Transcript
ZWS Series Single Output, 3.3W to 50W Power Supplies Features u Universal Input (85 - 265VAC) u Input transient protected u 2 year warranty u High quality design u Peak Power capability
Key Market Segments & Applications
Specifications ZWS5 ZWS10
Model AC Input Voltage range DC Input Voltage range Inrush Current (100/200VAC) (1) Temperature Coefficient Overcurrent Protection (2) Overvoltage Protection Hold Up Time (Typ) @ 100VAC Remote Sense Operating Temperature Operating Temperature Storage Temperature Humidity (non condensing) Cooling Withstand Voltage
A V ms °C °C °C -
Isolation Resistance Vibration (non operating) Shock Safety Agency Approvals Conducted & Radiated Recommended EMI Filter
EM -
Weight (Typ) Size (WxHxD) Warranty
g mm yrs
ZWS15 ZWS50 ZWS30 85-265VAC (47-440Hz) 110 - 330VDC 15 / 30 <0.02%/ºC ~125% ~140% diode clamp ~115 - 130%, manual reset 17 None (open frame) -10ºC~+60ºC, derate linearly to 70% load from 50ºC~60ºC (with cover) Additional derating applies, please consult Installation Manual -30 to +85ºC 10 - 95% RH Convection Input to Ground 2kVAC (20mA), Input to Output 3kVAC (20mA), Output to Ground 500VAC (100mA) for 1 min. >100M at 25°C & 70%RH, Output to Ground 500VDC 10 - 55Hz (1 minute sweep), 19.6m/s2 constant X, Y, Z 1 hour < 196.1 m/s2 UL60950-1, CSA60950-1, EN60950-1, CE Mark EN55022-B, FCC Class B, VCCI-B RSEL-20R5W RSEL-2001W RSEL-2002W RSEL-2002W 120/120 140/270 370 See Outline Drawings 2 years
Notes: (1) 25°C ambient (cold start) (2) Avoid prolonged operartion in overload
1-800-526-2324 • www.us.tdk-lambda.com/lp/
113
Disclaimer: us.tdk-lambda.com/lp/legal.htm
ZWS Series 2 Output Module Codes Model ZWS5-3 ZWS10-3 ZWS15-3 ZWS30-3 ZWS50-3 ZWS5-5 ZWS10-5 ZWS15-5 ZWS30-5 ZWS50-5 ZWS5-12 ZWS10-12 ZWS15-12 ZWS30-12 ZWS50-12 ZWS5-15 ZWS10-15 ZWS15-15 ZWS30-15 ZWS50-15 ZWS5-24 ZWS10-24 ZWS15-24 ZWS30-24 ZWS50-24 ZWS30-36 ZWS50-36 ZWS30-48 ZWS50-48
Adjust Voltage Range 3.3V 3.3V 3.3V 3.3V 3.3V 5V 5V 5V 5V 5V 12V 12V 12V 12V 12V 15V 15V 15V 15V 15V 24V 24V 24V 24V 24V 36V 36V 48V 48V
2.97-3.63 2.97-3.63 2.97-3.63 2.97-3.63 2.97-3.63 4.5-5.5 4.5-5.5 4.5-5.5 4.5-5.5 4.5-5.5 10.8-13.2 10.8-13.2 10.8-13.2 10.8-13.2 10.8-13.2 13.5-16.5 13.5-16.5 13.5-16.5 13.5-16.5 13.5-16.5 21.6-26.4 21.6-26.4 21.6-26.4 21.6-26.4 21.6-26.4 32.4-39.6 32.4-39.6 43.2-52.8 43.2-52.8
ZWS Outline Drawing
Max Peak Load Curr. Curr. Reg A A mV
Line Ripple Reg Noise Eff. mV mV %
1 2 3 6 10 1 2 3 6 10 0.42 0.85 1.25 2.5 4.3 0.34 0.7 1 2 3.5 0.22 0.45 0.65 1.3 2.1 0.9 1.4 0.7 1.1
20 20 20 20 20 20 20 20 20 20 48 48 48 48 48 60 60 60 60 60 96 96 96 96 96 144 144 192 192
1.2 2.4 3.6 7.2 12 1.2 2.4 3.6 7.2 12 0.51 1.02 1.5 3 5.16 0.41 0.84 1.2 2.4 4.2 0.27 0.54 0.78 1.56 2.52 1.08 1.68 0.84 1.32
40 40 40 40 40 40 40 40 40 40 96 96 96 96 96 120 120 120 120 120 150 150 150 150 150 240 240 300 300
120 120 120 120 120 120 120 120 120 120 150 150 150 150 150 150 150 150 150 150 200 200 200 200 200 300 300 400 400
Note for Peak Current: For 10s maximum, 35% duty cycle, average power not to exceed maximum ratings.
Options Suffix /A /J /JA Note:
Description Molex Terminals Cover option JST Connectors* JST Connectors & Cover * Recommended for new designs
1-800-526-2324 • www.us.tdk-lambda.com/lp/
62 62 63 70 73 67 70 71 75 77 68 70 71 77 80 68 71 71 77 81 70 71 71 78 82 78 82 78 82
A C
INPUT COMPONENT SIDE
D
B
CN1 J
OUTPUT K
F CN2
G E
G ZWS5-150 OUTLINE DRAWING
.118 MAX (3.0)
H
DIMENSIONS:
MODEL
ZWS5
ZWS10
A
B
C
D
3.86
1.77
3.580
1.500
(98.0)
(44.9)
(90.9)
(38.1)
4.14
1.97
3.860
1.690
(105.1)
(50.0)
(98.0)
(42.9)
4.93
1.97
4.650
1.690
(125.2)
(50.0)
(118.1)
(42.9)
5.24
2.17
4.850
1.770
ZWS15
ZWS30
ZWS50
(133.0)
(55.1)
(123.1)
(45.0)
7.68
2.17
7.290
1.770
(195.0)
(55.1)
(185.1)
(45.0)
E
F
-
-
-
-
-
-
-
-
-
-
G
H
J
K
.14
.83
1.05
.54
(3.5)
(21.0)
(26.6)
(13.7)
.14
.83
.99
.67
(3.5)
(21.0)
(25.1)
(18.4)
.14
.83
1.04
.57
(3.5)
(21.0)
(25.0)
(14.4)
.20
1.02
.20
1.16
(5.0)
(25.9)
(31.0)
(40.2)
.20
1.02
1.32
.72
(5.0)
(25.9)
(33.5)
(18.2)
L -
-
-
-
-
Other Industrial Products ZWS-AF ZWD/ZWQ SC HWS
50W to 150W Active PFC 100W to 440W Single & multiple output 30W to 120W Single, dual, & triple output 15W to 1800W Single output enclosed
For Additional Information, please visit us.tdk-lambda.com/lp/products/zws-series.htm
114
Revision A9: Dec 2011