48V,
-48V
-48V
Dimensions (H*W*D)
Functions and Parameters
3928A
3928A-PS
3928A-FI
3952A
100V~240V,
100V~240V,
50Hz~60Hz
50Hz~60Hz
20W
25W
180W RPS(Redundant Power Supply):
180W RPS(Redundant Power Supply):
AC/DC Input :100V~240V /-48V,
AC/DC Input :100V~240 V/-48V,
DC Output:+12V
DC Output:+12V
POE+:-57V~-53V) 100V~240V, 50Hz~60Hz; AC power supply
100V~240V, 50Hz~60Hz
1100W RPS Power Supply AC Input: 100V~240V, DC Output :-55V~-53 V
Maximum power consumption
Power redundancy pattern
Heat dissipation pattern Heat dissipation Temperature, humidity Working altitude MTBF/MTTR
15W
-
785W (Among which system power 65W, POE power output 720W)
-
Cooling without Fan
Fan cooling
Fan cooling
Fan cooling
49 BTU/h
182 BTU/h
56 BTU/h
70 BTU/h
Working temperature: -5oC ~+45oC,
humidity:10%~90%
<3000 meters > 100000 hours/ < 30 minutes